Skip to main content
Top
Published in: General Thoracic and Cardiovascular Surgery 7/2022

29-03-2022 | Computed Tomography | Case Report

Perigraft seroma after total aortic arch replacement using Triplex graft

Authors: Yugo Kunibe, Masahiko Ando, Hyoe Komae, Shogo Shimada, Osamu Kinoshita, Haruo Yamauchi, Minoru Ono

Published in: General Thoracic and Cardiovascular Surgery | Issue 7/2022

Login to get access

Abstract

A 42-year-old gentleman underwent total aortic arch replacement with Triplex graft (Terumo corporation, Tokyo, Japan) for acute type A dissection. Sixteen months later, a computed tomography revealed a rapidly enlarging low-density area around the graft, with no contrast enhancement. The area was compressing the mediastinal structures, such as the superior vena cava and right pulmonary artery. Suspecting lymphorrhea or perigraft seroma (PGS), surgical drainage was performed. Although fluid accumulation around the graft was cloudy and yellowish, Gram stain was negative. A fatty preparation was administered from the nasogastric tube, demonstrating no leakage of chyle. Intraoperative lymphangiography with indocyanine green also showed no lymphatic leak. Therefore, PGS was suspected. Fibrin glue was applied to the graft and the surgery was completed. PGS drainage after arch replacement, especially with Triplex graft, is extremely rare. We discuss the strategies of diagnosis and treatment for this uncommon complication after aortic surgery.
Literature
1.
go back to reference Williams GM. The management of massive ultrafiltration distending the aneurysm sac after abdominal aortic aneurysm repair with a polytetrafluoroethylene aortobiiliac graft. J Vasc Surg. 1998;28:551–5.CrossRef Williams GM. The management of massive ultrafiltration distending the aneurysm sac after abdominal aortic aneurysm repair with a polytetrafluoroethylene aortobiiliac graft. J Vasc Surg. 1998;28:551–5.CrossRef
2.
go back to reference Ahn SS, Machleder HI, Gupta R, Moore WS. Perigraft seroma: clinical, histologic, and serologic correlates. Am J Surg. 1987;154:173–8.CrossRef Ahn SS, Machleder HI, Gupta R, Moore WS. Perigraft seroma: clinical, histologic, and serologic correlates. Am J Surg. 1987;154:173–8.CrossRef
3.
go back to reference Blumenberg RM, Gelfand ML, Dale WA. Perigraft seromas complicating arterial grafts. Surgery. 1985;97:194–204.PubMed Blumenberg RM, Gelfand ML, Dale WA. Perigraft seromas complicating arterial grafts. Surgery. 1985;97:194–204.PubMed
4.
go back to reference Kadakol AK, Nypaver TJ, Lin JC, Weaver MR, Karam JL, Reddy DJ, et al. Frequency, risk factors, and management of perigraft seroma after open abdominal aortic aneurysm repair. J Vasc Surg. 2011;54:637–43.CrossRef Kadakol AK, Nypaver TJ, Lin JC, Weaver MR, Karam JL, Reddy DJ, et al. Frequency, risk factors, and management of perigraft seroma after open abdominal aortic aneurysm repair. J Vasc Surg. 2011;54:637–43.CrossRef
5.
go back to reference Sladen JG, Mandl MAJ, Grossman L, Denegrl JF. Fibroblast inhibition: a new and treatable cause of prosthetic graft failure. Am J Surg. 1985;49:587–90.CrossRef Sladen JG, Mandl MAJ, Grossman L, Denegrl JF. Fibroblast inhibition: a new and treatable cause of prosthetic graft failure. Am J Surg. 1985;49:587–90.CrossRef
6.
go back to reference Kondo Y, Muto A, Dardik A, Nishibe M, Nishibe T. Perigraft seroma after surgical aortoiliac aneurysm repair with knitted polyester grafts: report of two cases. Ann Vasc Dis. 2009;2:44–6.CrossRef Kondo Y, Muto A, Dardik A, Nishibe M, Nishibe T. Perigraft seroma after surgical aortoiliac aneurysm repair with knitted polyester grafts: report of two cases. Ann Vasc Dis. 2009;2:44–6.CrossRef
7.
go back to reference Yamauchi T, Kubota S, Hagawa K, Suzuki A. Mediastinal perigraft seroma after repair of type A dissection with a polyester graft. Ann Vasc Dis. 2017;10:51–3.CrossRef Yamauchi T, Kubota S, Hagawa K, Suzuki A. Mediastinal perigraft seroma after repair of type A dissection with a polyester graft. Ann Vasc Dis. 2017;10:51–3.CrossRef
8.
go back to reference Takamoto S, Yasuda K, Tabayashi K, Kyo S, Miyata T, Kazui T, et al. Clinical experience with terumo large diameter graft (Triplex®)-results of a multicenter clinical trial-. Jpn J Cardiovasc Surg. 2007;36:253–60.CrossRef Takamoto S, Yasuda K, Tabayashi K, Kyo S, Miyata T, Kazui T, et al. Clinical experience with terumo large diameter graft (Triplex®)-results of a multicenter clinical trial-. Jpn J Cardiovasc Surg. 2007;36:253–60.CrossRef
9.
go back to reference Ohtake H, Kimura K, Soga S, Sanada J, Matsui O, Watanabe G. Stent-graft deployment to treat a perigraft seroma formed after descending thoracic aortic surgery. J Endovasc Ther. 2007;14:813–5.CrossRef Ohtake H, Kimura K, Soga S, Sanada J, Matsui O, Watanabe G. Stent-graft deployment to treat a perigraft seroma formed after descending thoracic aortic surgery. J Endovasc Ther. 2007;14:813–5.CrossRef
10.
go back to reference Juergen Z, Ulf K, Utz S, Hans S. Treatment of perigraft seroma in expanded polytetrafluoroethylene grafts by sequential fibrin sealing of the outer graft surface. Ann Vasc Surg. 2010;24:1005–14.CrossRef Juergen Z, Ulf K, Utz S, Hans S. Treatment of perigraft seroma in expanded polytetrafluoroethylene grafts by sequential fibrin sealing of the outer graft surface. Ann Vasc Surg. 2010;24:1005–14.CrossRef
Metadata
Title
Perigraft seroma after total aortic arch replacement using Triplex graft
Authors
Yugo Kunibe
Masahiko Ando
Hyoe Komae
Shogo Shimada
Osamu Kinoshita
Haruo Yamauchi
Minoru Ono
Publication date
29-03-2022
Publisher
Springer Nature Singapore
Published in
General Thoracic and Cardiovascular Surgery / Issue 7/2022
Print ISSN: 1863-6705
Electronic ISSN: 1863-6713
DOI
https://doi.org/10.1007/s11748-022-01810-w

Other articles of this Issue 7/2022

General Thoracic and Cardiovascular Surgery 7/2022 Go to the issue