Monte Carlo modeling of a conventional X-ray computed tomography scanner for gel dosimetry purposes

Authors: Homa Hayati, Asghar Mesbahi, Mahmood Nazarpoor

Published in: Radiological Physics and Technology | Issue 1/2016

Login to get access

Abstract

Our purpose in the current study was to model an X-ray CT scanner with the Monte Carlo (MC) method for gel dosimetry. In this study, a conventional CT scanner with one array detector was modeled with use of the MCNPX MC code. The MC calculated photon fluence in detector arrays was used for image reconstruction of a simple water phantom as well as polyacrylamide polymer gel (PAG) used for radiation therapy. Image reconstruction was performed with the filtered back-projection method with a Hann filter and the Spline interpolation method. Using MC results, we obtained the dose–response curve for images of irradiated gel at different absorbed doses. A spatial resolution of about 2 mm was found for our simulated MC model. The MC-based CT images of the PAG gel showed a reliable increase in the CT number with increasing absorbed dose for the studied gel. Also, our results showed that the current MC model of a CT scanner can be used for further studies on the parameters that influence the usability and reliability of results, such as the photon energy spectra and exposure techniques in X-ray CT gel dosimetry.
Literature
1.
go back to reference Angel E, Yaghmai N, Jude CM, DeMarco JJ, Cagnon CH, Goldin JG, Primak AN, Stevens DM, Cody DD, McCollough CH, McNitt-Gray MF. Monte Carlo simulations to assess the effects of tube current modulation on breast dose for multidetector CT. Phys Med Biol. 2009;54:497–512.PubMedCentralCrossRefPubMed Angel E, Yaghmai N, Jude CM, DeMarco JJ, Cagnon CH, Goldin JG, Primak AN, Stevens DM, Cody DD, McCollough CH, McNitt-Gray MF. Monte Carlo simulations to assess the effects of tube current modulation on breast dose for multidetector CT. Phys Med Biol. 2009;54:497–512.PubMedCentralCrossRefPubMed
2.
go back to reference Audet C, Hilts M, Jirasek A, Duzenli C. CT gel dosimetry technique: comparison of a planned and measured 3D stereotactic dose volume. J. Appl. Clin. Med. Phys. 2002;3:110–8.CrossRefPubMed Audet C, Hilts M, Jirasek A, Duzenli C. CT gel dosimetry technique: comparison of a planned and measured 3D stereotactic dose volume. J. Appl. Clin. Med. Phys. 2002;3:110–8.CrossRefPubMed
3.
go back to reference Aviles LP, Dance DR, Castellano IA, Vano E. Monte Carlo simulations in CT for the study of the surface air kerma and energy imparted to phantoms of varying size and position. Phys Med Biol. 2004;49:1439–54.CrossRef Aviles LP, Dance DR, Castellano IA, Vano E. Monte Carlo simulations in CT for the study of the surface air kerma and energy imparted to phantoms of varying size and position. Phys Med Biol. 2004;49:1439–54.CrossRef
4.
go back to reference Ay MR, Zaidi H. Development and validation of MCNP4C-based Monte Carlo simulator for fan- and cone-beam X-ray CT. Phys Med Biol. 2005;50:4863–85.CrossRefPubMed Ay MR, Zaidi H. Development and validation of MCNP4C-based Monte Carlo simulator for fan- and cone-beam X-ray CT. Phys Med Biol. 2005;50:4863–85.CrossRefPubMed
6.
go back to reference Colijn AP, Zbijewski W, Sasov A, Beekman FJ. Experimental validation of a rapid Monte Carlo based micro-CT simulator. Phys Med Biol. 2004;49:4321–33.CrossRefPubMed Colijn AP, Zbijewski W, Sasov A, Beekman FJ. Experimental validation of a rapid Monte Carlo based micro-CT simulator. Phys Med Biol. 2004;49:4321–33.CrossRefPubMed
9.
go back to reference Seeram E. Data acquisition concept. In: Anonymous computed tomography: physical principles, clinical applications, and quality control. Philadelphia: W.B. Saunders Company; 2001. Seeram E. Data acquisition concept. In: Anonymous computed tomography: physical principles, clinical applications, and quality control. Philadelphia: W.B. Saunders Company; 2001.
10.
go back to reference Ghavami SM, Mesbahi A, Pesianian I, Shafaee A, Aliparasti MR. Normoxic polymer gel dosimetry using less toxic monomer of N-isopropyl acrylamide and X-ray computed tomography for radiation therapy applications. Rep Pract Oncol Radiother. 2010;15:172–5.PubMedCentralCrossRefPubMed Ghavami SM, Mesbahi A, Pesianian I, Shafaee A, Aliparasti MR. Normoxic polymer gel dosimetry using less toxic monomer of N-isopropyl acrylamide and X-ray computed tomography for radiation therapy applications. Rep Pract Oncol Radiother. 2010;15:172–5.PubMedCentralCrossRefPubMed
11.
go back to reference Hilts M, Duzenli C. Image filtering for improved dose resolution in CT polymer gel dosimetry. Med Phys. 2004;31:39–49.CrossRefPubMed Hilts M, Duzenli C. Image filtering for improved dose resolution in CT polymer gel dosimetry. Med Phys. 2004;31:39–49.CrossRefPubMed
12.
go back to reference Hilts M, Jirasek A. Adaptive mean filtering for noise reduction in CT polymer gel dosimetry. Med Phys. 2008;35:344–55.CrossRefPubMed Hilts M, Jirasek A. Adaptive mean filtering for noise reduction in CT polymer gel dosimetry. Med Phys. 2008;35:344–55.CrossRefPubMed
13.
go back to reference Hilts M, Jirasek A, Duzenli C. Effects of gel composition on the radiation induced density change in PAG polymer gel dosimeters: a model and experimental investigations. Phys Med Biol. 2004;49:2477–90.CrossRefPubMed Hilts M, Jirasek A, Duzenli C. Effects of gel composition on the radiation induced density change in PAG polymer gel dosimeters: a model and experimental investigations. Phys Med Biol. 2004;49:2477–90.CrossRefPubMed
14.
go back to reference Hilts M, Jirasek A, Duzenli C. Technical considerations for implementation of X-ray CT polymer gel dosimetry. Phys Med Biol. 2005;50:1727–45.CrossRefPubMed Hilts M, Jirasek A, Duzenli C. Technical considerations for implementation of X-ray CT polymer gel dosimetry. Phys Med Biol. 2005;50:1727–45.CrossRefPubMed
15.
go back to reference Hindmarsh J, Fulton R, Oliver L, Baldock C. Polymer gel dosimetry using X-ray computed tomography: investigation of the effect of reconstruction technique. Phys. Conf. Ser. 2010; 250:012073-1–5. Hindmarsh J, Fulton R, Oliver L, Baldock C. Polymer gel dosimetry using X-ray computed tomography: investigation of the effect of reconstruction technique. Phys. Conf. Ser. 2010; 250:012073-1–5.
16.
go back to reference Ibbott GS, Maryanski MJ, Eastman P, Holcomb SD, Zhang Y, Avison RG, Sanders M, Gore JC. Three-dimensional visualization and measurement of conformal dose distributions using magnetic resonance imaging of BANG polymer gel dosimeters. Int J Radiat Oncol Biol Phys. 1997;38:1097–103.CrossRefPubMed Ibbott GS, Maryanski MJ, Eastman P, Holcomb SD, Zhang Y, Avison RG, Sanders M, Gore JC. Three-dimensional visualization and measurement of conformal dose distributions using magnetic resonance imaging of BANG polymer gel dosimeters. Int J Radiat Oncol Biol Phys. 1997;38:1097–103.CrossRefPubMed
17.
go back to reference Jarry G, DeMarco JJ, Beifuss U, Cagnon CH, McNitt-Gray MF. A Monte Carlo-based method to estimate radiation dose from spiral CT: from phantom testing to patient-specific models. Phys Med Biol. 2003;48:2645–63.CrossRefPubMed Jarry G, DeMarco JJ, Beifuss U, Cagnon CH, McNitt-Gray MF. A Monte Carlo-based method to estimate radiation dose from spiral CT: from phantom testing to patient-specific models. Phys Med Biol. 2003;48:2645–63.CrossRefPubMed
18.
go back to reference Jirasek A, Hilts M, McAuley KB. Polymer gel dosimeters with enhanced sensitivity for use in X-ray CT polymer gel dosimetry. Phys Med Biol. 2010;55:5269–81.CrossRefPubMed Jirasek A, Hilts M, McAuley KB. Polymer gel dosimeters with enhanced sensitivity for use in X-ray CT polymer gel dosimetry. Phys Med Biol. 2010;55:5269–81.CrossRefPubMed
19.
go back to reference Lee SC, Kim HK, Chun IK, Cho MH, Lee SY, Cho MH. A flat-panel detector based micro-CT system: performance evaluation for small-animal imaging. Phys Med Biol. 2003;48:4173–85.CrossRefPubMed Lee SC, Kim HK, Chun IK, Cho MH, Lee SY, Cho MH. A flat-panel detector based micro-CT system: performance evaluation for small-animal imaging. Phys Med Biol. 2003;48:4173–85.CrossRefPubMed
20.
go back to reference Tofts PS, Gore JC. Some sources of artefact in computed tomography. Phys Med Biol. 1980;25:117–27.CrossRefPubMed Tofts PS, Gore JC. Some sources of artefact in computed tomography. Phys Med Biol. 1980;25:117–27.CrossRefPubMed
21.
go back to reference Trapp JV, Michael G, De DY, Baldock C. Attenuation of diagnostic energy photons by polymer gel dosimeters. Phys Med Biol. 2002;47:4247–58.CrossRefPubMed Trapp JV, Michael G, De DY, Baldock C. Attenuation of diagnostic energy photons by polymer gel dosimeters. Phys Med Biol. 2002;47:4247–58.CrossRefPubMed
Metadata
Title
Monte Carlo modeling of a conventional X-ray computed tomography scanner for gel dosimetry purposes
Authors
Homa Hayati
Asghar Mesbahi
Mahmood Nazarpoor
Publication date
01-01-2016
Publisher
Springer Japan
Published in
Radiological Physics and Technology / Issue 1/2016
Print ISSN: 1865-0333
Electronic ISSN: 1865-0341
DOI
https://doi.org/10.1007/s12194-015-0331-4

Other articles of this Issue 1/2016

Radiological Physics and Technology 1/2016 Go to the issue