Abstract

The frozen elephant trunk (FET) technique is useful in the single-stage treatment of aortic arch aneurysms. Since there is no established implantation method for evaluating the distal end of the FET during surgery, we propose the FET positioning method using the ostium of the coronary artery on transesophageal echocardiography (TEE) as an index. We performed 11 total arch replacement operations using an FET for aortic arch aneurysm. The planned position of the FET was determined by computed tomography (CT), and the distance to the ostium of the coronary artery was measured. Intraoperatively, using TEE as a guide, the FET was implanted using our method. Postoperative CT was evaluated the distance from the planned FET position, and the average and median difference was only 0.96 cm and 0.6 cm, respectively. TEE-guided FET deployment using the coronary artery ostium as an index is a simple and reproducible technique.
Literature
1.
go back to reference Kato M, Ohnishi K, Kaneko M, Ueda T, Kishi D, Mizushima T, et al. New graft-implanting method for thoracic aortic aneurysm or dissection with a stented graft. Circulation. 1996;94:188–93. Kato M, Ohnishi K, Kaneko M, Ueda T, Kishi D, Mizushima T, et al. New graft-implanting method for thoracic aortic aneurysm or dissection with a stented graft. Circulation. 1996;94:188–93.
2.
go back to reference Katayama K, Uchida N, Katayama A, Takahashi S, Takasaki T, Kurosaki T, et al. Multiple factors predict the risk of spinal cord injury after the frozen elephant trunk technique for extended thoracic aortic disease. Eur J Cardio-thorac Surg. 2015;47(4):616–20.CrossRef Katayama K, Uchida N, Katayama A, Takahashi S, Takasaki T, Kurosaki T, et al. Multiple factors predict the risk of spinal cord injury after the frozen elephant trunk technique for extended thoracic aortic disease. Eur J Cardio-thorac Surg. 2015;47(4):616–20.CrossRef
3.
go back to reference Flores J, Kunihara T, Shiiya N, Yoshimoto K, Matsuzaki K, Yasuda K. Extensive deployment of the stented elephant trunk is associated with an increased risk of spinal cord injury. J Thorac Cardiovasc Surg. 2006;131(2):336–42.CrossRef Flores J, Kunihara T, Shiiya N, Yoshimoto K, Matsuzaki K, Yasuda K. Extensive deployment of the stented elephant trunk is associated with an increased risk of spinal cord injury. J Thorac Cardiovasc Surg. 2006;131(2):336–42.CrossRef
4.
go back to reference Uchida N, Katayama A, Higashiue S, Shiono M, Hata M, Minami K, et al. A new device as an open stent graft for extended aortic repair: a multicentre early experience in Japan. Eur J Cardio-thorac Surg. 2016;49(4):1270–8.CrossRef Uchida N, Katayama A, Higashiue S, Shiono M, Hata M, Minami K, et al. A new device as an open stent graft for extended aortic repair: a multicentre early experience in Japan. Eur J Cardio-thorac Surg. 2016;49(4):1270–8.CrossRef
5.
go back to reference Ikeda A, Konishi T, Matsuzaki K, Jikuya T. Radiopaque ruler-guided frozen elephant trunk technique. Ann Vasc Dis. 2016;9(4):352–5.CrossRef Ikeda A, Konishi T, Matsuzaki K, Jikuya T. Radiopaque ruler-guided frozen elephant trunk technique. Ann Vasc Dis. 2016;9(4):352–5.CrossRef
6.
go back to reference Yamanaka K, Ishii H. Three-step method for transesophageal echocardiography-guided implantation of the frozen elephant trunk: how to prevent spinal cord injury. Gen Thorac Cardiovasc Surg. 2019;67(3):340–3.CrossRef Yamanaka K, Ishii H. Three-step method for transesophageal echocardiography-guided implantation of the frozen elephant trunk: how to prevent spinal cord injury. Gen Thorac Cardiovasc Surg. 2019;67(3):340–3.CrossRef
7.
go back to reference Tanaka H, Minatoya K, Matsuda H, Sasaki H, Iba Y, Oda T, et al. Embolism is emerging as a major cause of spinal cord injury after descending and thoracoabdominal aortic repair with a contemporary approach: magnetic resonance findings of spinal cord injury. Interact Cardiovasc Thorac Surg. 2014;19(2):205–10.CrossRef Tanaka H, Minatoya K, Matsuda H, Sasaki H, Iba Y, Oda T, et al. Embolism is emerging as a major cause of spinal cord injury after descending and thoracoabdominal aortic repair with a contemporary approach: magnetic resonance findings of spinal cord injury. Interact Cardiovasc Thorac Surg. 2014;19(2):205–10.CrossRef
Metadata
Title
Novel technique in frozen elephant trunk positioning method using the ostium of the coronary artery on transesophageal echocardiography as an index
Authors
Eijiro Nogami
Kojiro Furukawa
Hideyuki Fumoto
Keiji Kamohara
Publication date
02-07-2022
Publisher
Springer Nature Singapore
Published in
General Thoracic and Cardiovascular Surgery / Issue 11/2022
Print ISSN: 1863-6705
Electronic ISSN: 1863-6713
DOI
https://doi.org/10.1007/s11748-022-01847-x

Other articles of this Issue 11/2022

General Thoracic and Cardiovascular Surgery 11/2022 Go to the issue