Skip to main content
Top
Published in: Journal of Nuclear Cardiology 1/2009

01-02-2009 | Original Article

Intra-patient reproducibility of myocardial SPECT imaging with 201Tl

Authors: Barbra E. Backus, MD, Frederik A. Verburg, MD, R. Leo Romijn, PhD, Mark W. Konijnenberg, PhD, Freek J. Beekman, MD, PhD, J. Fred Verzijlbergen, MD, PhD

Published in: Journal of Nuclear Cardiology | Issue 1/2009

Login to get access

Abstract

Background

To define the physical and clinical reproducibility of 201Tl myocardial perfusion SPECT (MPS), this study assesses the variation between two repeated rest 201Tl MPS with repositioning only, with a two-hour time interval and with phantom measurements as a reference.

Methods

Three anthropomorphic thorax phantoms were filled with 201Tl. For each phantom five repeated 201Tl MPS were obtained. In addition, in 20 patients repeated 201Tl rest-MPS and in 26 patients early and delayed 201Tl rest-MPS were performed. Quantitative analysis was done using MunichHeart. Statistical methods were used to calculate variability. Visual analysis was performed by 2 independent observers.

Results

The average variation between repeated phantom MPS was 0.5% (95% confidence interval (CI): −0.4% to 1.4%). For patient scans this was −5.0% (95% CI: −2.5% to −7.5%) and between early and delayed 201Tl MPS −15.5% (95% CI: −11.7% to −19.3%). Visual assessment revealed no clinical significant differences between rest 201Tl and repeated or delayed 201Tl MPS.

Conclusions

Repositioning in phantom 201Tl MPS does not cause significant variation. Repeated 201Tl MPS in patients shows 5.0% decrease of 201Tl in 30 minutes, which increases to 15% during a two-hour time interval without quantitative or visual regional differences. This decrease indicates a time-related washout of 201Tl, but does not change clinical diagnosis.
Literature
1.
go back to reference de Jong HW, Beekman FJ, Viergever MA, van Rijk PP. Simultaneous (99m)Tc/(201)Tl dual-isotope SPET with Monte Carlo-based down-scatter correction. Eur J Nucl Med Mol Imaging 2002;29(8):1063-71.PubMedCrossRef de Jong HW, Beekman FJ, Viergever MA, van Rijk PP. Simultaneous (99m)Tc/(201)Tl dual-isotope SPET with Monte Carlo-based down-scatter correction. Eur J Nucl Med Mol Imaging 2002;29(8):1063-71.PubMedCrossRef
2.
go back to reference Weinmann P, Faraggi M, Moretti JL, Hannequin P. Clinical validation of simultaneous dual-isotope myocardial scintigraphy. Eur J Nucl Med Mol Imaging 2003;30(1):25-31.PubMedCrossRef Weinmann P, Faraggi M, Moretti JL, Hannequin P. Clinical validation of simultaneous dual-isotope myocardial scintigraphy. Eur J Nucl Med Mol Imaging 2003;30(1):25-31.PubMedCrossRef
3.
go back to reference Nakamura M, Takeda K, Ichihara T, et al. Feasibility of simultaneous stress 99mTc-sestamibi/rest 201Tl dual-isotope myocardial perfusion SPECT in the detection of coronary artery disease. J Nucl Med 1999;40(6):895-903.PubMed Nakamura M, Takeda K, Ichihara T, et al. Feasibility of simultaneous stress 99mTc-sestamibi/rest 201Tl dual-isotope myocardial perfusion SPECT in the detection of coronary artery disease. J Nucl Med 1999;40(6):895-903.PubMed
4.
go back to reference Nekolla SG, Miethaner C, Nguyen N, Ziegler SI, Schwaiger M. Reproducibility of polar map generation and assessment of defect severity and extent assessment in myocardial perfusion imaging using positron emission tomography. Eur J Nucl Med 1998;25(9):1313-21.PubMedCrossRef Nekolla SG, Miethaner C, Nguyen N, Ziegler SI, Schwaiger M. Reproducibility of polar map generation and assessment of defect severity and extent assessment in myocardial perfusion imaging using positron emission tomography. Eur J Nucl Med 1998;25(9):1313-21.PubMedCrossRef
5.
go back to reference LaCroix KJ, Tsui BM, Hasegawa BH. A comparison of 180 degrees and 360 degrees acquisition for attenuation-compensated thallium-201 SPECT images. J Nucl Med 1998;39(3):562-74.PubMed LaCroix KJ, Tsui BM, Hasegawa BH. A comparison of 180 degrees and 360 degrees acquisition for attenuation-compensated thallium-201 SPECT images. J Nucl Med 1998;39(3):562-74.PubMed
6.
go back to reference Grunwald AM, Watson DD, Holzgrefe HH Jr, Irving JF, Beller GA. Myocardial thallium-201 kinetics in normal and ischemic myocardium. Circulation 1981;64(3):610-8.PubMed Grunwald AM, Watson DD, Holzgrefe HH Jr, Irving JF, Beller GA. Myocardial thallium-201 kinetics in normal and ischemic myocardium. Circulation 1981;64(3):610-8.PubMed
7.
go back to reference L’Abbate A, Biagini A, Michelassi C, Maseri A. Myocardial kinetics of thallium and potassium in man. Circulation 1979;60(4):776-85.PubMed L’Abbate A, Biagini A, Michelassi C, Maseri A. Myocardial kinetics of thallium and potassium in man. Circulation 1979;60(4):776-85.PubMed
8.
go back to reference Pitman AG, Kalff V, Van Every B, Risa B, Barnden LR, Kelly MJ. Contributions of subdiaphragmatic activity, attenuation, and diaphragmatic motion to inferior wall artifact in attenuation-corrected Tc-99m myocardial perfusion SPECT. J Nucl Cardiol 2005;12(4):401-9.PubMedCrossRef Pitman AG, Kalff V, Van Every B, Risa B, Barnden LR, Kelly MJ. Contributions of subdiaphragmatic activity, attenuation, and diaphragmatic motion to inferior wall artifact in attenuation-corrected Tc-99m myocardial perfusion SPECT. J Nucl Cardiol 2005;12(4):401-9.PubMedCrossRef
9.
go back to reference Pitman AG, Kalff V, Van Every B, Risa B, Barnden LR, Kelly MJ. Effect of mechanically simulated diaphragmatic respiratory motion on myocardial SPECT processed with and without attenuation correction. J Nucl Med 2002;43(9):1259-67.PubMed Pitman AG, Kalff V, Van Every B, Risa B, Barnden LR, Kelly MJ. Effect of mechanically simulated diaphragmatic respiratory motion on myocardial SPECT processed with and without attenuation correction. J Nucl Med 2002;43(9):1259-67.PubMed
Metadata
Title
Intra-patient reproducibility of myocardial SPECT imaging with 201Tl
Authors
Barbra E. Backus, MD
Frederik A. Verburg, MD
R. Leo Romijn, PhD
Mark W. Konijnenberg, PhD
Freek J. Beekman, MD, PhD
J. Fred Verzijlbergen, MD, PhD
Publication date
01-02-2009
Publisher
Springer-Verlag
Published in
Journal of Nuclear Cardiology / Issue 1/2009
Print ISSN: 1071-3581
Electronic ISSN: 1532-6551
DOI
https://doi.org/10.1007/s12350-008-9011-7

Other articles of this Issue 1/2009

Journal of Nuclear Cardiology 1/2009 Go to the issue

ASNC Announcement

ASNC Announcement