Skip to main content
Top
Published in: Clinical Orthopaedics and Related Research® 1/2009

01-01-2009 | Symposium: Papers Presented at the Hip Society Meetings 2008

Survivorship of 2000 Tapered Titanium Porous Plasma-sprayed Femoral Components

Authors: Adolph V. Lombardi Jr., MD, Keith R. Berend, MD, Thomas H. Mallory, MD, Michael D. Skeels, DO, Joanne B. Adams, BFA

Published in: Clinical Orthopaedics and Related Research® | Issue 1/2009

Login to get access

Abstract

Tapered titanium porous plasma-sprayed components have performed well in primary THA. To confirm the literature at longer followup we retrospectively reviewed all 1639 patients who underwent 2000 THAs in which a specific porous femoral component was used. One hundred fourteen patients (134 hips) were lost to followup leaving a cohort of 1525 patients (1866 THAs). The component is a tapered titanium plasma spray-coated design that remained relatively unchanged since its first implantation except for circumferential proximal porous coating added in 1986 and an offset option added in 1999. Minimum followup was 24 months (average, 119 months; range, 24 to 275 months). To date there have been 39 femoral revisions for an implant survival of 98%. Using the Kaplan-Meier method, cumulative survival with any stem revision as the end point was 98.6% at 5 years, 98.4% at 10 years, 97.1% at 15 years, and 95.5% at 20 years. Using aseptic revision for failure of ingrowth as the endpoint, stem survival was 99.1%. Kaplan-Meier cumulative survival with aseptic revision for failure of ingrowth as the endpoint was 99.4% at 5 years, 99.3% at 10, 15 and 20 years. Harris hip pain and total scores improved. This titanium, porous plasma spray-coated femoral component continues to demonstrate high long-term survival with a low rate of component revision for any reason or aseptic failure of ingrowth.
Level of Evidence: Level IV, therapeutic study (case series). See the Guidelines for Authors for a complete description of levels of evidence.
Literature
2.
go back to reference Berend KR, Lombardi AV Jr, Mallory TH, Chonko DJ, Dodds KL, Adams JB. Cerclage wires or cables for the management of intraoperative fracture associated with a cementless, tapered femoral prosthesis: results at 2 to 16 years. J Arthroplasty. 2004; 19(7 Suppl 2):17–21.PubMedCrossRef Berend KR, Lombardi AV Jr, Mallory TH, Chonko DJ, Dodds KL, Adams JB. Cerclage wires or cables for the management of intraoperative fracture associated with a cementless, tapered femoral prosthesis: results at 2 to 16 years. J Arthroplasty. 2004; 19(7 Suppl 2):17–21.PubMedCrossRef
3.
go back to reference Berend KR, Lombardi AV, Mallory TH, Dodds KL, Adams JB. Cementless double-tapered total hip arthroplasty in patients 75 years of age and older. J Arthroplasty. 2004;19:288–295.PubMedCrossRef Berend KR, Lombardi AV, Mallory TH, Dodds KL, Adams JB. Cementless double-tapered total hip arthroplasty in patients 75 years of age and older. J Arthroplasty. 2004;19:288–295.PubMedCrossRef
4.
go back to reference Berend KR, Mallory TH, Lombardi AV Jr, Dodds KL, Adams JB. Tapered cementless femoral stem: difficult to place in varus but performs well in those rare cases. Orthopedics. 2007;30:295–297.PubMed Berend KR, Mallory TH, Lombardi AV Jr, Dodds KL, Adams JB. Tapered cementless femoral stem: difficult to place in varus but performs well in those rare cases. Orthopedics. 2007;30:295–297.PubMed
5.
go back to reference Bobyn JD, Jacobs JJ, Tanzer M, Urban RM, Aribindi R, Sumner DR, Turner TM, Brooks CE. The susceptibility of smooth implant surfaces to periimplant fibrosis and migration of polyethylene wear debris. Clin Orthop Relat Res. 1995;311:21–39.PubMed Bobyn JD, Jacobs JJ, Tanzer M, Urban RM, Aribindi R, Sumner DR, Turner TM, Brooks CE. The susceptibility of smooth implant surfaces to periimplant fibrosis and migration of polyethylene wear debris. Clin Orthop Relat Res. 1995;311:21–39.PubMed
6.
go back to reference Bobyn JD, Tanzer M, Krygier JJ, Dujovne AR, Brooks CE. Concerns with modularity in total hip arthroplasty. Clin Orthop Relat Res. 1994;298:27–36.PubMed Bobyn JD, Tanzer M, Krygier JJ, Dujovne AR, Brooks CE. Concerns with modularity in total hip arthroplasty. Clin Orthop Relat Res. 1994;298:27–36.PubMed
7.
go back to reference Bourne RB, Rorabeck CH, Patterson JJ, Guerin J. The proximal porous coating alternative for primary total hip arthroplasty. Clin Orthop Relat Res. 2001;393:112–120.PubMedCrossRef Bourne RB, Rorabeck CH, Patterson JJ, Guerin J. The proximal porous coating alternative for primary total hip arthroplasty. Clin Orthop Relat Res. 2001;393:112–120.PubMedCrossRef
8.
go back to reference Callaghan JJ, Mallory TH. Optimal fixation for femoral components: cemented or cementless. J Arthroplasty. 1995;10:401–404.PubMedCrossRef Callaghan JJ, Mallory TH. Optimal fixation for femoral components: cemented or cementless. J Arthroplasty. 1995;10:401–404.PubMedCrossRef
9.
go back to reference Cameron HU, Keppler L, McTighe T. The role of modularity in primary total hip arthroplasty. J Arthroplasty. 2006;21(4 Suppl 1):89–92.PubMedCrossRef Cameron HU, Keppler L, McTighe T. The role of modularity in primary total hip arthroplasty. J Arthroplasty. 2006;21(4 Suppl 1):89–92.PubMedCrossRef
10.
go back to reference Christie MJ, DeBoer DK, Trick LW, Brothers JC, Jones RE, Vise GT, Gruen TA. Primary total hip arthroplasty with use of the modular S-ROM prosthesis. Four to seven-year clinical and radiographic results. J Bone Joint Surg Am. 1999;81:1707–716.PubMed Christie MJ, DeBoer DK, Trick LW, Brothers JC, Jones RE, Vise GT, Gruen TA. Primary total hip arthroplasty with use of the modular S-ROM prosthesis. Four to seven-year clinical and radiographic results. J Bone Joint Surg Am. 1999;81:1707–716.PubMed
11.
go back to reference DeLee JG, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res. 1976;121:20–32.PubMed DeLee JG, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res. 1976;121:20–32.PubMed
12.
go back to reference Dorr LD, Faugere MC, Mackel AM, Gruen TA, Bognar B, Malluche HH. Structural and cellular assessment of bone quality of proximal femur. Bone. 1993;14:231–242.PubMedCrossRef Dorr LD, Faugere MC, Mackel AM, Gruen TA, Bognar B, Malluche HH. Structural and cellular assessment of bone quality of proximal femur. Bone. 1993;14:231–242.PubMedCrossRef
13.
go back to reference Dowdy PA, Rorabeck CH, Bourne RB. Uncemented total hip arthroplasty in patients 50 years of age or younger. J Arthroplasty. 1997;12:853–862.PubMedCrossRef Dowdy PA, Rorabeck CH, Bourne RB. Uncemented total hip arthroplasty in patients 50 years of age or younger. J Arthroplasty. 1997;12:853–862.PubMedCrossRef
14.
go back to reference Ellison B, Berend KR, Lombardi AV Jr, Mallory TH. Tapered titanium porous plasma-sprayed femoral component in patients aged 40 years and younger. J Arthroplasty. 2006;21(6 Suppl 2):32–37.PubMedCrossRef Ellison B, Berend KR, Lombardi AV Jr, Mallory TH. Tapered titanium porous plasma-sprayed femoral component in patients aged 40 years and younger. J Arthroplasty. 2006;21(6 Suppl 2):32–37.PubMedCrossRef
15.
go back to reference Emerson RH Jr, Head WC, Emerson CB, Rosenfeldt W, Higgins LL. A comparison of cemented and cementless titanium femoral components used for primary total hip arthroplasty: a radiographic and survivorship study. J Arthroplasty. 2002;17:584–591.PubMedCrossRef Emerson RH Jr, Head WC, Emerson CB, Rosenfeldt W, Higgins LL. A comparison of cemented and cementless titanium femoral components used for primary total hip arthroplasty: a radiographic and survivorship study. J Arthroplasty. 2002;17:584–591.PubMedCrossRef
16.
go back to reference Emerson RH Jr, Head WC, Higgins LL. Clinical and radiographic analysis of the Mallory-Head femoral component in revision total hip arthroplasty. A minimum 8.8-year and average eleven-year follow-up study. J Bone Joint Surg Am. 2003;85:1921–1926.PubMed Emerson RH Jr, Head WC, Higgins LL. Clinical and radiographic analysis of the Mallory-Head femoral component in revision total hip arthroplasty. A minimum 8.8-year and average eleven-year follow-up study. J Bone Joint Surg Am. 2003;85:1921–1926.PubMed
17.
go back to reference Emerson RH Jr, Sanders SB, Head WC, Higgins L. Effect of circumferential plasma-spray porous coating on the rate of femoral osteolysis after total hip arthroplasty. J Bone Joint Surg Am. 1999;81:1291–1298.PubMed Emerson RH Jr, Sanders SB, Head WC, Higgins L. Effect of circumferential plasma-spray porous coating on the rate of femoral osteolysis after total hip arthroplasty. J Bone Joint Surg Am. 1999;81:1291–1298.PubMed
18.
go back to reference Engh CA, Hopper RH Jr. The odyssey of porous-coated fixation. J Arthroplasty. 2002;17(4 Suppl 1):102–107.PubMed Engh CA, Hopper RH Jr. The odyssey of porous-coated fixation. J Arthroplasty. 2002;17(4 Suppl 1):102–107.PubMed
19.
go back to reference Engh CA Jr, Claus AM, Hopper RH Jr, Engh CA. Long-term results using the anatomic medullary locking hip prosthesis. Clin Orthop Relat Res. 2001;393:137–146.PubMedCrossRef Engh CA Jr, Claus AM, Hopper RH Jr, Engh CA. Long-term results using the anatomic medullary locking hip prosthesis. Clin Orthop Relat Res. 2001;393:137–146.PubMedCrossRef
20.
go back to reference Eskelinen A, Remes V, Helenius I, Pulkkinen P, Nevalainen J, Paavolainen P. Uncemented total hip arthroplasty for primary osteoarthritis in young patients: a mid-to long-term follow-up study from the Finnish Arthroplasty Register. Acta Orthop. 2006;77:57–70.PubMedCrossRef Eskelinen A, Remes V, Helenius I, Pulkkinen P, Nevalainen J, Paavolainen P. Uncemented total hip arthroplasty for primary osteoarthritis in young patients: a mid-to long-term follow-up study from the Finnish Arthroplasty Register. Acta Orthop. 2006;77:57–70.PubMedCrossRef
21.
go back to reference Frndak PA, Mallory TH, Lombardi AV Jr: Translateral surgical approach to the hip: The abductor muscle “split”. Clin Orthop Relat Res. 1993;295:135–141.PubMed Frndak PA, Mallory TH, Lombardi AV Jr: Translateral surgical approach to the hip: The abductor muscle “split”. Clin Orthop Relat Res. 1993;295:135–141.PubMed
22.
go back to reference Gosens T, van Langelaan EJ, Tonino AJ. Cementless mallory-head HA-coated hip arthroplasty for osteoarthritis in hip dysplasia. J Arthroplasty. 2003;18:401–410.PubMedCrossRef Gosens T, van Langelaan EJ, Tonino AJ. Cementless mallory-head HA-coated hip arthroplasty for osteoarthritis in hip dysplasia. J Arthroplasty. 2003;18:401–410.PubMedCrossRef
23.
go back to reference Harris M, Dorr LD, Wan Z, Sirianni L, Boutary M. Total hip arthroplasty with the APR stem and cup. Follow-up of a previous report. J Arthroplasty. 2005;20:828–831. Harris M, Dorr LD, Wan Z, Sirianni L, Boutary M. Total hip arthroplasty with the APR stem and cup. Follow-up of a previous report. J Arthroplasty. 2005;20:828–831.
24.
go back to reference Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am. 1969;51:737–755.PubMed Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am. 1969;51:737–755.PubMed
25.
go back to reference Havelin LI, Engesaeter LB, Espehaug B, Furnes O, Lie SA, Vollset SE. The Norwegian arthroplasty register. 11 years and 73,000 arthroplasties. Acta Orthop Scand. 2000;71:337–353.PubMedCrossRef Havelin LI, Engesaeter LB, Espehaug B, Furnes O, Lie SA, Vollset SE. The Norwegian arthroplasty register. 11 years and 73,000 arthroplasties. Acta Orthop Scand. 2000;71:337–353.PubMedCrossRef
26.
go back to reference Head WC, Mallory TH, Emerson RH Jr. The proximal porous coating alternative for primary total hip arthroplasty. Orthopedics. 1999;22:813–815.PubMed Head WC, Mallory TH, Emerson RH Jr. The proximal porous coating alternative for primary total hip arthroplasty. Orthopedics. 1999;22:813–815.PubMed
27.
go back to reference Hozack WJ, Rothman RH, Eng K, Mesa J. Primary cementless hip arthroplasty with a titanium plasma sprayed prosthesis. Clin Orthop Relat Res. 1996;333:217–225.PubMedCrossRef Hozack WJ, Rothman RH, Eng K, Mesa J. Primary cementless hip arthroplasty with a titanium plasma sprayed prosthesis. Clin Orthop Relat Res. 1996;333:217–225.PubMedCrossRef
28.
go back to reference Joshi AB, Gill GS, Smith PL. Outcome in patients lost to follow-up. J Arthroplasty. 2003;18:149–153.PubMedCrossRef Joshi AB, Gill GS, Smith PL. Outcome in patients lost to follow-up. J Arthroplasty. 2003;18:149–153.PubMedCrossRef
29.
go back to reference Kaplan EL, Meier P. Nonparametric estimation from incomplete data. J Am Statistical Assoc 1958;53:457–481.CrossRef Kaplan EL, Meier P. Nonparametric estimation from incomplete data. J Am Statistical Assoc 1958;53:457–481.CrossRef
30.
go back to reference Keisu KS, Orozco F, McCallum JD 3rd, Bissett G, Hozack WJ, Sharkey PF, Rothman RH. Cementless femoral fixation in the rheumatoid patient undergoing total hip arthroplasty: minimum 5-year results. J Arthroplasty. 2001;16:415–421.PubMedCrossRef Keisu KS, Orozco F, McCallum JD 3rd, Bissett G, Hozack WJ, Sharkey PF, Rothman RH. Cementless femoral fixation in the rheumatoid patient undergoing total hip arthroplasty: minimum 5-year results. J Arthroplasty. 2001;16:415–421.PubMedCrossRef
31.
go back to reference Keisu KS, Orozco F, Sharkey PF, Hozack WJ, Rothman RH, McGuigan FX. Primary cementless total hip arthroplasty in octogenarians. Two to eleven-year follow-up. J Bone Joint Surg Am. 2001;83:359–363.PubMedCrossRef Keisu KS, Orozco F, Sharkey PF, Hozack WJ, Rothman RH, McGuigan FX. Primary cementless total hip arthroplasty in octogenarians. Two to eleven-year follow-up. J Bone Joint Surg Am. 2001;83:359–363.PubMedCrossRef
32.
go back to reference Khalily C, Lester DK. Results of a tapered cementless femoral stem implanted in varus. J Arthroplasty. 2002;17:463–466.PubMedCrossRef Khalily C, Lester DK. Results of a tapered cementless femoral stem implanted in varus. J Arthroplasty. 2002;17:463–466.PubMedCrossRef
33.
go back to reference Kim YH. Long-term results of the cementless porous-coated anatomic total hip prosthesis. J Bone Joint Surg Br. 2005;87:623–627.PubMedCrossRef Kim YH. Long-term results of the cementless porous-coated anatomic total hip prosthesis. J Bone Joint Surg Br. 2005;87:623–627.PubMedCrossRef
34.
go back to reference Kim YH, Kim JS, Cho SH. Primary total hip arthroplasty with a cementless porous-coated anatomic total hip prosthesis: 10- to 12-year results of prospective and consecutive series. J Arthroplasty. 1999;14:538–548.PubMedCrossRef Kim YH, Kim JS, Cho SH. Primary total hip arthroplasty with a cementless porous-coated anatomic total hip prosthesis: 10- to 12-year results of prospective and consecutive series. J Arthroplasty. 1999;14:538–548.PubMedCrossRef
35.
go back to reference Kim YH, Kim JS, Cho SH. Primary total hip arthroplasty with the AML total hip prosthesis. Clin Orthop Relat Res. 1999;360:147–158.PubMedCrossRef Kim YH, Kim JS, Cho SH. Primary total hip arthroplasty with the AML total hip prosthesis. Clin Orthop Relat Res. 1999;360:147–158.PubMedCrossRef
36.
go back to reference King PJ, Malin AS, Scott RD, Thornhill TS. The fate of patients not returning for follow-up five years after total knee arthroplasty. J Bone Joint Surg Am. 2004;86:897–901.PubMed King PJ, Malin AS, Scott RD, Thornhill TS. The fate of patients not returning for follow-up five years after total knee arthroplasty. J Bone Joint Surg Am. 2004;86:897–901.PubMed
37.
go back to reference Kyle RF, Crickard GE. Hip arthroplasty: management problems; periprosthetic fractures associated with total hip arthroplasty. Orthopedics. 1998;21:982–984.PubMed Kyle RF, Crickard GE. Hip arthroplasty: management problems; periprosthetic fractures associated with total hip arthroplasty. Orthopedics. 1998;21:982–984.PubMed
38.
go back to reference Little BS, Wixson RL, Stulberg SD. Total hip arthroplasty with the porous-coated anatomic hip prosthesis: results at 11 to 18 years. J Arthoplasty. 2006;21:338–343.CrossRef Little BS, Wixson RL, Stulberg SD. Total hip arthroplasty with the porous-coated anatomic hip prosthesis: results at 11 to 18 years. J Arthoplasty. 2006;21:338–343.CrossRef
39.
go back to reference Lombardi AV Jr, Berend KR, Mallory TH. Hydroxyapatite-coated titanium porous plasma spray tapered stem: Experience at 15–18 years. Clin Orthop Relat Res. 2006;453:81–85.PubMedCrossRef Lombardi AV Jr, Berend KR, Mallory TH. Hydroxyapatite-coated titanium porous plasma spray tapered stem: Experience at 15–18 years. Clin Orthop Relat Res. 2006;453:81–85.PubMedCrossRef
40.
go back to reference Lombardi AV Jr, Mallory TH, Fada RA, Adams JB. Stem modularity: rarely necessary in primary total hip arthroplasty. Orthopedics. 2002;25:1385–1387.PubMed Lombardi AV Jr, Mallory TH, Fada RA, Adams JB. Stem modularity: rarely necessary in primary total hip arthroplasty. Orthopedics. 2002;25:1385–1387.PubMed
41.
go back to reference Lombardi AV Jr, Mallory TH, Vaughn BK, Drouillard P: Aseptic loosening in total hip arthroplasty secondary to osteolysis induced by wear debris from titanium alloy modular femoral heads. J Bone Joint Surg Am. 1989;71:1337–1342.PubMed Lombardi AV Jr, Mallory TH, Vaughn BK, Drouillard P: Aseptic loosening in total hip arthroplasty secondary to osteolysis induced by wear debris from titanium alloy modular femoral heads. J Bone Joint Surg Am. 1989;71:1337–1342.PubMed
42.
go back to reference Malchau H, Herberts P, Eisler T, Garellick G, Söderman P. The Swedish Total Hip Replacement Register. J Bone Joint Surg Am. 2002;84(Suppl 2):2–20.PubMed Malchau H, Herberts P, Eisler T, Garellick G, Söderman P. The Swedish Total Hip Replacement Register. J Bone Joint Surg Am. 2002;84(Suppl 2):2–20.PubMed
43.
go back to reference Malik MHA, Gambhir AK, Bale L, Pradhan N, Porter ML. Primary total hip replacement: a comparison of a nationally agreed to best practice and current surgical technique as determined by the North West Regional Arthroplasty Register. Ann R Coll Surg Engl. 2004;86:113–118.PubMedCrossRef Malik MHA, Gambhir AK, Bale L, Pradhan N, Porter ML. Primary total hip replacement: a comparison of a nationally agreed to best practice and current surgical technique as determined by the North West Regional Arthroplasty Register. Ann R Coll Surg Engl. 2004;86:113–118.PubMedCrossRef
44.
go back to reference Mallory TH, Head WC, Lombardi AV Jr. Tapered design for the cementless total hip arthroplasty femoral component. Clin Orthop Relat Res. 1997;344:172–178.PubMedCrossRef Mallory TH, Head WC, Lombardi AV Jr. Tapered design for the cementless total hip arthroplasty femoral component. Clin Orthop Relat Res. 1997;344:172–178.PubMedCrossRef
45.
go back to reference Mallory TH, Head WC, Lombardi AV Jr, Emerson RH Jr, Eberle RW, Mitchell MB. Clinical and radiographic outcome of a cementless, titanium, plasma spray-coated total hip arthroplasty femoral component. Justification for continuance of use. J Arthroplasty. 1996;11:653–660.PubMedCrossRef Mallory TH, Head WC, Lombardi AV Jr, Emerson RH Jr, Eberle RW, Mitchell MB. Clinical and radiographic outcome of a cementless, titanium, plasma spray-coated total hip arthroplasty femoral component. Justification for continuance of use. J Arthroplasty. 1996;11:653–660.PubMedCrossRef
46.
go back to reference Mallory TH, Lombardi AV Jr, Leith JR, Fujita H, Hartman JF, Capps SG, Kefauver CA, Adams JB, Vorys GC. Minimal 10-year results of a tapered cementless femoral component in total hip arthroplasty. J Arthroplasty. 2001;16(8 Suppl 1):49–54.PubMedCrossRef Mallory TH, Lombardi AV Jr, Leith JR, Fujita H, Hartman JF, Capps SG, Kefauver CA, Adams JB, Vorys GC. Minimal 10-year results of a tapered cementless femoral component in total hip arthroplasty. J Arthroplasty. 2001;16(8 Suppl 1):49–54.PubMedCrossRef
47.
go back to reference Mallory TH, Lombardi AV Jr, Leith JR, Fujita H, Hartman JF, Capps SG, Kefauver CA, Adams JB, Vorys GC. Why a taper? J Bone Joint Surg Am. 2002;84(Suppl 2):81–89.PubMed Mallory TH, Lombardi AV Jr, Leith JR, Fujita H, Hartman JF, Capps SG, Kefauver CA, Adams JB, Vorys GC. Why a taper? J Bone Joint Surg Am. 2002;84(Suppl 2):81–89.PubMed
48.
go back to reference McLaughlin JR, Lee KR. Total hip arthroplasty with an uncemented femoral component. Excellent results at ten-year follow-up. J Bone Joint Surg Br. 1997;79:900–907.PubMedCrossRef McLaughlin JR, Lee KR. Total hip arthroplasty with an uncemented femoral component. Excellent results at ten-year follow-up. J Bone Joint Surg Br. 1997;79:900–907.PubMedCrossRef
49.
go back to reference McLaughlin JR, Lee KR. Total hip arthroplasty in young patients. 8- to 13-year results using an uncemented stem. Clin Orthop Relat Res. 2000;373:153–163.PubMedCrossRef McLaughlin JR, Lee KR. Total hip arthroplasty in young patients. 8- to 13-year results using an uncemented stem. Clin Orthop Relat Res. 2000;373:153–163.PubMedCrossRef
50.
go back to reference McLaughlin JR, Lee KR. The outcome of total hip replacement in obese and non-obese patients at 10- to 18-years. J Bone Joint Surg Br. 2006;88:1286–1292.PubMedCrossRef McLaughlin JR, Lee KR. The outcome of total hip replacement in obese and non-obese patients at 10- to 18-years. J Bone Joint Surg Br. 2006;88:1286–1292.PubMedCrossRef
51.
go back to reference McLaughlin JR, Lee KR. Total hip arthroplasty with an uncemented tapered femoral component. J Bone Joint Surg Am. 2008;90:1290–1296.PubMedCrossRef McLaughlin JR, Lee KR. Total hip arthroplasty with an uncemented tapered femoral component. J Bone Joint Surg Am. 2008;90:1290–1296.PubMedCrossRef
52.
go back to reference Mendenhall S. Hospital resources and implant cost management—a 2006 update. Orthopedic Network News. 2007;18:13–19. Mendenhall S. Hospital resources and implant cost management—a 2006 update. Orthopedic Network News. 2007;18:13–19.
53.
go back to reference Mineo R, Berend KR, Mallory TH, Lombardi AV Jr. A lateralized tapered titanium cementless femoral component does not increase thigh or trochanteric pain. Surg Tech Int. 2007;16:210–214. Mineo R, Berend KR, Mallory TH, Lombardi AV Jr. A lateralized tapered titanium cementless femoral component does not increase thigh or trochanteric pain. Surg Tech Int. 2007;16:210–214.
54.
go back to reference Morshed S, Bozic KJ, Ries MD, Malchau H, Colford JM Jr. Comparison of cemented and uncemented fixation in total hip replacement. A meta-analysis. Acta Orthop. 2007;78:315–326.PubMedCrossRef Morshed S, Bozic KJ, Ries MD, Malchau H, Colford JM Jr. Comparison of cemented and uncemented fixation in total hip replacement. A meta-analysis. Acta Orthop. 2007;78:315–326.PubMedCrossRef
55.
go back to reference Park MS, Choi BW, Kim SJ, Park JH. Plasma spray-coated Ti femoral component for cementless total hip arthroplasty. J Arthroplasty. 2003;18:626–630.PubMedCrossRef Park MS, Choi BW, Kim SJ, Park JH. Plasma spray-coated Ti femoral component for cementless total hip arthroplasty. J Arthroplasty. 2003;18:626–630.PubMedCrossRef
56.
go back to reference Parvizi J, Keisu KS, Hozack WJ, Sharkey PF, Rothman RH. Primary total hip arthroplasty with an uncemented femoral component: a long-term study of the Taperloc stem. J Arthroplasty. 2004;19:151–156.PubMedCrossRef Parvizi J, Keisu KS, Hozack WJ, Sharkey PF, Rothman RH. Primary total hip arthroplasty with an uncemented femoral component: a long-term study of the Taperloc stem. J Arthroplasty. 2004;19:151–156.PubMedCrossRef
57.
go back to reference Purtill JJ, Rothman RH, Hozack WJ, Sharkey PF. Total hip arthroplasty using two different cementless tapered stems. Clin Orthop Relat Res. 2001;393:121–127.PubMedCrossRef Purtill JJ, Rothman RH, Hozack WJ, Sharkey PF. Total hip arthroplasty using two different cementless tapered stems. Clin Orthop Relat Res. 2001;393:121–127.PubMedCrossRef
58.
go back to reference Rao RR, Sharkey PF, Hozack WJ, Eng K, Rothman RH. Immediate weightbearing after uncemented total hip arthroplasty. Clin Orthop Relat Res. 1998;349:156–162.PubMedCrossRef Rao RR, Sharkey PF, Hozack WJ, Eng K, Rothman RH. Immediate weightbearing after uncemented total hip arthroplasty. Clin Orthop Relat Res. 1998;349:156–162.PubMedCrossRef
59.
go back to reference Reis MD. Hip arthroplasty: management problems; periprosthetic fractures: early and late. Orthopedics. 1997;20:789–800. Reis MD. Hip arthroplasty: management problems; periprosthetic fractures: early and late. Orthopedics. 1997;20:789–800.
60.
go back to reference Reitman RD, Emerson R, Higgins L, Head W. Thirteen year results of total hip arthroplasty using a tapered titanium femoral component inserted without cement in patients with type C bone. J Arthroplasty. 2003;18(7 Suppl 1):116–121.PubMedCrossRef Reitman RD, Emerson R, Higgins L, Head W. Thirteen year results of total hip arthroplasty using a tapered titanium femoral component inserted without cement in patients with type C bone. J Arthroplasty. 2003;18(7 Suppl 1):116–121.PubMedCrossRef
61.
go back to reference Rorabeck CH, Bourne RB, Mulliken BD, Nayak N, Laupacis A, Tugwell P, Feeney D. Comparative results of cemented and cementless total hip arthroplasty. Clin Orthop Relat Res. 1996;325:330–344.PubMedCrossRef Rorabeck CH, Bourne RB, Mulliken BD, Nayak N, Laupacis A, Tugwell P, Feeney D. Comparative results of cemented and cementless total hip arthroplasty. Clin Orthop Relat Res. 1996;325:330–344.PubMedCrossRef
62.
go back to reference Sakalkale DP, Eng K, Hozack WJ, Rothman RH. Minimum 10-year results of a tapered cementless hip replacement. Clin Orthop Relat Res. 1999;362:138–144.PubMedCrossRef Sakalkale DP, Eng K, Hozack WJ, Rothman RH. Minimum 10-year results of a tapered cementless hip replacement. Clin Orthop Relat Res. 1999;362:138–144.PubMedCrossRef
63.
go back to reference Saleh KJ, Mulhall KJ, Bershadsky B, Ghomrawi HM, White LE, Buyea CM, Krackow KA. Development and validation of a lower-extremity activity scale. Use for patients treated with revision total knee arthroplasty. J Bone Joint Surg Am. 2005;87:1985–1994.PubMedCrossRef Saleh KJ, Mulhall KJ, Bershadsky B, Ghomrawi HM, White LE, Buyea CM, Krackow KA. Development and validation of a lower-extremity activity scale. Use for patients treated with revision total knee arthroplasty. J Bone Joint Surg Am. 2005;87:1985–1994.PubMedCrossRef
64.
go back to reference Schmidt AH, Kyle RF. Periprosthetic fractures of the femur. Orthop Clin North Am. 2002;33:143–152.PubMedCrossRef Schmidt AH, Kyle RF. Periprosthetic fractures of the femur. Orthop Clin North Am. 2002;33:143–152.PubMedCrossRef
65.
go back to reference Tanzer M, Chan S, Brooks CE, Bobyn JD. Primary cementless total hip arthroplasty using a modular femoral component: a minimum 6-year follow-up. J Arthroplasty. 2001;16(8 Suppl 1):64–70.PubMedCrossRef Tanzer M, Chan S, Brooks CE, Bobyn JD. Primary cementless total hip arthroplasty using a modular femoral component: a minimum 6-year follow-up. J Arthroplasty. 2001;16(8 Suppl 1):64–70.PubMedCrossRef
66.
go back to reference Tanzer M, Maloney WJ, Jasty M, Harris WH. The progression of femoral cortical osteolysis in association with total hip arthroplasty without cement. J Bone Joint Surg Am. 1992;74:404–410.PubMed Tanzer M, Maloney WJ, Jasty M, Harris WH. The progression of femoral cortical osteolysis in association with total hip arthroplasty without cement. J Bone Joint Surg Am. 1992;74:404–410.PubMed
67.
go back to reference Urban RM, Jacobs JJ, Sumner DR, Peters CL, Voss FR, Galante JO. The bone-implant interface of femoral stems with non-circumferential porous coating. J Bone Joint Surg Am. 1996;78:1068–1081.PubMed Urban RM, Jacobs JJ, Sumner DR, Peters CL, Voss FR, Galante JO. The bone-implant interface of femoral stems with non-circumferential porous coating. J Bone Joint Surg Am. 1996;78:1068–1081.PubMed
68.
go back to reference Wirz D, Daniels AU, Göpfert B, Morscher EW. Clinical development and current status: Europe. Orthop Clin N Am. 2005;36:63–73.CrossRef Wirz D, Daniels AU, Göpfert B, Morscher EW. Clinical development and current status: Europe. Orthop Clin N Am. 2005;36:63–73.CrossRef
69.
go back to reference Xenos JS, Callaghan JJ, Heekin RD, Hopkinson WJ, Savory CG, Moore MS. The porous-coated anatomic total hip prosthesis, inserted without cement. A prospective study with a minimum of ten years of follow-up. J Bone Joint Surg Am. 1999;81:74–82.PubMed Xenos JS, Callaghan JJ, Heekin RD, Hopkinson WJ, Savory CG, Moore MS. The porous-coated anatomic total hip prosthesis, inserted without cement. A prospective study with a minimum of ten years of follow-up. J Bone Joint Surg Am. 1999;81:74–82.PubMed
Metadata
Title
Survivorship of 2000 Tapered Titanium Porous Plasma-sprayed Femoral Components
Authors
Adolph V. Lombardi Jr., MD
Keith R. Berend, MD
Thomas H. Mallory, MD
Michael D. Skeels, DO
Joanne B. Adams, BFA
Publication date
01-01-2009
Publisher
Springer-Verlag
Published in
Clinical Orthopaedics and Related Research® / Issue 1/2009
Print ISSN: 0009-921X
Electronic ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-008-0568-x

Other articles of this Issue 1/2009

Clinical Orthopaedics and Related Research® 1/2009 Go to the issue

Symposium: Papers Presented at the Hip Society Meetings 2008

Acetabular Loosening Using an Extended Offset Polyethylene Liner

Symposium: Papers Presented at the Hip Society Meetings 2008

Can the Volume of Pelvic Osteolysis be Calculated without Using Computed Tomography?

Symposium: Papers Presented at the Hip Society Meetings 2008

Imaging and Navigation Measurement of Acetabular Component Position in THA

Symposium: Papers Presented at the Hip Society Meetings 2008

Initial American Experience with Hip Resurfacing Following FDA Approval