Background

The most common modes of failure of cemented unicompartmental knee arthroplasty (UKA) designs are aseptic loosening and unexplained pain at short- to mid-term follow-up, which is likely linked to early fixation failure. Determining these modes of failure remains challenging; conventional radiographs are limited for use in assessing radiolucent lines, with only fair sensitivity and specificity for aseptic loosening.

Questions/Purposes

We sought to characterize the bone-component interface of patients with symptomatic cemented medial unicompartmental knee arthroplasty (UKA) using magnetic resonance imaging (MRI) and to determine the relationship between MRI and conventional radiographic findings.

Methods

This retrospective observational study included 55 consecutive patients with symptomatic cemented UKA. All underwent MRI with addition of multiacquisition variable-resonance image combination (MAVRIC) at an average of 17.8 ± 13.9 months after surgery. MRI studies were reviewed by two independent musculoskeletal radiologists. MRI findings at the bone-cement interface were quantified, including bone marrow edema, fibrous membrane, osteolysis, and loosening. Radiographs were reviewed for existence of radiolucent lines. Inter-rater agreement was determined using Cohen’s κ statistic.

Results

The vast majority of symptomatic UKA patients demonstrated bone marrow edema pattern (71% and 75%, respectively) and fibrous membrane (69% and 89%, respectively) at the femoral and tibial interface. Excellent and substantial inter-rater agreement was found for the femoral and tibial interface, respectively. Furthermore, MRI findings and radiolucent lines observed on conventional radiographs were poorly correlated.

Conclusion

MRI with the addition of MAVRIC sequences could be a complementary tool for assessing symptomatic UKA and for quantifying appearances at the bone-component interface. This technique showed good reproducibility of analysis of the bone-component interface after cemented UKA. Future studies are necessary to define the bone-component interface of symptomatic and asymptomatic UKA patients.
Appendix
Available only for authorised users
Literature
1.
go back to reference Abu-Amer Y, Darwech I, Clohisy JC. Aseptic loosening of total joint replacements: mechanisms underlying osteolysis and potential therapies. Arthritis Res Ther. 2007;9(Suppl 1):S6.CrossRefPubMedPubMedCentral Abu-Amer Y, Darwech I, Clohisy JC. Aseptic loosening of total joint replacements: mechanisms underlying osteolysis and potential therapies. Arthritis Res Ther. 2007;9(Suppl 1):S6.CrossRefPubMedPubMedCentral
2.
go back to reference Agten CA, Del Grande F, Fucentese SF, Blatter S, Pfirrmann CWA, Sutter R. Unicompartmental knee arthroplasty MRI: impact of slice-encoding for metal artefact correction MRI on image quality, findings and therapy decision. Eur Radiol. 2015;25(7):2184–2193.CrossRefPubMed Agten CA, Del Grande F, Fucentese SF, Blatter S, Pfirrmann CWA, Sutter R. Unicompartmental knee arthroplasty MRI: impact of slice-encoding for metal artefact correction MRI on image quality, findings and therapy decision. Eur Radiol. 2015;25(7):2184–2193.CrossRefPubMed
3.
go back to reference Berkowitz JL, Potter HG. Advanced MRI techniques for the hip joint: focus on the postoperative hip. Am J Roentgenol. 2017;209(3):534–543.CrossRef Berkowitz JL, Potter HG. Advanced MRI techniques for the hip joint: focus on the postoperative hip. Am J Roentgenol. 2017;209(3):534–543.CrossRef
4.
go back to reference Chou DTS, Swamy GN, Lewis JR, Badhe NP. Revision of failed unicompartmental knee replacement to total knee replacement. Knee. 2012;19(4):356–359. Chou DTS, Swamy GN, Lewis JR, Badhe NP. Revision of failed unicompartmental knee replacement to total knee replacement. Knee. 2012;19(4):356–359.
5.
go back to reference Citak M, Dersch K, Kamath AF, Haasper C, Gehrke T, Kendoff D. Common causes of failed unicompartmental knee arthroplasty: a single-centre analysis of four hundred and seventy one cases. Int Orthop. 2014;38(5):961–965.CrossRefPubMedPubMedCentral Citak M, Dersch K, Kamath AF, Haasper C, Gehrke T, Kendoff D. Common causes of failed unicompartmental knee arthroplasty: a single-centre analysis of four hundred and seventy one cases. Int Orthop. 2014;38(5):961–965.CrossRefPubMedPubMedCentral
6.
go back to reference van der List JP, Zuiderbaan HA, Pearle AD. Why do medial unicompartmental knee arthroplasties fail today? J Arthroplasty. 2016;31(5):1016–1021.CrossRefPubMed van der List JP, Zuiderbaan HA, Pearle AD. Why do medial unicompartmental knee arthroplasties fail today? J Arthroplasty. 2016;31(5):1016–1021.CrossRefPubMed
7.
go back to reference Epinette J-A, Brunschweiler B, Mertl P, Mole D, Cazenave A, French Society for Hip and Knee. Unicompartmental knee arthroplasty modes of failure: wear is not the main reason for failure: a multicentre study of 418 failed knees. Orthop Traumatol Surg Res. 2012;98(6 Suppl):S124–30.CrossRefPubMed Epinette J-A, Brunschweiler B, Mertl P, Mole D, Cazenave A, French Society for Hip and Knee. Unicompartmental knee arthroplasty modes of failure: wear is not the main reason for failure: a multicentre study of 418 failed knees. Orthop Traumatol Surg Res. 2012;98(6 Suppl):S124–30.CrossRefPubMed
8.
go back to reference Fritz J, Lurie B, Potter HG. MR Imaging of knee arthroplasty implants. RadoiGraphics. 2015;35(5):1483–1501.CrossRef Fritz J, Lurie B, Potter HG. MR Imaging of knee arthroplasty implants. RadoiGraphics. 2015;35(5):1483–1501.CrossRef
9.
go back to reference Goodfellow JW, Kershaw CJ, Benson MK, O’Connor JJ. The Oxford Knee for unicompartmental osteoarthritis. The first 103 cases. J Bone Joint Surg Br. 1988;70(5):692–701.CrossRefPubMed Goodfellow JW, Kershaw CJ, Benson MK, O’Connor JJ. The Oxford Knee for unicompartmental osteoarthritis. The first 103 cases. J Bone Joint Surg Br. 1988;70(5):692–701.CrossRefPubMed
10.
go back to reference Gulati A, Chau R, Pandit HG, et al. The incidence of physiological radiolucency following Oxford unicompartmental knee replacement and its relationship to outcome. J Bone Joint Surg Br. 2009;91(7):896–902.CrossRefPubMed Gulati A, Chau R, Pandit HG, et al. The incidence of physiological radiolucency following Oxford unicompartmental knee replacement and its relationship to outcome. J Bone Joint Surg Br. 2009;91(7):896–902.CrossRefPubMed
11.
go back to reference Halawa M, Lee AJ, Ling RS, Vangala SS. The shear strength of trabecular bone from the femur, and some factors affecting the shear strength of the cement-bone interface. Arch Orthop Trauma Surg. 1978;92(1):19–30.CrossRefPubMed Halawa M, Lee AJ, Ling RS, Vangala SS. The shear strength of trabecular bone from the femur, and some factors affecting the shear strength of the cement-bone interface. Arch Orthop Trauma Surg. 1978;92(1):19–30.CrossRefPubMed
12.
go back to reference Hayashi D, Englund M, Roemer FW, et al. Knee malalignment is associated with an increased risk for incident and enlarging bone marrow lesions in the more loaded compartments: The MOST study. Osteoarthr Cartil. 2012;20(11):1227–1233.CrossRefPubMedPubMedCentral Hayashi D, Englund M, Roemer FW, et al. Knee malalignment is associated with an increased risk for incident and enlarging bone marrow lesions in the more loaded compartments: The MOST study. Osteoarthr Cartil. 2012;20(11):1227–1233.CrossRefPubMedPubMedCentral
13.
go back to reference Hayter CL, Koff MF, Shah P, Koch KM, Miller TT, Potter HG. MRI after arthroplasty: Comparison of MAVRIC and conventional fast spin-echo techniques. Am J Roentgenol. 2011;197(3):405–411.CrossRef Hayter CL, Koff MF, Shah P, Koch KM, Miller TT, Potter HG. MRI after arthroplasty: Comparison of MAVRIC and conventional fast spin-echo techniques. Am J Roentgenol. 2011;197(3):405–411.CrossRef
14.
go back to reference Hayter CL, Gold SL, Koff MF, et al. MRI findings in painful metal-on-metal hip arthroplasty. Am J Roentgenol. 2012;199(4):884–893.CrossRef Hayter CL, Gold SL, Koff MF, et al. MRI findings in painful metal-on-metal hip arthroplasty. Am J Roentgenol. 2012;199(4):884–893.CrossRef
15.
go back to reference Heyse TJ, Chong LR, Davis J, Boettner F, Haas SB, Potter HG. MRI analysis of the component-bone interface after TKA. Knee. 2012;19(4):290–294.CrossRefPubMed Heyse TJ, Chong LR, Davis J, Boettner F, Haas SB, Potter HG. MRI analysis of the component-bone interface after TKA. Knee. 2012;19(4):290–294.CrossRefPubMed
16.
go back to reference Heyse TJ, Figiel J, Hähnlein U, et al. MRI after unicondylar knee arthroplasty: the preserved compartments. Knee. 2012;19(6):923–926.CrossRefPubMed Heyse TJ, Figiel J, Hähnlein U, et al. MRI after unicondylar knee arthroplasty: the preserved compartments. Knee. 2012;19(6):923–926.CrossRefPubMed
17.
go back to reference Hooper GJ, Maxwell AR, Wilkinson B, et al. The early radiological results of the uncemented Oxford medial compartment knee replacement. J Bone Joint Surg Br. 2012;94(3):334–338.CrossRefPubMed Hooper GJ, Maxwell AR, Wilkinson B, et al. The early radiological results of the uncemented Oxford medial compartment knee replacement. J Bone Joint Surg Br. 2012;94(3):334–338.CrossRefPubMed
18.
go back to reference Hooper N, Snell D, Hooper G, Maxwell R, Frampton C. The five-year radiological results of the uncemented Oxford medial compartment knee arthroplasty. Bone Joint J. 2015;97–B(10):1358–1363.CrossRefPubMed Hooper N, Snell D, Hooper G, Maxwell R, Frampton C. The five-year radiological results of the uncemented Oxford medial compartment knee arthroplasty. Bone Joint J. 2015;97–B(10):1358–1363.CrossRefPubMed
19.
go back to reference Jacobs CA, Christensen CP, Karthikeyan T. Subchondral bone marrow edema had greater effect on postoperative pain after medial unicompartmental knee arthroplasty than total knee arthroplasty. J Arthroplasty. 2016;31(2):491–494.CrossRefPubMed Jacobs CA, Christensen CP, Karthikeyan T. Subchondral bone marrow edema had greater effect on postoperative pain after medial unicompartmental knee arthroplasty than total knee arthroplasty. J Arthroplasty. 2016;31(2):491–494.CrossRefPubMed
20.
go back to reference Kalra S, Smith TO, Berko B, Walton NP. Assessment of radiolucent lines around the Oxford unicompartmental knee replacement: sensitivity and specificity for loosening. J Bone Joint Surg Br. 2011;93(6):777–781.CrossRefPubMed Kalra S, Smith TO, Berko B, Walton NP. Assessment of radiolucent lines around the Oxford unicompartmental knee replacement: sensitivity and specificity for loosening. J Bone Joint Surg Br. 2011;93(6):777–781.CrossRefPubMed
21.
go back to reference Kleeblad LJ, van der List JP, Zuiderbaan HA, Pearle AD. Regional femoral and tibial radiolucency in cemented unicompartmental knee arthroplasty and the relationship to functional outcomes. J Arthroplasty. 2017;32(11):3345–3351.CrossRefPubMed Kleeblad LJ, van der List JP, Zuiderbaan HA, Pearle AD. Regional femoral and tibial radiolucency in cemented unicompartmental knee arthroplasty and the relationship to functional outcomes. J Arthroplasty. 2017;32(11):3345–3351.CrossRefPubMed
22.
go back to reference Koff MF, Shah P, Potter HG. Clinical implementation of MRI of joint arthroplasty. Am J Roentgenol. 2014;203(1):154–161.CrossRef Koff MF, Shah P, Potter HG. Clinical implementation of MRI of joint arthroplasty. Am J Roentgenol. 2014;203(1):154–161.CrossRef
23.
go back to reference Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics. 1977;33(1):159.CrossRefPubMed Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics. 1977;33(1):159.CrossRefPubMed
24.
go back to reference Li AE, Sneag DB, Iv HGG, Johnson CC, Miller TT, Potter HG. Total Knee Arthroplasty: diagnostic accuracy of patterns of synovitis at MR imaging 1. Radiology. 2016;281(2):1–8. Li AE, Sneag DB, Iv HGG, Johnson CC, Miller TT, Potter HG. Total Knee Arthroplasty: diagnostic accuracy of patterns of synovitis at MR imaging 1. Radiology. 2016;281(2):1–8.
25.
go back to reference Malcherczyk D, Figiel J, Hahnlein U, Fuchs-Winkelmann S, Efe T, Heyse TJ. MRI following UKA: The component-bone interface. Acta Orthop Belg. 2015;81(1):84–89.PubMed Malcherczyk D, Figiel J, Hahnlein U, Fuchs-Winkelmann S, Efe T, Heyse TJ. MRI following UKA: The component-bone interface. Acta Orthop Belg. 2015;81(1):84–89.PubMed
26.
go back to reference Mandalia V, Eyres K, Schranz P, Toms AD. Evaluation of patients with a painful total knee replacement. J Bone Jt Surg Br. 2008;90–B(3):265–271.CrossRef Mandalia V, Eyres K, Schranz P, Toms AD. Evaluation of patients with a painful total knee replacement. J Bone Jt Surg Br. 2008;90–B(3):265–271.CrossRef
27.
go back to reference Mukherjee K, Pandit H, Dodd CAF, Ostlere S, Murray DW. The Oxford unicompartmental knee arthroplasty: a radiological perspective. Clin Radiol. 2008;63(10):1169–1176.CrossRefPubMed Mukherjee K, Pandit H, Dodd CAF, Ostlere S, Murray DW. The Oxford unicompartmental knee arthroplasty: a radiological perspective. Clin Radiol. 2008;63(10):1169–1176.CrossRefPubMed
28.
go back to reference Park CN, Zuiderbaan HA, Chang A, Khamaisy S, Pearle AD, Ranawat AS. Role of magnetic resonance imaging in the diagnosis of the painful unicompartmental knee arthroplasty. Knee. 2015;22(4):341–346.CrossRefPubMed Park CN, Zuiderbaan HA, Chang A, Khamaisy S, Pearle AD, Ranawat AS. Role of magnetic resonance imaging in the diagnosis of the painful unicompartmental knee arthroplasty. Knee. 2015;22(4):341–346.CrossRefPubMed
29.
go back to reference Potter HG, Foo LF. Magnetic resonance imaging of joint arthroplasty. Orthop Clin North Am. 2006;37(3):361–373.CrossRefPubMed Potter HG, Foo LF. Magnetic resonance imaging of joint arthroplasty. Orthop Clin North Am. 2006;37(3):361–373.CrossRefPubMed
30.
go back to reference Small SR, Berend ME, Rogge RD, Archer DB, Kingman AL, Ritter MA. Tibial loading after UKA: Evaluation of tibial slope, resection depth, medial shift and component rotation. J Arthroplasty. 2013;28(9 SUPPL):179–183.CrossRefPubMed Small SR, Berend ME, Rogge RD, Archer DB, Kingman AL, Ritter MA. Tibial loading after UKA: Evaluation of tibial slope, resection depth, medial shift and component rotation. J Arthroplasty. 2013;28(9 SUPPL):179–183.CrossRefPubMed
31.
go back to reference Sofka CM, Potter HG, Figgie M, Laskin R. Magnetic resonance imaging of total knee arthroplasty. Clin Orthop Relat Res. 2003;(406):129–135.CrossRef Sofka CM, Potter HG, Figgie M, Laskin R. Magnetic resonance imaging of total knee arthroplasty. Clin Orthop Relat Res. 2003;(406):129–135.CrossRef
32.
go back to reference Talbot BS, Weinberg EP. MR imaging with metal-suppression sequences for evaluation of total joint arthroplasty. Radiographics. 2015;36(1):209–225.CrossRefPubMed Talbot BS, Weinberg EP. MR imaging with metal-suppression sequences for evaluation of total joint arthroplasty. Radiographics. 2015;36(1):209–225.CrossRefPubMed
33.
go back to reference Temmerman OPP, Raijmakers PGHM, Berkhof J, Hoekstra OS, Teule GJJ, Heyligers IC. Accuracy of diagnostic imaging techniques in the diagnosis of aseptic loosening of the femoral component of a hip prosthesis: a meta-analysis. J Bone Joint Surg Br. 2005;87(6):781–785.CrossRefPubMed Temmerman OPP, Raijmakers PGHM, Berkhof J, Hoekstra OS, Teule GJJ, Heyligers IC. Accuracy of diagnostic imaging techniques in the diagnosis of aseptic loosening of the femoral component of a hip prosthesis: a meta-analysis. J Bone Joint Surg Br. 2005;87(6):781–785.CrossRefPubMed
Metadata
Title
MRI Findings at the Bone-Component Interface in Symptomatic Unicompartmental Knee Arthroplasty and the Relationship to Radiographic Findings
Authors
Laura Jill Kleeblad, MD
Hendrik A. Zuiderbaan, MD, PhD
Alissa J. Burge, MD
Mark J. Amirtharaj, BS
Hollis G. Potter, MD
Andrew D. Pearle, MD
Publication date
01-10-2018
Publisher
Springer US
Published in
HSS Journal ® / Issue 3/2018
Print ISSN: 1556-3316
Electronic ISSN: 1556-3324
DOI
https://doi.org/10.1007/s11420-018-9629-1

Other articles of this Issue 3/2018

HSS Journal ® 3/2018 Go to the issue