Skip to main content
Top
Published in: Journal of Children's Orthopaedics 5/2016

Open Access 01-10-2016 | Original Clinical Article

Comparing the mechanical strength of hip spica cast between a conventional and a new method of application

Authors: Kwong-Lee Wan, Rukmanikanthan Shanmugam, Kun-Yun Lee, Aik Saw

Published in: Journal of Children's Orthopaedics | Issue 5/2016

Login to get access

Abstract

Purpose

The current technique of hip spica application is mostly based on a publication by Kumar (J Pediatr Orthop 1(1):97–99, 1981). We modified the technique of hip spica application in order to reduce the rate of breakage across the hip joint and designed this study to compare the strength between hip spica applied according to Kumar’s technique and the new technique.

Methods

We created 12 hip spica casts with 24 hips according to Kumar’s technique, and another 12 casts according to a new technique. The two types of spica were tested with a mechanical testing machine (Instron 3365 series) by using compression loading to failure in flexion, extension, abduction and adduction. Data were analysed in SPSS version 20.0. Comparison of means was done with an independent T test for normally distributed data and the Mann–Whitney test for skewed data.

Results

The new technique involved the creation of three slabs, instead of 14 slabs as described by Kumar. The loads to failure for hip spica cast applied according to the new technique were higher than those applied according to Kumar’s technique, and the differences were statistically significant. The stiffness was also higher in spica casts applied with the new technique; the difference was not statistically significant under extension force.

Conclusion

Hip spica applied with the new technique was stronger than that applied according to Kumar’s technique based on load to failure testing. The new technique of application would potentially reduce the risk of cast breakage during the management of developmental dysplasia of the hip (DDH) and femur fracture in children.
Literature
1.
go back to reference Kumar SJ (1981) Hip spica application for the treatment of congenital dislocation of the hip. J Pediatr Orthop 1(1):97–99CrossRefPubMed Kumar SJ (1981) Hip spica application for the treatment of congenital dislocation of the hip. J Pediatr Orthop 1(1):97–99CrossRefPubMed
4.
go back to reference Chaudhry S, Kang K, Lee MC (2015) Reinforcing a spica cast with a fiberglass bar. Am J Orthop (Belle Mead NJ) 44(11):E423–E426 Chaudhry S, Kang K, Lee MC (2015) Reinforcing a spica cast with a fiberglass bar. Am J Orthop (Belle Mead NJ) 44(11):E423–E426
5.
go back to reference Curtis JF, Killian JT, Alonso JE (1995) Improved treatment of femoral shaft fractures in children utilizing the pontoon spica cast: a long-term follow-up. J Pediatr Orthop 15(1):36–40CrossRefPubMed Curtis JF, Killian JT, Alonso JE (1995) Improved treatment of femoral shaft fractures in children utilizing the pontoon spica cast: a long-term follow-up. J Pediatr Orthop 15(1):36–40CrossRefPubMed
6.
go back to reference Chua YP, Saw A, Gunalan R, Kanthan SR (2012) Application of hip spica cast in paediatric. Malays Orthop J 6(2 (Supplement A)):40 Chua YP, Saw A, Gunalan R, Kanthan SR (2012) Application of hip spica cast in paediatric. Malays Orthop J 6(2 (Supplement A)):40
10.
go back to reference Yassir W, Mahar A, Aminian A, Newton P, Wenger D (2005) A comparison of the fixation stability of multiple screw constructs for two types of pelvic osteotomies. J Pediatr Orthop 25(1):14–17PubMed Yassir W, Mahar A, Aminian A, Newton P, Wenger D (2005) A comparison of the fixation stability of multiple screw constructs for two types of pelvic osteotomies. J Pediatr Orthop 25(1):14–17PubMed
Metadata
Title
Comparing the mechanical strength of hip spica cast between a conventional and a new method of application
Authors
Kwong-Lee Wan
Rukmanikanthan Shanmugam
Kun-Yun Lee
Aik Saw
Publication date
01-10-2016
Publisher
Springer Berlin Heidelberg
Published in
Journal of Children's Orthopaedics / Issue 5/2016
Print ISSN: 1863-2521
Electronic ISSN: 1863-2548
DOI
https://doi.org/10.1007/s11832-016-0770-4

Other articles of this Issue 5/2016

Journal of Children's Orthopaedics 5/2016 Go to the issue