Ultrasound-guided fine needle aspiration versus core needle biopsy: comparison of post-biopsy hematoma rates and risk factors

Authors: In Hye Chae, Eun-Kyung Kim, Hee Jung Moon, Jung Hyun Yoon, Vivian Y. Park, Jin Young Kwak

Published in: Endocrine | Issue 1/2017

Login to get access

Abstract

Purpose

To compare post-biopsy hematoma rates between ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy, and to investigate risk factors for post-biopsy hematoma.

Methods

A total of 5304 thyroid nodules which underwent ultrasound guided biopsy were included in this retrospective study. We compared clinical and US features between patients with and without post-biopsy hematoma. Associations between these features and post-biopsy hematoma were analyzed.

Results

Post-biopsy hematoma rate was 0.8% (43/5121) for ultrasound guided-fine needle aspiration and 4.9% (9/183) for ultrasound guided-core needle biopsy (P < 0.001). For ultrasound guided-fine needle aspiration, gender, age, size, presence of vascularity, and suspicious US features were not associated with post-biopsy hematoma according to experience level. Post-biopsy hematoma occurred significantly more with ultrasound guided-core needle biopsy (9/179, 5.0%) than with ultrasound guided-fine needle aspiration (9/1138, 0.8%) (P < 0.001) in experienced performers and ultrasound guided-core needle biopsy was the only significant risk factor for post-biopsy hematoma (adjusted Odds Ratio, 6.458, P < 0.001).

Conclusion

Post-biopsy hematoma occurred significantly more in ultrasound guided-core needle biopsy than in ultrasound guided-fine needle aspiration and ultrasound guided-core needle biopsy was the only independent factor of post-biopsy hematoma in thyroid nodules.
Literature
1.
go back to reference B.R.M. Haugen, E.K. Alexander, K.C. Bible, G. Doherty, S.J. Mandel, Y.E. Nikiforov, F. Pacini, G. Randolph, A. Sawka, M. Schlumberger, K.G. Schuff, S.I. Sherman, J.A. Sosa, D. Steward, R.M.M. Tuttle, L. Wartofsky, 2015 American thyroid association management guidelines for adult patients with thyroid nodules and differentiated thyroid cancer. Thyroid 26(1), 1–133 (2015)CrossRef B.R.M. Haugen, E.K. Alexander, K.C. Bible, G. Doherty, S.J. Mandel, Y.E. Nikiforov, F. Pacini, G. Randolph, A. Sawka, M. Schlumberger, K.G. Schuff, S.I. Sherman, J.A. Sosa, D. Steward, R.M.M. Tuttle, L. Wartofsky, 2015 American thyroid association management guidelines for adult patients with thyroid nodules and differentiated thyroid cancer. Thyroid 26(1), 1–133 (2015)CrossRef
2.
go back to reference J.H. Yoon, H.J. Moon, E.K. Kim, J.Y. Kwak, Inadequate cytology in thyroid nodules: should we repeat aspiration or follow-up? Ann. Surg. Oncol. 18(5), 1282–1289 (2011)CrossRef J.H. Yoon, H.J. Moon, E.K. Kim, J.Y. Kwak, Inadequate cytology in thyroid nodules: should we repeat aspiration or follow-up? Ann. Surg. Oncol. 18(5), 1282–1289 (2011)CrossRef
3.
go back to reference J.H. Yoon, E.K. Kim, J.Y. Kwak, H.J. Moon, Effectiveness and limitations of core needle biopsy in the diagnosis of thyroid nodules: review of current literature. J. Pathol. Transl. Med. 49(3), 230–235 (2015)CrossRef J.H. Yoon, E.K. Kim, J.Y. Kwak, H.J. Moon, Effectiveness and limitations of core needle biopsy in the diagnosis of thyroid nodules: review of current literature. J. Pathol. Transl. Med. 49(3), 230–235 (2015)CrossRef
4.
go back to reference A.C. Nachiappan, Z.A. Metwalli, B.S. Hailey, R.A. Patel, M.L. Ostrowski, D.M. Wynne, The thyroid: review of imaging features and biopsy techniques with radiologic-pathologic correlation. Radiographics 34(2), 276–293 (2014)CrossRef A.C. Nachiappan, Z.A. Metwalli, B.S. Hailey, R.A. Patel, M.L. Ostrowski, D.M. Wynne, The thyroid: review of imaging features and biopsy techniques with radiologic-pathologic correlation. Radiographics 34(2), 276–293 (2014)CrossRef
5.
go back to reference H. Gharib, E. Papini, R. Paschke, D.S. Duick, R. Valcavi, L. Hegedus, P. Vitti, American association of clinical endocrinologists, associazione medici endocrinologi, and European thyroid association medical guidelines for clinical practice for the diagnosis and management of thyroid nodules: executive summary of recommendations. J. Endocrinol. Invest. 33(5 Suppl), 51–56 (2010)PubMed H. Gharib, E. Papini, R. Paschke, D.S. Duick, R. Valcavi, L. Hegedus, P. Vitti, American association of clinical endocrinologists, associazione medici endocrinologi, and European thyroid association medical guidelines for clinical practice for the diagnosis and management of thyroid nodules: executive summary of recommendations. J. Endocrinol. Invest. 33(5 Suppl), 51–56 (2010)PubMed
6.
go back to reference Y.H. Kim, H.J. Kwon, E.K. Kim, J.Y. Kwak, H.J. Moon, J.H. Yoon, Applying ultrasound-guided core needle biopsy for diagnosis of thyroid masses: preliminary results from a single institution. J. Ultrasound. Med. 34(10), 1801–1808 (2015)CrossRef Y.H. Kim, H.J. Kwon, E.K. Kim, J.Y. Kwak, H.J. Moon, J.H. Yoon, Applying ultrasound-guided core needle biopsy for diagnosis of thyroid masses: preliminary results from a single institution. J. Ultrasound. Med. 34(10), 1801–1808 (2015)CrossRef
7.
go back to reference E. Novoa, N. Gurtler, A. Arnoux, M. Kraft, Role of ultrasound-guided core-needle biopsy in the assessment of head and neck lesions: a meta-analysis and systematic review of the literature. Head Neck 34(10), 1497–1503 (2012)CrossRef E. Novoa, N. Gurtler, A. Arnoux, M. Kraft, Role of ultrasound-guided core-needle biopsy in the assessment of head and neck lesions: a meta-analysis and systematic review of the literature. Head Neck 34(10), 1497–1503 (2012)CrossRef
8.
go back to reference B.T. Chen, A.B. Jain, A. Dagis, P. Chu, L. Vora, E. Maghami, B. Salehian, Comparison of the efficacy and safety of ultrasound-guided core needle biopsy versus fine-needle aspiration for evaluating thyroid nodules. Endocr. Pract. 21(2), 128–135 (2015)CrossRef B.T. Chen, A.B. Jain, A. Dagis, P. Chu, L. Vora, E. Maghami, B. Salehian, Comparison of the efficacy and safety of ultrasound-guided core needle biopsy versus fine-needle aspiration for evaluating thyroid nodules. Endocr. Pract. 21(2), 128–135 (2015)CrossRef
9.
go back to reference E.J. Ha, J.H. Baek, J.H. Lee, J.K. Kim, Y.J. Choi, T.Y. Sung, T.Y. Kim, Complications following US-guided core-needle biopsy for thyroid lesions: a retrospective study of 6,169 consecutive patients with 6,687 thyroid nodules. Eur. Radiol. 27(3), 1–9 (2016) E.J. Ha, J.H. Baek, J.H. Lee, J.K. Kim, Y.J. Choi, T.Y. Sung, T.Y. Kim, Complications following US-guided core-needle biopsy for thyroid lesions: a retrospective study of 6,169 consecutive patients with 6,687 thyroid nodules. Eur. Radiol. 27(3), 1–9 (2016)
10.
go back to reference T.K. Khoo, C.H. Baker, J. Hallanger-Johnson, A.M. Tom, C.S. Grant, C.C. Reading, T.J. Sebo, J.C. Morris, 3rd: comparison of ultrasound-guided fine-needle aspiration biopsy with core-needle biopsy in the evaluation of thyroid nodules. Endocr. Pract. 14(4), 426–431 (2008)CrossRef T.K. Khoo, C.H. Baker, J. Hallanger-Johnson, A.M. Tom, C.S. Grant, C.C. Reading, T.J. Sebo, J.C. Morris, 3rd: comparison of ultrasound-guided fine-needle aspiration biopsy with core-needle biopsy in the evaluation of thyroid nodules. Endocr. Pract. 14(4), 426–431 (2008)CrossRef
11.
go back to reference M. Bergeron, D. Beaudoin, Simple core-needle biopsy for thyroid nodule, complicated tinnitus. Eur. Thyroid. J. 3(2), 130–133 (2014)CrossRef M. Bergeron, D. Beaudoin, Simple core-needle biopsy for thyroid nodule, complicated tinnitus. Eur. Thyroid. J. 3(2), 130–133 (2014)CrossRef
12.
go back to reference S.A. Polyzos, A.D. Anastasilakis, Clinical complications following thyroid fine-needle biopsy: a systematic review. Clin. Endocrinol. 71(2), 157–165 (2009)CrossRef S.A. Polyzos, A.D. Anastasilakis, Clinical complications following thyroid fine-needle biopsy: a systematic review. Clin. Endocrinol. 71(2), 157–165 (2009)CrossRef
13.
go back to reference J.N. Harvey, D. Parker, P. De, R.K. Shrimali, M. Otter, Sonographically guided core biopsy in the assessment of thyroid nodules. J. Clin. Ultrasound. 33(2), 57–62 (2005)CrossRef J.N. Harvey, D. Parker, P. De, R.K. Shrimali, M. Otter, Sonographically guided core biopsy in the assessment of thyroid nodules. J. Clin. Ultrasound. 33(2), 57–62 (2005)CrossRef
14.
go back to reference K.A. Newkirk, M.D. Ringel, J. Jelinek, A. Mark, L. Wartofsky, Z.E. Deeb, R.B. Sessions, K.D. Burman, Ultrasound-guided fine-needle aspiration and thyroid disease. Otolaryngol. Head Neck Surg. 123(6), 700–705 (2000)CrossRef K.A. Newkirk, M.D. Ringel, J. Jelinek, A. Mark, L. Wartofsky, Z.E. Deeb, R.B. Sessions, K.D. Burman, Ultrasound-guided fine-needle aspiration and thyroid disease. Otolaryngol. Head Neck Surg. 123(6), 700–705 (2000)CrossRef
15.
go back to reference M. Braga, T.C. Cavalcanti, L.M. Collaco, H. Graf, Efficacy of ultrasound-guided fine-needle aspiration biopsy in the diagnosis of complex thyroid nodules. J. Clin. Endocrinol. Metab. 86(9), 4089–4091 (2001)CrossRef M. Braga, T.C. Cavalcanti, L.M. Collaco, H. Graf, Efficacy of ultrasound-guided fine-needle aspiration biopsy in the diagnosis of complex thyroid nodules. J. Clin. Endocrinol. Metab. 86(9), 4089–4091 (2001)CrossRef
16.
go back to reference J.L. Roh, Intrathyroid hemorrhage and acute upper airway obstruction after fine needle aspiration of the thyroid gland. Laryngoscope 116(1), 154–156 (2006)CrossRef J.L. Roh, Intrathyroid hemorrhage and acute upper airway obstruction after fine needle aspiration of the thyroid gland. Laryngoscope 116(1), 154–156 (2006)CrossRef
17.
go back to reference T. Hor, S.W. Lahiri, Bilateral thyroid hematomas after fine-needle aspiration causing acute airway obstruction. Thyroid 18(5), 567–569 (2008)CrossRef T. Hor, S.W. Lahiri, Bilateral thyroid hematomas after fine-needle aspiration causing acute airway obstruction. Thyroid 18(5), 567–569 (2008)CrossRef
18.
go back to reference E.K. Kim, C.S. Park, W.Y. Chung, K.K. Oh, D.I. Kim, J.T. Lee, H.S. Yoo, New sonographic criteria for recommending fine-needle aspiration biopsy of nonpalpable solid nodules of the thyroid. Am. J. Roentgenol. 178(3), 687–691 (2002)CrossRef E.K. Kim, C.S. Park, W.Y. Chung, K.K. Oh, D.I. Kim, J.T. Lee, H.S. Yoo, New sonographic criteria for recommending fine-needle aspiration biopsy of nonpalpable solid nodules of the thyroid. Am. J. Roentgenol. 178(3), 687–691 (2002)CrossRef
19.
go back to reference D.G. Na, J.-h Kim, J.Y. Sung, J.H. Baek, K.C. Jung, H. Lee, H. Yoo, Core-needle biopsy is more useful than repeat fine-needle aspiration in thyroid nodules read as nondiagnostic or atypia of undetermined significance by the Bethesda system for reporting thyroid cytopathology. Thyroid 22(5), 468–475 (2012)CrossRef D.G. Na, J.-h Kim, J.Y. Sung, J.H. Baek, K.C. Jung, H. Lee, H. Yoo, Core-needle biopsy is more useful than repeat fine-needle aspiration in thyroid nodules read as nondiagnostic or atypia of undetermined significance by the Bethesda system for reporting thyroid cytopathology. Thyroid 22(5), 468–475 (2012)CrossRef
20.
go back to reference J.S. Pyo, J.H. Sohn, G. Kang, Core needle biopsy is a more conclusive follow-up method than repeat fine needle aspiration for thyroid nodules with initially inconclusive results: a systematic review and meta-analysis. J. Pathol. Transl. Med. 50(3), 217–224 (2016)CrossRef J.S. Pyo, J.H. Sohn, G. Kang, Core needle biopsy is a more conclusive follow-up method than repeat fine needle aspiration for thyroid nodules with initially inconclusive results: a systematic review and meta-analysis. J. Pathol. Transl. Med. 50(3), 217–224 (2016)CrossRef
21.
go back to reference J.Y. Sung, D.G. Na, K.S. Kim, H. Yoo, H. Lee, J.H. Kim, J.H. Baek, Diagnostic accuracy of fine-needle aspiration versus core-needle biopsy for the diagnosis of thyroid malignancy in a clinical cohort. Eur. Radiol. 22(7), 1564–1572 (2012)CrossRef J.Y. Sung, D.G. Na, K.S. Kim, H. Yoo, H. Lee, J.H. Kim, J.H. Baek, Diagnostic accuracy of fine-needle aspiration versus core-needle biopsy for the diagnosis of thyroid malignancy in a clinical cohort. Eur. Radiol. 22(7), 1564–1572 (2012)CrossRef
22.
go back to reference B. Al Knawy, M. Shiffman, Percutaneous liver biopsy in clinical practice. Liver Int. 27(9), 1166–1173 (2007)CrossRef B. Al Knawy, M. Shiffman, Percutaneous liver biopsy in clinical practice. Liver Int. 27(9), 1166–1173 (2007)CrossRef
23.
go back to reference G. Mitsuyoshi, N. Naito, A. Kawai, T. Kunisada, A. Yoshida, H. Yanai, S. Dendo, T. Yoshino, S. Kanazawa, T. Ozaki, Accurate diagnosis of musculoskeletal lesions by core needle biopsy. J. Surg. Oncol. 94(1), 21–27 (2006)CrossRef G. Mitsuyoshi, N. Naito, A. Kawai, T. Kunisada, A. Yoshida, H. Yanai, S. Dendo, T. Yoshino, S. Kanazawa, T. Ozaki, Accurate diagnosis of musculoskeletal lesions by core needle biopsy. J. Surg. Oncol. 94(1), 21–27 (2006)CrossRef
24.
go back to reference W. Bruening, J. Fontanarosa, K. Tipton, J.R. Treadwell, J. Launders, K. Schoelles, Systematic review: comparative effectiveness of core-needle and open surgical biopsy to diagnose breast lesions. Ann. Intern. Med. 152(4), 238–246 (2010)CrossRef W. Bruening, J. Fontanarosa, K. Tipton, J.R. Treadwell, J. Launders, K. Schoelles, Systematic review: comparative effectiveness of core-needle and open surgical biopsy to diagnose breast lesions. Ann. Intern. Med. 152(4), 238–246 (2010)CrossRef
25.
go back to reference S.Y. Kim, H.S. Lee, J. Moon, E.K. Kim, H.J. Moon, J.H. Yoon, J.Y. Kwak, Fine-needle aspiration versus core needle biopsy for diagnosis of thyroid malignancy and neoplasm: a matched cohort study. Eur. Radiol. 27(2), 801–811 (2017)CrossRef S.Y. Kim, H.S. Lee, J. Moon, E.K. Kim, H.J. Moon, J.H. Yoon, J.Y. Kwak, Fine-needle aspiration versus core needle biopsy for diagnosis of thyroid malignancy and neoplasm: a matched cohort study. Eur. Radiol. 27(2), 801–811 (2017)CrossRef
26.
go back to reference N. Nasrollah, P. Trimboli, F. Rossi, S. Amendola, L. Guidobaldi, C. Ventura, R. Maglio, G. Nigri, F. Romanelli, S. Valabrega, Patient’s comfort with and tolerability of thyroid core needle biopsy. Endocrine 45(1), 79–83 (2014)CrossRef N. Nasrollah, P. Trimboli, F. Rossi, S. Amendola, L. Guidobaldi, C. Ventura, R. Maglio, G. Nigri, F. Romanelli, S. Valabrega, Patient’s comfort with and tolerability of thyroid core needle biopsy. Endocrine 45(1), 79–83 (2014)CrossRef
27.
go back to reference P. Trimboli, A. Crescenzi, Thyroid core needle biopsy: taking stock of the situation. Endocrine 48(3), 779–785 (2015)CrossRef P. Trimboli, A. Crescenzi, Thyroid core needle biopsy: taking stock of the situation. Endocrine 48(3), 779–785 (2015)CrossRef
28.
go back to reference A. Carpi, G. Rossi, A. Nicolini, G. Iervasi, M. Russo, J. Mechanick, Does large needle aspiration biopsy add pain to the thyroid nodule evaluation? PLoS One 8(3), e58016 (2013)CrossRef A. Carpi, G. Rossi, A. Nicolini, G. Iervasi, M. Russo, J. Mechanick, Does large needle aspiration biopsy add pain to the thyroid nodule evaluation? PLoS One 8(3), e58016 (2013)CrossRef
Metadata
Title
Ultrasound-guided fine needle aspiration versus core needle biopsy: comparison of post-biopsy hematoma rates and risk factors
Authors
In Hye Chae
Eun-Kyung Kim
Hee Jung Moon
Jung Hyun Yoon
Vivian Y. Park
Jin Young Kwak
Publication date
01-07-2017
Publisher
Springer US
Published in
Endocrine / Issue 1/2017
Print ISSN: 1355-008X
Electronic ISSN: 1559-0100
DOI
https://doi.org/10.1007/s12020-017-1319-0

Other articles of this Issue 1/2017

Endocrine 1/2017 Go to the issue