Skip to main content
Top
Published in: HSS Journal ® 2/2011

01-07-2011 | Original Article

A Pre-Clinical Test Platform for the Functional Evaluation of Scaffolds for Musculoskeletal Defects: The Meniscus

Authors: Suzanne A. Maher, PhD, Scott A. Rodeo, MD, Hollis G. Potter, MD, Lawrence J. Bonassar, PhD, Timothy M. Wright, PhD, Russell F. Warren, MD

Published in: HSS Journal ® | Issue 2/2011

Login to get access

Abstract

In an attempt to delay the progression of osteoarthritis from an index injury, early intervention via repair of injured musculoskeletal soft tissue has been advocated. Despite the development of a number of scaffolds intended to treat soft tissue defects, information about their functional performance is lacking. The goal of this study was to consolidate a suite of in vitro and in vivo models into a pre-clinical test platform to assess the functional performance of meniscal repair scaffolds. Our objective was to assess the ability of a scaffold (Actifit™; Orteq, UK) to carry load without detrimentally abrading against articular cartilage. Three test modules were used to assess the functional performance of meniscal repair scaffolds. The first module tested the ability of the scaffold to carry load in an in vitro model designed to measure the change in normal contact stress magnitude on the tibial plateau of cadaveric knees after scaffold implantation. The second module assessed the in vitro frictional coefficient of the scaffold against cartilage to assess the likelihood that the scaffold would destructively abrade against articular cartilage in vivo. The third module consisted of an assessment of functional performance in vivo by measuring the structure and composition of articular cartilage across the tibial plateau 12 months after scaffold implantation in an ovine model. In vitro, the scaffold improved contact mechanics relative to a partly meniscectomized knee suggesting that, in vivo, less damage would be seen in the scaffold implanted knees vs. partly meniscectomized knees. However, there was no significant difference in the condition of articular cartilage between the two groups. Moreover, in spite of the high coefficient of friction between the scaffold and articular cartilage, there was no significant damage in the articular cartilage underneath the scaffold. The discrepancy between the in vitro and in vivo models was likely influenced by the abundant tissue generated within the scaffold and the unexpected tissue that regenerated within the site of the partial meniscectomy. We are currently augmenting our suite of tests so that we can pre-clinically evaluate the functional performance at time zero and as a function of time after implantation.
Literature
1.
go back to reference Agneskirchner JD, Hurschler C, Stukenborg-Colsman C, Imhoff AB, Lobenhoffer P. Effect of high tibial flexion osteotomy on cartilage pressure and joint kinematics: a biomechanical study in human cadaveric knees. Arch Orthop Trauma Surg 2004; 124:575–84.CrossRef Agneskirchner JD, Hurschler C, Stukenborg-Colsman C, Imhoff AB, Lobenhoffer P. Effect of high tibial flexion osteotomy on cartilage pressure and joint kinematics: a biomechanical study in human cadaveric knees. Arch Orthop Trauma Surg 2004; 124:575–84.CrossRef
2.
go back to reference Angele P, Johnstone B, Kujat R, Zellner J, Nerlich M, Goldberg V, Yoo J. Stem cell based tissue engineering for meniscus repair. J Biomed Mater Res A. 2008 May;85(2):445–55.CrossRef Angele P, Johnstone B, Kujat R, Zellner J, Nerlich M, Goldberg V, Yoo J. Stem cell based tissue engineering for meniscus repair. J Biomed Mater Res A. 2008 May;85(2):445–55.CrossRef
3.
go back to reference Arnoczky SP, Cook JL, Carter T, Turner S. Translational Models for Studying Meniscal Repair and Replacement: What they can and cannot tell us.Tissue Eng Part B Rev. 2009 Aug 21. (Epub ahead of print) Arnoczky SP, Cook JL, Carter T, Turner S. Translational Models for Studying Meniscal Repair and Replacement: What they can and cannot tell us.Tissue Eng Part B Rev. 2009 Aug 21. (Epub ahead of print)
4.
go back to reference Aufderheide AC, Athanasiou KA (2007) Assessment of a bovine co-culture, scaffold-free method for growing meniscus-shaped constructs. Tissue Eng 13(9): 2195–205.CrossRef Aufderheide AC, Athanasiou KA (2007) Assessment of a bovine co-culture, scaffold-free method for growing meniscus-shaped constructs. Tissue Eng 13(9): 2195–205.CrossRef
5.
go back to reference Becker R, Wirz D, Wolf C, Göpfert B, Nebelung W, Friederich N (2005) Measurement of meniscofemoral contact pressure after repair of bucket-handle tears with biodegradable implants. Arch Orthop Trauma Surg 125(4):254–60. Epub 2004 Sep 7CrossRef Becker R, Wirz D, Wolf C, Göpfert B, Nebelung W, Friederich N (2005) Measurement of meniscofemoral contact pressure after repair of bucket-handle tears with biodegradable implants. Arch Orthop Trauma Surg 125(4):254–60. Epub 2004 Sep 7CrossRef
6.
go back to reference Brophy RH, Cottrell J, Rodeo SA, Wright TM, Warren RF, Maher SA. Implantation of a synthetic meniscal scaffold improves joint contact mechanics in a partial meniscectomy cadaver model. J Biomed Mater Res A. 2010 Mar 1;92(3):1154–61.PubMed Brophy RH, Cottrell J, Rodeo SA, Wright TM, Warren RF, Maher SA. Implantation of a synthetic meniscal scaffold improves joint contact mechanics in a partial meniscectomy cadaver model. J Biomed Mater Res A. 2010 Mar 1;92(3):1154–61.PubMed
7.
go back to reference Burger C, Mueller M, Wlodarczyk P, Goost H, Tolba RH, Rangger C, Kabir K, Weber O. The sheep as a knee osteoarthritis model: early cartilage changes after meniscus injury and repair. Lab Anim. 2007 Oct;41(4):420–31.CrossRef Burger C, Mueller M, Wlodarczyk P, Goost H, Tolba RH, Rangger C, Kabir K, Weber O. The sheep as a knee osteoarthritis model: early cartilage changes after meniscus injury and repair. Lab Anim. 2007 Oct;41(4):420–31.CrossRef
8.
go back to reference Chevrier A, Nelea M, Hurtig MB, Hoemann CD, Buschmann MD.Meniscus structure in human, sheep, and rabbit for animal models of meniscus repair. J Orthop Res. 2009 Feb 25 (Epub ahead of print) Chevrier A, Nelea M, Hurtig MB, Hoemann CD, Buschmann MD.Meniscus structure in human, sheep, and rabbit for animal models of meniscus repair. J Orthop Res. 2009 Feb 25 (Epub ahead of print)
9.
go back to reference Chiari C, Koller U, Dorotka R, Eder C, Plasenzotti R, Lang S, Ambrosio L, Tognana E, Kon E, Salter D, Nehrer S (2006) A tissue engineering approach to meniscus regeneration in a sheep model. Osteoarthritis Cartilage 14(10):1056–65. Epub 2006 May 30.CrossRef Chiari C, Koller U, Dorotka R, Eder C, Plasenzotti R, Lang S, Ambrosio L, Tognana E, Kon E, Salter D, Nehrer S (2006) A tissue engineering approach to meniscus regeneration in a sheep model. Osteoarthritis Cartilage 14(10):1056–65. Epub 2006 May 30.CrossRef
10.
go back to reference Duffy GP, Crowder AR, Trousdale RR, Berry DJ. Cemented total knee arthroplasty using a modern prosthesis in young patients with osteoarthritis. J Arthroplasty. 2007 Sep;22(6 Suppl 2):67–70.CrossRef Duffy GP, Crowder AR, Trousdale RR, Berry DJ. Cemented total knee arthroplasty using a modern prosthesis in young patients with osteoarthritis. J Arthroplasty. 2007 Sep;22(6 Suppl 2):67–70.CrossRef
11.
go back to reference Duffy GP, Trousdale RT, Stuart MJ (1998) Total knee arthroplasty in patients 55 years old or younger. 10- to 17-year results. Clin Orthop Relat Res 356:22–7.CrossRef Duffy GP, Trousdale RT, Stuart MJ (1998) Total knee arthroplasty in patients 55 years old or younger. 10- to 17-year results. Clin Orthop Relat Res 356:22–7.CrossRef
12.
go back to reference Gleghorn JP, Doty SB, Warren RF, Wright TM, Maher SA, Bonassar LJ (2010) Analysis of frictional behavior and changes in morphology resulting from cartilage articulation with porous polyurethane foams. J Orthop Res 28(10):1292–1299CrossRef Gleghorn JP, Doty SB, Warren RF, Wright TM, Maher SA, Bonassar LJ (2010) Analysis of frictional behavior and changes in morphology resulting from cartilage articulation with porous polyurethane foams. J Orthop Res 28(10):1292–1299CrossRef
13.
go back to reference Haut Donahue TL, Hull ML, Rashid MM, Jacobs CR. 2003. How the stiffness of meniscal attachments and meniscal material properties affect tibio-femoral contact pressure computed using a validated finite element model of the human knee joint. J. Biomech. 36(1):19–34.CrossRef Haut Donahue TL, Hull ML, Rashid MM, Jacobs CR. 2003. How the stiffness of meniscal attachments and meniscal material properties affect tibio-femoral contact pressure computed using a validated finite element model of the human knee joint. J. Biomech. 36(1):19–34.CrossRef
14.
go back to reference Heinlein B, Kutzner I, Graichen F, Bender A, Rohlmann A, Halder AM, Beier A, Bergmann G (2009) ESB Clinical Biomechanics Award 2008: Complete data of total knee replacement loading for level walking and stair climbing measured in vivo with a follow-up of 6–10 months. Clin Biomech (Bristol, Avon) 24(4): 315–26. Epub 2009 Mar 13.CrossRef Heinlein B, Kutzner I, Graichen F, Bender A, Rohlmann A, Halder AM, Beier A, Bergmann G (2009) ESB Clinical Biomechanics Award 2008: Complete data of total knee replacement loading for level walking and stair climbing measured in vivo with a follow-up of 6–10 months. Clin Biomech (Bristol, Avon) 24(4): 315–26. Epub 2009 Mar 13.CrossRef
15.
go back to reference Hofmann AA, Heithoff SM, Camargo M. Cementless total knee arthroplasty in patients 50 years or younger. Clin Orthop Relat Res. 2002 Nov;(404):102–107.CrossRef Hofmann AA, Heithoff SM, Camargo M. Cementless total knee arthroplasty in patients 50 years or younger. Clin Orthop Relat Res. 2002 Nov;(404):102–107.CrossRef
16.
go back to reference Kang SW, Son SM, Lee JS, Lee ES, Lee KY, Park SG, Park JH, Kim BS. Regeneration of whole meniscus using meniscal cells and polymer scaffolds in a rabbit total meniscectomy model. J Biomed Mater Res A. 2006 Sep 1;78(3):659–71.CrossRef Kang SW, Son SM, Lee JS, Lee ES, Lee KY, Park SG, Park JH, Kim BS. Regeneration of whole meniscus using meniscal cells and polymer scaffolds in a rabbit total meniscectomy model. J Biomed Mater Res A. 2006 Sep 1;78(3):659–71.CrossRef
17.
go back to reference Kelly BT, Robertson W, Potter HG, Deng XH, Turner AS, Lyman S, Warren RF, Rodeo SA (2007) Hydrogel meniscal replacement in the sheep knee: preliminary evaluation of chondroprotective effects. Am J Sports Med 35(1):43–52. Epub 2006 Sep 6.CrossRef Kelly BT, Robertson W, Potter HG, Deng XH, Turner AS, Lyman S, Warren RF, Rodeo SA (2007) Hydrogel meniscal replacement in the sheep knee: preliminary evaluation of chondroprotective effects. Am J Sports Med 35(1):43–52. Epub 2006 Sep 6.CrossRef
18.
go back to reference Kon E, Chiari C, Marcacci M, Delcogliano M, Salter DM, Martin I, Ambrosio L, Fini M, Tschon M, Tognana E, Plasenzotti R, Nehrer S. Tissue engineering for total meniscal substitution: animal study in sheep model. Tissue Eng Part A. 2008 Jun;14(6):1067–80.CrossRef Kon E, Chiari C, Marcacci M, Delcogliano M, Salter DM, Martin I, Ambrosio L, Fini M, Tschon M, Tognana E, Plasenzotti R, Nehrer S. Tissue engineering for total meniscal substitution: animal study in sheep model. Tissue Eng Part A. 2008 Jun;14(6):1067–80.CrossRef
19.
go back to reference Kurosawa, H, Fukubayashi, T, Nakajima, H. 1980. Load-bearing mode of the knee joint. Clinical Orthopaedics and Related Research, 149:283–90. Kurosawa, H, Fukubayashi, T, Nakajima, H. 1980. Load-bearing mode of the knee joint. Clinical Orthopaedics and Related Research, 149:283–90.
20.
go back to reference Lee SJ, Aadalen KJ, Malaviya P, et al. (2006) Tibiofemoral contact mechanics after serial medial meniscectomies in the human cadaveric knee. Am J Sports Med 34:1334–44.CrossRef Lee SJ, Aadalen KJ, Malaviya P, et al. (2006) Tibiofemoral contact mechanics after serial medial meniscectomies in the human cadaveric knee. Am J Sports Med 34:1334–44.CrossRef
21.
go back to reference Levy, IM, Torzilli, PA, Gould, JD, Warren, RF. 1989. The effect of lateral meniscectomy on motion of the knee. J Bone Joint Surg Am. 71(3):401–6.CrossRef Levy, IM, Torzilli, PA, Gould, JD, Warren, RF. 1989. The effect of lateral meniscectomy on motion of the knee. J Bone Joint Surg Am. 71(3):401–6.CrossRef
22.
go back to reference Levy, IM, Torzilli, PA, Warren, RF. 1982. The effect of medial meniscectomy on anterior-posterior motion of the knee. J Bone Joint Surg Am. 64:883–8.CrossRef Levy, IM, Torzilli, PA, Warren, RF. 1982. The effect of medial meniscectomy on anterior-posterior motion of the knee. J Bone Joint Surg Am. 64:883–8.CrossRef
23.
go back to reference Long JP, Santner TJ, Bartel DL. Hip resurfacing increases bone strains associated with short-term femoral neck fracture. J Orthop Res. 2009 Oct;27(10):1319–25.CrossRef Long JP, Santner TJ, Bartel DL. Hip resurfacing increases bone strains associated with short-term femoral neck fracture. J Orthop Res. 2009 Oct;27(10):1319–25.CrossRef
24.
go back to reference Maher SA, Rodeo SA, Doty SB, Brophy R, Potter H, Foo LF, Rosenblatt L, Deng XH, Turner AS, Wright TM, Warren RF. Evaluation of a porous polyurethane scaffold in a partial meniscal defect ovine model. Arthroscopy. 2010 Nov;26(11):1510–9. Epub 2010 Sep 19.CrossRef Maher SA, Rodeo SA, Doty SB, Brophy R, Potter H, Foo LF, Rosenblatt L, Deng XH, Turner AS, Wright TM, Warren RF. Evaluation of a porous polyurethane scaffold in a partial meniscal defect ovine model. Arthroscopy. 2010 Nov;26(11):1510–9. Epub 2010 Sep 19.CrossRef
25.
go back to reference Martinek V, Ueblacker P, Bräun K, Nitschke S, Mannhardt R, Specht K, Gansbacher B, Imhoff AB (2006) Second generation of meniscus transplantation: in-vivo study with tissue engineered meniscus replacement. Arch Orthop Trauma Surg. 126(4):228–34. Epub 2005 Oct 8.CrossRef Martinek V, Ueblacker P, Bräun K, Nitschke S, Mannhardt R, Specht K, Gansbacher B, Imhoff AB (2006) Second generation of meniscus transplantation: in-vivo study with tissue engineered meniscus replacement. Arch Orthop Trauma Surg. 126(4):228–34. Epub 2005 Oct 8.CrossRef
26.
go back to reference Messner, K., Gillquist, J. 1993. Prosthetic replacement of the rabbit medial meniscus. J Biomed Mater Res. 27:1165–73.CrossRef Messner, K., Gillquist, J. 1993. Prosthetic replacement of the rabbit medial meniscus. J Biomed Mater Res. 27:1165–73.CrossRef
27.
go back to reference Mündermann A, Dyrby CO, D’Lima DD, Colwell CW Jr, Andriacchi TP. In vivo knee loading characteristics during activities of daily living as measured by an instrumented total knee replacement. J Orthop Res. 2008 Sep;26(9):1167–72.CrossRef Mündermann A, Dyrby CO, D’Lima DD, Colwell CW Jr, Andriacchi TP. In vivo knee loading characteristics during activities of daily living as measured by an instrumented total knee replacement. J Orthop Res. 2008 Sep;26(9):1167–72.CrossRef
28.
go back to reference Rodkey WG (2000) Basic biology of the meniscus and response to injury. Instr Course Lect 49:189–93. Review.PubMed Rodkey WG (2000) Basic biology of the meniscus and response to injury. Instr Course Lect 49:189–93. Review.PubMed
29.
go back to reference Sheng PY, Konttinen L, Lehto M, Ogino D, Jämsen E, Nevalainen J, Pajamäki J, Halonen P, Konttinen YT. Revision total knee arthroplasty: 1990 through 2002. A review of the Finnish arthroplasty registry. J Bone Joint Surg Am. 2006 Jul;88(7):1425–30.PubMed Sheng PY, Konttinen L, Lehto M, Ogino D, Jämsen E, Nevalainen J, Pajamäki J, Halonen P, Konttinen YT. Revision total knee arthroplasty: 1990 through 2002. A review of the Finnish arthroplasty registry. J Bone Joint Surg Am. 2006 Jul;88(7):1425–30.PubMed
30.
go back to reference Tapper JE, Fukushima S, Azuma H, Thornton GM, Ronsky JL, Shrive NG, Frank CB. Dynamic in vivo kinematics of the intact ovine stifle joint. J Orthop Res. 2006 Apr;24(4):782–92.CrossRef Tapper JE, Fukushima S, Azuma H, Thornton GM, Ronsky JL, Shrive NG, Frank CB. Dynamic in vivo kinematics of the intact ovine stifle joint. J Orthop Res. 2006 Apr;24(4):782–92.CrossRef
31.
go back to reference Testa Pezzin AP, Cardoso TP, do Carmo Alberto Rincón M, de Carvalho Zavaglia CA, de Rezende Duek EA (2003) Bioreabsorbable polymer scaffold as temporary meniscal prosthesis. Artif Organs 27(5):428–31.CrossRef Testa Pezzin AP, Cardoso TP, do Carmo Alberto Rincón M, de Carvalho Zavaglia CA, de Rezende Duek EA (2003) Bioreabsorbable polymer scaffold as temporary meniscal prosthesis. Artif Organs 27(5):428–31.CrossRef
32.
go back to reference Vaziri A, Nayeb-Hashemi H, Singh A, Tafti BA (2008) Influence of meniscectomy and meniscus replacement on the stress distribution in human knee joint. Ann Biomed Eng 36(8):1335–44. Epub 2008 May 22.CrossRef Vaziri A, Nayeb-Hashemi H, Singh A, Tafti BA (2008) Influence of meniscectomy and meniscus replacement on the stress distribution in human knee joint. Ann Biomed Eng 36(8):1335–44. Epub 2008 May 22.CrossRef
33.
go back to reference Weinand C, Peretti GM, Adams SB Jr, Bonassar LJ, Randolph MA, Gill TJ (2006) An allogenic cell-based implant for meniscal lesions. Am J Sports Med 34(11): 1779–89. Epub 2006 Jul 26.CrossRef Weinand C, Peretti GM, Adams SB Jr, Bonassar LJ, Randolph MA, Gill TJ (2006) An allogenic cell-based implant for meniscal lesions. Am J Sports Med 34(11): 1779–89. Epub 2006 Jul 26.CrossRef
34.
go back to reference Wheaton AJ, Dodge GR, Borthakur A, Kneeland JB, Schumacher HR, Reddy R. Detection of changes in articular cartilage proteoglycan by T1 rho imaging. JOR 2005; 23: 102–108.CrossRef Wheaton AJ, Dodge GR, Borthakur A, Kneeland JB, Schumacher HR, Reddy R. Detection of changes in articular cartilage proteoglycan by T1 rho imaging. JOR 2005; 23: 102–108.CrossRef
35.
go back to reference Wood, DJ, Minns, RJ, Strover, A. 1990. Replacement of the rabbit medial meniscus with a polyester-carbon fibre bioprosthesis. Biomaterials 11:13–16.CrossRef Wood, DJ, Minns, RJ, Strover, A. 1990. Replacement of the rabbit medial meniscus with a polyester-carbon fibre bioprosthesis. Biomaterials 11:13–16.CrossRef
Metadata
Title
A Pre-Clinical Test Platform for the Functional Evaluation of Scaffolds for Musculoskeletal Defects: The Meniscus
Authors
Suzanne A. Maher, PhD
Scott A. Rodeo, MD
Hollis G. Potter, MD
Lawrence J. Bonassar, PhD
Timothy M. Wright, PhD
Russell F. Warren, MD
Publication date
01-07-2011
Publisher
Springer New York
Published in
HSS Journal ® / Issue 2/2011
Print ISSN: 1556-3316
Electronic ISSN: 1556-3324
DOI
https://doi.org/10.1007/s11420-010-9188-6

Other articles of this Issue 2/2011

HSS Journal ® 2/2011 Go to the issue