Skip to main content
Top
Published in: Journal of Nuclear Cardiology 2/2011

01-04-2011 | Original Article

Soft tissue attenuation patterns in stress myocardial perfusion SPECT images: A comparison between supine and upright acquisition systems

Authors: David Chawla, MD, Mouyyad Rahaby, MD, Amit P. Amin, MD, Raj Vashistha, MD, Tareq Alyousef, MD, Hector X. Martinez, BS, CNMT, RT(N), Rami Doukky, MD, FACC, FASNC

Published in: Journal of Nuclear Cardiology | Issue 2/2011

Login to get access

Abstract

Background

Soft tissue attenuation patterns and their interaction with body habitus and gender in Single Photon Emission Computed Tomography (SPECT)-myocardial perfusion imaging (MPI) of upright patient-position acquisition systems are not well described.

Methods

In a retrospective cross-sectional study, we compared the prevalence and patterns of soft tissue attenuation in two groups of normal SPECT-MPI studies acquired by supine (n = 263) vs upright (n = 212) acquisition systems.

Results

Attenuation patterns observed in the study population were: anterior (22.3%), inferior (51.6%) and lateral (18.1%). Anterior attenuation was significantly less in those imaged upright (6.1% vs 35.4%), P < .001; particularly among women (9.5% vs 50.7%), P < .001. Inferior attenuation was more common among women imaged upright (49.5% vs 13.5%), P < .001; but was not affected by imaging position among men. Lateral attenuation was more prevalent in the upright group (24.1% vs 13.3%), P = .002; and had a strong association with female gender (P < .001) and BMI ≥ 30 (P < .001).

Conclusions

Upright SPECT-MPI acquisition is associated with a unique attenuation pattern which is vastly different than the supine position. Female gender strongly impacted this attenuation pattern, particularly obese women. Our study is the first to describe, in details, the attenuation patterns with upright imaging and is critical for the accurate interpretation of SPECT-MPI acquired with upright systems.
Literature
1.
go back to reference Hendel RC. Attenuation correction: Eternal dilemma or real improvement? Q J Nucl Med Mol Imaging 2005;49:30-42.PubMed Hendel RC. Attenuation correction: Eternal dilemma or real improvement? Q J Nucl Med Mol Imaging 2005;49:30-42.PubMed
2.
go back to reference Heller GV, Links J, Bateman TM, Ziffer JA, Ficaro E, Cohen MC, et al. American Society of Nuclear Cardiology and Society of Nuclear Medicine joint position statement: Attenuation correction of myocardial perfusion SPECT scintigraphy. J Nucl Cardiol 2004;11:229-30.PubMedCrossRef Heller GV, Links J, Bateman TM, Ziffer JA, Ficaro E, Cohen MC, et al. American Society of Nuclear Cardiology and Society of Nuclear Medicine joint position statement: Attenuation correction of myocardial perfusion SPECT scintigraphy. J Nucl Cardiol 2004;11:229-30.PubMedCrossRef
3.
go back to reference Bybel B, Brunken RC, DiFilippo FP, Neumann DR, Wu G, Cerqueira MD. SPECT/CT imaging: Clinical utility of an emerging technology. Radiographics 2008;28:1097-113.PubMedCrossRef Bybel B, Brunken RC, DiFilippo FP, Neumann DR, Wu G, Cerqueira MD. SPECT/CT imaging: Clinical utility of an emerging technology. Radiographics 2008;28:1097-113.PubMedCrossRef
4.
go back to reference Garcia EV. SPECT attenuation correction: An essential tool to realize nuclear cardiology’s manifest destiny. J Nucl Cardiol 2007;14:16-24.PubMedCrossRef Garcia EV. SPECT attenuation correction: An essential tool to realize nuclear cardiology’s manifest destiny. J Nucl Cardiol 2007;14:16-24.PubMedCrossRef
5.
go back to reference Singh B, Bateman TM, Case JA, Heller G. Attenuation artifact, attenuation correction, and the future of myocardial perfusion SPECT. J Nucl Cardiol 2007;14:153-64.PubMedCrossRef Singh B, Bateman TM, Case JA, Heller G. Attenuation artifact, attenuation correction, and the future of myocardial perfusion SPECT. J Nucl Cardiol 2007;14:153-64.PubMedCrossRef
6.
go back to reference IMV Medicine Market Summary Report, Des Plaines IL: IMV Medical Information Division. 2008. IMV Medicine Market Summary Report, Des Plaines IL: IMV Medical Information Division. 2008.
7.
go back to reference Hendel RC. Interpretation of myocardial perfusion imaging. In: Heller GV, Hendel RC, editors. Nuclear cardiology: Practical applications. New York: McGraw-Hill; 2004. p. 157-74. Hendel RC. Interpretation of myocardial perfusion imaging. In: Heller GV, Hendel RC, editors. Nuclear cardiology: Practical applications. New York: McGraw-Hill; 2004. p. 157-74.
8.
go back to reference Chaptini N, Dontaraju VS, Concepcion F, Muradi HA, Alyousef T, Del Pilar Aristizabal Canaval M, et al. Ambulatory cardiac single-photon emission computed tomography at the primary care physician’s office: A descriptive study. J Ambul Care Manage 2010;33:328-35.PubMed Chaptini N, Dontaraju VS, Concepcion F, Muradi HA, Alyousef T, Del Pilar Aristizabal Canaval M, et al. Ambulatory cardiac single-photon emission computed tomography at the primary care physician’s office: A descriptive study. J Ambul Care Manage 2010;33:328-35.PubMed
9.
go back to reference Tonge CM, Armstrong IS, Arumugam P, James JM, Al-Bahrani GI, Lawson RS, et al. Changes in the appearance of attenuation artefacts due to change in posture in myocardial perfusion imaging. Nucl Med Commun 2008;29:441-7.PubMedCrossRef Tonge CM, Armstrong IS, Arumugam P, James JM, Al-Bahrani GI, Lawson RS, et al. Changes in the appearance of attenuation artefacts due to change in posture in myocardial perfusion imaging. Nucl Med Commun 2008;29:441-7.PubMedCrossRef
10.
go back to reference Conwell R, Kindem J, Bai C, Maddahi J. A novel cardiac SPECT system with X-ray-based attenuation correction using the same solid state detectors for both emission and transmission scans. J Nucl Med 2008;49:64.CrossRef Conwell R, Kindem J, Bai C, Maddahi J. A novel cardiac SPECT system with X-ray-based attenuation correction using the same solid state detectors for both emission and transmission scans. J Nucl Med 2008;49:64.CrossRef
11.
go back to reference Maddahi J, Conwell R, Mendez R, Babla H, Bai C, Kindem J, et al. Clinical evaluation of a low-dose, X-ray-based transmission imaging technique for attenuation correction of SPECT myocardial perfusion images. Eur Heart J 2009;11:S46-8.CrossRef Maddahi J, Conwell R, Mendez R, Babla H, Bai C, Kindem J, et al. Clinical evaluation of a low-dose, X-ray-based transmission imaging technique for attenuation correction of SPECT myocardial perfusion images. Eur Heart J 2009;11:S46-8.CrossRef
12.
go back to reference Abbott BG. Stress testing. In: Mann A, Heller GV, Hendel RC, editors. Nuclear cardiology: Technical applications. New York: McGraw-Hill; 2007. p. 97-106. Abbott BG. Stress testing. In: Mann A, Heller GV, Hendel RC, editors. Nuclear cardiology: Technical applications. New York: McGraw-Hill; 2007. p. 97-106.
13.
go back to reference Doukky R. Pharmacologic Stress testing in myocardial perfusion imaging: Technical applications. In: Mann A, Heller GV, Hendel RC, editors. Nuclear Cardiology: Technical Applications. New York: McGraw-Hill; 2007. p. 107-24. Doukky R. Pharmacologic Stress testing in myocardial perfusion imaging: Technical applications. In: Mann A, Heller GV, Hendel RC, editors. Nuclear Cardiology: Technical Applications. New York: McGraw-Hill; 2007. p. 107-24.
14.
go back to reference Henzlova MJ, Cerqueira MD, Mahmarian JJ, Yao SS. Stress protocols and tracers. J Nucl Cardiol 2006;13:e80-90.PubMedCrossRef Henzlova MJ, Cerqueira MD, Mahmarian JJ, Yao SS. Stress protocols and tracers. J Nucl Cardiol 2006;13:e80-90.PubMedCrossRef
15.
go back to reference Hansen CL, Goldstein RA, Berman DS, Churchwell KB, Cooke CD, Corbett JR, et al. Myocardial perfusion and function single photon emission computed tomography. J Nucl Cardiol 2006;13:e97-120.PubMedCrossRef Hansen CL, Goldstein RA, Berman DS, Churchwell KB, Cooke CD, Corbett JR, et al. Myocardial perfusion and function single photon emission computed tomography. J Nucl Cardiol 2006;13:e97-120.PubMedCrossRef
17.
go back to reference Diamond GA, Forrester JS. Analysis of probability as an aid in the clinical diagnosis of coronary-artery disease. N Engl J Med 1979;300:1350-8.PubMedCrossRef Diamond GA, Forrester JS. Analysis of probability as an aid in the clinical diagnosis of coronary-artery disease. N Engl J Med 1979;300:1350-8.PubMedCrossRef
18.
go back to reference Wilson PW, D’Agostino RB, Levy D, Belanger AM, Silbershatz H, Kannel WB. Prediction of coronary heart disease using risk factor categories. Circulation 1998;97:1837-47.PubMed Wilson PW, D’Agostino RB, Levy D, Belanger AM, Silbershatz H, Kannel WB. Prediction of coronary heart disease using risk factor categories. Circulation 1998;97:1837-47.PubMed
19.
go back to reference Gibbons RJ, Miller TD, Hodge D, Urban L, Araoz PA, Pellikka P, et al. Application of appropriateness criteria to stress single-photon emission computed tomography sestamibi studies and stress echocardiograms in an academic medical center. J Am Coll Cardiol 2008;51:1283-9.PubMedCrossRef Gibbons RJ, Miller TD, Hodge D, Urban L, Araoz PA, Pellikka P, et al. Application of appropriateness criteria to stress single-photon emission computed tomography sestamibi studies and stress echocardiograms in an academic medical center. J Am Coll Cardiol 2008;51:1283-9.PubMedCrossRef
20.
go back to reference Hendel RC, Cerqueira M, Douglas PS, Caruth KC, Allen JM, Jensen NC, et al. A multicenter assessment of the use of single-photon emission computed tomography myocardial perfusion imaging with appropriateness criteria. J Am Coll Cardiol 2010;55:156-62.PubMedCrossRef Hendel RC, Cerqueira M, Douglas PS, Caruth KC, Allen JM, Jensen NC, et al. A multicenter assessment of the use of single-photon emission computed tomography myocardial perfusion imaging with appropriateness criteria. J Am Coll Cardiol 2010;55:156-62.PubMedCrossRef
21.
go back to reference Katayama T, Ogata N, Tsuruya Y. Diagnostic accuracy of supine and prone thallium-201 stress myocardial perfusion single-photon emission computed tomography to detect coronary artery disease in inferior wall of left ventricle. Ann Nucl Med 2008;22:317-21.PubMedCrossRef Katayama T, Ogata N, Tsuruya Y. Diagnostic accuracy of supine and prone thallium-201 stress myocardial perfusion single-photon emission computed tomography to detect coronary artery disease in inferior wall of left ventricle. Ann Nucl Med 2008;22:317-21.PubMedCrossRef
22.
go back to reference Nishina H, Slomka PJ, Abidov A, Yoda S, Akincioglu C, Kang X, et al. Combined supine and prone quantitative myocardial perfusion SPECT: Method development and clinical validation in patients with no known coronary artery disease. J Nucl Med 2006;47:51-8.PubMed Nishina H, Slomka PJ, Abidov A, Yoda S, Akincioglu C, Kang X, et al. Combined supine and prone quantitative myocardial perfusion SPECT: Method development and clinical validation in patients with no known coronary artery disease. J Nucl Med 2006;47:51-8.PubMed
Metadata
Title
Soft tissue attenuation patterns in stress myocardial perfusion SPECT images: A comparison between supine and upright acquisition systems
Authors
David Chawla, MD
Mouyyad Rahaby, MD
Amit P. Amin, MD
Raj Vashistha, MD
Tareq Alyousef, MD
Hector X. Martinez, BS, CNMT, RT(N)
Rami Doukky, MD, FACC, FASNC
Publication date
01-04-2011
Publisher
Springer-Verlag
Published in
Journal of Nuclear Cardiology / Issue 2/2011
Print ISSN: 1071-3581
Electronic ISSN: 1532-6551
DOI
https://doi.org/10.1007/s12350-010-9336-x

Other articles of this Issue 2/2011

Journal of Nuclear Cardiology 2/2011 Go to the issue

Journal of Nuclear Cardiology News Update

Perspectives on Radiation Exposure

Nuclear Cardiology in the Literature

Nuclear cardiology in the literature