Skip to main content
Top
Published in: HAND 1/2015

01-03-2015 | Surgery Articles

Dimensional analysis of the distal phalanx with consideration of distal interphalangeal joint arthrodesis using a headless compression screw

Authors: Michael Darowish, Rodney Brenneman, Justin Bigger

Published in: HAND | Issue 1/2015

Login to get access

Abstract

Background

Headless compression screws have been used for arthrodesis of the distal interphalangeal joint with good clinical results. However, some distal phalanges are too small, thus precluding their use, or increasing complication rates.

Methods

In order to validate our digital measurements, radiographs of five cadaveric hands were obtained. The distal phalanges of these fingers were measured using our institution’s digital radiograph software. The cadavers were then dissected, and the actual phalanges were measured to confirm the accuracy of the digital measurements; 200 consecutive hand radiographs were then measured to obtain average width and heights of the narrowest measurements of the distal phalanx of each finger. Subgroup analysis of each finger for age and gender was completed.

Results and Conclusions

Females were routinely smaller than their male counterparts. No age-related differences were seen. A substantial number of fingers were found to be too small to allow for use of headless compression screws; 42 % of small finger distal phalanges are too small to accommodate 2.8-mm threads, and that number increases to 81 % with 3.2-mm threads and 97 % with 3.5-mm threads. Few distal phalanges, regardless of which finger, are large enough to accommodate 3.5-mm-diameter threads; 22% of female ring finger distal phalanges are smaller than 2.8 mm, and 66 % of ring fingers are smaller than 3.2 mm. Based on our measurements, a surprising number of distal phalanges are smaller than the trailing thread diameter of commonly commercially available headless screws. Care must be taken in selecting implants for distal interphalangeal (DIP) fusion.
Literature
1.
go back to reference Arata J, Ishikawa K, Soadea H, Kitayama T. Arthrodesis of the distal interphalangeal joint using a bioabsorbable rod as an intramedullary nail. Scand J Plast Reconstr Surg Hand Surg. 2003;37:228–31.CrossRefPubMed Arata J, Ishikawa K, Soadea H, Kitayama T. Arthrodesis of the distal interphalangeal joint using a bioabsorbable rod as an intramedullary nail. Scand J Plast Reconstr Surg Hand Surg. 2003;37:228–31.CrossRefPubMed
2.
go back to reference Brutus JP, Palmer AK, Mosher JF, Harley BJ, Loftus JB. Use of a headless compressive screw for distal interphalangeal joint arthrodesis in digits: clinical outcome and review of complications. J Hand Surg [Am]. 2006;31:85–9.CrossRef Brutus JP, Palmer AK, Mosher JF, Harley BJ, Loftus JB. Use of a headless compressive screw for distal interphalangeal joint arthrodesis in digits: clinical outcome and review of complications. J Hand Surg [Am]. 2006;31:85–9.CrossRef
3.
go back to reference Cobb T. Arthroscopic distal interphalangeal joint arthrodesis. Tech Hand Upper Extrem Surg. 2008;12:266–9.CrossRef Cobb T. Arthroscopic distal interphalangeal joint arthrodesis. Tech Hand Upper Extrem Surg. 2008;12:266–9.CrossRef
4.
go back to reference Henry M. Variable pitch headless compression screw treatment of distal phalangeal nonunions. Tech Hand Upper Extrem Surg. 2010;14:230–3.CrossRef Henry M. Variable pitch headless compression screw treatment of distal phalangeal nonunions. Tech Hand Upper Extrem Surg. 2010;14:230–3.CrossRef
5.
go back to reference Kocak E, Carruthers K, Kobus R. Distal interphalangeal joint arthrodesis with the Herbert headless compression screw: outcomes and complications in 64 consecutively treated joints. Hand. 2011;6:56–9.CrossRefPubMedCentralPubMed Kocak E, Carruthers K, Kobus R. Distal interphalangeal joint arthrodesis with the Herbert headless compression screw: outcomes and complications in 64 consecutively treated joints. Hand. 2011;6:56–9.CrossRefPubMedCentralPubMed
6.
go back to reference Lamas-Gomez C, Proubasta I, Escriba I, Itarte J, Caceres E. Distal interphalangeal joint arthrodesis: treatment with Herbert screw. J South Orthop Assoc. 2003;12:154–9.PubMed Lamas-Gomez C, Proubasta I, Escriba I, Itarte J, Caceres E. Distal interphalangeal joint arthrodesis: treatment with Herbert screw. J South Orthop Assoc. 2003;12:154–9.PubMed
7.
go back to reference Leibovic S. Internal fixation for small joint arthrodesis in the hand. The interphalangeal joints. Hand Clin. 1997;13:601–13.PubMed Leibovic S. Internal fixation for small joint arthrodesis in the hand. The interphalangeal joints. Hand Clin. 1997;13:601–13.PubMed
8.
go back to reference Leibovic S. Instructional course lecture. Arthrodesis of the interphalangeal joints with headless compression screws. J Hand Surg [Am]. 2007;32:1113–9.CrossRef Leibovic S. Instructional course lecture. Arthrodesis of the interphalangeal joints with headless compression screws. J Hand Surg [Am]. 2007;32:1113–9.CrossRef
9.
go back to reference Olivier L, Gensigk F, Board T, Kendoff, Krehmeier U, Wolfhard U. Arthrodesis of the distal interphalangeal joint: description of a new technique and clinical follow-up at 2 years. Arch Orthop Trauma Surg. 2008;128:307–11.CrossRefPubMed Olivier L, Gensigk F, Board T, Kendoff, Krehmeier U, Wolfhard U. Arthrodesis of the distal interphalangeal joint: description of a new technique and clinical follow-up at 2 years. Arch Orthop Trauma Surg. 2008;128:307–11.CrossRefPubMed
10.
go back to reference Sabbagh W, Grobbelaar A, Clarke C, Smith P, Harrison D. Long-term results of digital arthrodesis with the Harrison-Nicolle peg. J Hand Surg (Br). 2001;26:568–71.CrossRef Sabbagh W, Grobbelaar A, Clarke C, Smith P, Harrison D. Long-term results of digital arthrodesis with the Harrison-Nicolle peg. J Hand Surg (Br). 2001;26:568–71.CrossRef
11.
go back to reference Shrout PE, Fleiss JL. Intraclass correlations: uses in assessing rater reliability. Psych Bull. 1979;86:420–8.CrossRef Shrout PE, Fleiss JL. Intraclass correlations: uses in assessing rater reliability. Psych Bull. 1979;86:420–8.CrossRef
12.
go back to reference Tomaino MM. Distal interphalangeal joint arthrodesis with screw fixation: why and how. Hand Clin. 2006;22:207–10.CrossRefPubMed Tomaino MM. Distal interphalangeal joint arthrodesis with screw fixation: why and how. Hand Clin. 2006;22:207–10.CrossRefPubMed
13.
go back to reference Wyrsch B, Dawson J, Aufranc S, Weikert D, Milek M. Distal interphalangeal joint arthrodesis comparing tension-band wire and Herbert screw: a biomechanical and dimensional analysis. J Hand Surg [Am]. 1996;21:438–43.CrossRef Wyrsch B, Dawson J, Aufranc S, Weikert D, Milek M. Distal interphalangeal joint arthrodesis comparing tension-band wire and Herbert screw: a biomechanical and dimensional analysis. J Hand Surg [Am]. 1996;21:438–43.CrossRef
14.
go back to reference Zavitsanos G, Watkins F, Britton E, Somia N, Gupta A, Kleinbert G. Distal interphalangeal joint arthrodesis using intramedullary and interosseus fixation. Hand Surg. 1999;4:51–5.CrossRefPubMed Zavitsanos G, Watkins F, Britton E, Somia N, Gupta A, Kleinbert G. Distal interphalangeal joint arthrodesis using intramedullary and interosseus fixation. Hand Surg. 1999;4:51–5.CrossRefPubMed
Metadata
Title
Dimensional analysis of the distal phalanx with consideration of distal interphalangeal joint arthrodesis using a headless compression screw
Authors
Michael Darowish
Rodney Brenneman
Justin Bigger
Publication date
01-03-2015
Publisher
Springer US
Published in
HAND / Issue 1/2015
Print ISSN: 1558-9447
Electronic ISSN: 1558-9455
DOI
https://doi.org/10.1007/s11552-014-9679-x

Other articles of this Issue 1/2015

HAND 1/2015 Go to the issue