Abstract

Purpose

Due to the high screw malposition rate and the potential risk of neurovascular injury in cervical fixation surgeries, guided tools, mainly computer-assisted surgery navigation systems and rapid prototyping drill templates (RPDTs) have increasingly been developed to help surgeons improve screw placement accuracy. Although RPDTs have been used in cervical surgeries for almost 2 decades, no specific review has been performed detailing the state of this technique. Thus, in the current review, we fully discuss the status of applying RPDTs in cervical surgeries.

Methods

Studies that tested the accuracy and reliability of RPDTs in guiding cervical screw placements were included in this review. The fabrication workflow and usage of RPDTs, the accuracy and reliability of using RPDTs for screw and plate placement, the advantages and disadvantages of RPDTs and their prospects for future applications as a part of cervical fixation instrumentation are discussed.

Results

As the design of RPDTs becomes more rational, the accuracy and reliability of these devices have significantly improved in cervical fixation surgeries. Moreover, RPDTs decrease the intraoperative radiation exposure for surgeons and patients relative to conventional methods. However, some disadvantages also exist. The fabrication of RPDTs is time-consuming, and the time required to learn the related software is long.

Conclusion

We believe that because of their merits, the RPDT technique is worth promoting for use in cervical surgeries. However, the time-consuming fabrication workflow and the long period required to learn the related software might limit its widespread use. In the future, the workflow should be simplified to reduce the extra workload for surgeons. Moreover, more clinical studies with high-level evidence are still needed to further test its accuracy and feasibility.
Literature
1.
go back to reference Hojo Y, Ito M, Suda K, Oda I, Yoshimoto H, Abumi K (2014) A multicenter study on accuracy and complications of freehand placement of cervical pedicle screws under lateral fluoroscopy in different pathological conditions: CT-based evaluation of more than 1,000 screws. Eur Spine J 23(10):2166–2174. doi:10.1007/s00586-014-3470-0 CrossRefPubMed Hojo Y, Ito M, Suda K, Oda I, Yoshimoto H, Abumi K (2014) A multicenter study on accuracy and complications of freehand placement of cervical pedicle screws under lateral fluoroscopy in different pathological conditions: CT-based evaluation of more than 1,000 screws. Eur Spine J 23(10):2166–2174. doi:10.​1007/​s00586-014-3470-0 CrossRefPubMed
3.
4.
go back to reference Goffin J, Van Brussel K, Vander Sloten J, Van Audekercke R, Smet MH, Marchal G, Van Craen W, Swaelens B, Verstreken K (1999) 3D-CT based, personalized drill guide for posterior transarticular screw fixation at C1–C2: technical note. Neuro-Orthop 25(1–2):47–56 Goffin J, Van Brussel K, Vander Sloten J, Van Audekercke R, Smet MH, Marchal G, Van Craen W, Swaelens B, Verstreken K (1999) 3D-CT based, personalized drill guide for posterior transarticular screw fixation at C1–C2: technical note. Neuro-Orthop 25(1–2):47–56
6.
go back to reference Hu Y, Yuan ZS, Kepler CK, Albert TJ, Yuan JB, Dong WX, Sun XY, Wang CT (2014) Deviation analysis of C1–C2 transarticular screw placement assisted by a novel rapid prototyping drill template: a cadaveric study. J Spinal Disord Tech 27(5):E181–E186CrossRefPubMed Hu Y, Yuan ZS, Kepler CK, Albert TJ, Yuan JB, Dong WX, Sun XY, Wang CT (2014) Deviation analysis of C1–C2 transarticular screw placement assisted by a novel rapid prototyping drill template: a cadaveric study. J Spinal Disord Tech 27(5):E181–E186CrossRefPubMed
11.
go back to reference Li XS, Wu ZH, Xia H, Ma XY, Ai FZ, Zhang K, Wang JH, Mai XH, Yin QS (2014) The development and evaluation of individualized templates to assist transoral C2 articular mass or transpedicular screw placement in TARP-IV procedures: adult cadaver specimen study. Clinics 69(11):750–757. doi:10.6061/clinics/2014(11)08 CrossRefPubMedPubMedCentral Li XS, Wu ZH, Xia H, Ma XY, Ai FZ, Zhang K, Wang JH, Mai XH, Yin QS (2014) The development and evaluation of individualized templates to assist transoral C2 articular mass or transpedicular screw placement in TARP-IV procedures: adult cadaver specimen study. Clinics 69(11):750–757. doi:10.​6061/​clinics/​2014(11)08 CrossRefPubMedPubMedCentral
17.
go back to reference Van Cleynenbreugel J, Schutyser F, Goffin J, Van Brussel K, Suetens P (2002) Image-based planning and validation of C1–C2 transarticular screw fixation using personalized drill guides. Computer Aided Surg 7(1):41–48. doi:10.3109/10929080209146015 CrossRef Van Cleynenbreugel J, Schutyser F, Goffin J, Van Brussel K, Suetens P (2002) Image-based planning and validation of C1–C2 transarticular screw fixation using personalized drill guides. Computer Aided Surg 7(1):41–48. doi:10.​3109/​1092908020914601​5 CrossRef
19.
go back to reference Fraser J, Gebhard H, Irie D, Parikh K, Hartl R (2010) Iso-C/3-dimensional neuronavigation versus conventional fluoroscopy for minimally invasive pedicle screw placement in lumbar fusion. Minim Invasive Neurosurg 53(4):184–190. doi:10.1055/s-0030-1267926 CrossRefPubMed Fraser J, Gebhard H, Irie D, Parikh K, Hartl R (2010) Iso-C/3-dimensional neuronavigation versus conventional fluoroscopy for minimally invasive pedicle screw placement in lumbar fusion. Minim Invasive Neurosurg 53(4):184–190. doi:10.​1055/​s-0030-1267926 CrossRefPubMed
23.
go back to reference Luther N, Iorgulescu JB, Geannette C, Gebhard H, Saleh T, Tsiouris AJ, Hartl R (2015) Comparison of navigated versus non-navigated pedicle screw placement in 260 patients and 1434 screws: screw accuracy, screw size, and the complexity of surgery. J Spinal Disord Tech 28(5):E298–303. doi:10.1097/BSD.0b013e31828af33e CrossRefPubMed Luther N, Iorgulescu JB, Geannette C, Gebhard H, Saleh T, Tsiouris AJ, Hartl R (2015) Comparison of navigated versus non-navigated pedicle screw placement in 260 patients and 1434 screws: screw accuracy, screw size, and the complexity of surgery. J Spinal Disord Tech 28(5):E298–303. doi:10.​1097/​BSD.​0b013e31828af33e​ CrossRefPubMed
26.
28.
go back to reference Shimizu M, Takahashi J, Ikegami S, Kuraishi S, Futatsugi T, Kato H (2014) Are pedicle screw perforation rates influenced by registered or unregistered vertebrae in multilevel registration using a CT-based navigation system in the setting of scoliosis? Eur Spine J 23(10):2211–2217. doi:10.1007/s00586-014-3512-7 CrossRefPubMed Shimizu M, Takahashi J, Ikegami S, Kuraishi S, Futatsugi T, Kato H (2014) Are pedicle screw perforation rates influenced by registered or unregistered vertebrae in multilevel registration using a CT-based navigation system in the setting of scoliosis? Eur Spine J 23(10):2211–2217. doi:10.​1007/​s00586-014-3512-7 CrossRefPubMed
30.
go back to reference Ishikawa Y, Kanemura T, Yoshida G, Matsumoto A, Ito Z, Tauchi R, Muramoto A, Ohno S, Nishimura Y (2011) Intraoperative, full-rotation, three-dimensional image (O-arm)-based navigation system for cervical pedicle screw insertion. J Neurosurg Spine 15(5):472–478. doi:10.3171/2011.6.spine10809 CrossRefPubMed Ishikawa Y, Kanemura T, Yoshida G, Matsumoto A, Ito Z, Tauchi R, Muramoto A, Ohno S, Nishimura Y (2011) Intraoperative, full-rotation, three-dimensional image (O-arm)-based navigation system for cervical pedicle screw insertion. J Neurosurg Spine 15(5):472–478. doi:10.​3171/​2011.​6.​spine10809 CrossRefPubMed
33.
go back to reference Shin MH, Hur JW, Ryu KS, Park CK (2015) Prospective comparison study between the fluoroscopy-guided and navigation coupled with O-arm-guided pedicle screw placement in the thoracic and lumbosacral spines. J Spinal Disord Tech 28(6):E347–E351. doi:10.1097/BSD.0b013e31829047a7 CrossRefPubMed Shin MH, Hur JW, Ryu KS, Park CK (2015) Prospective comparison study between the fluoroscopy-guided and navigation coupled with O-arm-guided pedicle screw placement in the thoracic and lumbosacral spines. J Spinal Disord Tech 28(6):E347–E351. doi:10.​1097/​BSD.​0b013e31829047a7​ CrossRefPubMed
36.
38.
48.
go back to reference Bransford RJ, Russo AJ, Freeborn M, Nguyen QT, Lee MJ, Chapman JR, Bellabarba C (2011) Posterior C2 instrumentation accuracy and complications associated with four techniques. Spine 36(14):E936–E943. doi:10.1097/BRS.0b013e3181fdaf06 Bransford RJ, Russo AJ, Freeborn M, Nguyen QT, Lee MJ, Chapman JR, Bellabarba C (2011) Posterior C2 instrumentation accuracy and complications associated with four techniques. Spine 36(14):E936–E943. doi:10.​1097/​BRS.​0b013e3181fdaf06​
49.
go back to reference Yang YL, Zhou DS, He JL (2013) Comparison of isocentric C-arm 3-dimensional navigation and conventional fluoroscopy for C1 lateral mass and C2 pedicle screw placement for atlantoaxial instability. J Spinal Disord Tech 26(3):127–134. doi:10.1097/BSD.0b013e31823d36b6 CrossRefPubMed Yang YL, Zhou DS, He JL (2013) Comparison of isocentric C-arm 3-dimensional navigation and conventional fluoroscopy for C1 lateral mass and C2 pedicle screw placement for atlantoaxial instability. J Spinal Disord Tech 26(3):127–134. doi:10.​1097/​BSD.​0b013e31823d36b6​ CrossRefPubMed
Metadata
Title
Cervical screw placement using rapid prototyping drill templates for navigation: a literature review
Authors
Teng Lu
Chao Liu
Jun Dong
Meng Lu
Haopeng Li
Xijing He
Publication date
01-12-2016
Publisher
Springer Berlin Heidelberg
Published in
International Journal of Computer Assisted Radiology and Surgery / Issue 12/2016
Print ISSN: 1861-6410
Electronic ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-016-1414-3

Other articles of this Issue 12/2016

International Journal of Computer Assisted Radiology and Surgery 12/2016 Go to the issue