Skip to main content
Top
Published in: Journal of Nuclear Cardiology 1/2012

01-02-2012 | Review Article

Properties of an ideal PET perfusion tracer: New PET tracer cases and data

Author: Jamshid Maddahi, MD, FACC

Published in: Journal of Nuclear Cardiology | Special Issue 1/2012

Login to get access

Abstract

An ideal positron emission tomography (PET) tracer should be highly extractable by the myocardium and able to provide high-resolution images, should enable quantification of absolute myocardial blood flow (MBF), should be compatible with both pharmacologically induced and exercise-induced stress imaging, and should not require an on-site cyclotron. The PET radionuclides nitrogen-13 ammonia and oxygen-15 water require an on-site cyclotron. Rubidium-82 may be available locally due to the generator source, but greater utilization is limited because of its relatively low myocardial extraction fraction, long positron range, and generator cost. Flurpiridaz F 18, a novel PET tracer in development, has a high-extraction fraction, short positron range, and relatively long half-life (as compared to currently available tracers), and may be produced at regional cyclotrons. Results of early clinical trials suggest that both pharmacologically and exercise-induced stress PET imaging protocols can be completed more rapidly and with lower patient radiation exposure than with single-photon emission computerized tomography (SPECT) tracers. As compared to SPECT images in the same patients, flurpiridaz F 18 PET images showed better defect contrast. Flurpiridaz F 18 is a potentially promising tracer for assessment of myocardial perfusion, measurement of absolute MBF, calculation of coronary flow reserves, and assessment of cardiac function at the peak of the stress response.
Literature
1.
go back to reference Schelbert HR, Phelps ME, Huang SC, MacDonald NS, Hansen H, Selin C, et al. N-13 ammonia as an indicator of myocardial blood flow. Circulation 1981;63:1259-72.PubMedCrossRef Schelbert HR, Phelps ME, Huang SC, MacDonald NS, Hansen H, Selin C, et al. N-13 ammonia as an indicator of myocardial blood flow. Circulation 1981;63:1259-72.PubMedCrossRef
2.
go back to reference Bergman SR, Herrero P, Markham J, Weinheimer CJ, Walsh MN. Noninvasive quantitation of myocardial perfusion in human subjects with Oxygen-15 labeled water and positron emission tomography. J Am Coll Cardiol 1989;14:639-52.CrossRef Bergman SR, Herrero P, Markham J, Weinheimer CJ, Walsh MN. Noninvasive quantitation of myocardial perfusion in human subjects with Oxygen-15 labeled water and positron emission tomography. J Am Coll Cardiol 1989;14:639-52.CrossRef
3.
go back to reference Huang SC, Williams BA, Krivokapich J, Araujo L, Phelps ME, Schelbert HR. Rabbit myocardial 82Rb kinetics and a compartmental model for blood flow estimation. Am J Physiol 1989;256:H1156-64.PubMed Huang SC, Williams BA, Krivokapich J, Araujo L, Phelps ME, Schelbert HR. Rabbit myocardial 82Rb kinetics and a compartmental model for blood flow estimation. Am J Physiol 1989;256:H1156-64.PubMed
4.
go back to reference Glover DK, Gropler RJ. Journey to find the ideal PET flow tracer for clinical use: Are we there yet? J Nucl Cardiol 2007;14:765-8.PubMedCrossRef Glover DK, Gropler RJ. Journey to find the ideal PET flow tracer for clinical use: Are we there yet? J Nucl Cardiol 2007;14:765-8.PubMedCrossRef
5.
go back to reference Garcia EV, Galt R, Faber TL, Chen J. Principles of nuclear cardiology. In: Dilsizian V, Narula J, editors. Atlas of nuclear cardiology, Chapter 1. 3rd ed. Philadelphia: Current Medicine LLC; 2009. p. 1-34. Garcia EV, Galt R, Faber TL, Chen J. Principles of nuclear cardiology. In: Dilsizian V, Narula J, editors. Atlas of nuclear cardiology, Chapter 1. 3rd ed. Philadelphia: Current Medicine LLC; 2009. p. 1-34.
6.
go back to reference Yalamanchili P, Wexler E, Hayes M, Yu M, Bozek J, Kagan M, et al. Mechanism of uptake and retention of F-18 BMS-747 158-02 in cardiomyocytes: A novel PET myocardial imaging agent. J Nucl Cardiol 2007;14:782-8.PubMedCrossRef Yalamanchili P, Wexler E, Hayes M, Yu M, Bozek J, Kagan M, et al. Mechanism of uptake and retention of F-18 BMS-747 158-02 in cardiomyocytes: A novel PET myocardial imaging agent. J Nucl Cardiol 2007;14:782-8.PubMedCrossRef
7.
go back to reference Yu M, Guaraldi MT, Mistry M, Kagan M, McDonald JL, Drew K, et al. BMS-747158-02: A novel PET myocardial perfusion imaging agent. J Nucl Cardiol 2007;14:789-98.PubMedCrossRef Yu M, Guaraldi MT, Mistry M, Kagan M, McDonald JL, Drew K, et al. BMS-747158-02: A novel PET myocardial perfusion imaging agent. J Nucl Cardiol 2007;14:789-98.PubMedCrossRef
8.
go back to reference Huisman MC, Higuchi T, Reder S, Nekolla SG, Poethko T, Wester H-J, et al. Initial characterization of an 18F-labeled myocardial perfusion tracer. J Nucl Med 2008;49:630-6.PubMedCrossRef Huisman MC, Higuchi T, Reder S, Nekolla SG, Poethko T, Wester H-J, et al. Initial characterization of an 18F-labeled myocardial perfusion tracer. J Nucl Med 2008;49:630-6.PubMedCrossRef
9.
go back to reference Nekolla SG, Reder S, Saraste A, Higuchi T, Dzewas G, Preissel A, et al. Evaluation of the novel myocardial perfusion PET tracer 18F-BMS747158-02: Comparison to 13 N-ammonia and validation with microspheres in a pig model. Circulation 2009;119:2333-42.PubMedCrossRef Nekolla SG, Reder S, Saraste A, Higuchi T, Dzewas G, Preissel A, et al. Evaluation of the novel myocardial perfusion PET tracer 18F-BMS747158-02: Comparison to 13 N-ammonia and validation with microspheres in a pig model. Circulation 2009;119:2333-42.PubMedCrossRef
10.
go back to reference Maddahi J, Czernin J, Lazewatsky J, Huang S-C, Dahlbom M, Schelbert H, et al. Phase I, first-in-human study of BMS747158, a novel 18F-labeled tracer for myocardial perfusion PET: Dosimetry, biodistribution, safety, and imaging characteristics after a single injection at rest. J Nucl Med 2011;52:1490-8.PubMedCrossRef Maddahi J, Czernin J, Lazewatsky J, Huang S-C, Dahlbom M, Schelbert H, et al. Phase I, first-in-human study of BMS747158, a novel 18F-labeled tracer for myocardial perfusion PET: Dosimetry, biodistribution, safety, and imaging characteristics after a single injection at rest. J Nucl Med 2011;52:1490-8.PubMedCrossRef
11.
go back to reference Maddahi J, Bengel F, Huang S-C, Czernin J, Schelbert H, Zhu Q, et al. Phase 1 rest-stress study of F-18 labeled BMS747158 myocardial perfusion PET tracer: Human safety, dosimetry, biodistribution, and myocardial imaging characteristics. J Nucl Med 2009;50:184 (abstract).CrossRef Maddahi J, Bengel F, Huang S-C, Czernin J, Schelbert H, Zhu Q, et al. Phase 1 rest-stress study of F-18 labeled BMS747158 myocardial perfusion PET tracer: Human safety, dosimetry, biodistribution, and myocardial imaging characteristics. J Nucl Med 2009;50:184 (abstract).CrossRef
12.
go back to reference Case J, Maddahi J, Bengel F, Bateman T, Dahlbom M, Lazewatsky J. Imaging properties of F-18 labeled myocardial perfusion PET agent, BMS747158: Dosage, acquisition time and scanner type. J Nucl Med 2009;50:418 (abstract). Case J, Maddahi J, Bengel F, Bateman T, Dahlbom M, Lazewatsky J. Imaging properties of F-18 labeled myocardial perfusion PET agent, BMS747158: Dosage, acquisition time and scanner type. J Nucl Med 2009;50:418 (abstract).
13.
go back to reference Maddahi J, Huang S-C, Schiepers C, Bengel F, Czernin J, Schelbert H, et al. Same-day rest-stress protocols for PET imaging with the new F-18 labeled BMS747158 myocardial perfusion tracer. J Nucl Med 2009;50:1173 (abstract). Maddahi J, Huang S-C, Schiepers C, Bengel F, Czernin J, Schelbert H, et al. Same-day rest-stress protocols for PET imaging with the new F-18 labeled BMS747158 myocardial perfusion tracer. J Nucl Med 2009;50:1173 (abstract).
14.
go back to reference Case J, Lazewatsky J, Hsu B-L, Maddahi J, Berman D, Bateman T. Automatic registration of F-18 labeled BMS-747158 stress and rest myocardial perfusion images using 6D cross-correlation optimization. J Nucl Med 2010;51:1687 (abstract). Case J, Lazewatsky J, Hsu B-L, Maddahi J, Berman D, Bateman T. Automatic registration of F-18 labeled BMS-747158 stress and rest myocardial perfusion images using 6D cross-correlation optimization. J Nucl Med 2010;51:1687 (abstract).
15.
go back to reference Hsu B, Lazewatsky J, Bateman T, Devine M, Maddahi J, Berman D, et al. Cardiac phantom simulation of dose injection parameters for one-day rest/stress myocardial perfusion (MPI) PET imaging with BMS747158 tracer. J Nucl Med 2010;51:320 (abstract). Hsu B, Lazewatsky J, Bateman T, Devine M, Maddahi J, Berman D, et al. Cardiac phantom simulation of dose injection parameters for one-day rest/stress myocardial perfusion (MPI) PET imaging with BMS747158 tracer. J Nucl Med 2010;51:320 (abstract).
16.
go back to reference Lazewatsky J, Maddahi J, Berman D, Bhat G, Sinha S, Devine M, et al. Development of a method for the determination of dose ratio and minimum inter-injection interval for a one-day rest-stress protocol with BMS747158 PET myocardial perfusion agent. J Nucl Med 2010;51:600 (abstract). Lazewatsky J, Maddahi J, Berman D, Bhat G, Sinha S, Devine M, et al. Development of a method for the determination of dose ratio and minimum inter-injection interval for a one-day rest-stress protocol with BMS747158 PET myocardial perfusion agent. J Nucl Med 2010;51:600 (abstract).
17.
go back to reference Maddahi J, Czernin J, Ehlgen A, Lazewatsky J, Zhu Q, Phelps M. Comparison of F-18 labeled BMS747158 PET and Tc-99m labeled SPECT myocardial perfusion imaging for detection and evaluation of coronary artery disease. J Am Coll Cardiol 2010;55:A65.E616.CrossRef Maddahi J, Czernin J, Ehlgen A, Lazewatsky J, Zhu Q, Phelps M. Comparison of F-18 labeled BMS747158 PET and Tc-99m labeled SPECT myocardial perfusion imaging for detection and evaluation of coronary artery disease. J Am Coll Cardiol 2010;55:A65.E616.CrossRef
18.
go back to reference Schelbert HR. Quantification of myocardial blood flow: What is the clinical role? Cardiol Clin 2009;27:277-89.PubMedCrossRef Schelbert HR. Quantification of myocardial blood flow: What is the clinical role? Cardiol Clin 2009;27:277-89.PubMedCrossRef
19.
go back to reference Maddahi J, Huang S, Truong D, Lazewatsky JL, Ehlgen A, Schelbert H, et al. Preliminary results of absolute quantification of rest and stress myocardial blood flow with flurpiridaz F-18 PET in normal and coronary artery disease patients in a single-center study. J Nucl Cardiol 2010;17:743 (abstract).CrossRef Maddahi J, Huang S, Truong D, Lazewatsky JL, Ehlgen A, Schelbert H, et al. Preliminary results of absolute quantification of rest and stress myocardial blood flow with flurpiridaz F-18 PET in normal and coronary artery disease patients in a single-center study. J Nucl Cardiol 2010;17:743 (abstract).CrossRef
Metadata
Title
Properties of an ideal PET perfusion tracer: New PET tracer cases and data
Author
Jamshid Maddahi, MD, FACC
Publication date
01-02-2012
Publisher
Springer-Verlag
Published in
Journal of Nuclear Cardiology / Issue Special Issue 1/2012
Print ISSN: 1071-3581
Electronic ISSN: 1532-6551
DOI
https://doi.org/10.1007/s12350-011-9491-8

Other articles of this Special Issue 1/2012

Journal of Nuclear Cardiology 1/2012 Go to the issue