Physiologic and Pathologic Changes in Patients with Continuous-Flow Ventricular Assist Devices

Authors: Ranjit John, Andrew Boyle, Frank Pagani, Leslie Miller

Published in: Journal of Cardiovascular Translational Research | Issue 2/2009

Login to get access

Abstract

The clinical use of the newer continuous-flow pumps for mechanical circulatory support have resulted in superior outcomes including significantly reduced complication rates with improved durability over first generation pulsatile design pumps. However, as with all new technology, the newer LVADs have introduced a different set of management issues, as well as a unique risk profile into the mechanical circulatory support arena that were previously absent or unimportant with pulsatile LVADs. These include the effects of continuous flow on the systemic circulation and end-organ function, risk of thromboembolism, and pump thrombosis related to contact bearings in the blood path, the possible increased incidence of gastrointestinal bleeding, and ventricular arrhythmias, as well as alterations in the unloading characteristics of continuous-flow devices. This manuscript overviews the physiologic and pathologic effects that are associated with continuous-flow pumps and their unique management issues and complications.
Literature
1.
go back to reference Frazier, O. H., Rose, E. A., Oz, M. C., et al. (2001). Multicenter clinical evaluation of the HeartMate vented electric left ventricular assist system in patients awaiting heart transplantation. Journal of thoracic and cardiovascular surgery, 122, 1186–1195.PubMedCrossRef Frazier, O. H., Rose, E. A., Oz, M. C., et al. (2001). Multicenter clinical evaluation of the HeartMate vented electric left ventricular assist system in patients awaiting heart transplantation. Journal of thoracic and cardiovascular surgery, 122, 1186–1195.PubMedCrossRef
2.
go back to reference Frazier, O. H., Rose, E. A., McCarthy, P., et al. (1995). Improved mortality and rehabilitation of transplant candidates treated with a long-term implantable left ventricular assist system. Annals of Surgery, 222, 327–336.PubMedCrossRef Frazier, O. H., Rose, E. A., McCarthy, P., et al. (1995). Improved mortality and rehabilitation of transplant candidates treated with a long-term implantable left ventricular assist system. Annals of Surgery, 222, 327–336.PubMedCrossRef
3.
go back to reference Morgan, J. A., John, R., Rao, V., et al. (2004). Bridging to transplant with the HeartMate left ventricular assist device: The Columbia Presbyterian 12-year experience. Journal of thoracic and cardiovascular surgery, 127, 1309–1316.PubMedCrossRef Morgan, J. A., John, R., Rao, V., et al. (2004). Bridging to transplant with the HeartMate left ventricular assist device: The Columbia Presbyterian 12-year experience. Journal of thoracic and cardiovascular surgery, 127, 1309–1316.PubMedCrossRef
4.
go back to reference Rose, E. A., Gelijns, A. C., Moskowitz, A. J., et al. (2001). Long-term mechanical left ventricular assistance for end-stage heart failure. New England Journal of Medicine, 345, 1435–1443.PubMedCrossRef Rose, E. A., Gelijns, A. C., Moskowitz, A. J., et al. (2001). Long-term mechanical left ventricular assistance for end-stage heart failure. New England Journal of Medicine, 345, 1435–1443.PubMedCrossRef
5.
go back to reference Pagani, F. D., Long, J. W., Dembitsky, W. P., et al. (2006). Improved mechanical reliability of the HeartMate XVE left ventricular assist system. Annals of Thoracic Surgery, 82, 1413–1419.PubMedCrossRef Pagani, F. D., Long, J. W., Dembitsky, W. P., et al. (2006). Improved mechanical reliability of the HeartMate XVE left ventricular assist system. Annals of Thoracic Surgery, 82, 1413–1419.PubMedCrossRef
6.
go back to reference Feller, E. D., Sorensen, E. N., Haddad, M., et al. (2007). Clinical outcomes are similar in pulsatile and nonpulsatile left ventricular assist device recipients. Annals of Thoracic Surgery, 83, 1082–1088.PubMedCrossRef Feller, E. D., Sorensen, E. N., Haddad, M., et al. (2007). Clinical outcomes are similar in pulsatile and nonpulsatile left ventricular assist device recipients. Annals of Thoracic Surgery, 83, 1082–1088.PubMedCrossRef
7.
go back to reference Frazier, O. H., Gemmato, C., Myers, T. J., et al. (2007). Initial clinical experience with the HeartMate II axial-flow left ventricular assist device. Texas Heart Institute Journal, 34, 275–281.PubMed Frazier, O. H., Gemmato, C., Myers, T. J., et al. (2007). Initial clinical experience with the HeartMate II axial-flow left ventricular assist device. Texas Heart Institute Journal, 34, 275–281.PubMed
8.
go back to reference Miller, L. W., Pagani, F. D., Russell, S. D., et al. (2007). Use of a continuous-flow device in patients awaiting heart transplantation. New England Journal of Medicine, 357, 885–896.PubMedCrossRef Miller, L. W., Pagani, F. D., Russell, S. D., et al. (2007). Use of a continuous-flow device in patients awaiting heart transplantation. New England Journal of Medicine, 357, 885–896.PubMedCrossRef
9.
go back to reference John, R., Kamdar, F., Liao, K., et al. (2008). Improved survival and decreasing incidence of adverse events using the HeartMate II left ventricular assist device as a bridge-to-transplant. Annals of Thoracic Surgery, 86, 1227–1235.PubMedCrossRef John, R., Kamdar, F., Liao, K., et al. (2008). Improved survival and decreasing incidence of adverse events using the HeartMate II left ventricular assist device as a bridge-to-transplant. Annals of Thoracic Surgery, 86, 1227–1235.PubMedCrossRef
10.
go back to reference John, R. (2008). Current axial flow pumps—HeartMate II and Jarvik LVADs. Seminars in Thoracic and Cardiovascular Surgery, 20, 264–272.PubMedCrossRef John, R. (2008). Current axial flow pumps—HeartMate II and Jarvik LVADs. Seminars in Thoracic and Cardiovascular Surgery, 20, 264–272.PubMedCrossRef
11.
go back to reference Rose, E. A., Levin, H. R., Oz, M. C., et al. (1994). Artificial circulatory support with textured interior surfaces: a counterintuitive approach to minimize thromboembolism. Circulation, 90(5 pt 2), II87–91.PubMed Rose, E. A., Levin, H. R., Oz, M. C., et al. (1994). Artificial circulatory support with textured interior surfaces: a counterintuitive approach to minimize thromboembolism. Circulation, 90(5 pt 2), II87–91.PubMed
12.
go back to reference John, R., Kamdar, F., Liao, K., et al. (2008). Low thromboembolic risk with the HeartMate II left ventricular assist device. Journal of thoracic and cardiovascular surgery, 136, 1318–1323.PubMedCrossRef John, R., Kamdar, F., Liao, K., et al. (2008). Low thromboembolic risk with the HeartMate II left ventricular assist device. Journal of thoracic and cardiovascular surgery, 136, 1318–1323.PubMedCrossRef
13.
go back to reference Letsou, G. V., Shah, N., Gregoric, I. D., et al. (2005). Gastrointestinal bleeding from arteriovenous malformations in patients supported by the Jarvik 2000 axial-flow left ventricular assist device. Journal of Heart and Lung Transplantation, 24, 105–109.PubMedCrossRef Letsou, G. V., Shah, N., Gregoric, I. D., et al. (2005). Gastrointestinal bleeding from arteriovenous malformations in patients supported by the Jarvik 2000 axial-flow left ventricular assist device. Journal of Heart and Lung Transplantation, 24, 105–109.PubMedCrossRef
14.
go back to reference Crow, S., John, R., Boyle, A., et al. (2009). Gastrointestinal bleeding rates in recipients of non-pulsatile and pulsatile left ventricular assist devices. Journal of Thoracic and Cardiovascular Surgery, 137, 208–215.PubMedCrossRef Crow, S., John, R., Boyle, A., et al. (2009). Gastrointestinal bleeding rates in recipients of non-pulsatile and pulsatile left ventricular assist devices. Journal of Thoracic and Cardiovascular Surgery, 137, 208–215.PubMedCrossRef
15.
go back to reference Heyde, E. C. (1958). Gastrointestinal bleeding in aortic stenosis (letter). New England Journal of Medicine, 259, 196. Heyde, E. C. (1958). Gastrointestinal bleeding in aortic stenosis (letter). New England Journal of Medicine, 259, 196.
16.
go back to reference Boley, S. J., Sammarteno, R., Adams A., et al. (1977). Vascular ectasias of the colon. On the nature and etiology of vascular ectasias of the colon. Gastroenterolgy, 72, 650–660. Boley, S. J., Sammarteno, R., Adams A., et al. (1977). Vascular ectasias of the colon. On the nature and etiology of vascular ectasias of the colon. Gastroenterolgy, 72, 650–660.
17.
go back to reference Warkentin, T. E., Moore, J. C., & Morgan, D. G. (1992). Aortic stenosis and bleeding gastrointestinal angiodysplasia: is acquired von Willebrand’s disease the link? Lancet, 340, 35–37.PubMedCrossRef Warkentin, T. E., Moore, J. C., & Morgan, D. G. (1992). Aortic stenosis and bleeding gastrointestinal angiodysplasia: is acquired von Willebrand’s disease the link? Lancet, 340, 35–37.PubMedCrossRef
18.
go back to reference Furlan, M. (1996). von Willebrand factor: molecular size and functional activity. Annals of Hematology, 72, 341–348.PubMedCrossRef Furlan, M. (1996). von Willebrand factor: molecular size and functional activity. Annals of Hematology, 72, 341–348.PubMedCrossRef
19.
20.
go back to reference Vincentelli, A., Susen, S., Le Tourneau, T., Six, I., Fabre, O., Juthier, F., et al. (2003). Acquired von Willebrand syndrome in aortic stenosis. New England Journal of Medicine, 349, 343–349.PubMedCrossRef Vincentelli, A., Susen, S., Le Tourneau, T., Six, I., Fabre, O., Juthier, F., et al. (2003). Acquired von Willebrand syndrome in aortic stenosis. New England Journal of Medicine, 349, 343–349.PubMedCrossRef
21.
go back to reference Geisen, U., Heilmann, C., Beyersdorf, F., et al. (2008). Non-surgical bleeding in patients with ventricular assist devices could be explained by acquired von Willebrand disease. European Journal of Cardiothoracic Surgery, 22, 679–684.CrossRef Geisen, U., Heilmann, C., Beyersdorf, F., et al. (2008). Non-surgical bleeding in patients with ventricular assist devices could be explained by acquired von Willebrand disease. European Journal of Cardiothoracic Surgery, 22, 679–684.CrossRef
22.
go back to reference Weslowski, S., Fisher, J., & Welch, C. (1953). Perfusion of the pulmonary circulation by non-pulsatile flow. Surgery, 33, 370. Weslowski, S., Fisher, J., & Welch, C. (1953). Perfusion of the pulmonary circulation by non-pulsatile flow. Surgery, 33, 370.
23.
go back to reference Johnston, G. G., Hammill, F., Marzec, U., et al. (1976). Prolonged pulseless perfusion in unanesthetized calves. Archives of Surgery, 111, 1125–1130. Johnston, G. G., Hammill, F., Marzec, U., et al. (1976). Prolonged pulseless perfusion in unanesthetized calves. Archives of Surgery, 111, 1125–1130.
24.
go back to reference Saito, S., Westaby, S., Piggot, D., et al. (2002). End-organ function during chronic nonpulsatile circulation. Annals of Thoracic Surgery, 74, 1080–1085.PubMedCrossRef Saito, S., Westaby, S., Piggot, D., et al. (2002). End-organ function during chronic nonpulsatile circulation. Annals of Thoracic Surgery, 74, 1080–1085.PubMedCrossRef
25.
go back to reference Nakata, K., Shiono, M., Orime, Y., et al. (1996). Effect of pulsatile and nonpulsatile assist on heart and kidney microcirculation with cardiogenic shock. Artificial Organs, 20, 681–684.PubMedCrossRef Nakata, K., Shiono, M., Orime, Y., et al. (1996). Effect of pulsatile and nonpulsatile assist on heart and kidney microcirculation with cardiogenic shock. Artificial Organs, 20, 681–684.PubMedCrossRef
26.
go back to reference Letsou, G. V., Myers, T. J., Gregoric, I. D., et al. (2003). Continuous axial-flow left ventricular assist device (Jarvik 2000) maintains kidney and liver perfusion for up to 6 months. Annals of Thoracic Surgery, 76, 1167–1170.PubMedCrossRef Letsou, G. V., Myers, T. J., Gregoric, I. D., et al. (2003). Continuous axial-flow left ventricular assist device (Jarvik 2000) maintains kidney and liver perfusion for up to 6 months. Annals of Thoracic Surgery, 76, 1167–1170.PubMedCrossRef
27.
go back to reference Radovancevic, B., Vrtovec, B., de Kort, E., Radovancevic, R., Gregoric, I. D., & Frazier, O. H. (2007). End-organ function in patients on long-term circulatory support with continuous or pulsatile-flow assist devices. Journal of Heart Transplantation, 26(8), 815–818.CrossRef Radovancevic, B., Vrtovec, B., de Kort, E., Radovancevic, R., Gregoric, I. D., & Frazier, O. H. (2007). End-organ function in patients on long-term circulatory support with continuous or pulsatile-flow assist devices. Journal of Heart Transplantation, 26(8), 815–818.CrossRef
28.
go back to reference Kamdar, F., Boyle, A., Liao, K., Colvin-Adams, M., Joyce, L., John, R. (2009). Effects of centrifugal, axial and pulsatile left ventricular assist device (LVAD) support on end-organ function in heart failure patients. Journal of Heart and Lung Transplantation (in press). Kamdar, F., Boyle, A., Liao, K., Colvin-Adams, M., Joyce, L., John, R. (2009). Effects of centrifugal, axial and pulsatile left ventricular assist device (LVAD) support on end-organ function in heart failure patients. Journal of Heart and Lung Transplantation (in press).
29.
go back to reference Klotz, S., Deng, M. C., Stymann, J., et al. (2004). Left ventricular pressure and volume unloading during pulsatile versus nonpulsatile left ventricular assist device support. Annals of Thoracic Surgery, 77, 143–150.PubMedCrossRef Klotz, S., Deng, M. C., Stymann, J., et al. (2004). Left ventricular pressure and volume unloading during pulsatile versus nonpulsatile left ventricular assist device support. Annals of Thoracic Surgery, 77, 143–150.PubMedCrossRef
30.
go back to reference Haft, J., Armstrong, W., Dyke, D. B., et al. (2007). Hemodynamic and exercise performance with pulsatile and continuous-flow left ventricular assist devices. Circulation, 116, I–8–15.CrossRef Haft, J., Armstrong, W., Dyke, D. B., et al. (2007). Hemodynamic and exercise performance with pulsatile and continuous-flow left ventricular assist devices. Circulation, 116, I–8–15.CrossRef
31.
go back to reference Thohan, V., Stetson, S. J., Nagueh, S. F., et al. (2005). Cellular and hemodynamic responses of failing myocardium to continuous flow mechanical circulatory support using the DeBakey-Noon left ventricular assist device: a comparative analysis with pulsatile-type devices. Journal of Heart Transplantation, 24, 566–575.CrossRef Thohan, V., Stetson, S. J., Nagueh, S. F., et al. (2005). Cellular and hemodynamic responses of failing myocardium to continuous flow mechanical circulatory support using the DeBakey-Noon left ventricular assist device: a comparative analysis with pulsatile-type devices. Journal of Heart Transplantation, 24, 566–575.CrossRef
32.
go back to reference Garcia, S., Kamdar, F., Boyle, A., et al. (2008). Effects of pulsatile- and continuous-flow left ventricular assist devices on left ventricular unloading. Journal of Heart Transplantation, 27, 261–267.CrossRef Garcia, S., Kamdar, F., Boyle, A., et al. (2008). Effects of pulsatile- and continuous-flow left ventricular assist devices on left ventricular unloading. Journal of Heart Transplantation, 27, 261–267.CrossRef
33.
go back to reference Etz, C. D., Welp, H. A., Tjan, T. D., et al. (2007). Medically refractory pulmonary hypertension: treatment with nonpulsatile left ventricular assist devices. Annals of Thoracic Surgery, 83, 1697–1706.PubMedCrossRef Etz, C. D., Welp, H. A., Tjan, T. D., et al. (2007). Medically refractory pulmonary hypertension: treatment with nonpulsatile left ventricular assist devices. Annals of Thoracic Surgery, 83, 1697–1706.PubMedCrossRef
34.
go back to reference Cao, X., Haft, J., Dyke, D. B., et al. Increased incidence of ventricular tachycardia following left ventricular assist device implantation with continuous flow rotary pumps. Presented at 10th Annual Scientific Meeting of the Heart Failure Society of America, Sep 2006, Seattle, WA. Cao, X., Haft, J., Dyke, D. B., et al. Increased incidence of ventricular tachycardia following left ventricular assist device implantation with continuous flow rotary pumps. Presented at 10th Annual Scientific Meeting of the Heart Failure Society of America, Sep 2006, Seattle, WA.
35.
go back to reference Vollkron, M., Voitl, P., Ta, J., et al. (2007). Suction events during left ventricular and ventricular arrhythmias. Journal of Heart Transplantation, 26, 819–825.CrossRef Vollkron, M., Voitl, P., Ta, J., et al. (2007). Suction events during left ventricular and ventricular arrhythmias. Journal of Heart Transplantation, 26, 819–825.CrossRef
36.
go back to reference Wu, Yi., Allaire, P., Tao, G., et al. (2003). An advanced physiological controller design for a left ventricular assist device to prevent left ventricular collapse. Artificial Organs, 10, 926–930.CrossRef Wu, Yi., Allaire, P., Tao, G., et al. (2003). An advanced physiological controller design for a left ventricular assist device to prevent left ventricular collapse. Artificial Organs, 10, 926–930.CrossRef
37.
go back to reference Vollkron, M., Schima, H., Huber, L., et al. (2006). Advanced suction detection for an axial flow pump. Artificial Organs, 9, 665–670.CrossRef Vollkron, M., Schima, H., Huber, L., et al. (2006). Advanced suction detection for an axial flow pump. Artificial Organs, 9, 665–670.CrossRef
Metadata
Title
Physiologic and Pathologic Changes in Patients with Continuous-Flow Ventricular Assist Devices
Authors
Ranjit John
Andrew Boyle
Frank Pagani
Leslie Miller
Publication date
01-06-2009
Publisher
Springer US
Published in
Journal of Cardiovascular Translational Research / Issue 2/2009
Print ISSN: 1937-5387
Electronic ISSN: 1937-5395
DOI
https://doi.org/10.1007/s12265-009-9092-y

Other articles of this Issue 2/2009

Journal of Cardiovascular Translational Research 2/2009 Go to the issue