Abstract

Background

During the mid-1990s when our institution was using a press-fit porous-coated cup without supplemental initial fixation for primary THA, the manufacturer transitioned from gamma irradiation to gas plasma for the terminal sterilization of their polyethylene liners.

Questions/purposes

At minimum 10-year followup, we asked whether the fixation achieved by solely relying on a press-fit would be durable and how different liner sterilization methods affected radiographic wear, osteolysis, and survivorship.

Patients and Methods

We retrospectively reviewed 373 patients who underwent 398 primary THAs with a press-fit porous-coated cup between March 1995 and December 1996. Mean age at time of surgery was 61.5 ± 13.3 years and mean followup was 10.4 ± 3.7 years. We determined reasons for revision, survivorship, femoral head penetration, osteolysis, and wear-related complications.

Results

Among 20 revisions involving any component, seven were associated with wear and osteolysis. Kaplan-Meier survivorship, using component revision for any reason as an end point, was 95.7% (95% confidence interval, 93.6%–97.9%) at 10 years. Noncrosslinked liners sterilized with gas plasma demonstrated a mean head penetration rate of 0.20 ± 0.09 mm/year compared with 0.13 ± 0.07 mm/year for liners sterilized with gamma irradiation in air and 0.09 ± 0.04 mm/year for liners sterilized with gamma-irradiation with barrier packaging without oxygen. THAs with increased volumetric wear tended to demonstrate larger osteolytic lesions (r = 0.40) and there tended to be less osteolysis among the liners sterilized with gamma-irradiation with barrier packaging without oxygen. However, there was no difference in survivorship among the sterilization groups and there has been no cup or stem loosening associated with osteolysis.

Conclusions

Durable biologic fixation through 10-year followup can be achieved by solely relying on an initial press-fit. Noncrosslinking gas plasma for terminal sterilization of the polyethylene liners was associated with greater head penetration rate than gamma irradiation.

Level of Evidence

Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
Literature
1.
go back to reference Barrack RL, Butler RA. Avoidance and management of neurovascular injuries in total hip arthroplasty. Instr Course Lect. 2003;52:267–274.PubMed Barrack RL, Butler RA. Avoidance and management of neurovascular injuries in total hip arthroplasty. Instr Course Lect. 2003;52:267–274.PubMed
2.
go back to reference Chen CJ, Xenos JS, McAuley JP, Young A, Engh CA Sr. Second-generation porous-coated cementless total hip arthroplasties have high survival. Clin Orthop Relat Res. 2006;451:121–127.PubMedCrossRef Chen CJ, Xenos JS, McAuley JP, Young A, Engh CA Sr. Second-generation porous-coated cementless total hip arthroplasties have high survival. Clin Orthop Relat Res. 2006;451:121–127.PubMedCrossRef
3.
go back to reference Claus AM, Hopper RH Jr, Engh CA. Fractures of the greater trochanter induced by osteolysis with the anatomic medullary locking prosthesis. J Arthroplasty. 2002;17:706–712.PubMedCrossRef Claus AM, Hopper RH Jr, Engh CA. Fractures of the greater trochanter induced by osteolysis with the anatomic medullary locking prosthesis. J Arthroplasty. 2002;17:706–712.PubMedCrossRef
4.
go back to reference Claus AM, Sychterz CJ, Hopper RH Jr, Engh CA. Pattern of osteolysis around two different cementless metal-backed cups: retrospective, radiographic analysis at minimum 10-year follow-up. J Arthroplasty. 2001;16(8 Suppl 1):177–182.PubMedCrossRef Claus AM, Sychterz CJ, Hopper RH Jr, Engh CA. Pattern of osteolysis around two different cementless metal-backed cups: retrospective, radiographic analysis at minimum 10-year follow-up. J Arthroplasty. 2001;16(8 Suppl 1):177–182.PubMedCrossRef
5.
go back to reference Costa L, Bracco P, Brach del Prever EM, Kurtz SM, Gallinaro P. Oxidation and oxidation potential in contemporary packaging for polyethylene total joint replacement components. J Biomed Mater Res B Appl Biomater. 2006;78:20–26.PubMed Costa L, Bracco P, Brach del Prever EM, Kurtz SM, Gallinaro P. Oxidation and oxidation potential in contemporary packaging for polyethylene total joint replacement components. J Biomed Mater Res B Appl Biomater. 2006;78:20–26.PubMed
6.
go back to reference DeLee JG, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res. 1976;121:20–32.PubMed DeLee JG, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res. 1976;121:20–32.PubMed
7.
go back to reference Digas G, Thanner J, Nivbrant B, Röhrl S, Ström H, Kärrholm J. Increase in early polyethylene wear after sterilization with ethylene oxide: radiostereometric analyses of 201 total hips. Acta Orthop Scand. 2003;74:531–541.PubMedCrossRef Digas G, Thanner J, Nivbrant B, Röhrl S, Ström H, Kärrholm J. Increase in early polyethylene wear after sterilization with ethylene oxide: radiostereometric analyses of 201 total hips. Acta Orthop Scand. 2003;74:531–541.PubMedCrossRef
8.
go back to reference Egawa H, Ho H, Hopper RH Jr, Engh CA Jr, Engh CA. Computed tomography assessment of pelvic osteolysis and cup-lesion interface involvement with a press-fit porous-coated acetabular cup. J Arthroplasty. 2009;24:233–239.PubMedCrossRef Egawa H, Ho H, Hopper RH Jr, Engh CA Jr, Engh CA. Computed tomography assessment of pelvic osteolysis and cup-lesion interface involvement with a press-fit porous-coated acetabular cup. J Arthroplasty. 2009;24:233–239.PubMedCrossRef
9.
go back to reference Egawa H, Powers CC, Beykirch SE, Hopper RH Jr, Engh CA Jr, Engh CA. Can the volume of pelvic osteolysis be calculated without using computed tomography? Clin Orthop Relat Res. 2009;467:181–187.PubMedCrossRef Egawa H, Powers CC, Beykirch SE, Hopper RH Jr, Engh CA Jr, Engh CA. Can the volume of pelvic osteolysis be calculated without using computed tomography? Clin Orthop Relat Res. 2009;467:181–187.PubMedCrossRef
10.
go back to reference Emms NW, Stockley I, Hamer AJ, Wilkinson JM. Long-term outcome of a cementless, hemispherical, press-fit acetabular component: survivorship analysis and dose-response relationship to linear polyethylene wear. J Bone Joint Surg Br. 2010;92:856–861.PubMedCrossRef Emms NW, Stockley I, Hamer AJ, Wilkinson JM. Long-term outcome of a cementless, hemispherical, press-fit acetabular component: survivorship analysis and dose-response relationship to linear polyethylene wear. J Bone Joint Surg Br. 2010;92:856–861.PubMedCrossRef
11.
go back to reference Engh CA, Bobyn JD. Principles, techniques, results, and complications with a porous-coated sintered metal system. Instr Course Lect. 1986;35:169–183.PubMed Engh CA, Bobyn JD. Principles, techniques, results, and complications with a porous-coated sintered metal system. Instr Course Lect. 1986;35:169–183.PubMed
12.
go back to reference Engh CA, Bobyn JD, Glassman AH. Porous-coated hip replacement: the factors governing bone ingrowth, stress shielding, and clinical results. J Bone Joint Surg Br. 1987;69:45–55.PubMed Engh CA, Bobyn JD, Glassman AH. Porous-coated hip replacement: the factors governing bone ingrowth, stress shielding, and clinical results. J Bone Joint Surg Br. 1987;69:45–55.PubMed
13.
go back to reference Engh CA, Hopper RH Jr, Engh CA Jr. Long-term porous-coated cup survivorship using spikes, screws, and press-fitting for initial fixation. J Arthroplasty. 2004;19(7 Suppl 2):54–60.PubMedCrossRef Engh CA, Hopper RH Jr, Engh CA Jr. Long-term porous-coated cup survivorship using spikes, screws, and press-fitting for initial fixation. J Arthroplasty. 2004;19(7 Suppl 2):54–60.PubMedCrossRef
14.
go back to reference Engh CA, Massin P, Suthers KE. Roentgenographic assessment of the biologic fixation of porous-coated femoral components. Clin Orthop Relat Res. 1990;257:107–128.PubMed Engh CA, Massin P, Suthers KE. Roentgenographic assessment of the biologic fixation of porous-coated femoral components. Clin Orthop Relat Res. 1990;257:107–128.PubMed
15.
go back to reference Engh CA, O’Connor D, Jasty M, McGovern TF, Bobyn JD, Harris WH. Quantification of implant micromotion, strain shielding, and bone resorption with porous-coated anatomic medullary locking femoral prostheses. Clin Orthop Relat Res. 1992;285:13–29.PubMed Engh CA, O’Connor D, Jasty M, McGovern TF, Bobyn JD, Harris WH. Quantification of implant micromotion, strain shielding, and bone resorption with porous-coated anatomic medullary locking femoral prostheses. Clin Orthop Relat Res. 1992;285:13–29.PubMed
16.
go back to reference Engh CA Jr, Culpepper WJ 2nd, Engh CA. Long-term results of use of the anatomic medullary locking prosthesis in total hip arthroplasty. J Bone Joint Surg Am. 1997;79:177–184.PubMedCrossRef Engh CA Jr, Culpepper WJ 2nd, Engh CA. Long-term results of use of the anatomic medullary locking prosthesis in total hip arthroplasty. J Bone Joint Surg Am. 1997;79:177–184.PubMedCrossRef
17.
go back to reference Gruen TA, McNeice GM, Amstutz HC. “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res. 1979;141:17–27.PubMed Gruen TA, McNeice GM, Amstutz HC. “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res. 1979;141:17–27.PubMed
18.
go back to reference Hamilton WG, Hopper RH Jr, Ginn SD, Hammell NP, Engh CA Jr, Engh CA. The effect of total hip arthroplasty cup design on polyethylene wear rate. J Arthroplasty. 2005;20(7 Suppl 3):63–72.PubMedCrossRef Hamilton WG, Hopper RH Jr, Ginn SD, Hammell NP, Engh CA Jr, Engh CA. The effect of total hip arthroplasty cup design on polyethylene wear rate. J Arthroplasty. 2005;20(7 Suppl 3):63–72.PubMedCrossRef
19.
go back to reference Hennessy DW, Callaghan JJ, Liu SS. Second-generation extensively porous-coated THA stems at minimum 10-year followup. Clin Orthop Relat Res. 2009;467:2290–2296.PubMedCrossRef Hennessy DW, Callaghan JJ, Liu SS. Second-generation extensively porous-coated THA stems at minimum 10-year followup. Clin Orthop Relat Res. 2009;467:2290–2296.PubMedCrossRef
20.
go back to reference Hopper RH Jr, Engh CA Jr, Fowlkes LB, Engh CA. The pros and cons of polyethylene sterilization with gamma irradiation. Clin Orthop Relat Res. 2004;429:54–62.PubMedCrossRef Hopper RH Jr, Engh CA Jr, Fowlkes LB, Engh CA. The pros and cons of polyethylene sterilization with gamma irradiation. Clin Orthop Relat Res. 2004;429:54–62.PubMedCrossRef
21.
go back to reference Hopper RH Jr, Young AM, Orishimo KF, Engh CA Jr. Effect of terminal sterilization with gas plasma or gamma radiation on wear of polyethylene liners. J Bone Joint Surg Am. 2003;85:464–468.PubMed Hopper RH Jr, Young AM, Orishimo KF, Engh CA Jr. Effect of terminal sterilization with gas plasma or gamma radiation on wear of polyethylene liners. J Bone Joint Surg Am. 2003;85:464–468.PubMed
22.
go back to reference Hui AJ, McCalden RW, Martell JM, MacDonald SJ, Bourne RB, Rorabeck CH. Validation of two and three-dimensional radiographic techniques for measuring polyethylene wear after total hip arthroplasty. J Bone Joint Surg Am. 2003;85:505–511.PubMed Hui AJ, McCalden RW, Martell JM, MacDonald SJ, Bourne RB, Rorabeck CH. Validation of two and three-dimensional radiographic techniques for measuring polyethylene wear after total hip arthroplasty. J Bone Joint Surg Am. 2003;85:505–511.PubMed
23.
go back to reference Ise K, Kawanabe K, Matsusaki T, Shimizu M, Onishi E, Nakamura T. Patient sensitivity to polyethylene particles with cemented total hip arthroplasty. J Arthroplasty. 2007;22:966–973.PubMedCrossRef Ise K, Kawanabe K, Matsusaki T, Shimizu M, Onishi E, Nakamura T. Patient sensitivity to polyethylene particles with cemented total hip arthroplasty. J Arthroplasty. 2007;22:966–973.PubMedCrossRef
24.
go back to reference Jialiang T, Zhongyou M, Fuxing P, Zongke Z, Bin S, Jing Y. Primary total hip arthroplasty with Duraloc cup in patients younger than 50 years: a 5- to 7-year follow-up study. J Arthroplasty. 2009;24:1184–1187.PubMedCrossRef Jialiang T, Zhongyou M, Fuxing P, Zongke Z, Bin S, Jing Y. Primary total hip arthroplasty with Duraloc cup in patients younger than 50 years: a 5- to 7-year follow-up study. J Arthroplasty. 2009;24:1184–1187.PubMedCrossRef
25.
go back to reference Kaplan EL, Meier P. Nonparametric estimation from incomplete observations. J Am Stat Assoc. 1958;53:457–81.CrossRef Kaplan EL, Meier P. Nonparametric estimation from incomplete observations. J Am Stat Assoc. 1958;53:457–81.CrossRef
26.
go back to reference Kay RM, Dorey FJ, Johnston-Jones K, Cracchiolo A 3rd, Amstutz HC, Finerman GA. Long-term durability of cemented primary total hip arthroplasty. J Arthroplasty. 1995;10(Suppl):S29–S38.PubMedCrossRef Kay RM, Dorey FJ, Johnston-Jones K, Cracchiolo A 3rd, Amstutz HC, Finerman GA. Long-term durability of cemented primary total hip arthroplasty. J Arthroplasty. 1995;10(Suppl):S29–S38.PubMedCrossRef
27.
go back to reference Kitamura N, Leung SB, Engh CA Sr. Characteristics of pelvic osteolysis on computed tomography after total hip arthroplasty. Clin Orthop Relat Res. 2005;441:291–297.PubMedCrossRef Kitamura N, Leung SB, Engh CA Sr. Characteristics of pelvic osteolysis on computed tomography after total hip arthroplasty. Clin Orthop Relat Res. 2005;441:291–297.PubMedCrossRef
28.
go back to reference Martell JM, Berdia S. Determination of polyethylene wear in total hip replacements with use of digital radiographs. J Bone Joint Surg Am. 1997;79:1635–1641.PubMed Martell JM, Berdia S. Determination of polyethylene wear in total hip replacements with use of digital radiographs. J Bone Joint Surg Am. 1997;79:1635–1641.PubMed
29.
go back to reference Massin P, Schmidt L, Engh CA. Evaluation of cementless acetabular migration: an experimental study. J Arthroplasty. 1989;4:245–251.PubMedCrossRef Massin P, Schmidt L, Engh CA. Evaluation of cementless acetabular migration: an experimental study. J Arthroplasty. 1989;4:245–251.PubMedCrossRef
30.
go back to reference Mayne IP, Kosashvili Y, White LM, Backstein D. Iliopsoas tendonitis due to the protrusion of an acetabular component fixation screw after total hip arthroplasty. J Arthroplasty. 2010;25:659.e5–8.CrossRef Mayne IP, Kosashvili Y, White LM, Backstein D. Iliopsoas tendonitis due to the protrusion of an acetabular component fixation screw after total hip arthroplasty. J Arthroplasty. 2010;25:659.e5–8.CrossRef
31.
go back to reference McGovern TF, Ammeen DJ, Collier JP, Currier BH, Engh GA. Rapid polyethylene failure of unicondylar tibial components sterilized with gamma irradiation in air and implanted after a long shelf life. J Bone Joint Surg Am. 2002;84:901–906.PubMed McGovern TF, Ammeen DJ, Collier JP, Currier BH, Engh GA. Rapid polyethylene failure of unicondylar tibial components sterilized with gamma irradiation in air and implanted after a long shelf life. J Bone Joint Surg Am. 2002;84:901–906.PubMed
32.
go back to reference McKellop H, Shen FW, Lu B, Campbell P, Salovey R. Effect of sterilization method and other modifications on the wear resistance of acetabular cups made of ultra-high molecular weight polyethylene: a hip-simulator study. J Bone Joint Surg Am. 2000;82:1708–1725.PubMed McKellop H, Shen FW, Lu B, Campbell P, Salovey R. Effect of sterilization method and other modifications on the wear resistance of acetabular cups made of ultra-high molecular weight polyethylene: a hip-simulator study. J Bone Joint Surg Am. 2000;82:1708–1725.PubMed
33.
go back to reference Medel FJ, Kurtz SM, Hozack WJ, Parvizi J, Purtill JJ, Sharkey PF, MacDonald D, Kraay MJ, Goldberg V, Rimnac CM. Gamma inert sterilization: a solution to polyethylene oxidation? J Bone Joint Surg Am. 2009;91:839–849.PubMedCrossRef Medel FJ, Kurtz SM, Hozack WJ, Parvizi J, Purtill JJ, Sharkey PF, MacDonald D, Kraay MJ, Goldberg V, Rimnac CM. Gamma inert sterilization: a solution to polyethylene oxidation? J Bone Joint Surg Am. 2009;91:839–849.PubMedCrossRef
34.
go back to reference Muratoglu OK, Merrill EW, Bragdon CR, O’Connor D, Hoeffel D, Burroughs B, Jasty M, Harris WH. Effect of radiation, heat, and aging on in vitro wear resistance of polyethylene. Clin Orthop Relat Res. 2003;417:253–262.PubMed Muratoglu OK, Merrill EW, Bragdon CR, O’Connor D, Hoeffel D, Burroughs B, Jasty M, Harris WH. Effect of radiation, heat, and aging on in vitro wear resistance of polyethylene. Clin Orthop Relat Res. 2003;417:253–262.PubMed
35.
go back to reference Puri L, Wixson RL, Stern SH, Kohli J, Hendrix RW, Stulberg SD. Use of helical computed tomography for the assessment of acetabular osteolysis after total hip arthroplasty. J Bone Joint Surg Am. 2002;84:609–614.PubMed Puri L, Wixson RL, Stern SH, Kohli J, Hendrix RW, Stulberg SD. Use of helical computed tomography for the assessment of acetabular osteolysis after total hip arthroplasty. J Bone Joint Surg Am. 2002;84:609–614.PubMed
36.
go back to reference Roth A, Winzer T, Sander K, Anders JO, Venbrocks RA. Press fit fixation of cementless cups: how much stability do we need indeed? Arch Orthop Trauma Surg. 2006;126:77–81.PubMedCrossRef Roth A, Winzer T, Sander K, Anders JO, Venbrocks RA. Press fit fixation of cementless cups: how much stability do we need indeed? Arch Orthop Trauma Surg. 2006;126:77–81.PubMedCrossRef
37.
go back to reference Shon WY, Gupta S, Biswal S, Han SH, Hong SJ, Moon JG. Pelvic osteolysis relationship to radiographs and polyethylene wear. J Arthroplasty. 2009;24:743–750.PubMedCrossRef Shon WY, Gupta S, Biswal S, Han SH, Hong SJ, Moon JG. Pelvic osteolysis relationship to radiographs and polyethylene wear. J Arthroplasty. 2009;24:743–750.PubMedCrossRef
38.
go back to reference Stihsen C, Pabinger C, Radl R, Rehak P, Windhager R. Migration of the Duraloc cup after 5 years. Int Orthop. 2008;32:791–794.PubMedCrossRef Stihsen C, Pabinger C, Radl R, Rehak P, Windhager R. Migration of the Duraloc cup after 5 years. Int Orthop. 2008;32:791–794.PubMedCrossRef
39.
go back to reference Stöckl B, Sandow M, Krismer M, Biedermann R, Wimmer C, Frischhut B. Migration of the Duraloc cup at two years. J Bone Joint Surg Br. 1999;81:51–53.PubMedCrossRef Stöckl B, Sandow M, Krismer M, Biedermann R, Wimmer C, Frischhut B. Migration of the Duraloc cup at two years. J Bone Joint Surg Br. 1999;81:51–53.PubMedCrossRef
40.
go back to reference Sychterz CJ, Claus AM, Engh CA. What we have learned about long-term cementless fixation from autopsy retrievals. Clin Orthop Relat Res. 2002;405:79–91.PubMedCrossRef Sychterz CJ, Claus AM, Engh CA. What we have learned about long-term cementless fixation from autopsy retrievals. Clin Orthop Relat Res. 2002;405:79–91.PubMedCrossRef
41.
go back to reference Udomkiat P, Dorr LD, Wan Z. Cementless hemispheric porous-coated sockets implanted with press-fit technique without screws: average ten-year follow-up. J Bone Joint Surg Am. 2002;84:1195–1200.PubMed Udomkiat P, Dorr LD, Wan Z. Cementless hemispheric porous-coated sockets implanted with press-fit technique without screws: average ten-year follow-up. J Bone Joint Surg Am. 2002;84:1195–1200.PubMed
42.
go back to reference Wasielewski RC, Crossett LS, Rubash HE. Neural and vascular injury in total hip arthroplasty. Orthop Clin North Am. 1992;23:219–235.PubMed Wasielewski RC, Crossett LS, Rubash HE. Neural and vascular injury in total hip arthroplasty. Orthop Clin North Am. 1992;23:219–235.PubMed
43.
go back to reference Zicat B, Engh CA, Gokcen E. Patterns of osteolysis around total hip components inserted with and without cement. J Bone Joint Surg Am. 1995;77:432–439.PubMed Zicat B, Engh CA, Gokcen E. Patterns of osteolysis around total hip components inserted with and without cement. J Bone Joint Surg Am. 1995;77:432–439.PubMed
Metadata
Title
The Effect of Poly Sterilization on Wear, Osteolysis and Survivorship of a Press-fit Cup at 10-Year Followup
Authors
Charles A. Engh, MD
Cara C. Powers, MD
Henry Ho, MS
Sarah E. Beykirch-Padgett, BS
Robert H. Hopper Jr, PhD
C. Anderson Engh Jr, MD
Publication date
01-02-2012
Publisher
Springer-Verlag
Published in
Clinical Orthopaedics and Related Research® / Issue 2/2012
Print ISSN: 0009-921X
Electronic ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-011-2052-2

Other articles of this Issue 2/2012

Clinical Orthopaedics and Related Research® 2/2012 Go to the issue

Symposium: Papers Presented at the Annual Meetings of The Hip Society

Tantalum Augments for Paprosky IIIA Defects Remain Stable at Midterm Followup

Symposium: Papers Presented at the Annual Meetings of The Hip Society

Increased Anteversion of Press-fit Femoral Stems Compared With Anatomic Femur

Symposium: Papers Presented at the Annual Meetings of The Hip Society

Age and Obesity Are Risk Factors for Adverse Events After Total Hip Arthroplasty

Symposium: Papers Presented at the Annual Meetings of The Hip Society

A More Reliable Method to Assess Acetabular Component Position