Abstract

Background

Total hip arthroplasty (THA) has been associated with high survival rates, but debate remains concerning the best fixation mode of THA.

Questions/purposes

We conducted a randomized controlled trial (RCT) with 250 patients with a mean age of 64 years between October 1987 and January 1992 to compare the results of cementless and cemented fixation.

Patients and Methods

Patients were evaluated for revision of either of the components. One hundred twenty-seven patients had died (51%) and 12 (4.8%) were lost to followup. The minimum 17-year followup data (mean, 20 years; range, 17–21 years) for 52 patients of the cementless group and 41 patients of the cemented group were available for evaluation.

Results

Kaplan-Meier survivorship analysis at 20 years revealed lower survival rates of cemented compared with cementless THA. The cementless tapered stem was associated with a survivorship of 99%. Age younger than 65 years and male gender were predictors of revision surgery.

Conclusions

The efficacy of future RCTs can be enhanced by randomizing patients in specific patient cohorts stratified to age and gender in multicenter RCTs. Including only younger patients might improve the efficacy of a future RCT with smaller sample sizes being required. A minimum 10-year followup should be anticipated, but this can be expected to be longer if the difference in level of quality between the compared implants is smaller.

Level of Evidence

Level I, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
Appendix
Available only for authorised users
Literature
1.
go back to reference Aldinger PR, Jung AW, Breusch SJ, Ewerbeck V, Parsch D. Survival of the cementless Spotorno stem in the second decade. Clin Orthop Relat Res. 2009;467:2297–2304.CrossRefPubMed Aldinger PR, Jung AW, Breusch SJ, Ewerbeck V, Parsch D. Survival of the cementless Spotorno stem in the second decade. Clin Orthop Relat Res. 2009;467:2297–2304.CrossRefPubMed
2.
go back to reference Aldinger PR, Jung AW, Pritsch M, Breusch S, Thomsen M, Ewerbeck V, Parsch D. Uncemented grit-blasted straight tapered titanium stems in patients younger than fifty-five years of age: fifteen to twenty-year results. J Bone Joint Surg Am. 2009;91:1432–1439.CrossRefPubMed Aldinger PR, Jung AW, Pritsch M, Breusch S, Thomsen M, Ewerbeck V, Parsch D. Uncemented grit-blasted straight tapered titanium stems in patients younger than fifty-five years of age: fifteen to twenty-year results. J Bone Joint Surg Am. 2009;91:1432–1439.CrossRefPubMed
4.
go back to reference Belmont PJ Jr, Powers CC, Beykirch SE, Hopper RH Jr, Engh CA Jr, Engh CA. Results of the anatomic medullary locking total hip arthroplasty at a minimum of twenty years: a concise follow-up of previous reports. J Bone Joint Surg Am. 2008;90:1524–1530.CrossRefPubMed Belmont PJ Jr, Powers CC, Beykirch SE, Hopper RH Jr, Engh CA Jr, Engh CA. Results of the anatomic medullary locking total hip arthroplasty at a minimum of twenty years: a concise follow-up of previous reports. J Bone Joint Surg Am. 2008;90:1524–1530.CrossRefPubMed
5.
go back to reference Berry DJ, Harmsen WS, Cabanela ME, Morrey BF. Twenty-five-year survivorship of two thousand consecutive primary Charnley total hip replacements: factors affecting survivorship of acetabular and femoral components. J Bone Joint Surg Am. 2002;84:171–177.PubMed Berry DJ, Harmsen WS, Cabanela ME, Morrey BF. Twenty-five-year survivorship of two thousand consecutive primary Charnley total hip replacements: factors affecting survivorship of acetabular and femoral components. J Bone Joint Surg Am. 2002;84:171–177.PubMed
6.
go back to reference Biomet Inc. Product Information Manual, Mallory-Head Total Hip Arthroplasty. Warsaw, IN: Biomet Inc; 1990. Biomet Inc. Product Information Manual, Mallory-Head Total Hip Arthroplasty. Warsaw, IN: Biomet Inc; 1990.
7.
go back to reference Bourne RB, Rorabeck CH, Patterson JJ, Guerin J. Tapered titanium cementless total hip replacements: a 10- to 13-year followup study. Clin Orthop Relat Res. 2001;393:112–120.CrossRefPubMed Bourne RB, Rorabeck CH, Patterson JJ, Guerin J. Tapered titanium cementless total hip replacements: a 10- to 13-year followup study. Clin Orthop Relat Res. 2001;393:112–120.CrossRefPubMed
8.
go back to reference Buckwalter AE, Callaghan JJ, Liu SS, Pedersen DR, Goetz DD, Sullivan PM, Leinen JA, Johnston RC. Results of Charnley total hip arthroplasty with use of improved femoral cementing techniques: a concise follow-up, at a minimum of twenty-five years, of a previous report. J Bone Joint Surg Am. 2006;88:1481–1485.CrossRefPubMed Buckwalter AE, Callaghan JJ, Liu SS, Pedersen DR, Goetz DD, Sullivan PM, Leinen JA, Johnston RC. Results of Charnley total hip arthroplasty with use of improved femoral cementing techniques: a concise follow-up, at a minimum of twenty-five years, of a previous report. J Bone Joint Surg Am. 2006;88:1481–1485.CrossRefPubMed
9.
go back to reference Callaghan JJ, Dysart SH, Savory CG. The uncemented porous-coated anatomic total hip prosthesis: two-year results of a prospective consecutive series. J Bone Joint Surg Am. 1988;70:337–346.PubMed Callaghan JJ, Dysart SH, Savory CG. The uncemented porous-coated anatomic total hip prosthesis: two-year results of a prospective consecutive series. J Bone Joint Surg Am. 1988;70:337–346.PubMed
10.
go back to reference Callaghan JJ, Liu SS, Firestone DE, Yehyawi TM, Goetz DD, Sullivan J, Vittetoe DA, O’Rourke MR, Johnston RC. Total hip arthroplasty with cement and use of a collared matte-finish femoral component: nineteen to twenty-year follow-up. J Bone Joint Surg Am. 2008;90:299–306.CrossRefPubMed Callaghan JJ, Liu SS, Firestone DE, Yehyawi TM, Goetz DD, Sullivan J, Vittetoe DA, O’Rourke MR, Johnston RC. Total hip arthroplasty with cement and use of a collared matte-finish femoral component: nineteen to twenty-year follow-up. J Bone Joint Surg Am. 2008;90:299–306.CrossRefPubMed
11.
go back to reference Campbell AC, Rorabeck CH, Bourne RB, Chess D, Nott L. Thigh pain after cementless hip arthroplasty: annoyance or ill omen. J Bone Joint Surg Br. 1992;74:63–66.PubMed Campbell AC, Rorabeck CH, Bourne RB, Chess D, Nott L. Thigh pain after cementless hip arthroplasty: annoyance or ill omen. J Bone Joint Surg Br. 1992;74:63–66.PubMed
12.
go back to reference Collis DK. Cemented total hip replacement in patients who are less than fifty years old. J Bone Joint Surg Am. 1984;66:353–359.PubMed Collis DK. Cemented total hip replacement in patients who are less than fifty years old. J Bone Joint Surg Am. 1984;66:353–359.PubMed
13.
go back to reference DeLee JB, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res. 1976;121:20–32.PubMed DeLee JB, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res. 1976;121:20–32.PubMed
14.
go back to reference Devane PA, Horne JG. Assessment of polyethylene wear in total hip replacement. Clin Orthop Relat Res. 1999;369:59–72.CrossRefPubMed Devane PA, Horne JG. Assessment of polyethylene wear in total hip replacement. Clin Orthop Relat Res. 1999;369:59–72.CrossRefPubMed
15.
go back to reference Dodge BM, Fitzrandolph R, Collins DN. Noncemented porous-coated anatomic total hip arthroplasty. Clin Orthop Relat Res. 1991;269:16–24.PubMed Dodge BM, Fitzrandolph R, Collins DN. Noncemented porous-coated anatomic total hip arthroplasty. Clin Orthop Relat Res. 1991;269:16–24.PubMed
16.
go back to reference Dolhain P, Tsigaras H, Bourne RB, Rorabeck CH, Mac Donald SJ, Mc Calden R. The effectiveness of dual offset stems in restoring offset during total hip replacement. Acta Orthop Belg. 2002;68:490–499.PubMed Dolhain P, Tsigaras H, Bourne RB, Rorabeck CH, Mac Donald SJ, Mc Calden R. The effectiveness of dual offset stems in restoring offset during total hip replacement. Acta Orthop Belg. 2002;68:490–499.PubMed
17.
go back to reference Dorr LD, Takei GK, Conaty JP. Total hip arthroplasties in patients less than forty-five years old. J Bone Joint Surg Am. 1983;65:474–479.PubMed Dorr LD, Takei GK, Conaty JP. Total hip arthroplasties in patients less than forty-five years old. J Bone Joint Surg Am. 1983;65:474–479.PubMed
18.
go back to reference Engh CA, Bobyn JD, Glassman AH. Porous-coated hip replacement: the factors governing bone ingrowth, stress shielding, and clinical results. J Bone Joint Surg Br. 1987;69:45–55.PubMed Engh CA, Bobyn JD, Glassman AH. Porous-coated hip replacement: the factors governing bone ingrowth, stress shielding, and clinical results. J Bone Joint Surg Br. 1987;69:45–55.PubMed
19.
go back to reference Engh CA, McGovern TF, Engh CA Jr, Macalino GE. Clinical experience with the anatomic medullary locking (AML) prosthesis for total hip replacement. In: Morrey BF, ed. Biological, Material, and Mechanical Considerations of Joint Replacement. New York, NY: Raven Press; 1993:167–184. Engh CA, McGovern TF, Engh CA Jr, Macalino GE. Clinical experience with the anatomic medullary locking (AML) prosthesis for total hip replacement. In: Morrey BF, ed. Biological, Material, and Mechanical Considerations of Joint Replacement. New York, NY: Raven Press; 1993:167–184.
20.
go back to reference Firestone DE, Callaghan JJ, Liu SS, Goetz DD, Sullivan PM, Vittetoe DA, Johnston RC. Total hip arthroplasty with a cemented, polished, collared femoral stem and a cementless acetabular component: a follow-up study at a minimum of ten years. J Bone Joint Surg Am. 2007;89:126–132.CrossRefPubMed Firestone DE, Callaghan JJ, Liu SS, Goetz DD, Sullivan PM, Vittetoe DA, Johnston RC. Total hip arthroplasty with a cemented, polished, collared femoral stem and a cementless acetabular component: a follow-up study at a minimum of ten years. J Bone Joint Surg Am. 2007;89:126–132.CrossRefPubMed
21.
go back to reference Garcia-Cimbrelo E, Cruz-Pardos A, Madero R, Ortega-Andreu M. Total hip arthroplasty with use of the cementless Zweymuller Alloclassic system: a ten to thirteen-year follow-up study. J Bone Joint Surg Am. 2003;85:296–303.PubMed Garcia-Cimbrelo E, Cruz-Pardos A, Madero R, Ortega-Andreu M. Total hip arthroplasty with use of the cementless Zweymuller Alloclassic system: a ten to thirteen-year follow-up study. J Bone Joint Surg Am. 2003;85:296–303.PubMed
22.
go back to reference Grubl A, Chiari C, Gruber M, Kaider A, Gottsauner-Wolf F. Cementless total hip arthroplasty with a tapered, rectangular titanium stem and a threaded cup: a minimum ten-year follow-up. J Bone Joint Surg Am. 2002;84:425–431.PubMed Grubl A, Chiari C, Gruber M, Kaider A, Gottsauner-Wolf F. Cementless total hip arthroplasty with a tapered, rectangular titanium stem and a threaded cup: a minimum ten-year follow-up. J Bone Joint Surg Am. 2002;84:425–431.PubMed
23.
go back to reference Gruen TA, McNeice GM, Amstutz HC. “Modes of failure” of cemented stem type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res. 1979;141:17–27. PubMed Gruen TA, McNeice GM, Amstutz HC. “Modes of failure” of cemented stem type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res. 1979;141:17–27. PubMed
24.
go back to reference Hallan G, Lie SA, Furnes O, Engesaeter LB, Vollset SE, Havelin LI. Medium- and long-term performance of 11516 uncemented primary femoral stems from the Norwegian arthroplasty register. J Bone Joint Surg Br. 2007;89:1574–1580.CrossRefPubMed Hallan G, Lie SA, Furnes O, Engesaeter LB, Vollset SE, Havelin LI. Medium- and long-term performance of 11516 uncemented primary femoral stems from the Norwegian arthroplasty register. J Bone Joint Surg Br. 2007;89:1574–1580.CrossRefPubMed
25.
go back to reference Harris WH, McCarthy JC Jr, O’Neill DA. Femoral component loosening using contemporary techniques of femoral cement fixation. J Bone Joint Surg Am. 1982;64:1063–1067.PubMed Harris WH, McCarthy JC Jr, O’Neill DA. Femoral component loosening using contemporary techniques of femoral cement fixation. J Bone Joint Surg Am. 1982;64:1063–1067.PubMed
26.
go back to reference Harris WH, McGann WA. Loosening of the femoral component after use of the medullary-plug cementing technique: follow-up note with a minimum five-year follow-up. J Bone Joint Surg Am. 1986;68:1064–1066.PubMed Harris WH, McGann WA. Loosening of the femoral component after use of the medullary-plug cementing technique: follow-up note with a minimum five-year follow-up. J Bone Joint Surg Am. 1986;68:1064–1066.PubMed
27.
go back to reference Hooper GJ, Rothwell AG, Stringer M, Frampton C. Revision following cemented and uncemented primary total hip replacement: a seven-year analysis from the New Zealand Joint Registry. J Bone Joint Surg Br. 2009;91:451–458.CrossRefPubMed Hooper GJ, Rothwell AG, Stringer M, Frampton C. Revision following cemented and uncemented primary total hip replacement: a seven-year analysis from the New Zealand Joint Registry. J Bone Joint Surg Br. 2009;91:451–458.CrossRefPubMed
28.
go back to reference Hoppe DJ, Schemitsch EH, Morshed S, Tornetta P III, Bhandari M. Hierarchy of evidence: where observational studies fit in and why we need them. J Bone Joint Surg Am. 2009;91(suppl 3):2–9.CrossRefPubMed Hoppe DJ, Schemitsch EH, Morshed S, Tornetta P III, Bhandari M. Hierarchy of evidence: where observational studies fit in and why we need them. J Bone Joint Surg Am. 2009;91(suppl 3):2–9.CrossRefPubMed
29.
go back to reference Hozack WJ, Rothman RH, Eng K, Mesa J. Primary cementless hip arthroplasty with a titanium plasma sprayed prosthesis. Clin Orthop Relat Res. 1996;333:217–225.CrossRefPubMed Hozack WJ, Rothman RH, Eng K, Mesa J. Primary cementless hip arthroplasty with a titanium plasma sprayed prosthesis. Clin Orthop Relat Res. 1996;333:217–225.CrossRefPubMed
30.
go back to reference Johnsen SP, Sørensen HT, Lucht U, Søballe K, Overgaard S, Pedersen AB. Patient-related predictors of implant failure after primary total hip replacement in the initial, short- and long-terms: a nationwide Danish follow-up study including 36,984 patients. J Bone Joint Surg Br. 2006;88:1303–1308.CrossRefPubMed Johnsen SP, Sørensen HT, Lucht U, Søballe K, Overgaard S, Pedersen AB. Patient-related predictors of implant failure after primary total hip replacement in the initial, short- and long-terms: a nationwide Danish follow-up study including 36,984 patients. J Bone Joint Surg Br. 2006;88:1303–1308.CrossRefPubMed
31.
go back to reference Johnston RC, Fitzgerald RH Jr, Harris WH, Poss R, Muller ME, Sledge CB. Clinical and radiographic evaluation of total hip replacement: a standard system of terminology for reporting results. J Bone Joint Surg Am. 1990;72:161–168.PubMed Johnston RC, Fitzgerald RH Jr, Harris WH, Poss R, Muller ME, Sledge CB. Clinical and radiographic evaluation of total hip replacement: a standard system of terminology for reporting results. J Bone Joint Surg Am. 1990;72:161–168.PubMed
32.
go back to reference Kim YH, Kim JS, Yoon SH. Long-term survivorship of the Charnley Elite Plus femoral component in young patients. J Bone Joint Surg Br. 2007;89:449–454.CrossRefPubMed Kim YH, Kim JS, Yoon SH. Long-term survivorship of the Charnley Elite Plus femoral component in young patients. J Bone Joint Surg Br. 2007;89:449–454.CrossRefPubMed
33.
go back to reference Klaassen M, Martinez-Villalobos M, Pietrzak WS, Mangino GP, Guzman DC. Midterm survivorship of a press-fit, plasma-sprayed, tri-spike acetabular component. J Arthroplasty. 2009;24:391–399.CrossRefPubMed Klaassen M, Martinez-Villalobos M, Pietrzak WS, Mangino GP, Guzman DC. Midterm survivorship of a press-fit, plasma-sprayed, tri-spike acetabular component. J Arthroplasty. 2009;24:391–399.CrossRefPubMed
34.
go back to reference Klapach AS, Callaghan JJ, Goetz DDm Olejniczak JP, Johnston RC. Charnley total hip arthroplasty with use of improved cementing techniques: a minimum twenty-year follow-up study. J Bone Joint Surg Am. 2001;83:1840–1848.PubMed Klapach AS, Callaghan JJ, Goetz DDm Olejniczak JP, Johnston RC. Charnley total hip arthroplasty with use of improved cementing techniques: a minimum twenty-year follow-up study. J Bone Joint Surg Am. 2001;83:1840–1848.PubMed
35.
go back to reference Laupacis A, Bourne R, Rorabeck C, Feeny D, Tugwell P, Wong C. Comparison of total hip arthroplasty with and without cement: a randomized trial. J Bone Joint Surg Am. 2002;84:1823–1828.PubMed Laupacis A, Bourne R, Rorabeck C, Feeny D, Tugwell P, Wong C. Comparison of total hip arthroplasty with and without cement: a randomized trial. J Bone Joint Surg Am. 2002;84:1823–1828.PubMed
36.
go back to reference Loudon JR, Charnley J. Subsidence of the femoral prosthesis in total hip replacement in relation to the design of the stem. J Bone Joint Surg Br. 1980;62:450–453.PubMed Loudon JR, Charnley J. Subsidence of the femoral prosthesis in total hip replacement in relation to the design of the stem. J Bone Joint Surg Br. 1980;62:450–453.PubMed
37.
go back to reference Mäkelä K, Eskelinen A, Pulkkinen P, Paavolainen P, Remes V. Cemented total hip replacement for primary osteoarthritis in patients aged 55 years or older: results of the 12 most common cemented implants followed for 25 years in the Finnish Arthroplasty Register. J Bone Joint Surg Br. 2008;90:1562–1569.CrossRefPubMed Mäkelä K, Eskelinen A, Pulkkinen P, Paavolainen P, Remes V. Cemented total hip replacement for primary osteoarthritis in patients aged 55 years or older: results of the 12 most common cemented implants followed for 25 years in the Finnish Arthroplasty Register. J Bone Joint Surg Br. 2008;90:1562–1569.CrossRefPubMed
38.
go back to reference Mâkelä KT, Eskelinen A, Pulkkinen P, Paavolainen P, Remes V. Total hip arthroplasty for primary osteoarthritis in patients fifty-five years of age or older: an analysis of the Finnish arthroplasty registry. J Bone Joint Surg Am. 2008;90:2160–2170.CrossRefPubMed Mâkelä KT, Eskelinen A, Pulkkinen P, Paavolainen P, Remes V. Total hip arthroplasty for primary osteoarthritis in patients fifty-five years of age or older: an analysis of the Finnish arthroplasty registry. J Bone Joint Surg Am. 2008;90:2160–2170.CrossRefPubMed
39.
go back to reference Mallory TH, Lombardi AV Jr, Leith JR, Fujita H, Hartman JF, Capps SG, Kefauver CA, Adams JB, Vorys GC. Minimal 10-year results of a tapered cementless femoral component in total hip arthroplasty. J Arthroplasty. 2001;16(8 suppl 1):49–54. Mallory TH, Lombardi AV Jr, Leith JR, Fujita H, Hartman JF, Capps SG, Kefauver CA, Adams JB, Vorys GC. Minimal 10-year results of a tapered cementless femoral component in total hip arthroplasty. J Arthroplasty. 2001;16(8 suppl 1):49–54.
40.
go back to reference Massin P, Schmidt L, Engh CA. Evaluation of cementless acetabular component migration: an experimental study. J Arthroplasty. 1989;4:245–251.CrossRefPubMed Massin P, Schmidt L, Engh CA. Evaluation of cementless acetabular component migration: an experimental study. J Arthroplasty. 1989;4:245–251.CrossRefPubMed
41.
go back to reference McCalden RW, MacDonald SJ, Rorabeck CH, Bourne RB, Chess DG, Charron KD. Wear rate of highly cross-linked polyethylene in total hip arthroplasty: a randomized controlled trial. J Bone Joint Surg Am. 2009;91:773–782.CrossRefPubMed McCalden RW, MacDonald SJ, Rorabeck CH, Bourne RB, Chess DG, Charron KD. Wear rate of highly cross-linked polyethylene in total hip arthroplasty: a randomized controlled trial. J Bone Joint Surg Am. 2009;91:773–782.CrossRefPubMed
42.
go back to reference McGrory BJ, Morrey BF, Cahalan TD, An KN, Cabanela ME. Effect of femoral offset on range of motion and abductor muscle strength after total hip arthroplasty. J Bone Joint Surg Br. 1995;77:865–869.PubMed McGrory BJ, Morrey BF, Cahalan TD, An KN, Cabanela ME. Effect of femoral offset on range of motion and abductor muscle strength after total hip arthroplasty. J Bone Joint Surg Br. 1995;77:865–869.PubMed
43.
go back to reference McLaughlin JR, Lee KR. Total hip arthroplasty with an uncemented tapered femoral component. J Bone Joint Surg Am. 2008;90:1290–1296.CrossRefPubMed McLaughlin JR, Lee KR. Total hip arthroplasty with an uncemented tapered femoral component. J Bone Joint Surg Am. 2008;90:1290–1296.CrossRefPubMed
44.
go back to reference McNulty DE, Liao YS, Haas BD. The influence of sterilization method on wear performance of the low contact stress total knee system. Orthopedics. 2002;25(2 suppl 2):s243–s246. McNulty DE, Liao YS, Haas BD. The influence of sterilization method on wear performance of the low contact stress total knee system. Orthopedics. 2002;25(2 suppl 2):s243–s246.
45.
go back to reference Mulliken BD, Bourne RB, Rorabeck CH, Nayak N. A tapered titanium femoral stem inserted without cement in a total hip arthroplasty: radiographic evaluation and stability. J Bone Joint Surg Am. 1996;78:1214–1225.PubMed Mulliken BD, Bourne RB, Rorabeck CH, Nayak N. A tapered titanium femoral stem inserted without cement in a total hip arthroplasty: radiographic evaluation and stability. J Bone Joint Surg Am. 1996;78:1214–1225.PubMed
46.
go back to reference Mulliken BD, Rorabeck CH, Bourne RB. Uncemented revision total hip arthroplasty: a 4-to-6-year review. Clin Orthop Relat Res. 1996;325:156–162.CrossRefPubMed Mulliken BD, Rorabeck CH, Bourne RB. Uncemented revision total hip arthroplasty: a 4-to-6-year review. Clin Orthop Relat Res. 1996;325:156–162.CrossRefPubMed
48.
go back to reference Parvizi J, Sharkey PF, Hozack WJ, Orzoco F, Bissett GA, Rothman RH. Prospective matched-pair analysis of hydroxyapatite-coated and uncoated femoral stems in total hip arthroplasty: a concise follow-up of a previous report. J Bone Joint Surg Am. 2004;86:783–786.CrossRefPubMed Parvizi J, Sharkey PF, Hozack WJ, Orzoco F, Bissett GA, Rothman RH. Prospective matched-pair analysis of hydroxyapatite-coated and uncoated femoral stems in total hip arthroplasty: a concise follow-up of a previous report. J Bone Joint Surg Am. 2004;86:783–786.CrossRefPubMed
49.
go back to reference Purtill JJ, Rothman RH, Hozack WJ, Sharkey PF. Total hip arthroplasty using two different cementless tapered stems. Clin Orthop Relat Res. 2001;393:121–127.CrossRefPubMed Purtill JJ, Rothman RH, Hozack WJ, Sharkey PF. Total hip arthroplasty using two different cementless tapered stems. Clin Orthop Relat Res. 2001;393:121–127.CrossRefPubMed
50.
go back to reference Ranawat CS, Atkinson RE, Salvati EA, Wilson PD Jr. Conventional total hip arthroplasty for degenerative joint disease in patients between the ages of forty and sixty years. J Bone Joint Surg Am. 1984;66:745–752.PubMed Ranawat CS, Atkinson RE, Salvati EA, Wilson PD Jr. Conventional total hip arthroplasty for degenerative joint disease in patients between the ages of forty and sixty years. J Bone Joint Surg Am. 1984;66:745–752.PubMed
51.
go back to reference Ritter MA, Keating EM, Faris PM. A porous polyethylene-coated femoral component of a total hip arthroplasty. J Arthroplasty. 1990;5:83–88.CrossRefPubMed Ritter MA, Keating EM, Faris PM. A porous polyethylene-coated femoral component of a total hip arthroplasty. J Arthroplasty. 1990;5:83–88.CrossRefPubMed
52.
go back to reference Rorabeck CH, Bourne RB, Laupacis A, Feeny D, Wong C, Tugwell P, Leslie K, Bullas R. A double-blind study of 250 cases comparing cemented with cementless total hip arthroplasty: cost-effectiveness and its impact on health-related quality of life. Clin Orthop Relat Res. 1994;298:156–164.PubMed Rorabeck CH, Bourne RB, Laupacis A, Feeny D, Wong C, Tugwell P, Leslie K, Bullas R. A double-blind study of 250 cases comparing cemented with cementless total hip arthroplasty: cost-effectiveness and its impact on health-related quality of life. Clin Orthop Relat Res. 1994;298:156–164.PubMed
53.
go back to reference Rothman RH, Cohn JC. Cemented versus cementless total hip arthroplasty: a critical review. Clin Orthop Relat Res. 1990;254:153–169.PubMed Rothman RH, Cohn JC. Cemented versus cementless total hip arthroplasty: a critical review. Clin Orthop Relat Res. 1990;254:153–169.PubMed
54.
go back to reference Sakalkale DP, Sharkey PF, Eng K, Hozack WJ, Rothman RH. Effect of femoral component offset on polyethylene wear in total hip arthroplasty. Clin Orthop Relat Res. 2001;388:125–134.CrossRefPubMed Sakalkale DP, Sharkey PF, Eng K, Hozack WJ, Rothman RH. Effect of femoral component offset on polyethylene wear in total hip arthroplasty. Clin Orthop Relat Res. 2001;388:125–134.CrossRefPubMed
55.
go back to reference Schmalzried TP, Shepherd EF, Dorey FJ, Jackson WO, dela Rosa M, Fa’vae F, McKellop HA, McClung CD, Martell J, Moreland JR, Amstutz HC. The John Charnley Award: wear is a function of use, not time. Clin Orthop Relat Res. 2000;381:36–46.CrossRefPubMed Schmalzried TP, Shepherd EF, Dorey FJ, Jackson WO, dela Rosa M, Fa’vae F, McKellop HA, McClung CD, Martell J, Moreland JR, Amstutz HC. The John Charnley Award: wear is a function of use, not time. Clin Orthop Relat Res. 2000;381:36–46.CrossRefPubMed
56.
go back to reference Schramm M, Keck F, Hohmann D, Pitto RP. Total hip arthroplasty using an uncemented femoral component with taper design: outcome at 10-year follow-up. Arch Orthop Trauma Surg. 2000;120:407–412.CrossRefPubMed Schramm M, Keck F, Hohmann D, Pitto RP. Total hip arthroplasty using an uncemented femoral component with taper design: outcome at 10-year follow-up. Arch Orthop Trauma Surg. 2000;120:407–412.CrossRefPubMed
57.
go back to reference Shen FW, McKellop HA. Interaction of oxidation and crosslinking in gamma-irradiated ultrahigh molecular-weight polyethylene. J Biomed Mater Res. 2002;61:430–439.CrossRefPubMed Shen FW, McKellop HA. Interaction of oxidation and crosslinking in gamma-irradiated ultrahigh molecular-weight polyethylene. J Biomed Mater Res. 2002;61:430–439.CrossRefPubMed
58.
go back to reference Skutek M, Bourne RB, Rorabeck CH, Burns A, Kearns S, Krishna G. The twenty to twenty-five-year outcomes of the Harris design-2 matte-finished cemented total hip replacement: a concise follow-up of a previous report. J Bone Joint Surg Am. 2007;89:814–818.CrossRefPubMed Skutek M, Bourne RB, Rorabeck CH, Burns A, Kearns S, Krishna G. The twenty to twenty-five-year outcomes of the Harris design-2 matte-finished cemented total hip replacement: a concise follow-up of a previous report. J Bone Joint Surg Am. 2007;89:814–818.CrossRefPubMed
59.
go back to reference Spak RT, Stuchin SA. Cementless porous-coated sockets without holes implanted with pure press-fit technique: average 6-year follow-up. J Arthroplasty. 2005;20:4–10.CrossRef Spak RT, Stuchin SA. Cementless porous-coated sockets without holes implanted with pure press-fit technique: average 6-year follow-up. J Arthroplasty. 2005;20:4–10.CrossRef
60.
go back to reference Stauffer RN. Ten-year follow-up study of total hip replacement. J Bone Joint Surg Am. 1982;64:983–990.PubMed Stauffer RN. Ten-year follow-up study of total hip replacement. J Bone Joint Surg Am. 1982;64:983–990.PubMed
61.
go back to reference Suckel A, Geiger F, Kinzl L, Wulker N, Garbrecht M. Long-term results for the uncemented Zweymuller/Alloclassic hip endoprosthesis: a 15-year minimum follow-up of 320 hip operations. J Arthroplasty. 2009;24:846–853.CrossRefPubMed Suckel A, Geiger F, Kinzl L, Wulker N, Garbrecht M. Long-term results for the uncemented Zweymuller/Alloclassic hip endoprosthesis: a 15-year minimum follow-up of 320 hip operations. J Arthroplasty. 2009;24:846–853.CrossRefPubMed
62.
go back to reference Sutherland CJ, Wilde AH, Borden LS, Marks KE. A ten-year follow-up of one hundred consecutive Muller curved-stem total hip-replacement arthroplasties. J Bone Joint Surg Am. 1982;64:970–982.PubMed Sutherland CJ, Wilde AH, Borden LS, Marks KE. A ten-year follow-up of one hundred consecutive Muller curved-stem total hip-replacement arthroplasties. J Bone Joint Surg Am. 1982;64:970–982.PubMed
64.
go back to reference Teloken MA, Bissett G, Hozack WJ, Sharkey PF, Rothman RH. Ten to fifteen-year follow-up after total hip arthroplasty with a tapered cobalt-chromium femoral component (tri-lock) inserted without cement. J Bone Joint Surg Am. 2002;84:2140–2144.PubMed Teloken MA, Bissett G, Hozack WJ, Sharkey PF, Rothman RH. Ten to fifteen-year follow-up after total hip arthroplasty with a tapered cobalt-chromium femoral component (tri-lock) inserted without cement. J Bone Joint Surg Am. 2002;84:2140–2144.PubMed
Metadata
Title
What Works Best, a Cemented or Cementless Primary Total Hip Arthroplasty?: Minimum 17-year Followup of a Randomized Controlled Trial
Authors
Kristoff Corten, MD
Robert B. Bourne, MD, FRCS(C)
Kory D. Charron, Dipl.MET
Keegan Au, MD, FRCS(C)
Cecil H. Rorabeck, MD, FRCS(C)
Publication date
01-01-2011
Publisher
Springer-Verlag
Published in
Clinical Orthopaedics and Related Research® / Issue 1/2011
Print ISSN: 0009-921X
Electronic ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-010-1459-5

Other articles of this Issue 1/2011

Clinical Orthopaedics and Related Research® 1/2011 Go to the issue

Symposium: Papers Presented at the Annual Meetings of the Knee Society

Management of Intraoperative Medial Collateral Ligament Injury During TKA

Symposium: Papers Presented at the Annual Meetings of the Knee Society

Hospital Economics of Primary Total Knee Arthroplasty at a Teaching Hospital

Symposium: Papers Presented at the Annual Meetings of the Knee Society

The Mark Coventry Award: Diagnosis of Early Postoperative TKA Infection Using Synovial Fluid Analysis

Symposium: Papers Presented at the Annual Meetings of the Knee Society

Liner Exchange and Bone Grafting: Rare Option to Treat Wear & Lysis of Stable TKAs