Abstract

Sleeve gastrectomy is currently the most frequently performed bariatric surgery. Postoperative leaks represent the main cause of morbidity in up to 8% of patients with a mortality rate ranging between 0.1 and 5%. However, management of these leaks remains controversial. We report the case of a patient presenting with sepsis 2 weeks after surgery. A subphrenic collection and a leak were found on CT. Despite medical treatment, the patient did not show clinical improvement. Hence, we considered a transgastric endosonographic-guided drainage of the collection using an electrocautery-enhanced lumen-apposing metal stent (LAMS). The procedure underwent uneventfully, and the patient status improved rapidly. Two weeks later, the stent was withdrawn. A follow-up endoscopy 6 weeks later showed closure of the gastric wall defect.
Literature
1.
go back to reference Ali M, El Chaar M, Ghiassi S, et al. American Society for Metabolic and Bariatric Surgery updated position statement on sleeve gastrectomy as a bariatric procedure. Surg. Obes. Relat. Dis. Elsevier Inc.; 2017. p. 1652–7. Ali M, El Chaar M, Ghiassi S, et al. American Society for Metabolic and Bariatric Surgery updated position statement on sleeve gastrectomy as a bariatric procedure. Surg. Obes. Relat. Dis. Elsevier Inc.; 2017. p. 1652–7.
2.
3.
go back to reference Sakran N, Goitein D, Raziel A, et al. Gastric leaks after sleeve gastrectomy: a multicenter experience with 2,834 patients. Surg Endosc. 2013;27:240–5.CrossRef Sakran N, Goitein D, Raziel A, et al. Gastric leaks after sleeve gastrectomy: a multicenter experience with 2,834 patients. Surg Endosc. 2013;27:240–5.CrossRef
4.
go back to reference Gonzalez J, Lorenzo D, Guilbaud T, et al. Internal endoscopic drainage as first line or second line treatment in case of postsleeve gastrectomy fistulas. Endosc Int Open. 2018;06:E745–50.CrossRef Gonzalez J, Lorenzo D, Guilbaud T, et al. Internal endoscopic drainage as first line or second line treatment in case of postsleeve gastrectomy fistulas. Endosc Int Open. 2018;06:E745–50.CrossRef
5.
go back to reference Dammaro C, Lainas P, Dumont JL, et al. Endoscopic internal drainage coupled to prompt external drainage mobilization is an effective approach for the treatment of complicated cases of sleeve gastrectomy. Obes Surg. Springer New York LLC; 2019; Dammaro C, Lainas P, Dumont JL, et al. Endoscopic internal drainage coupled to prompt external drainage mobilization is an effective approach for the treatment of complicated cases of sleeve gastrectomy. Obes Surg. Springer New York LLC; 2019;
6.
go back to reference Donatelli G, Dumont JL, Cereatti F, et al. Treatment of leaks following sleeve gastrectomy by endoscopic internal drainage (EID). Obes Surg. 2015;25:1293–301.CrossRef Donatelli G, Dumont JL, Cereatti F, et al. Treatment of leaks following sleeve gastrectomy by endoscopic internal drainage (EID). Obes Surg. 2015;25:1293–301.CrossRef
7.
go back to reference Rinninella E, Kunda R, Dollhopf M, et al. EUS-guided drainage of pancreatic fluid collections using a novel lumen-apposing metal stent on an electrocautery-enhanced delivery system: a large retrospective study (with video). Gastrointest Endosc Mosby Inc. 2015;82:1039–46.CrossRef Rinninella E, Kunda R, Dollhopf M, et al. EUS-guided drainage of pancreatic fluid collections using a novel lumen-apposing metal stent on an electrocautery-enhanced delivery system: a large retrospective study (with video). Gastrointest Endosc Mosby Inc. 2015;82:1039–46.CrossRef
8.
go back to reference Siddiqui AA, Kowalski TE, Loren DE, et al. Fully covered self-expanding metal stents versus lumen-apposing fully covered self-expanding metal stent versus plastic stents for endoscopic drainage of pancreatic walled-off necrosis: clinical outcomes and success. Gastrointest Endosc Mosby Inc. 2017;85:758–65.CrossRef Siddiqui AA, Kowalski TE, Loren DE, et al. Fully covered self-expanding metal stents versus lumen-apposing fully covered self-expanding metal stent versus plastic stents for endoscopic drainage of pancreatic walled-off necrosis: clinical outcomes and success. Gastrointest Endosc Mosby Inc. 2017;85:758–65.CrossRef
9.
go back to reference Bapaye A, Dubale NA, Sheth KA, et al. Endoscopic ultrasonography-guided transmural drainage of walled-off pancreatic necrosis: comparison between a specially designed fully covered bi-flanged metal stent and multiple plastic stents. Dig Endosc Blackwell Publishing. 2017;29:104–10.CrossRef Bapaye A, Dubale NA, Sheth KA, et al. Endoscopic ultrasonography-guided transmural drainage of walled-off pancreatic necrosis: comparison between a specially designed fully covered bi-flanged metal stent and multiple plastic stents. Dig Endosc Blackwell Publishing. 2017;29:104–10.CrossRef
10.
go back to reference Lakhtakia S, Basha J, Talukdar R, et al. Endoscopic “step-up approach” using a dedicated biflanged metal stent reduces the need for direct necrosectomy in walled-off necrosis (with videos). Gastrointest Endosc Mosby Inc. 2017;85:1243–52.CrossRef Lakhtakia S, Basha J, Talukdar R, et al. Endoscopic “step-up approach” using a dedicated biflanged metal stent reduces the need for direct necrosectomy in walled-off necrosis (with videos). Gastrointest Endosc Mosby Inc. 2017;85:1243–52.CrossRef
Metadata
Title
Endoscopic Ultrasound (EUS)–Guided Drainage of a Postsleeve Gastrectomy Subphrenic Collection Using a Lumen Apposition Stent
Authors
Salvador Machlab
Mireia Pascua-Solé
Leticia Hernández
Alba Lira
Jordi Vives
Patricia Pedregal
Alexis Luna
Félix Junquera
Publication date
01-08-2020
Publisher
Springer US
Published in
Obesity Surgery / Issue 8/2020
Print ISSN: 0960-8923
Electronic ISSN: 1708-0428
DOI
https://doi.org/10.1007/s11695-020-04553-w

Other articles of this Issue 8/2020

Obesity Surgery 8/2020 Go to the issue