Skip to main content
Top
Published in: Irish Journal of Medical Science (1971 -) 4/2018

01-11-2018 | Original Article

Port insertion for minimally invasive surgery: a report of practices in the Irish Republic

Authors: Cuan M. Harrington, Dara O. Kavanagh, Sean Tierney, Richard Deane, Dermot Hehir

Published in: Irish Journal of Medical Science (1971 -) | Issue 4/2018

Login to get access

Abstract

Background

With rapidly evolving surgical technologies, minimally invasive surgery (MIS) has become the mainstay approach for many surgeons worldwide. As laparoscopic surgery was introduced in Ireland over two decades ago, we may be encountering a higher prevalence of related complications.

Aims

This study aimed to gather data pertaining to risk factors for port-site herniation in MIS.

Methods

A 14-point anonymous questionnaire was distributed electronically between January and May 2017 to consultant and trainee laparoscopists in the Republic of Ireland. This survey related to laparoscopic volume and surgical approaches to laparoscopic port-sites.

Results

There were 172 eligible responses nationally. Approaches to peritoneal access included Hasson, veress (blind puncture) and SILS were 66.3, 32.6 and 1.2%, respectively. Senior surgeons and specialists in Obstetrics and Gynaecology (OBGYN) reported significantly higher utilisations of closed peritoneal access (p < 0.05). Of the participants, 119 (69.2%) reported using a bladeless trocar over a bladed type. Fascial closure was utilised in 94.2% of ≥ 10 mm and 2.3% of 5-mm ports using absorbable suture in 76.7%, non-absorbable suture in 14.5% and port closure devices in 8.7%. Perceptions of risk factors for PSH were not congruent with significant variations in responses between levels of expertise.

Conclusions

This study demonstrates significant variations in laparoscopic port-site practices amongst surgeons nationally. The new era of practitioners may benefit from evidence-based technical workshops and guidelines to increase awareness and reduce potential complications.
Appendix
Available only for authorised users
Literature
10.
go back to reference Neudecker J, Sauerland S, Neugebauer E, Bergamaschi R, Bonjer HJ, Cuschieri A, Fuchs KH, Jacobi C, Jansen FW, Koivusalo AM, Lacy A, McMahon MJ, Millat B, Schwenk W (2002) The European Association for Endoscopic Surgery clinical practice guideline on the pneumoperitoneum for laparoscopic surgery. Surg Endosc 16(7):1121–1143. https://doi.org/10.1007/s00464-001-9166-7 CrossRefPubMed Neudecker J, Sauerland S, Neugebauer E, Bergamaschi R, Bonjer HJ, Cuschieri A, Fuchs KH, Jacobi C, Jansen FW, Koivusalo AM, Lacy A, McMahon MJ, Millat B, Schwenk W (2002) The European Association for Endoscopic Surgery clinical practice guideline on the pneumoperitoneum for laparoscopic surgery. Surg Endosc 16(7):1121–1143. https://​doi.​org/​10.​1007/​s00464-001-9166-7 CrossRefPubMed
12.
go back to reference Diagnostic Laparoscopy Clinical Guidelines (2005). Editors: Redmond HP, Andrews E, Hill ADK. Clinical Guidelines Committee. Available from: http://www.rcsi.ie. Accessed 04 Sep 2017 Diagnostic Laparoscopy Clinical Guidelines (2005). Editors: Redmond HP, Andrews E, Hill ADK. Clinical Guidelines Committee. Available from: http://​www.​rcsi.​ie. Accessed 04 Sep 2017
13.
14.
go back to reference Fuller J, Scott W, Ashar B, et al (2003) Laparoscopic trocar injuries: a report from a U.S. Food and Drug Administration (FDA) Center for Devices and Radiological Health (CDRH) Systematic Technology Assessment of Medical Products (STAMP) Committee: FDA safety Communication Available from: https://www.fda.gov/medicaldevices/safety. Accessed 04 Sep 2017 Fuller J, Scott W, Ashar B, et al (2003) Laparoscopic trocar injuries: a report from a U.S. Food and Drug Administration (FDA) Center for Devices and Radiological Health (CDRH) Systematic Technology Assessment of Medical Products (STAMP) Committee: FDA safety Communication Available from: https://​www.​fda.​gov/​medicaldevices/​safety. Accessed 04 Sep 2017
15.
go back to reference Chim H, Evans KK, Salgado CJ et al Abdominal wall anatomy and vascular supply. In: Rosen MJ (ed) Chapter 1 from Atlas of abdominal wall reconstruction, 2nd edn. Elsevier, Amsterdam Chim H, Evans KK, Salgado CJ et al Abdominal wall anatomy and vascular supply. In: Rosen MJ (ed) Chapter 1 from Atlas of abdominal wall reconstruction, 2nd edn. Elsevier, Amsterdam
23.
go back to reference Bourne RB, Bitar H, Andreae PR, Martin LM, Finlay JB, Marquis F (1988) In-vivo comparison of four absorbable sutures: Vicryl, Dexon Plus, Maxon and PDS. Can J Surg 31(1):43–45PubMed Bourne RB, Bitar H, Andreae PR, Martin LM, Finlay JB, Marquis F (1988) In-vivo comparison of four absorbable sutures: Vicryl, Dexon Plus, Maxon and PDS. Can J Surg 31(1):43–45PubMed
24.
Metadata
Title
Port insertion for minimally invasive surgery: a report of practices in the Irish Republic
Authors
Cuan M. Harrington
Dara O. Kavanagh
Sean Tierney
Richard Deane
Dermot Hehir
Publication date
01-11-2018
Publisher
Springer London
Published in
Irish Journal of Medical Science (1971 -) / Issue 4/2018
Print ISSN: 0021-1265
Electronic ISSN: 1863-4362
DOI
https://doi.org/10.1007/s11845-017-1732-7

Other articles of this Issue 4/2018

Irish Journal of Medical Science (1971 -) 4/2018 Go to the issue