Skip to main content
Top
Published in: Journal of Nuclear Cardiology 6/2017

01-12-2017 | Technologist Corner

Patient-specific activity or scan-time in SPECT myocardial perfusion imaging: A hands-on approach

Authors: J. D. van Dijk, MSc, PhD, P. L. Jager, PhD, MD, J. A. van Dalen, PhD

Published in: Journal of Nuclear Cardiology | Issue 6/2017

Login to get access

Excerpt

SPECT myocardial perfusion imaging (MPI) is the most validated non-invasive method to test for ischemia, and this procedure is performed over 15 to 20 million times annually.1,2 However, concerns have been raised as SPECT MPI is the single largest contributor to the radiation burden from medical imaging.3 Several approaches to reduce this burden have been studied: stress-only protocols, encouraging appropriate use of MPI, hardware advances, new reconstruction methods, and patient-specific protocols. In our previous studies, we showed that by implementing a patient-specific activity or scan-time protocol, one can drastically lower the tracer activity while image quality becomes less dependent of patients’ size.4 We also showed that such a protocol reduces the radiation dose, while the percentage of scans interpreted as normal and the prognostic value of these patients remains the same.5 However, multiple logistic adoptions are required in clinical practice to implement such a protocol. In this note, we explain how to derive a patient-specific activity or scan-time formula, discuss the pros and cons of several patient-specific protocols, and highlight the practical implications when implementing such a protocol in clinical practice. …
Appendix
Available only for authorised users
Literature
1.
go back to reference Underwood SR, Anagnostopoulos C, Cerqueira MD, Ell PJ, Flint EJ, Harbinson M, et al. Myocardial perfusion scintigraphy: the evidence. Eur J Nucl Med Mol Imaging. 2004;31:261–91.CrossRefPubMed Underwood SR, Anagnostopoulos C, Cerqueira MD, Ell PJ, Flint EJ, Harbinson M, et al. Myocardial perfusion scintigraphy: the evidence. Eur J Nucl Med Mol Imaging. 2004;31:261–91.CrossRefPubMed
3.
go back to reference Fazel R, Krumholz HM, Wang Y, Ross JS, Chen J, Ting HH, et al. Exposure to low-dose ionizing radiation from medical imaging procedures. N Engl J Med. 2009;361:849–57.CrossRefPubMedPubMedCentral Fazel R, Krumholz HM, Wang Y, Ross JS, Chen J, Ting HH, et al. Exposure to low-dose ionizing radiation from medical imaging procedures. N Engl J Med. 2009;361:849–57.CrossRefPubMedPubMedCentral
4.
go back to reference van Dijk JD, Jager PL, Mouden M, Slump CH, Ottervanger JP, de Boer J, et al. Development and validation of a patient-tailored dose regime in myocardial perfusion imaging using CZT-SPECT. J Nucl Cardiol. 2014;21:1158–67.CrossRefPubMed van Dijk JD, Jager PL, Mouden M, Slump CH, Ottervanger JP, de Boer J, et al. Development and validation of a patient-tailored dose regime in myocardial perfusion imaging using CZT-SPECT. J Nucl Cardiol. 2014;21:1158–67.CrossRefPubMed
5.
go back to reference van Dijk JD, Borren NM, Mouden M, van Dalen JA, Ottervanger JP, Jager PL. Effect of a patient-specific minimum activity in stress myocardial perfusion imaging using CZT-SPECT: prognostic value, radiation dose, and scan outcome. J Nucl Cardiol. 2017. doi:10.1007/s12350-017-1011-z. van Dijk JD, Borren NM, Mouden M, van Dalen JA, Ottervanger JP, Jager PL. Effect of a patient-specific minimum activity in stress myocardial perfusion imaging using CZT-SPECT: prognostic value, radiation dose, and scan outcome. J Nucl Cardiol. 2017. doi:10.​1007/​s12350-017-1011-z.
6.
go back to reference van Dijk JD, Jager PL, Ottervanger JP, de Boer J, Oostdijk AHJ, Engbers EM, et al. Development and validation of a patient-tailored dose regime in myocardial perfusion imaging using conventional SPECT. J Nucl Cardiol. 2016;23:134–42.CrossRefPubMed van Dijk JD, Jager PL, Ottervanger JP, de Boer J, Oostdijk AHJ, Engbers EM, et al. Development and validation of a patient-tailored dose regime in myocardial perfusion imaging using conventional SPECT. J Nucl Cardiol. 2016;23:134–42.CrossRefPubMed
7.
go back to reference van Dijk JD, Jager PL, Ottervanger JP, Slump CH, Knollema S, van Dalen JA. Patient-specific tracer activity in MPI SPECT: a hands-on approach. J Nucl Cardiol. 2016;23:145–8.CrossRefPubMed van Dijk JD, Jager PL, Ottervanger JP, Slump CH, Knollema S, van Dalen JA. Patient-specific tracer activity in MPI SPECT: a hands-on approach. J Nucl Cardiol. 2016;23:145–8.CrossRefPubMed
8.
go back to reference Henzlova MJ, Duvall WL, Einstein AJ, Travin MI, Verberne HJ. Erratum to: ASNC imaging guidelines for SPECT nuclear cardiology procedures: Stress, protocols, and tracers. J Nucl Cardiol. 2016;23:640–2.CrossRefPubMed Henzlova MJ, Duvall WL, Einstein AJ, Travin MI, Verberne HJ. Erratum to: ASNC imaging guidelines for SPECT nuclear cardiology procedures: Stress, protocols, and tracers. J Nucl Cardiol. 2016;23:640–2.CrossRefPubMed
9.
go back to reference Verberne HJ, Acampa W, Anagnostopoulos C, Ballinger J, Bengel F, De Bondt P, et al. EANM procedural guidelines for radionuclide myocardial perfusion imaging with SPECT and SPECT/CT: 2015 revision. Eur J Nucl Med Mol Imaging. 2015;42:1929–40.CrossRefPubMedPubMedCentral Verberne HJ, Acampa W, Anagnostopoulos C, Ballinger J, Bengel F, De Bondt P, et al. EANM procedural guidelines for radionuclide myocardial perfusion imaging with SPECT and SPECT/CT: 2015 revision. Eur J Nucl Med Mol Imaging. 2015;42:1929–40.CrossRefPubMedPubMedCentral
Metadata
Title
Patient-specific activity or scan-time in SPECT myocardial perfusion imaging: A hands-on approach
Authors
J. D. van Dijk, MSc, PhD
P. L. Jager, PhD, MD
J. A. van Dalen, PhD
Publication date
01-12-2017
Publisher
Springer US
Published in
Journal of Nuclear Cardiology / Issue 6/2017
Print ISSN: 1071-3581
Electronic ISSN: 1532-6551
DOI
https://doi.org/10.1007/s12350-017-1056-z

Other articles of this Issue 6/2017

Journal of Nuclear Cardiology 6/2017 Go to the issue

Images that Teach

Warm heart, cold liver