Skip to main content
Top
Published in: Clinical Orthopaedics and Related Research® 6/2011

01-06-2011 | Symposium: Update on Hard-on-Hard Bearings in Hip Arthroplasty

Intraoperative Radiographs for Placing Acetabular Components in Hip Resurfacing Arthroplasty

Authors: Thomas P. Gross, MD, Fei Liu, PhD, Lee Webb, NP

Published in: Clinical Orthopaedics and Related Research® | Issue 6/2011

Login to get access

Abstract

Background

Various clinical and biomechanical studies suggest certain acetabular positions may be associated with higher wear and failure rates in modern metal-on-metal hip resurfacing arthroplasties. However, there are no widely available, reliable, and cost-effective surgical techniques that ensure surgeons are able to place an acetabular component within the safe range of inclination angles after hip resurfacing surgeries.

Questions/purposes

We investigated the accuracy of intraoperative radiographs to determine the acetabular inclination angle in resurfacing arthroplasty procedures.

Patients and Methods

The study group included the first 100 resurfacing arthroplasties performed after we started routinely checking the intraoperative acetabular inclination angles. The acetabular component was repositioned if the intraoperative acetabular inclination angle was out of the target range of 30° to 50°. The control group included the previous 100 resurfacing arthroplasties performed without the benefit of intraoperative radiographs. A posterior minimally invasive surgical approach was used in both groups. Demographics and diagnoses were similar in both groups.

Results

The average (± SD) difference between the intraoperative and 6-week radiographs was 2.7° ± 2.5°. The acetabular inclination angles at 6-week followup were within the targeted range more frequently in the study group than in the control group (outliers: 4% versus 29%).

Conclusions

These data suggest a single intraoperative radiograph is a quick, reliable, and cost-effective method for ensuring the acetabular inclination angle is within the targeted range.

Level of Evidence

Level III, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
Literature
1.
go back to reference Tamhane AC, Dunlop DD. Statistics and Data Analysis: From Elementary to Intermediate. Upper Saddle River, NJ: Prentice Hall; 2000. Tamhane AC, Dunlop DD. Statistics and Data Analysis: From Elementary to Intermediate. Upper Saddle River, NJ: Prentice Hall; 2000.
2.
go back to reference Amstutz HC, Le Duff MJ. Eleven years of experience with metal-on-metal hybrid hip resurfacing: a review of 1000 Conserve Plus. J Arthroplasty. 2008;23:36–43.PubMedCrossRef Amstutz HC, Le Duff MJ. Eleven years of experience with metal-on-metal hybrid hip resurfacing: a review of 1000 Conserve Plus. J Arthroplasty. 2008;23:36–43.PubMedCrossRef
3.
go back to reference Brodner W, Grubl A, Jankovsky R, Meisinger V, Lehr S, Gottsauner-Wolf F. Cup inclination and serum concentration of cobalt and chromium after metal-on-metal total hip arthroplasty. J Arthroplasty. 2004;19:66–70.PubMedCrossRef Brodner W, Grubl A, Jankovsky R, Meisinger V, Lehr S, Gottsauner-Wolf F. Cup inclination and serum concentration of cobalt and chromium after metal-on-metal total hip arthroplasty. J Arthroplasty. 2004;19:66–70.PubMedCrossRef
4.
go back to reference Campbell P, Beaule PE, Ebramzadeh E, LeDuff M, De Smet K, Lu Z, Amstutz HC. The John Charnley Award. A study of implant failure in metal-on-metal surface arthroplasties. Clin Orthop Relat Res. 2006;453:35–46. Campbell P, Beaule PE, Ebramzadeh E, LeDuff M, De Smet K, Lu Z, Amstutz HC. The John Charnley Award. A study of implant failure in metal-on-metal surface arthroplasties. Clin Orthop Relat Res. 2006;453:35–46.
5.
go back to reference Cerha O, Kirschner S, Gunther KP, Lutzner J. Cost analysis for navigation in knee endoprosthetics. Orthopade. 2009;38:1235–1240.PubMedCrossRef Cerha O, Kirschner S, Gunther KP, Lutzner J. Cost analysis for navigation in knee endoprosthetics. Orthopade. 2009;38:1235–1240.PubMedCrossRef
6.
go back to reference Crowninshield RD, Maloney WJ, Wentz DH, Humphrey SM, Blanchard CR. Biomechanics of large femoral heads: what they do and don’t do. Clin Orthop Relat Res. 2004;429:102–107.PubMedCrossRef Crowninshield RD, Maloney WJ, Wentz DH, Humphrey SM, Blanchard CR. Biomechanics of large femoral heads: what they do and don’t do. Clin Orthop Relat Res. 2004;429:102–107.PubMedCrossRef
7.
go back to reference Daniel J, Pynsent PB, McMinn DJ. Metal-on-metal resurfacing of the hip in patients under the age of 55 years with osteoarthritis. J Bone Joint Surg Br. 2004;86:177–184.PubMedCrossRef Daniel J, Pynsent PB, McMinn DJ. Metal-on-metal resurfacing of the hip in patients under the age of 55 years with osteoarthritis. J Bone Joint Surg Br. 2004;86:177–184.PubMedCrossRef
8.
go back to reference De Haan R, Campbell PA, Su EP, De Smet KA. Revision of metal-on-metal resurfacing arthroplasty of the hip: the influence of malpositioning of the components. J Bone Joint Surg Br. 2008;90:1158–1163.PubMedCrossRef De Haan R, Campbell PA, Su EP, De Smet KA. Revision of metal-on-metal resurfacing arthroplasty of the hip: the influence of malpositioning of the components. J Bone Joint Surg Br. 2008;90:1158–1163.PubMedCrossRef
9.
go back to reference De Haan R, Pattyn C, Gill HS, Murray DW, Campbell PA, De Smet K. Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement. J Bone Joint Surg Br. 2008;90:1291–1297.PubMedCrossRef De Haan R, Pattyn C, Gill HS, Murray DW, Campbell PA, De Smet K. Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement. J Bone Joint Surg Br. 2008;90:1291–1297.PubMedCrossRef
10.
go back to reference DiGioia AM, Jaramaz B, Blackwell M, Simon DA, Morgan F, Moody JE, Nikou C, Colgan BD, Aston CA, Labarca RS, Kischell E, Kanade T. The Otto Aufranc Award. Image guided navigation system to measure intraoperatively acetabular implant alignment. Clin Orthop Relat Res. 1998;355:8–22. DiGioia AM, Jaramaz B, Blackwell M, Simon DA, Morgan F, Moody JE, Nikou C, Colgan BD, Aston CA, Labarca RS, Kischell E, Kanade T. The Otto Aufranc Award. Image guided navigation system to measure intraoperatively acetabular implant alignment. Clin Orthop Relat Res. 1998;355:8–22.
11.
go back to reference Gross TP, Liu F. Metal-on-metal hip resurfacing with an uncemented femoral component: a seven-year follow-up study. J Bone Joint Surg Am. 2008;90(Suppl 3):32–37.PubMedCrossRef Gross TP, Liu F. Metal-on-metal hip resurfacing with an uncemented femoral component: a seven-year follow-up study. J Bone Joint Surg Am. 2008;90(Suppl 3):32–37.PubMedCrossRef
12.
go back to reference Haaker RG, Tiedjen K, Ottersbach A, Rubenthaler F, Stockheim M, Stiehl JB. Comparison of conventional versus computer-navigated acetabular component insertion. J Arthroplasty. 2007;22:151–159.PubMedCrossRef Haaker RG, Tiedjen K, Ottersbach A, Rubenthaler F, Stockheim M, Stiehl JB. Comparison of conventional versus computer-navigated acetabular component insertion. J Arthroplasty. 2007;22:151–159.PubMedCrossRef
13.
go back to reference Hart AJ, Buddhdev P, Winship P, Faria N, Powell JJ, Skinner JA. Cup inclination angle of greater than 50 degrees increases whole blood concentrations of cobalt and chromium ions after metal-on-metal hip resurfacing. Hip Int. 2008;18:212–219.PubMed Hart AJ, Buddhdev P, Winship P, Faria N, Powell JJ, Skinner JA. Cup inclination angle of greater than 50 degrees increases whole blood concentrations of cobalt and chromium ions after metal-on-metal hip resurfacing. Hip Int. 2008;18:212–219.PubMed
14.
go back to reference Hassan DM, Johnston GH, Dust WN, Watson G, Dolovich AT. Accuracy of intraoperative assessment of acetabular prosthesis placement. J Arthroplasty. 1998;13:80–84.PubMedCrossRef Hassan DM, Johnston GH, Dust WN, Watson G, Dolovich AT. Accuracy of intraoperative assessment of acetabular prosthesis placement. J Arthroplasty. 1998;13:80–84.PubMedCrossRef
15.
go back to reference Hing CB, Back DL, Bailey M, Young DA, Dalziel RE, Shimmin AJ. The results of primary Birmingham hip resurfacings at a mean of five years: an independent prospective review of the first 230 hips. J Bone Joint Surg Br. 2007;89:1431–1438.PubMedCrossRef Hing CB, Back DL, Bailey M, Young DA, Dalziel RE, Shimmin AJ. The results of primary Birmingham hip resurfacings at a mean of five years: an independent prospective review of the first 230 hips. J Bone Joint Surg Br. 2007;89:1431–1438.PubMedCrossRef
16.
go back to reference Kalteis T, Handel M, Herold T, Perlick L, Baethis H, Grifka J. Greater accuracy in positioning of the acetabular cup by using an image-free navigation system. Int Orthop. 2005;29:272–276.PubMedCrossRef Kalteis T, Handel M, Herold T, Perlick L, Baethis H, Grifka J. Greater accuracy in positioning of the acetabular cup by using an image-free navigation system. Int Orthop. 2005;29:272–276.PubMedCrossRef
17.
go back to reference Kalteis T, Handel M, Herold T, Perlick L, Paetzel C, Grifka J. Position of the acetabular cup—accuracy of radiographic calculation compared to CT-based measurement. Eur J Radiol. 2006;58:294–300.PubMedCrossRef Kalteis T, Handel M, Herold T, Perlick L, Paetzel C, Grifka J. Position of the acetabular cup—accuracy of radiographic calculation compared to CT-based measurement. Eur J Radiol. 2006;58:294–300.PubMedCrossRef
18.
go back to reference Konig DP, Michael JW, Eysel P, Munnich U, Lichtenstein T, Schnurr C. Computer-assisted joint replacement surgery: financial and clinical impact for a specialised orthopaedic hospital. Z Orthop Unfall. 2009;147:669–674.PubMedCrossRef Konig DP, Michael JW, Eysel P, Munnich U, Lichtenstein T, Schnurr C. Computer-assisted joint replacement surgery: financial and clinical impact for a specialised orthopaedic hospital. Z Orthop Unfall. 2009;147:669–674.PubMedCrossRef
19.
go back to reference Kruger S, Zambelli PY, Leyvraz PF, Jolles BM. Computer-assisted placement technique in hip resurfacing arthroplasty: improvement in accuracy? Int Orthop. 2009;33:27–33.PubMedCrossRef Kruger S, Zambelli PY, Leyvraz PF, Jolles BM. Computer-assisted placement technique in hip resurfacing arthroplasty: improvement in accuracy? Int Orthop. 2009;33:27–33.PubMedCrossRef
20.
go back to reference Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR. Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am. 1978;60:217–220.PubMed Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR. Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am. 1978;60:217–220.PubMed
21.
go back to reference Mont MA, Schmalzried TP. Modern metal-on-metal hip resurfacing: important observations from the first ten years. J Bone Joint Surg Am. 2008;90(Suppl 3):3–11.PubMedCrossRef Mont MA, Schmalzried TP. Modern metal-on-metal hip resurfacing: important observations from the first ten years. J Bone Joint Surg Am. 2008;90(Suppl 3):3–11.PubMedCrossRef
22.
go back to reference Patil S, Bergula A, Chen PC, Colwell CW Jr, D’Lima DD. Polyethylene wear and acetabular component orientation. J Bone Joint Surg Am. 2003;85(Suppl 4):56–63.PubMed Patil S, Bergula A, Chen PC, Colwell CW Jr, D’Lima DD. Polyethylene wear and acetabular component orientation. J Bone Joint Surg Am. 2003;85(Suppl 4):56–63.PubMed
23.
go back to reference Resubal JR, Morgan DA. Computer-assisted vs conventional mechanical jig technique in hip resurfacing arthroplasty. J Arthroplasty. 2009;24:341–350.PubMedCrossRef Resubal JR, Morgan DA. Computer-assisted vs conventional mechanical jig technique in hip resurfacing arthroplasty. J Arthroplasty. 2009;24:341–350.PubMedCrossRef
24.
go back to reference Romanowski JR, Swank ML. Imageless navigation in hip resurfacing: avoiding component malposition during the surgeon learning curve. J Bone Joint Surg Am. 2008;90(Suppl 3):65–70.PubMedCrossRef Romanowski JR, Swank ML. Imageless navigation in hip resurfacing: avoiding component malposition during the surgeon learning curve. J Bone Joint Surg Am. 2008;90(Suppl 3):65–70.PubMedCrossRef
25.
go back to reference Saxler G, Marx A, Vandevelde D, Langlotz U, Tannast M, Wiese M, Michaelis U, Kemper G, Grutzner PA, Steffen R, von Knoch M, Holland-Letz T, Bernsmann K. The accuracy of free-hand cup positioning—a CT based measurement of cup placement in 105 total hip arthroplasties. Int Orthop. 2004;28:198–201.PubMedCrossRef Saxler G, Marx A, Vandevelde D, Langlotz U, Tannast M, Wiese M, Michaelis U, Kemper G, Grutzner PA, Steffen R, von Knoch M, Holland-Letz T, Bernsmann K. The accuracy of free-hand cup positioning—a CT based measurement of cup placement in 105 total hip arthroplasties. Int Orthop. 2004;28:198–201.PubMedCrossRef
26.
go back to reference Schnurr C, Michael JW, Eysel P, Konig DP. Imageless navigation of hip resurfacing arthroplasty increases the implant accuracy. Int Orthop. 2009;33:365–372.PubMedCrossRef Schnurr C, Michael JW, Eysel P, Konig DP. Imageless navigation of hip resurfacing arthroplasty increases the implant accuracy. Int Orthop. 2009;33:365–372.PubMedCrossRef
27.
go back to reference Seyler TM, Lai LP, Sprinkle DI, Ward WG, Jinnah RH. Does computer-assisted surgery improve accuracy and decrease the learning curve in hip resurfacing? A radiographic analysis. J Bone Joint Surg Am. 2008;90(Suppl 3):71–80.PubMedCrossRef Seyler TM, Lai LP, Sprinkle DI, Ward WG, Jinnah RH. Does computer-assisted surgery improve accuracy and decrease the learning curve in hip resurfacing? A radiographic analysis. J Bone Joint Surg Am. 2008;90(Suppl 3):71–80.PubMedCrossRef
28.
go back to reference Steffen RT, Pandit HP, Palan J, Beard DJ, Gundle R, McLardy-Smith P, Murray DW, Gill HS. The five-year results of the Birmingham Hip Resurfacing arthroplasty: an independent series. J Bone Joint Surg Br. 2008;90:436–441.PubMedCrossRef Steffen RT, Pandit HP, Palan J, Beard DJ, Gundle R, McLardy-Smith P, Murray DW, Gill HS. The five-year results of the Birmingham Hip Resurfacing arthroplasty: an independent series. J Bone Joint Surg Br. 2008;90:436–441.PubMedCrossRef
29.
go back to reference Wan Z, Malik A, Jaramaz B, Chao L, Dorr LD. Imaging and navigation measurement of acetabular component position in THA. Clin Orthop Relat Res. 2009;467:32–42.PubMedCrossRef Wan Z, Malik A, Jaramaz B, Chao L, Dorr LD. Imaging and navigation measurement of acetabular component position in THA. Clin Orthop Relat Res. 2009;467:32–42.PubMedCrossRef
30.
go back to reference Williams D, Royle M, Norton M. Metal-on-metal hip resurfacing: the effect of cup position and component size on range of motion to impingement. J Arthroplasty. 2009;24:144–151.PubMedCrossRef Williams D, Royle M, Norton M. Metal-on-metal hip resurfacing: the effect of cup position and component size on range of motion to impingement. J Arthroplasty. 2009;24:144–151.PubMedCrossRef
31.
go back to reference Williams S, Leslie I, Isaac G, Jin Z, Ingham E, Fisher J. Tribology and wear of metal-on-metal hip prostheses: influence of cup angle and head position. J Bone Joint Surg Am. 2008;90(Suppl 3):111–117.PubMedCrossRef Williams S, Leslie I, Isaac G, Jin Z, Ingham E, Fisher J. Tribology and wear of metal-on-metal hip prostheses: influence of cup angle and head position. J Bone Joint Surg Am. 2008;90(Suppl 3):111–117.PubMedCrossRef
32.
go back to reference Wines AP, McNicol D. Computed tomography measurement of the accuracy of component version in total hip arthroplasty. J Arthroplasty. 2006;21:696–701.PubMedCrossRef Wines AP, McNicol D. Computed tomography measurement of the accuracy of component version in total hip arthroplasty. J Arthroplasty. 2006;21:696–701.PubMedCrossRef
33.
go back to reference Witzleb WC, Hanisch U, Ziegler J, Guenther KP. In vivo wear rate of the Birmingham Hip Resurfacing arthroplasty: a review of 10 retrieved components. J Arthroplasty. 2009;24:951–956.PubMedCrossRef Witzleb WC, Hanisch U, Ziegler J, Guenther KP. In vivo wear rate of the Birmingham Hip Resurfacing arthroplasty: a review of 10 retrieved components. J Arthroplasty. 2009;24:951–956.PubMedCrossRef
34.
go back to reference Ybinger T, Kumpan W, Hoffart HE, Muschalik B, Bullmann W, Zweymuller K. Accuracy of navigation-assisted acetabular component positioning studied by computed tomography measurements: methods and results. J Arthroplasty. 2007;22:812–817.PubMedCrossRef Ybinger T, Kumpan W, Hoffart HE, Muschalik B, Bullmann W, Zweymuller K. Accuracy of navigation-assisted acetabular component positioning studied by computed tomography measurements: methods and results. J Arthroplasty. 2007;22:812–817.PubMedCrossRef
Metadata
Title
Intraoperative Radiographs for Placing Acetabular Components in Hip Resurfacing Arthroplasty
Authors
Thomas P. Gross, MD
Fei Liu, PhD
Lee Webb, NP
Publication date
01-06-2011
Publisher
Springer-Verlag
Published in
Clinical Orthopaedics and Related Research® / Issue 6/2011
Print ISSN: 0009-921X
Electronic ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-010-1701-1

Other articles of this Issue 6/2011

Clinical Orthopaedics and Related Research® 6/2011 Go to the issue

Symposium: Update on Hard-on-Hard Bearings in Hip Arthroplasty

A Squeaky Reputation: The Problem May Be Design-dependent

Symposium: Update on Hard-on-Hard Bearings in Hip Arthroplasty

Direct Anterior Approach for Hip Resurfacing: Surgical Technique and Complications

Symposium: Update on Hard-on-Hard Bearings in Hip Arthroplasty

Is Resurfacing Arthroplasty Appropriate for Posttraumatic Osteoarthritis?