Skip to main content
Top
Published in: Journal of Children's Orthopaedics 5/2012

01-10-2012 | Original Clinical Article

CT and MRI lower extremity torsional profile studies: measurement reproducibility

Authors: Abd R. Muhamad, Joana M. Freitas, James D. Bomar, Jerry Dwek, Harish S. Hosalkar

Published in: Journal of Children's Orthopaedics | Issue 5/2012

Login to get access

Abstract

Background

Assessment of lower extremity (LE) torsional profile using computed tomography (CT) imaging is a well-recognized imaging method that supplements the clinical examination. Magnetic resonance imaging (MRI) is another advanced imaging modality that can be used as an alternative, since there are many growing concerns of radiation exposure with traditional CT studies, particularly in the skeletally immature population.

Methods

Sixty-two patients between the ages of 7 and 19 years were included. Thirty-four had CT and 28 had MRI for assessment of LE torsional profile. All patients had clinical evidence of torsional malalignment. CT and MR images were randomized and de-identified. Two observers measured femoral anteversion and tibial torsion based on previously published methodologies. This exercise was repeated 2 weeks later and the data were tabulated and statistical analysis was performed. Radiation exposure for the patients studied by CT was estimated.

Results

The mean age of the patients was 14.4 years (range 9.5–18.9 years) and 13.8 years (range 7.3–18.9 years) for the CT and MRI groups, respectively. Inter-observer reliability for both CT and MRI studies were excellent. The intra-class correlation coefficient (ICC) for femoral anteversion and tibial torsion studied by CT and MRI for both observers at both times were excellent. The radiation exposure for CT examination averaged 0.3–0.5 mSv, compared to none with the MRI method.

Conclusions

MRI provides a reproducible method for assessing the torsional profile in children and adolescents using similar anatomic landmarks for measurements as those used on CT torsional profile. In circumstances where MRI methods are readily available (and affordable), the CT torsional profile can be replaced with MRI methods, in the current era of growing concerns of radiation hazards and increasing awareness about radiation safety.

Level of evidence

Diagnostic Level III.
Literature
1.
go back to reference Terjesen T, Benum P, Anda S, Svenningsen S (1982) Increased femoral anteversion and osteoarthritis of the hip joint. Acta Orthop Scand 53(4):571–575CrossRef Terjesen T, Benum P, Anda S, Svenningsen S (1982) Increased femoral anteversion and osteoarthritis of the hip joint. Acta Orthop Scand 53(4):571–575CrossRef
2.
go back to reference Hubbard DD, Staheli LT, Chew DE, Mosca VS (1988) Medial femoral torsion and osteoarthritis. J Pediatr Orthop 8(5):540–542CrossRef Hubbard DD, Staheli LT, Chew DE, Mosca VS (1988) Medial femoral torsion and osteoarthritis. J Pediatr Orthop 8(5):540–542CrossRef
3.
go back to reference Tönnis D, Heinecke A (1999) Acetabular and femoral anteversion: relationship with osteoarthritis of the hip. J Bone Joint Surg Am 81(12):1747–1770 Tönnis D, Heinecke A (1999) Acetabular and femoral anteversion: relationship with osteoarthritis of the hip. J Bone Joint Surg Am 81(12):1747–1770
4.
go back to reference Chung CY, Lee KM, Park MS, Lee SH, Choi IH, Cho TJ (2010) Validity and reliability of measuring femoral anteversion and neck-shaft angle in patients with cerebral palsy. J Bone Joint Surg Am 92(5):1195–1205CrossRef Chung CY, Lee KM, Park MS, Lee SH, Choi IH, Cho TJ (2010) Validity and reliability of measuring femoral anteversion and neck-shaft angle in patients with cerebral palsy. J Bone Joint Surg Am 92(5):1195–1205CrossRef
5.
go back to reference Dunn DM (1952) Anteversion of the neck of the femur; a method of measurement. J Bone Joint Surg Br 34-B(2):181–186 Dunn DM (1952) Anteversion of the neck of the femur; a method of measurement. J Bone Joint Surg Br 34-B(2):181–186
6.
go back to reference Dunlap K, Shands AR Jr, Hollister LC Jr, Gaul JS Jr, Streit HA (1953) A new method for determination of torsion of the femur. J Bone Joint Surg Am 35-A(2):289–311 Dunlap K, Shands AR Jr, Hollister LC Jr, Gaul JS Jr, Streit HA (1953) A new method for determination of torsion of the femur. J Bone Joint Surg Am 35-A(2):289–311
7.
go back to reference Magilligan DJ (1956) Calculation of the angle of anteversion by means of horizontal lateral roentgenography. J Bone Joint Surg Am 38-A(6):1231–1246 Magilligan DJ (1956) Calculation of the angle of anteversion by means of horizontal lateral roentgenography. J Bone Joint Surg Am 38-A(6):1231–1246
8.
go back to reference Crane L (1959) Femoral torsion and its relation to toeing-in and toeing-out. J Bone Joint Surg Am 41-A(3):421–428 Crane L (1959) Femoral torsion and its relation to toeing-in and toeing-out. J Bone Joint Surg Am 41-A(3):421–428
9.
go back to reference Hubbard DD, Staheli LT (1972) The direct radiographic measurement of femoral torsion using axial tomography: technic comparison with an indirect radiographic method. Clin Orthop Relat Res 86:16–20CrossRef Hubbard DD, Staheli LT (1972) The direct radiographic measurement of femoral torsion using axial tomography: technic comparison with an indirect radiographic method. Clin Orthop Relat Res 86:16–20CrossRef
10.
go back to reference Berman L, Mitchell R, Katz D (1987) Ultrasound assessment of femoral anteversion. A comparison with computerised tomography. J Bone Joint Surg Br 69(2):268–270 Berman L, Mitchell R, Katz D (1987) Ultrasound assessment of femoral anteversion. A comparison with computerised tomography. J Bone Joint Surg Br 69(2):268–270
11.
go back to reference Lausten GS, Jørgensen F, Boesen J (1989) Measurement of anteversion of the femoral neck. Ultrasound and computerised tomography compared. J Bone Joint Surg Br 71(2):237–239 Lausten GS, Jørgensen F, Boesen J (1989) Measurement of anteversion of the femoral neck. Ultrasound and computerised tomography compared. J Bone Joint Surg Br 71(2):237–239
12.
go back to reference Weiner DS, Cook AJ, Hoyt WA Jr, Oravec CE (1978) Computed tomography in the measurement of femoral anteversion. Orthopedics 1(4):299–306CrossRef Weiner DS, Cook AJ, Hoyt WA Jr, Oravec CE (1978) Computed tomography in the measurement of femoral anteversion. Orthopedics 1(4):299–306CrossRef
13.
go back to reference Jakob RP, Haertel M, Stüssi E (1980) Tibial torsion calculated by computerised tomography and compared to other methods of measurement. J Bone Joint Surg Br 62-B(2):238–242 Jakob RP, Haertel M, Stüssi E (1980) Tibial torsion calculated by computerised tomography and compared to other methods of measurement. J Bone Joint Surg Br 62-B(2):238–242
14.
go back to reference Hernandez RJ, Tachdjian MO, Poznanski AK, Dias LS (1981) CT determination of femoral torsion. AJR Am J Roentgenol 137(1):97–101CrossRef Hernandez RJ, Tachdjian MO, Poznanski AK, Dias LS (1981) CT determination of femoral torsion. AJR Am J Roentgenol 137(1):97–101CrossRef
15.
go back to reference Murphy SB, Simon SR, Kijewski PK, Wilkinson RH, Griscom NT (1987) Femoral anteversion. J Bone Joint Surg Am 69(8):1169–1176 Murphy SB, Simon SR, Kijewski PK, Wilkinson RH, Griscom NT (1987) Femoral anteversion. J Bone Joint Surg Am 69(8):1169–1176
16.
go back to reference Reikerås O, Høiseth A (1989) Torsion of the leg determined by computed tomography. Acta Orthop Scand 60(3):330–333CrossRef Reikerås O, Høiseth A (1989) Torsion of the leg determined by computed tomography. Acta Orthop Scand 60(3):330–333CrossRef
17.
go back to reference Eckhoff DG, Johnson KK (1994) Three-dimensional computed tomography reconstruction of tibial torsion. Clin Orthop Relat Res 302:42–46 Eckhoff DG, Johnson KK (1994) Three-dimensional computed tomography reconstruction of tibial torsion. Clin Orthop Relat Res 302:42–46
18.
go back to reference Tomczak RJ, Guenther KP, Rieber A, Mergo P, Ros PR, Brambs HJ (1997) MR imaging measurement of the femoral antetorsional angle as a new technique: comparison with CT in children and adults. AJR Am J Roentgenol 168(3):791–794CrossRef Tomczak RJ, Guenther KP, Rieber A, Mergo P, Ros PR, Brambs HJ (1997) MR imaging measurement of the femoral antetorsional angle as a new technique: comparison with CT in children and adults. AJR Am J Roentgenol 168(3):791–794CrossRef
19.
go back to reference Bauman PA, Singson R, Hamilton WG (1994) Femoral neck anteversion in ballerinas. Clin Orthop Relat Res 302:57–63 Bauman PA, Singson R, Hamilton WG (1994) Femoral neck anteversion in ballerinas. Clin Orthop Relat Res 302:57–63
20.
go back to reference Guenther KP, Tomczak R, Kessler S, Pfeiffer T, Puhl W (1995) Measurement of femoral anteversion by magnetic resonance imaging–evaluation of a new technique in children and adolescents. Eur J Radiol 21(1):47–52CrossRef Guenther KP, Tomczak R, Kessler S, Pfeiffer T, Puhl W (1995) Measurement of femoral anteversion by magnetic resonance imaging–evaluation of a new technique in children and adolescents. Eur J Radiol 21(1):47–52CrossRef
21.
go back to reference Schneider B, Laubenberger J, Jemlich S, Groene K, Weber HM, Langer M (1997) Measurement of femoral antetorsion and tibial torsion by magnetic resonance imaging. Br J Radiol 70(834):575–579CrossRef Schneider B, Laubenberger J, Jemlich S, Groene K, Weber HM, Langer M (1997) Measurement of femoral antetorsion and tibial torsion by magnetic resonance imaging. Br J Radiol 70(834):575–579CrossRef
22.
go back to reference Brenner D, Elliston C, Hall E, Berdon W (2001) Estimated risks of radiation-induced fatal cancer from pediatric CT. AJR Am J Roentgenol 176(2):289–296CrossRef Brenner D, Elliston C, Hall E, Berdon W (2001) Estimated risks of radiation-induced fatal cancer from pediatric CT. AJR Am J Roentgenol 176(2):289–296CrossRef
23.
go back to reference Brenner DJ, Hall EJ (2007) Computed tomography—an increasing source of radiation exposure. N Engl J Med 357(22):2277–2284CrossRef Brenner DJ, Hall EJ (2007) Computed tomography—an increasing source of radiation exposure. N Engl J Med 357(22):2277–2284CrossRef
24.
go back to reference Brody AS, Frush DP, Huda W, Brent RL; American Academy of Pediatrics Section on Radiology (2007) Radiation risk to children from computed tomography. Pediatrics 120(3):677–682CrossRef Brody AS, Frush DP, Huda W, Brent RL; American Academy of Pediatrics Section on Radiology (2007) Radiation risk to children from computed tomography. Pediatrics 120(3):677–682CrossRef
25.
go back to reference Lee CH, Goo JM, Ye HJ, Ye SJ, Park CM, Chun EJ, Im JG (2008) Radiation dose modulation techniques in the multidetector CT era: from basics to practice. Radiographics 28(5):1451–1459CrossRef Lee CH, Goo JM, Ye HJ, Ye SJ, Park CM, Chun EJ, Im JG (2008) Radiation dose modulation techniques in the multidetector CT era: from basics to practice. Radiographics 28(5):1451–1459CrossRef
26.
go back to reference Koenig JK, Pring ME, Dwek JR (2012) MR evaluation of femoral neck version and tibial torsion. Pediatr Radiol 42(1):113–115CrossRef Koenig JK, Pring ME, Dwek JR (2012) MR evaluation of femoral neck version and tibial torsion. Pediatr Radiol 42(1):113–115CrossRef
27.
go back to reference Portney LG, Watkins MP (2000) Statistical measures of reliability. In: Portney LG, Watkins MP (eds) Foundations of clinical research: applications to practice, 2nd edn. Prentice Hall Health, Upper Saddle River, pp 557–588 Portney LG, Watkins MP (2000) Statistical measures of reliability. In: Portney LG, Watkins MP (eds) Foundations of clinical research: applications to practice, 2nd edn. Prentice Hall Health, Upper Saddle River, pp 557–588
28.
go back to reference Ruwe PA, Gage JR, Ozonoff MB, DeLuca PA (1992) Clinical determination of femoral anteversion. A comparison with established techniques. J Bone Joint Surg Am 74(6):820–830 Ruwe PA, Gage JR, Ozonoff MB, DeLuca PA (1992) Clinical determination of femoral anteversion. A comparison with established techniques. J Bone Joint Surg Am 74(6):820–830
29.
go back to reference Bråten M, Tveit K, Junk S, Aamodt A, Anda S, Terjesen T (2000) The role of fluoroscopy in avoiding rotational deformity of treated femoral shaft fractures: an anatomical and clinical study. Injury 31(5):311–315CrossRef Bråten M, Tveit K, Junk S, Aamodt A, Anda S, Terjesen T (2000) The role of fluoroscopy in avoiding rotational deformity of treated femoral shaft fractures: an anatomical and clinical study. Injury 31(5):311–315CrossRef
30.
go back to reference Kim HD, Lee DS, Eom MJ, Hwang JS, Han NM, Jo GY (2011) Relationship between Physical Examinations and Two-Dimensional Computed Tomographic Findings in Children with Intoeing Gait. Ann Rehabil Med 35(4):491–498CrossRef Kim HD, Lee DS, Eom MJ, Hwang JS, Han NM, Jo GY (2011) Relationship between Physical Examinations and Two-Dimensional Computed Tomographic Findings in Children with Intoeing Gait. Ann Rehabil Med 35(4):491–498CrossRef
31.
go back to reference Stevens KJ, Busse RF, Han E, Brau AC, Beatty PJ, Beaulieu CF, Gold GE (2008) Ankle: isotropic MR imaging with 3D-FSE-cube—initial experience in healthy volunteers. Radiology 249(3):1026–1033CrossRef Stevens KJ, Busse RF, Han E, Brau AC, Beatty PJ, Beaulieu CF, Gold GE (2008) Ankle: isotropic MR imaging with 3D-FSE-cube—initial experience in healthy volunteers. Radiology 249(3):1026–1033CrossRef
32.
go back to reference Davis CP, McKinnon GC, Debatin JF, von Schulthess GK (1996) Ultra-high-speed MR imaging. Eur Radiol 6(3):297–311CrossRef Davis CP, McKinnon GC, Debatin JF, von Schulthess GK (1996) Ultra-high-speed MR imaging. Eur Radiol 6(3):297–311CrossRef
33.
go back to reference Berrington de González A, Mahesh M, Kim KP, Bhargavan M, Lewis R, Mettler F, Land C (2009) Projected cancer risks from computed tomographic scans performed in the United States in 2007. Arch Intern Med 169(22):2071–2077CrossRef Berrington de González A, Mahesh M, Kim KP, Bhargavan M, Lewis R, Mettler F, Land C (2009) Projected cancer risks from computed tomographic scans performed in the United States in 2007. Arch Intern Med 169(22):2071–2077CrossRef
34.
go back to reference Smith-Bindman R, Miglioretti DL, Johnson E, Lee C, Feigelson HS, Flynn M, Greenlee RT, Kruger RL, Hornbrook MC, Roblin D, Solberg LI, Vanneman N, Weinmann S, Williams AE (2012) Use of diagnostic imaging studies and associated radiation exposure for patients enrolled in large integrated health care systems, 1996–2010. JAMA 307(22):2400–2409CrossRef Smith-Bindman R, Miglioretti DL, Johnson E, Lee C, Feigelson HS, Flynn M, Greenlee RT, Kruger RL, Hornbrook MC, Roblin D, Solberg LI, Vanneman N, Weinmann S, Williams AE (2012) Use of diagnostic imaging studies and associated radiation exposure for patients enrolled in large integrated health care systems, 1996–2010. JAMA 307(22):2400–2409CrossRef
35.
go back to reference Smith-Bindman R, Lipson J, Marcus R, Kim KP, Mahesh M, Gould R, Berrington de González A, Miglioretti DL (2009) Radiation dose associated with common computed tomography examinations and the associated lifetime attributable risk of cancer. Arch Intern Med 169(22):2078–2086CrossRef Smith-Bindman R, Lipson J, Marcus R, Kim KP, Mahesh M, Gould R, Berrington de González A, Miglioretti DL (2009) Radiation dose associated with common computed tomography examinations and the associated lifetime attributable risk of cancer. Arch Intern Med 169(22):2078–2086CrossRef
Metadata
Title
CT and MRI lower extremity torsional profile studies: measurement reproducibility
Authors
Abd R. Muhamad
Joana M. Freitas
James D. Bomar
Jerry Dwek
Harish S. Hosalkar
Publication date
01-10-2012
Publisher
Springer Berlin Heidelberg
Published in
Journal of Children's Orthopaedics / Issue 5/2012
Print ISSN: 1863-2521
Electronic ISSN: 1863-2548
DOI
https://doi.org/10.1007/s11832-012-0434-y

Other articles of this Issue 5/2012

Journal of Children's Orthopaedics 5/2012 Go to the issue