Skip to main content
Top
Published in: International Orthopaedics 4/2004

01-08-2004 | Original Paper

The accuracy of free-hand cup positioning - a CT based measurement of cup placement in 105 total hip arthroplasties

Authors: G. Saxler, A. Marx, D. Vandevelde, U. Langlotz, M. Tannast, M. Wiese, U. Michaelis, G. Kemper, P. A. Grützner, R. Steffen, M. von Knoch, T. Holland-Letz, K. Bernsmann

Published in: International Orthopaedics | Issue 4/2004

Login to get access

Abstract

We studied 105 patients who received a total hip arthroplasty between June 1985 and August 2001 using freehand positioning of the acetabular cup. Using pelvic CT scan and the hip-plan module of SurgiGATE-System (Medivision, Oberdorf, Switzerland), we measured the angles of inclination and anteversion of the cup. Mean inclination angle was 45.8°±10.1° (range: 23.0–71.5°) and mean anteversion angle was 27.3°±15.0° (range: −23.5° to 59.0°). We compared the results to the “safe” position as defined by Lewinnek et al. and found that only 27/105 cups were implanted within the limits of the safe position. We conclude that a safe position as defined by Lewinnek et al. [13] was only achieved in a minority of the cups that were implanted freehand.
Literature
1.
go back to reference Bernsmann K, Langlotz U, Ansari B, Wiese M (2001) Computer-assisted navigated cup placement of different cup types in hip arthroplasty-a randomised controlled trial. Z Orthop Ihre Grenzgeb 139:512–517CrossRefPubMed Bernsmann K, Langlotz U, Ansari B, Wiese M (2001) Computer-assisted navigated cup placement of different cup types in hip arthroplasty-a randomised controlled trial. Z Orthop Ihre Grenzgeb 139:512–517CrossRefPubMed
2.
go back to reference Coventry MB, Beckenbaugh RD, Nolan DR, Ilstrup DM (1974) 2,012 total hip arthroplasties. A study of postoperative course and early complications. J Bone Joint Surg [Am] 56:273–284 Coventry MB, Beckenbaugh RD, Nolan DR, Ilstrup DM (1974) 2,012 total hip arthroplasties. A study of postoperative course and early complications. J Bone Joint Surg [Am] 56:273–284
3.
go back to reference DiGioia AM, Jaramaz B, Blackwell M, Simon DA, Morgan F, Moody JE, Nikou C, Colgan BD, Aston CA, Labarca RS, Kischell E, Kanade T (1998) The Otto Aufranc Award. Image guided navigation system to measure intraoperatively acetabular implant alignment. Clin Orthop 355:8-22PubMed DiGioia AM, Jaramaz B, Blackwell M, Simon DA, Morgan F, Moody JE, Nikou C, Colgan BD, Aston CA, Labarca RS, Kischell E, Kanade T (1998) The Otto Aufranc Award. Image guided navigation system to measure intraoperatively acetabular implant alignment. Clin Orthop 355:8-22PubMed
4.
go back to reference Harris WH (1980) Advances in surgical technique for total hip replacement: without and with osteotomy of the greater trochanter. Clin Orthop 146:188–204PubMed Harris WH (1980) Advances in surgical technique for total hip replacement: without and with osteotomy of the greater trochanter. Clin Orthop 146:188–204PubMed
5.
go back to reference Herrlin K, Pettersson H, Selvik G (1988) Comparison of two- and three-dimensional methods for assessment of orientation of the total hip prosthesis. Acta Radiol 29:357–361PubMed Herrlin K, Pettersson H, Selvik G (1988) Comparison of two- and three-dimensional methods for assessment of orientation of the total hip prosthesis. Acta Radiol 29:357–361PubMed
6.
go back to reference Hirakawa K, Mitsugi N, Koshino T, Saito T, Hirasawa Y, Kubo T (2001) Effect of acetabular cup position and orientation in cemented total hip arthroplasty. Clin Orthop 388:135–142PubMed Hirakawa K, Mitsugi N, Koshino T, Saito T, Hirasawa Y, Kubo T (2001) Effect of acetabular cup position and orientation in cemented total hip arthroplasty. Clin Orthop 388:135–142PubMed
7.
go back to reference Jaramaz B, DiGioia AM 3rd, Blackwell M, Nikou C (1998) Computer assisted measurement of cup placement in total hip replacement. Clin Orthop 354:70–81PubMed Jaramaz B, DiGioia AM 3rd, Blackwell M, Nikou C (1998) Computer assisted measurement of cup placement in total hip replacement. Clin Orthop 354:70–81PubMed
8.
go back to reference Jolles BM, Genoud P, Hoffmeyer P (2001) Accuracy of computer – assisted cup placement in total hip arthroplasty. International Congress Series 1230:314–318CrossRef Jolles BM, Genoud P, Hoffmeyer P (2001) Accuracy of computer – assisted cup placement in total hip arthroplasty. International Congress Series 1230:314–318CrossRef
9.
go back to reference Joshi A, Lee CM, Markovic L, Vlatis G, Murphy JC (1998) Prognosis of dislocation after total hip arthroplasty. J Arthroplasty 13:17–21 Joshi A, Lee CM, Markovic L, Vlatis G, Murphy JC (1998) Prognosis of dislocation after total hip arthroplasty. J Arthroplasty 13:17–21
10.
go back to reference Kohn D, Ruhmann O, Wirth CJ (1997) Dislocation of total hip endoprosthesis with special reference to various techniques. Z Orthop Ihre Grenzgeb 135:40–44PubMed Kohn D, Ruhmann O, Wirth CJ (1997) Dislocation of total hip endoprosthesis with special reference to various techniques. Z Orthop Ihre Grenzgeb 135:40–44PubMed
11.
go back to reference Langlotz U, Lawrence J, Hu Q, Langlotz F, Nolte LP (1999) Image guided cup placement. Amsterdam, Elsevier Langlotz U, Lawrence J, Hu Q, Langlotz F, Nolte LP (1999) Image guided cup placement. Amsterdam, Elsevier
12.
go back to reference Leenders T, Vandevelde D, Mahieu G, Nuyts R (2002) Reduction in variability of acetabular cup abduction using computer assisted surgery: A prospective and randomized study. Comput Aided Surg 7:99–106 Leenders T, Vandevelde D, Mahieu G, Nuyts R (2002) Reduction in variability of acetabular cup abduction using computer assisted surgery: A prospective and randomized study. Comput Aided Surg 7:99–106
13.
go back to reference Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmermann JR (1978) Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg [Am] 60:217–220 Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmermann JR (1978) Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg [Am] 60:217–220
14.
go back to reference McCollum DE, Gray WJ (1990) Dislocation after total hip arthroplasty. Causes and prevention. Clin Orthop 261:159–170PubMed McCollum DE, Gray WJ (1990) Dislocation after total hip arthroplasty. Causes and prevention. Clin Orthop 261:159–170PubMed
15.
go back to reference Mian SW, Truchly G, Pflum FA (1992) Computed tomography measurement of acetabular cup anteversion and retroversion in total hip arthroplasty. Clin Orthop 276:206–209PubMed Mian SW, Truchly G, Pflum FA (1992) Computed tomography measurement of acetabular cup anteversion and retroversion in total hip arthroplasty. Clin Orthop 276:206–209PubMed
16.
go back to reference Morrey BF(1992) Instability after total hip arthroplasty. Orthop Clin North Am. 23:237–248 Morrey BF(1992) Instability after total hip arthroplasty. Orthop Clin North Am. 23:237–248
17.
go back to reference Müller ME (1974)Total Hip Prosthesis. Clin Orthop 72:46–68 Müller ME (1974)Total Hip Prosthesis. Clin Orthop 72:46–68
18.
go back to reference Murray DW (1993) The definition and measurement of acetabular orientation. J Bone Joint Surg [Br] 75:228–232 Murray DW (1993) The definition and measurement of acetabular orientation. J Bone Joint Surg [Br] 75:228–232
19.
go back to reference Pierchon F, Pasquier G, Cotten A, Fontaine C, Clarisse J, and Duquennoy A (1994) Causes of dislocation of total hip arthroplasty. CT study of component alignment. J Bone Joint Surg [Br] 76:45–48 Pierchon F, Pasquier G, Cotten A, Fontaine C, Clarisse J, and Duquennoy A (1994) Causes of dislocation of total hip arthroplasty. CT study of component alignment. J Bone Joint Surg [Br] 76:45–48
20.
go back to reference Tannast M (2000) The measurement of anteversion and inclination with respect to the pelvic frontal plane. M.D.Thesis, University of Bern Tannast M (2000) The measurement of anteversion and inclination with respect to the pelvic frontal plane. M.D.Thesis, University of Bern
21.
go back to reference Yuan L, Shih C (1999) Dislocation after total hip arthroplasty. Arch Orthop Trauma Surg. 119:263–266 Yuan L, Shih C (1999) Dislocation after total hip arthroplasty. Arch Orthop Trauma Surg. 119:263–266
Metadata
Title
The accuracy of free-hand cup positioning - a CT based measurement of cup placement in 105 total hip arthroplasties
Authors
G. Saxler
A. Marx
D. Vandevelde
U. Langlotz
M. Tannast
M. Wiese
U. Michaelis
G. Kemper
P. A. Grützner
R. Steffen
M. von Knoch
T. Holland-Letz
K. Bernsmann
Publication date
01-08-2004
Publisher
Springer-Verlag
Published in
International Orthopaedics / Issue 4/2004
Print ISSN: 0341-2695
Electronic ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-004-0542-5

Other articles of this Issue 4/2004

International Orthopaedics 4/2004 Go to the issue