Skip to main content
Top
Published in: International Journal of Computer Assisted Radiology and Surgery 5/2019

01-05-2019 | Original Article

Interactive patient-customized curvilinear reformatting for improving neurosurgical planning

Published in: International Journal of Computer Assisted Radiology and Surgery | Issue 5/2019

Login to get access

Abstract

Purpose

Visualizing a brain in its native space plays an essential role during neurosurgical planning because it allows the superficial cerebral veins and surrounding regions to be preserved. This paper describes the use of a visualization tool in which single gadolinium contrast-enhanced T1-weighted magnetic resonance imaging was applied in nondefective and nonresective skulls to promote visualization of important structures.

Methods

A curvilinear reformatting tool was applied on the supratentorial compartment to peel the tissues to the depth of the dura mater and thereby revealing cortical and vascular spatial relationships. The major advantage of our proposed tool is that it does not require coregistration of anatomical and vascular volumes.

Results

The reliability of this technique was supported by comparisons between preoperative images and digital photographs of the brain cortical surface obtained after the dura mater was removed in 20 patients who underwent surgery in the Clinics Hospital of the University of Campinas from January 2017 to April 2018.

Conclusion

Single fat-suppressed GAD contrast-enhanced T1-weighted magnetic resonance scans provide accurate preoperative 3D views of cortical and vascular relationships similar to neurosurgeons’ intraoperative views. In developing countries with limited access to state-of-the-art health technologies, this imaging approach may improve the safety of complex neurosurgeries.
Appendix
Available only for authorised users
Footnotes
1
A triangle with brighter signals is the one that contains samples with a signal intensity at the 70th percentile of the intensities of all projected triangle samples in the ray length of 50 mm. In our tests, 12 uniformly spaced points in barycentric coordinates in each triangle are sufficient for this evaluation.
 
2
Electronic supplementary material accompanying this manuscript.
 
Literature
1.
go back to reference Bastos AC, Comeau RM, Andermann F, Melanson D, Cendes F, Dubeau F, Fontaine S, Tampieri D, Olivier A (1999) Diagnosis of subtle focal dysplastic lesions: curvilinear reformatting from three-dimensional magnetic resonance imaging. Ann Neurol 46(1):88–94CrossRefPubMed Bastos AC, Comeau RM, Andermann F, Melanson D, Cendes F, Dubeau F, Fontaine S, Tampieri D, Olivier A (1999) Diagnosis of subtle focal dysplastic lesions: curvilinear reformatting from three-dimensional magnetic resonance imaging. Ann Neurol 46(1):88–94CrossRefPubMed
2.
go back to reference Bi WL, Brown PA, Abolfotoh M, Al-Mefty O, Mukundan S, Dunn IF (2015) Utility of dynamic computed tomography angiography in the preoperative evaluation of skull base tumors. J Neurol 123(1):1–8 Bi WL, Brown PA, Abolfotoh M, Al-Mefty O, Mukundan S, Dunn IF (2015) Utility of dynamic computed tomography angiography in the preoperative evaluation of skull base tumors. J Neurol 123(1):1–8
6.
go back to reference Huppertz HJ, Kassubek J, Altenmüller DM, Breyer T, Fauser S (2008) Automatic curvilinear reformatting of three-dimensional MRI data of the cerebral cortex. NeuroImage 39(1):80–86CrossRefPubMed Huppertz HJ, Kassubek J, Altenmüller DM, Breyer T, Fauser S (2008) Automatic curvilinear reformatting of three-dimensional MRI data of the cerebral cortex. NeuroImage 39(1):80–86CrossRefPubMed
7.
go back to reference Iglesias JE, Liu CY, Thompson PM, Tu Z (2011) Robust brain extraction across datasets and comparison with publicly available methods. IEEE Trans Med Imaging 30(9):1617–1634CrossRefPubMed Iglesias JE, Liu CY, Thompson PM, Tu Z (2011) Robust brain extraction across datasets and comparison with publicly available methods. IEEE Trans Med Imaging 30(9):1617–1634CrossRefPubMed
8.
go back to reference Loos WS, Yasuda CL, Cendes F, Wu ST (2017) Cortical envelope modeling for interactive patient-customized curvilinear reformatting in the native space. In: Cardoso M et al (eds) Imaging for patient-customized simulations and systems for point-of-care ultrasound (BIVPCS 2017, POCUS 2017), lecture notes in computer science, vol 10549. Springer, Cham Loos WS, Yasuda CL, Cendes F, Wu ST (2017) Cortical envelope modeling for interactive patient-customized curvilinear reformatting in the native space. In: Cardoso M et al (eds) Imaging for patient-customized simulations and systems for point-of-care ultrasound (BIVPCS 2017, POCUS 2017), lecture notes in computer science, vol 10549. Springer, Cham
9.
go back to reference Mäntylä M (1987) An introduction to solid modeling. Computer Science Press Inc., New York Mäntylä M (1987) An introduction to solid modeling. Computer Science Press Inc., New York
12.
go back to reference Sellers G, Wright RS, Haemel N (2015) OpenGL superbible: comprehensive tutorial and reference, 7th edn. Addison-Wesley, Toronto Sellers G, Wright RS, Haemel N (2015) OpenGL superbible: comprehensive tutorial and reference, 7th edn. Addison-Wesley, Toronto
17.
go back to reference Wu ST, Valente AC, de Souza Watanabe L, Yasuda CL, Coan AC, Cendes F (2014) Pre-alignment for co-registration in native space. In: 2014 27th SIBGRAPI conference on graphics, patterns and images, pp 41–48 Wu ST, Valente AC, de Souza Watanabe L, Yasuda CL, Coan AC, Cendes F (2014) Pre-alignment for co-registration in native space. In: 2014 27th SIBGRAPI conference on graphics, patterns and images, pp 41–48
18.
go back to reference Wu ST, Yasuda CL, Cendes F (2012) Interactive curvilinear reformatting in native space. IEEE Trans Visual Comput Graph 18(2):299–308CrossRef Wu ST, Yasuda CL, Cendes F (2012) Interactive curvilinear reformatting in native space. IEEE Trans Visual Comput Graph 18(2):299–308CrossRef
Metadata
Title
Interactive patient-customized curvilinear reformatting for improving neurosurgical planning
Publication date
01-05-2019
Published in
International Journal of Computer Assisted Radiology and Surgery / Issue 5/2019
Print ISSN: 1861-6410
Electronic ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-018-1878-4

Other articles of this Issue 5/2019

International Journal of Computer Assisted Radiology and Surgery 5/2019 Go to the issue