Abstract

Background

Patient-specific gait and surgical variables are known to play an important role in wear of total hip replacements (THR). However a rigorous model, capable of predicting wear rate based on a comprehensive set of subject-specific gait and component-positioning variables, has to our knowledge, not been reported.

Questions/purpose

(1) Are there any differences between patients with high, moderate, and low wear rate in terms of gait and/or positioning variables? (2) Can we design a model to predict the wear rate based on gait and positioning variables? (3) Which group of wear factors (gait or positioning) contributes more to the wear rate?

Patients and Methods

Data on patients undergoing primary unilateral THR who performed a postoperative gait test were screened for inclusion. We included patients with a 28-mm metal head and a hip cup made of noncrosslinked polyethylene (GUR 415 and 1050) from a single manufacturer (Zimmer, Inc). To calculate wear rates from radiographs, inclusion called for patients with a series of standing radiographs taken more than 1 year after surgery. Further, exclusion criteria were established to obtain reasonably reliable and homogeneous wear readings. Seventy-three (83% of included) patients met all criteria, and the final dataset consisted of 43 males and 30 females, 69 ± 10 years old, with a BMI of 27.3 ± 4.7 kg/m2. Wear rates of these patients were determined based on the relative displacement of the femoral head with regard to the cup using a validated computer-assisted X-ray wear-analysis suite. Three groups with low (< 0.1 mm/year), moderate (0.1 to 0.2 mm/year), and high (> 0.2 mm/year) wear were established. Wear prediction followed a two-step process: (1) linear discriminant analysis to estimate the level of wear (low, moderate, or high), and (2) multiple linear and nonlinear regression modeling to predict the exact wear rate from gait and implant-positioning variables for each level of wear.

Results

There were no group differences for positioning and gait suggesting that wear differences are caused by a combination of wear factors rather than single variables. The linear discriminant analysis model correctly predicted the level of wear in 80% of patients with low wear, 87% of subjects with moderate wear, and 73% of subjects with high wear based on a combination of gait and positioning variables. For every wear level, multiple linear and nonlinear regression showed strong associations between gait biomechanics, implant positioning, and wear rate, with the nonlinear model having a higher prediction accuracy. Flexion-extension ROM and hip moments in the sagittal and transverse planes explained 42% to 60% of wear rate while positioning factors, (such as cup medialization and cup inclination angle) explained only 10% to 33%.

Conclusion

Patient-specific wear rates are associated with patients’ gait patterns. Gait pattern has a greater influence on wear than component positioning for traditional metal-on-polyethylene bearings.

Clinical Relevance

The consideration of individual gait bears potential to further reduce implant wear in THR. In the future, a predictive wear model may identify individual, modifiable wear factors for modern materials.
Literature
1.
go back to reference Affatato S. The history of biomaterials used in total hip arthroplasty (THA). Perspectives in Total Hip Arthroplasty: Advances in Biomaterials and their Tribological interactions. Sawston, UK: Woodhead Publishing; 2014:19–36. Affatato S. The history of biomaterials used in total hip arthroplasty (THA). Perspectives in Total Hip Arthroplasty: Advances in Biomaterials and their Tribological interactions. Sawston, UK: Woodhead Publishing; 2014:19–36.
2.
go back to reference Alvarez-Vera M, Contreras-Hernandez GR, Affatato S, Hernandez-Rodriguez MA. A novel total hip resurfacing design with improved range of motion and edge-load contact stress. Materials Design. 2014;55:690–698.CrossRef Alvarez-Vera M, Contreras-Hernandez GR, Affatato S, Hernandez-Rodriguez MA. A novel total hip resurfacing design with improved range of motion and edge-load contact stress. Materials Design. 2014;55:690–698.CrossRef
3.
go back to reference Andriacchi TP, Strickland AB. Gait analysis as a tool to assess joint kinetics. In Berme N, ed. Biomechanics of Normal and Pathological Human Articulating Joints. Dordrecht, Netherlands: Springer Netherlands. 1985:83–102. Andriacchi TP, Strickland AB. Gait analysis as a tool to assess joint kinetics. In Berme N, ed. Biomechanics of Normal and Pathological Human Articulating Joints. Dordrecht, Netherlands: Springer Netherlands. 1985:83–102.
4.
go back to reference Ardestani MM, Chen Z, Wang L, Lian Q, Liu Y, He J, Li D, Jin Z. A neural network approach for determining gait modifications to reduce the contact force in knee joint implant. Med Eng Phys. 2014;36:1253–1265.CrossRefPubMed Ardestani MM, Chen Z, Wang L, Lian Q, Liu Y, He J, Li D, Jin Z. A neural network approach for determining gait modifications to reduce the contact force in knee joint implant. Med Eng Phys. 2014;36:1253–1265.CrossRefPubMed
5.
go back to reference Ardestani MM, Moazen M, Chen Z, Zhang J, Jin Z. A real-time topography of maximum contact pressure distribution at medial tibiofemoral knee implant during gait: application to knee rehabilitation. Neurocomputing. 2015;154:174–188.CrossRef Ardestani MM, Moazen M, Chen Z, Zhang J, Jin Z. A real-time topography of maximum contact pressure distribution at medial tibiofemoral knee implant during gait: application to knee rehabilitation. Neurocomputing. 2015;154:174–188.CrossRef
6.
go back to reference Ardestani MM, Moazen M, Jin Z. Gait modification and optimization using neural network–genetic algorithm approach: application to knee rehabilitation. Expert Systems Applications. 2014;41:7466–7477.CrossRef Ardestani MM, Moazen M, Jin Z. Gait modification and optimization using neural network–genetic algorithm approach: application to knee rehabilitation. Expert Systems Applications. 2014;41:7466–7477.CrossRef
7.
go back to reference Ardestani MM, Zhang X, Wang L, Lian Q, Liu Y, He J, Li D, Jin Z. Human lower extremity joint moment prediction: a wavelet neural network approach. Expert Systems Applications. 2014;41:4422–4433.CrossRef Ardestani MM, Zhang X, Wang L, Lian Q, Liu Y, He J, Li D, Jin Z. Human lower extremity joint moment prediction: a wavelet neural network approach. Expert Systems Applications. 2014;41:4422–4433.CrossRef
8.
go back to reference Austin PC, Steyerberg EW. The number of subjects per variable required in linear regression analyses. J Clin Epidemiol. 2015;68:627–636.CrossRefPubMed Austin PC, Steyerberg EW. The number of subjects per variable required in linear regression analyses. J Clin Epidemiol. 2015;68:627–636.CrossRefPubMed
10.
go back to reference Bennett D, Humphreys L, O’Brien S, Kelly C, Orr JF, Beverland DE. Wear paths produced by individual hip-replacement patients: a large-scale, long-term follow-up study. J Biomech. 2008;41:2474–2482.CrossRefPubMed Bennett D, Humphreys L, O’Brien S, Kelly C, Orr JF, Beverland DE. Wear paths produced by individual hip-replacement patients: a large-scale, long-term follow-up study. J Biomech. 2008;41:2474–2482.CrossRefPubMed
11.
go back to reference Berzins A, Sumner DR, Galante JO. Dimensional characteristics of uncomplicated autopsy-retrieved acetabular polyethylene liners by ultrasound. J Biomed Mater Res.1998;39:120–129.CrossRefPubMed Berzins A, Sumner DR, Galante JO. Dimensional characteristics of uncomplicated autopsy-retrieved acetabular polyethylene liners by ultrasound. J Biomed Mater Res.1998;39:120–129.CrossRefPubMed
12.
go back to reference Charnley J. Low friction principle. Low Friction Arthroplasty of the Hip. New York, NY: Springer-Verlag; 1979:3-15. Charnley J. Low friction principle. Low Friction Arthroplasty of the Hip. New York, NY: Springer-Verlag; 1979:3-15.
13.
go back to reference Clarke IC, Gustafson A, Jung H, Fujisawa A. Hip-simulator ranking of polyethylene wear: comparisons between ceramic heads of different sizes. Acta Orthop Scand. 1996;67:128–132.CrossRefPubMed Clarke IC, Gustafson A, Jung H, Fujisawa A. Hip-simulator ranking of polyethylene wear: comparisons between ceramic heads of different sizes. Acta Orthop Scand. 1996;67:128–132.CrossRefPubMed
14.
go back to reference Davey SM, Orr JF, Buchanan FJ, Nixon JR, Bennett D. The effect of patient gait on the material properties of UHMWPE in hip replacements. Biomaterials. 2005;26:4993–5001.CrossRefPubMed Davey SM, Orr JF, Buchanan FJ, Nixon JR, Bennett D. The effect of patient gait on the material properties of UHMWPE in hip replacements. Biomaterials. 2005;26:4993–5001.CrossRefPubMed
15.
go back to reference Delaunay C, Hamadouche M, Girard J, Duhamel A; SoFCOT Group. What are the causes for failures of primary hip arthroplasties in France? Clin Orthop Relat Res. 2013;471:3863–3869.CrossRefPubMedPubMedCentral Delaunay C, Hamadouche M, Girard J, Duhamel A; SoFCOT Group. What are the causes for failures of primary hip arthroplasties in France? Clin Orthop Relat Res. 2013;471:3863–3869.CrossRefPubMedPubMedCentral
16.
go back to reference Domb BG, El Bitar YF, Sadik AY, Stake CE, Botser IB. Comparison of robotic-assisted and conventional acetabular cup placement in THA: a matched-pair controlled study. Clin Orthop Relat Res. 2013;472:329–336.CrossRefPubMedPubMedCentral Domb BG, El Bitar YF, Sadik AY, Stake CE, Botser IB. Comparison of robotic-assisted and conventional acetabular cup placement in THA: a matched-pair controlled study. Clin Orthop Relat Res. 2013;472:329–336.CrossRefPubMedPubMedCentral
17.
go back to reference Donaldson FE, Nyman E Jr, Coburn JC. Prediction of contact mechanics in metal-on-metal total hip replacement for parametrically comprehensive designs and loads. J Biomech. 2015;48:1828–1835.CrossRefPubMed Donaldson FE, Nyman E Jr, Coburn JC. Prediction of contact mechanics in metal-on-metal total hip replacement for parametrically comprehensive designs and loads. J Biomech. 2015;48:1828–1835.CrossRefPubMed
18.
go back to reference Elkins JM, Callaghan JJ, Brown TD. Stability and trunnion wear potential in large-diameter metal-on-metal total hips: a finite element analysis. Clin Orthop Relat Res. 2014;472:529–542.CrossRefPubMed Elkins JM, Callaghan JJ, Brown TD. Stability and trunnion wear potential in large-diameter metal-on-metal total hips: a finite element analysis. Clin Orthop Relat Res. 2014;472:529–542.CrossRefPubMed
19.
go back to reference Elkins JM, Callaghan JJ, Brown TD. The 2014 Frank Stinchfield Award: The “landing zone” for wear and stability in total hip arthroplasty is smaller than we thought: a computational analysis. Clin Orthop Relat Res. 2015;473:441–452.CrossRefPubMed Elkins JM, Callaghan JJ, Brown TD. The 2014 Frank Stinchfield Award: The “landing zone” for wear and stability in total hip arthroplasty is smaller than we thought: a computational analysis. Clin Orthop Relat Res. 2015;473:441–452.CrossRefPubMed
20.
go back to reference Foucher KC, Hurwitz DE, Wimmer MA. Do gait adaptations during stair climbing result in changes in implant forces in subjects with total hip replacements compared to normal subjects? Clin Biomech (Bristol, Avon). 2008;23:754–761.CrossRef Foucher KC, Hurwitz DE, Wimmer MA. Do gait adaptations during stair climbing result in changes in implant forces in subjects with total hip replacements compared to normal subjects? Clin Biomech (Bristol, Avon). 2008;23:754–761.CrossRef
21.
go back to reference Foucher KC, Hurwitz DE, Wimmer MA. Relative importance of gait vs. joint positioning on hip contact forces after total hip replacement. J Orthop Res. 2009;27:1576–1582.CrossRefPubMed Foucher KC, Hurwitz DE, Wimmer MA. Relative importance of gait vs. joint positioning on hip contact forces after total hip replacement. J Orthop Res. 2009;27:1576–1582.CrossRefPubMed
22.
go back to reference Garvin KL, Hartman CW, Mangla J, Murdoch N, Martell JM. Wear analysis in THA utilizing oxidized zirconium and crosslinked polyethylene. Clin Orthop Relat Res. 2009;467:141–145.CrossRefPubMed Garvin KL, Hartman CW, Mangla J, Murdoch N, Martell JM. Wear analysis in THA utilizing oxidized zirconium and crosslinked polyethylene. Clin Orthop Relat Res. 2009;467:141–145.CrossRefPubMed
23.
go back to reference Hamilton WG, Hopper RH, Ginn SD, Hammell NP, Engh CA Jr, Engh CA. The effect of total hip arthroplasty cup design on polyethylene wear rate. J Arthroplasty. 2005;20(7 suppl 3):63–72.CrossRefPubMed Hamilton WG, Hopper RH, Ginn SD, Hammell NP, Engh CA Jr, Engh CA. The effect of total hip arthroplasty cup design on polyethylene wear rate. J Arthroplasty. 2005;20(7 suppl 3):63–72.CrossRefPubMed
24.
go back to reference Iyer MS, Rhinehart RR. A method to determine the required number of neural-network training repetitions. IEEE Trans Neural Netw. 1999;10:427–432.CrossRefPubMed Iyer MS, Rhinehart RR. A method to determine the required number of neural-network training repetitions. IEEE Trans Neural Netw. 1999;10:427–432.CrossRefPubMed
25.
go back to reference Imbuldeniya AM, Walter WL, Zicat BA, Walter WK. Cementless total hip replacement without femoral osteotomy in patients with severe developmental dysplasia of the hip: minimum 15-year clinical and radiological results. Bone Joint J. 2014;96:1449–1454.CrossRefPubMed Imbuldeniya AM, Walter WL, Zicat BA, Walter WK. Cementless total hip replacement without femoral osteotomy in patients with severe developmental dysplasia of the hip: minimum 15-year clinical and radiological results. Bone Joint J. 2014;96:1449–1454.CrossRefPubMed
26.
go back to reference Kirkwood RN, Culham EG, Costigan P. Radiographic and non-invasive determination of the hip joint center location: effect on hip joint moments. Clin Biomech (Bristol, Avon). 1999;14:227–235.CrossRef Kirkwood RN, Culham EG, Costigan P. Radiographic and non-invasive determination of the hip joint center location: effect on hip joint moments. Clin Biomech (Bristol, Avon). 1999;14:227–235.CrossRef
27.
go back to reference Korduba LA, Essner A, Pivec R, Lancin P, Mont MA, Wang A, Delanois RE. Effect of acetabular cup abduction angle on wear of ultrahigh-molecular-weight polyethylene in hip simulator testing. Am J Orthop (Belle Mead NJ). 2014; 43:466–471.PubMed Korduba LA, Essner A, Pivec R, Lancin P, Mont MA, Wang A, Delanois RE. Effect of acetabular cup abduction angle on wear of ultrahigh-molecular-weight polyethylene in hip simulator testing. Am J Orthop (Belle Mead NJ). 2014; 43:466–471.PubMed
28.
go back to reference Kurtz SM, Ong KL. Contemporary total hip arthroplasty: alternative bearings. UHMWPE Biomaterials Handbook: Ultra High Molecular Weight Polyethylene in Total Joint Replacement and Medical Devices. 3rd ed. Oxford, UK: William Andrew Publishing/Elsevier; 2016:72–105. Kurtz SM, Ong KL. Contemporary total hip arthroplasty: alternative bearings. UHMWPE Biomaterials Handbook: Ultra High Molecular Weight Polyethylene in Total Joint Replacement and Medical Devices. 3rd ed. Oxford, UK: William Andrew Publishing/Elsevier; 2016:72–105.
29.
go back to reference Kurtz SM, Ong KL, Lau E, Bozic KJ. Impact of the economic downturn on total joint replacement demand in the United States: updaedf projections to 2021. J Bone Joint Surg Am. 2014;96:624–630.CrossRefPubMed Kurtz SM, Ong KL, Lau E, Bozic KJ. Impact of the economic downturn on total joint replacement demand in the United States: updaedf projections to 2021. J Bone Joint Surg Am. 2014;96:624–630.CrossRefPubMed
30.
go back to reference Leslie IJ, Williams S, Isaac G, Ingham E, Fisher J. High cup angle and microseparation increase the wear of hip surface replacements. Clin Orthop Relat Res. 2009;467:2259–2265.CrossRefPubMedPubMedCentral Leslie IJ, Williams S, Isaac G, Ingham E, Fisher J. High cup angle and microseparation increase the wear of hip surface replacements. Clin Orthop Relat Res. 2009;467:2259–2265.CrossRefPubMedPubMedCentral
31.
go back to reference Liao Y, Hoffman E, Wimmer M, Fischer A, Jacobs J, Marks L. CoCrMo metal-on-metal hip replacements. Phys Chem Chem Phys. 2013;15:746–756.CrossRefPubMed Liao Y, Hoffman E, Wimmer M, Fischer A, Jacobs J, Marks L. CoCrMo metal-on-metal hip replacements. Phys Chem Chem Phys. 2013;15:746–756.CrossRefPubMed
32.
go back to reference Lundberg HJ, Stewart KJ, Pedersen DR, Callaghan JJ, Brown TD. Nonidentical and outlier duty cycles as factors accelerating UHMWPE wear in THA: a finite element exploration. J Orthop Res. 2007;25:30–43.CrossRefPubMed Lundberg HJ, Stewart KJ, Pedersen DR, Callaghan JJ, Brown TD. Nonidentical and outlier duty cycles as factors accelerating UHMWPE wear in THA: a finite element exploration. J Orthop Res. 2007;25:30–43.CrossRefPubMed
33.
go back to reference Martell JM, Berdia S. Determination of polyethylene wear in total hip replacements with use of digital radiographs. J Bone Joint Surg Am. 1997;79:1635–1641.CrossRefPubMed Martell JM, Berdia S. Determination of polyethylene wear in total hip replacements with use of digital radiographs. J Bone Joint Surg Am. 1997;79:1635–1641.CrossRefPubMed
34.
go back to reference Matsoukas G, Kim IY. Design optimization of a total hip prosthesis for wear reduction. J Biomech Eng. 2009;131:051003.CrossRefPubMed Matsoukas G, Kim IY. Design optimization of a total hip prosthesis for wear reduction. J Biomech Eng. 2009;131:051003.CrossRefPubMed
35.
go back to reference McLachlan GJ. Discriminant Analysis and Statistical Pattern Recognition. New York, NY: Wiley, John & Sons; 2004. McLachlan GJ. Discriminant Analysis and Statistical Pattern Recognition. New York, NY: Wiley, John & Sons; 2004.
36.
go back to reference Mihalko WM, Wimmer MA, Pacione CA, Laurent MP, Murphy RF, Rider C. How have alternative bearings and modularity affected revision rates in total hip arthroplasty? Clin Orthop Relat Res. 2014;472:3747–3758.CrossRefPubMedPubMedCentral Mihalko WM, Wimmer MA, Pacione CA, Laurent MP, Murphy RF, Rider C. How have alternative bearings and modularity affected revision rates in total hip arthroplasty? Clin Orthop Relat Res. 2014;472:3747–3758.CrossRefPubMedPubMedCentral
37.
go back to reference Naal FD, Impellizzeri FM. How active are patients undergoing total joint arthroplasty? A systematic review. Clin Orthop Relat Res. 2009;468:1891–1904.CrossRefPubMedPubMedCentral Naal FD, Impellizzeri FM. How active are patients undergoing total joint arthroplasty? A systematic review. Clin Orthop Relat Res. 2009;468:1891–1904.CrossRefPubMedPubMedCentral
38.
go back to reference Orozco Villaseñor DA, Wimmer MA. Wear scar similarities between retrieved and simulator-tested polyethylene TKR components: an artificial neural network approach. Biomed Res Int. 2016;2016:2071945.CrossRefPubMedPubMedCentral Orozco Villaseñor DA, Wimmer MA. Wear scar similarities between retrieved and simulator-tested polyethylene TKR components: an artificial neural network approach. Biomed Res Int. 2016;2016:2071945.CrossRefPubMedPubMedCentral
39.
go back to reference Perrin T, Dorr LD, Perry J, Gronley J, Hull DB. Functional evaluation of total hip arthroplasty with five-to ten-year follow-up evaluation. Clin Orthop Relat Res. 1985;195:252-260. Perrin T, Dorr LD, Perry J, Gronley J, Hull DB. Functional evaluation of total hip arthroplasty with five-to ten-year follow-up evaluation. Clin Orthop Relat Res. 1985;195:252-260.
40.
go back to reference Picard RR, Cook RD. Cross-validation of regression models. J Am Stat Assoc. 1984;79:575-583.CrossRef Picard RR, Cook RD. Cross-validation of regression models. J Am Stat Assoc. 1984;79:575-583.CrossRef
41.
go back to reference Pierannunzii L, Fischer F, d’Imporzano M. Retroacetabular osteolytic lesions behind well-fixed prosthetic cups: pilot study of bearings-retaining surgery. J Orthop Traumatol. 2008;9:225–231.CrossRefPubMedPubMedCentral Pierannunzii L, Fischer F, d’Imporzano M. Retroacetabular osteolytic lesions behind well-fixed prosthetic cups: pilot study of bearings-retaining surgery. J Orthop Traumatol. 2008;9:225–231.CrossRefPubMedPubMedCentral
42.
go back to reference Scheerlinck T. Cup positioning in total hip arthroplasty. Acta Orthop Belg. 2014;80:336–347.PubMed Scheerlinck T. Cup positioning in total hip arthroplasty. Acta Orthop Belg. 2014;80:336–347.PubMed
43.
go back to reference Schmalzried TP, Shepherd EF, Dorey FJ, Jackson WO, dela Rosa M, Fa’vae F, McKellop HA, McClung CD, Martell J, Moreland JR, Amstutz HC. The John Charnley Award: Wear is a function of use, not time. Clin Orthop Relat Res. 2000;381:36–46.CrossRef Schmalzried TP, Shepherd EF, Dorey FJ, Jackson WO, dela Rosa M, Fa’vae F, McKellop HA, McClung CD, Martell J, Moreland JR, Amstutz HC. The John Charnley Award: Wear is a function of use, not time. Clin Orthop Relat Res. 2000;381:36–46.CrossRef
44.
go back to reference Wong C, Stilling M. Polyethylene wear in total hip arthroplasty for suboptimal acetabular cup positions and for different polyethylene types: experimental evaluation of wear simulation by finite element analysis using clinical radiostereometric measurements. In Knahr K, ed. Tribology in Total Hip Arthroplasty. Berlin, Germany: Springer; 2011:135–158.CrossRef Wong C, Stilling M. Polyethylene wear in total hip arthroplasty for suboptimal acetabular cup positions and for different polyethylene types: experimental evaluation of wear simulation by finite element analysis using clinical radiostereometric measurements. In Knahr K, ed. Tribology in Total Hip Arthroplasty. Berlin, Germany: Springer; 2011:135–158.CrossRef
Metadata
Title
Prediction of Polyethylene Wear Rates from Gait Biomechanics and Implant Positioning in Total Hip Replacement
Authors
Marzieh M. Ardestani, PhD
Pedro P. Amenábar Edwards, MD
Markus A. Wimmer, PhD
Publication date
01-08-2017
Publisher
Springer US
Published in
Clinical Orthopaedics and Related Research® / Issue 8/2017
Print ISSN: 0009-921X
Electronic ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-017-5293-x

Other articles of this Issue 8/2017

Clinical Orthopaedics and Related Research® 8/2017 Go to the issue