Skip to main content
Top
Published in: Clinical Orthopaedics and Related Research® 2/2012

01-02-2012 | Symposium: Papers Presented at the Annual Meetings of The Hip Society

Increased Anteversion of Press-fit Femoral Stems Compared With Anatomic Femur

Author: Roger H. Emerson Jr, MD

Published in: Clinical Orthopaedics and Related Research® | Issue 2/2012

Login to get access

Abstract

Background

With contemporary canal-filling press-fit stems, there is no adjustability of stem position in the canal and therefore the canal anatomy determines stem version. Stem version will affect head/neck impingement, polyethylene wear from edge loading, and hip stability, but despite this, the postoperative version of a canal-filling press-fit stem is unclear.

Questions/purposes

Is there a difference between the version of the nonoperated femur and the final version of a canal-filling press-fit femoral component? Could a difference create an alignment problem for the hip replacement?

Methods

Sixty-four hips were studied with fluoroscopy and 46 nonarthritic and 41 arthritic hips were studied with MRI. A standardized fluoroscopic technique for determining preoperative and postoperative femoral version was developed with the patient supine on a fracture table undergoing supine total hip arthroplasty. To validate the methods, the results were compared with two selected series of axial MRI views of the hip comparing the version of the head with the version of the canal at the base of the neck.

Results

For the operated hips, the mean anatomic hip version was less than the stem version: 18.9° versus 27.0°. The difference on average was 8.1° of increased anteversion (SD, 7.4°). Both MRI series showed the femoral neck was more anteverted on average than the femoral head, thereby explaining the operative findings.

Conclusion

With a canal-filling press-fit femoral component there is wide variation of postoperative component anteversion with most stems placed in increased anteversion compared with the anatomic head. The surgical technique may need to adjust for this if causing intraoperative impingement or instability.
Literature
1.
go back to reference Braten M, Terjesen T, Rossvoll I. Femoral anteversion in normal adults. Ultrasound measurements in 50 men and 50 women. Acta Orthop Scand. 1992;63:29–32.PubMedCrossRef Braten M, Terjesen T, Rossvoll I. Femoral anteversion in normal adults. Ultrasound measurements in 50 men and 50 women. Acta Orthop Scand. 1992;63:29–32.PubMedCrossRef
2.
go back to reference D’Lima DD, Urguart AG, Buehler KO, Walker RH, Colwell CW. The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios. J Bone Joint Surg Am. 2000;82:315–321.PubMed D’Lima DD, Urguart AG, Buehler KO, Walker RH, Colwell CW. The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios. J Bone Joint Surg Am. 2000;82:315–321.PubMed
3.
go back to reference Dorr LD, Malik A, Dastane M, Zhinian W. Combined anteversion technique for total hip arthroplasty. Clin Orthop Relat Res. 2009;467:1528–1132.CrossRef Dorr LD, Malik A, Dastane M, Zhinian W. Combined anteversion technique for total hip arthroplasty. Clin Orthop Relat Res. 2009;467:1528–1132.CrossRef
4.
go back to reference Dorr LD, Wan Z, Malik A, Dastane M, Deshmane P. A comparison of surgeon estimation and computed tomographic measurement of femoral component anteversion in cementless total hip arthroplasty. J Bone Joint Surg Am. 2009;91:2598–2604.PubMedCrossRef Dorr LD, Wan Z, Malik A, Dastane M, Deshmane P. A comparison of surgeon estimation and computed tomographic measurement of femoral component anteversion in cementless total hip arthroplasty. J Bone Joint Surg Am. 2009;91:2598–2604.PubMedCrossRef
5.
go back to reference Eckrich SG, Noble PC, Tullos HS. Effect of rotation on the radiographic. Appearance of the femoral canal. J Arthroplasty. 1994;9:419–426.CrossRef Eckrich SG, Noble PC, Tullos HS. Effect of rotation on the radiographic. Appearance of the femoral canal. J Arthroplasty. 1994;9:419–426.CrossRef
6.
go back to reference Kamizis IA. A technique for accurate reproduction of the femoral anteversion during primary total hip arthroplasty. Arch Orthop Trauma Surg. 2001;121:343–345.CrossRef Kamizis IA. A technique for accurate reproduction of the femoral anteversion during primary total hip arthroplasty. Arch Orthop Trauma Surg. 2001;121:343–345.CrossRef
7.
go back to reference Maheshwari AV, Zlowodzki MP, Siram G, Jain AK. Femoral neck anteversion, acetabular anteversion and combined anteversion in the normal Indian adult population: a computed tomographic study. Indian J Orthop. 2010;44:277–282.PubMedCrossRef Maheshwari AV, Zlowodzki MP, Siram G, Jain AK. Femoral neck anteversion, acetabular anteversion and combined anteversion in the normal Indian adult population: a computed tomographic study. Indian J Orthop. 2010;44:277–282.PubMedCrossRef
8.
go back to reference Maruyama M, Feinberg JR, Capello WN, D’Antonio JA. The Frank Stinchfield Award: Morphologic features of the acetabulum and femur: anteversion angle and implant positioning. Clin Orthop Relat Res. 2001;393:52–65.PubMedCrossRef Maruyama M, Feinberg JR, Capello WN, D’Antonio JA. The Frank Stinchfield Award: Morphologic features of the acetabulum and femur: anteversion angle and implant positioning. Clin Orthop Relat Res. 2001;393:52–65.PubMedCrossRef
9.
go back to reference Patel AB, Wagle RR, Usrey MM, Thompson MT, Incavo SJ, Noble PC. Guidelines for implant placement to minimize impingement during activities of daily living after total hip arthroplasty. J Arthroplasty. 2010;25:1275–1281.PubMedCrossRef Patel AB, Wagle RR, Usrey MM, Thompson MT, Incavo SJ, Noble PC. Guidelines for implant placement to minimize impingement during activities of daily living after total hip arthroplasty. J Arthroplasty. 2010;25:1275–1281.PubMedCrossRef
10.
go back to reference Reikeras O, Bjerkreim I, Kolbenstvedt A. Anteversion of the acetabulum and femoral neck in normals and in patients with osteoarthritis of the hip. Acta Orthop Scand. 1983;54:18–23.PubMedCrossRef Reikeras O, Bjerkreim I, Kolbenstvedt A. Anteversion of the acetabulum and femoral neck in normals and in patients with osteoarthritis of the hip. Acta Orthop Scand. 1983;54:18–23.PubMedCrossRef
11.
go back to reference Reikeras O, Hoiseth A. Femoral neck angles in osteoarthritis of the hip. Acta Orthop Scand. 1982;53:781–784.PubMedCrossRef Reikeras O, Hoiseth A. Femoral neck angles in osteoarthritis of the hip. Acta Orthop Scand. 1982;53:781–784.PubMedCrossRef
12.
go back to reference Rothstein JM, Miller PJ, Roettger RF. Goniometric reliability in a clinical setting. Elbow and knee measurements. Phys Ther. 1983;63:1611–1615.PubMed Rothstein JM, Miller PJ, Roettger RF. Goniometric reliability in a clinical setting. Elbow and knee measurements. Phys Ther. 1983;63:1611–1615.PubMed
13.
go back to reference Sendtner E, Müller M, Winkler R, Wörner M, Grifka J, Renkawitz T. Femur first in hip arthroplasty—the concept of combined anteversion. Z Orthop Unfall. 2010;148:185–190.PubMedCrossRef Sendtner E, Müller M, Winkler R, Wörner M, Grifka J, Renkawitz T. Femur first in hip arthroplasty—the concept of combined anteversion. Z Orthop Unfall. 2010;148:185–190.PubMedCrossRef
14.
go back to reference Suh KT, Kang JH, Roh HL, Moon KP, Kim HJ. True femoral anteversion during primary total hip arthroplasty: use of postoperative computed tomography-based sections. J Arthroplasty. 2006;21:599–605.PubMedCrossRef Suh KT, Kang JH, Roh HL, Moon KP, Kim HJ. True femoral anteversion during primary total hip arthroplasty: use of postoperative computed tomography-based sections. J Arthroplasty. 2006;21:599–605.PubMedCrossRef
15.
go back to reference Widmer KH, Zurfluh B. Compliant positioning of total hip components for optimal range of motion. J Orthop Res. 2004;22:815–821.PubMedCrossRef Widmer KH, Zurfluh B. Compliant positioning of total hip components for optimal range of motion. J Orthop Res. 2004;22:815–821.PubMedCrossRef
16.
go back to reference Wines AP, McNicol D. Computed tomography measurement of the accuracy of component version in total hip arthroplasty. J Arthroplasty. 2006;21:696–701.PubMedCrossRef Wines AP, McNicol D. Computed tomography measurement of the accuracy of component version in total hip arthroplasty. J Arthroplasty. 2006;21:696–701.PubMedCrossRef
Metadata
Title
Increased Anteversion of Press-fit Femoral Stems Compared With Anatomic Femur
Author
Roger H. Emerson Jr, MD
Publication date
01-02-2012
Publisher
Springer-Verlag
Published in
Clinical Orthopaedics and Related Research® / Issue 2/2012
Print ISSN: 0009-921X
Electronic ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-011-1993-9

Other articles of this Issue 2/2012

Clinical Orthopaedics and Related Research® 2/2012 Go to the issue

Symposium: Papers Presented at the Annual Meetings of The Hip Society

Ceramic Bearings for Total Hip Arthroplasty Have High Survivorship at 10 Years

Symposium: Papers Presented at the Annual Meetings of The Hip Society

Incidence of Contralateral THA After Index THA for Osteoarthritis

Symposium: Papers Presented at the Annual Meetings of The Hip Society

Factors Affecting Modular Acetabular Ceramic Liner Insertion: A Biomechanical Analysis