Skip to main content
Top
Published in: Neurocritical Care 3/2014

01-12-2014 | Original Article

Completing the Apnea Test: Decline in Complications

Authors: Sudhir Datar, Jennifer Fugate, Alejandro Rabinstein, Philippe Couillard, Eelco F. M. Wijdicks

Published in: Neurocritical Care | Issue 3/2014

Login to get access

Abstract

Introduction

The apnea test is a crucial component of the clinical diagnosis of brain death. Apprehension about hypoxemia, hypotension, and/or cardiac arrhythmias may sometimes lead clinicians to avoid performing or prematurely terminate the apnea test. The purpose of this study was to perform a contemporary re-evaluation of the safety of the apnea test.

Methods

We performed a detailed chart review of consecutive brain dead patients who underwent an apnea test from 2008 to 2012.

Results

Out of 63 patients, 33 were men (52.4 %). Mean age was 46.4 years. In all but four patients (93.7 %), the apnea test was performed by a neurointensivist. Infiltrates on chest radiographs were present in 34 (54 %). Seven patients (11.1 %) had chest tubes, six of which were associated with polytrauma. Echocardiograms were obtained in 47 patients (74.6 %), and 18 patients (38.3 %) had regional wall motion abnormalities (IQR 41–65 %). Fifty patients (79.4 %) were on vasopressors prior to apnea test. Median FiO2 was 0.5 (IQR 0.4–0.6), and PEEP was 5 cm H2O (IQR 5–10). After apnea test, median pO2 was 306 mmHg (IQR 121–389). Apnea test was aborted in only one patient; this patient had required FiO2 0.9–1.0 prior to the test and desaturated during the test. Mild hypoxemia occurred in three others without any consequences. Mild hypotension occurred in 11 patients (17.4 %) and was easily managed by an increase in the vasopressor infusion. There were no instances of major cardiac arrhythmias.

Conclusion

Apnea determined using the oxygenation diffusion method during brain death testing is very safe, provided appropriate prerequisites are met. We found a major decrease in the number of aborted or not attempted apnea tests compared to previous studies.
Literature
1.
go back to reference Practice parameters for determining brain death in adults (summary statement). The quality standards subcommittee of the American Academy of Neurology. Neurology. 1995;45(5):1012–4. Practice parameters for determining brain death in adults (summary statement). The quality standards subcommittee of the American Academy of Neurology. Neurology. 1995;45(5):1012–4.
2.
go back to reference Wijdicks EF, et al. Evidence-based guideline update: determining brain death in adults: report of the quality standards subcommittee of the American Academy of Neurology. Neurology. 2010;74(23):1911–8.PubMedCrossRef Wijdicks EF, et al. Evidence-based guideline update: determining brain death in adults: report of the quality standards subcommittee of the American Academy of Neurology. Neurology. 2010;74(23):1911–8.PubMedCrossRef
3.
go back to reference Jeret JS, Benjamin JL. Risk of hypotension during apnea testing. Arch Neurol. 1994;51(8198471):595–9.PubMedCrossRef Jeret JS, Benjamin JL. Risk of hypotension during apnea testing. Arch Neurol. 1994;51(8198471):595–9.PubMedCrossRef
4.
go back to reference Bar-Joseph G, Bar-Lavie Y, Zonis Z. Tension pneumothorax during apnea testing for the determination of brain death. Anesthesiology. 1998;89(9822015):1250–1.PubMedCrossRef Bar-Joseph G, Bar-Lavie Y, Zonis Z. Tension pneumothorax during apnea testing for the determination of brain death. Anesthesiology. 1998;89(9822015):1250–1.PubMedCrossRef
5.
go back to reference Burns JD, Russell JA. Tension pneumothorax complicating apnea testing during brain death evaluation. J Clin Neurosci Off J Neurosurg Soc Australas. 2008;15(5):580–2. Burns JD, Russell JA. Tension pneumothorax complicating apnea testing during brain death evaluation. J Clin Neurosci Off J Neurosurg Soc Australas. 2008;15(5):580–2.
6.
go back to reference Goudreau JL, Wijdicks EF, Emery SF. Complications during apnea testing in the determination of brain death: predisposing factors. Neurology. 2000;55(7):1045–8.PubMedCrossRef Goudreau JL, Wijdicks EF, Emery SF. Complications during apnea testing in the determination of brain death: predisposing factors. Neurology. 2000;55(7):1045–8.PubMedCrossRef
7.
go back to reference Saposnik G, et al. Problems associated with the apnea test in the diagnosis of brain death. Neurol India. 2004;52(15472423):342–5.PubMed Saposnik G, et al. Problems associated with the apnea test in the diagnosis of brain death. Neurol India. 2004;52(15472423):342–5.PubMed
8.
go back to reference Wijdicks EFM, et al. Pronouncing brain death: contemporary practice and safety of the apnea test. Neurology. 2008;71(18852438):1240–4.PubMedCrossRef Wijdicks EFM, et al. Pronouncing brain death: contemporary practice and safety of the apnea test. Neurology. 2008;71(18852438):1240–4.PubMedCrossRef
10.
go back to reference Yee AH, et al. Predictors of apnea test failure during brain death determination. Neurocrit Care. 2010;12(20217276):352–5.PubMedCrossRef Yee AH, et al. Predictors of apnea test failure during brain death determination. Neurocrit Care. 2010;12(20217276):352–5.PubMedCrossRef
Metadata
Title
Completing the Apnea Test: Decline in Complications
Authors
Sudhir Datar
Jennifer Fugate
Alejandro Rabinstein
Philippe Couillard
Eelco F. M. Wijdicks
Publication date
01-12-2014
Publisher
Springer US
Published in
Neurocritical Care / Issue 3/2014
Print ISSN: 1541-6933
Electronic ISSN: 1556-0961
DOI
https://doi.org/10.1007/s12028-014-9958-y

Other articles of this Issue 3/2014

Neurocritical Care 3/2014 Go to the issue