Skip to main content
Top
Published in: Sleep and Breathing 1/2018

01-03-2018 | Sleep Breathing Physiology and Disorders • Original Article

Predictors of CPAP compliance in different clinical settings: primary care versus sleep unit

Authors: Núria Nadal, Jordi de Batlle, Ferran Barbé, Josep Ramon Marsal, Alicia Sánchez-de-la-Torre, Nuria Tarraubella, Merce Lavega, Manuel Sánchez-de-la-Torre

Published in: Sleep and Breathing | Issue 1/2018

Login to get access

Abstract

Background

Good adherence to continuous positive airway pressure (CPAP) treatment improves the patient’s quality of life and decreases the risk of cardiovascular disease. Previous studies that have analyzed the adherence to CPAP were performed in a sleep unit (SU) setting. The involvement of primary care (PC) in the management of obstructive sleep apnea (OSA) patients receiving CPAP treatment could introduce factors related to the adherence to treatment.

Objectives

The objective was to compare the baseline predictors of CPAP compliance in SU and PC settings.

Methods

OSA patients treated with CPAP were followed for 6 months in SU or PC setting. We included baseline clinical and anthropometrical variables, the Epworth Sleep Scale (ESS) score, the quality of life index, and the Charlson index. A logistic regression was performed for each group to determine the CPAP compliance predictors. Discrimination and calibration were performed using the area under the curve and Hosmer-Lemeshow tests.

Results

We included 191 patients: 91 in the PC group and 100 in the SU group. In 74.9% of the patients, the compliance was ≥ 4 h per day, with 80% compliance in the SU setting and 69.2% compliance in the PC setting (p = 0.087). The predictors of CPAP compliance were different between SU and PC settings. Body mass index, ESS, and CPAP pressure were predictors in the SU setting, and ESS, gender, and waist circumference were predictors in the PC setting.

Conclusions

The predictors of adequate CPAP compliance vary between SU and PC settings. Detecting compliance predictors could help in the planning of early interventions to improve CPAP adherence.
Literature
2.
go back to reference Heinzer R, Vat S, Marques-Vidal P, Marti-Soler H, Andries D, Tobback N, Mooser V, Preisig M, Malhotra A, Waeber G, Vollenweider P, Tafti M, Haba-Rubio J (2015) Prevalence of sleep-disordered breathing in the general population: the HypnoLaus study. Lancet Respir Med 3(4):310–318. doi:10.1016/S2213-2600(15)00043-0 CrossRefPubMedPubMedCentral Heinzer R, Vat S, Marques-Vidal P, Marti-Soler H, Andries D, Tobback N, Mooser V, Preisig M, Malhotra A, Waeber G, Vollenweider P, Tafti M, Haba-Rubio J (2015) Prevalence of sleep-disordered breathing in the general population: the HypnoLaus study. Lancet Respir Med 3(4):310–318. doi:10.​1016/​S2213-2600(15)00043-0 CrossRefPubMedPubMedCentral
4.
go back to reference Sánchez-de-la-Torre M, Nadal N, Cortijo A, Masa JF, Duran-Cantolla J, Valls J et al (2015) Role of primary care in the follow-up of patients with obstructive sleep apnoea undergoing CPAP treatment: a randomised controlled trial. Thorax 70(4):346–352. doi:10.1136/thoraxjnl-2014-206287 CrossRefPubMed Sánchez-de-la-Torre M, Nadal N, Cortijo A, Masa JF, Duran-Cantolla J, Valls J et al (2015) Role of primary care in the follow-up of patients with obstructive sleep apnoea undergoing CPAP treatment: a randomised controlled trial. Thorax 70(4):346–352. doi:10.​1136/​thoraxjnl-2014-206287 CrossRefPubMed
5.
go back to reference Chai-Coetzer CL, Antic NA, Rowland LS, Reed RL, Esterman A, Catcheside PG et al (2013) Primary care vs specialist sleep center management of obstructive sleep apnea and daytime sleepiness and quality of life: a randomized trial. JAMA 309(10):997–1004. doi:10.1001/jama.2013.1823 CrossRefPubMed Chai-Coetzer CL, Antic NA, Rowland LS, Reed RL, Esterman A, Catcheside PG et al (2013) Primary care vs specialist sleep center management of obstructive sleep apnea and daytime sleepiness and quality of life: a randomized trial. JAMA 309(10):997–1004. doi:10.​1001/​jama.​2013.​1823 CrossRefPubMed
6.
go back to reference Barbé F, Durán-Cantolla J, Sánchez-de-la-Torre M, Martínez-Alonso M, Carmona C, Barceló A et al (2012) Effect of continuous positive airway pressure on the incidence of hypertension and cardiovascular events in nonsleepy patients with obstructive sleep apnea: a randomized controlled trial. JAMA 307(20):2161–2168. doi:10.1001/jama.2012.4366 CrossRefPubMed Barbé F, Durán-Cantolla J, Sánchez-de-la-Torre M, Martínez-Alonso M, Carmona C, Barceló A et al (2012) Effect of continuous positive airway pressure on the incidence of hypertension and cardiovascular events in nonsleepy patients with obstructive sleep apnea: a randomized controlled trial. JAMA 307(20):2161–2168. doi:10.​1001/​jama.​2012.​4366 CrossRefPubMed
8.
go back to reference Martínez-García MA, Campos-Rodriguez F, Catalan-Serra P, Soler-Cataluña JJ, Almeida-González C (2012) La Cruz-Moron de I, et al. Cardiovascular mortality in obstructive sleep apnea in the elderly. Role of long-term CPAP treatment: a prospective observational trial. Am J Respir Crit Care Med 186(9):909–916. doi:10.1164/rccm.201203-0448OC CrossRefPubMed Martínez-García MA, Campos-Rodriguez F, Catalan-Serra P, Soler-Cataluña JJ, Almeida-González C (2012) La Cruz-Moron de I, et al. Cardiovascular mortality in obstructive sleep apnea in the elderly. Role of long-term CPAP treatment: a prospective observational trial. Am J Respir Crit Care Med 186(9):909–916. doi:10.​1164/​rccm.​201203-0448OC CrossRefPubMed
10.
go back to reference Siccoli MM, Pepperell JCT, Kohler M, Craig SE, Davies RJO, Stradling JR (2008) Effects of continuous positive airway pressure on quality of life in patients with moderate to severe obstructive sleep apnea: data from a randomized controlled trial. Sleep 31(11):1551–1558CrossRefPubMedPubMedCentral Siccoli MM, Pepperell JCT, Kohler M, Craig SE, Davies RJO, Stradling JR (2008) Effects of continuous positive airway pressure on quality of life in patients with moderate to severe obstructive sleep apnea: data from a randomized controlled trial. Sleep 31(11):1551–1558CrossRefPubMedPubMedCentral
11.
go back to reference Martínez-García MA, Capote F, Campos-Rodriguez F, Lloberes P (2013) Díaz de Atauri MJ, Somoza M, et al. Effect of CPAP on blood pressure in patients with obstructive sleep apnea and resistant hypertension: the HIPARCO randomized clinical trial. JAMA 310(22):2407–2415. doi:10.1001/jama.2013.281250 CrossRefPubMed Martínez-García MA, Capote F, Campos-Rodriguez F, Lloberes P (2013) Díaz de Atauri MJ, Somoza M, et al. Effect of CPAP on blood pressure in patients with obstructive sleep apnea and resistant hypertension: the HIPARCO randomized clinical trial. JAMA 310(22):2407–2415. doi:10.​1001/​jama.​2013.​281250 CrossRefPubMed
13.
go back to reference Kohler M, Smith D, Tippett V, Stradling JR (2009) Predictors of long-term compliance with continuous positive airway pressure. Thorax 135(3):704–709. doi:10.1378/chest.08-2182 Kohler M, Smith D, Tippett V, Stradling JR (2009) Predictors of long-term compliance with continuous positive airway pressure. Thorax 135(3):704–709. doi:10.​1378/​chest.​08-2182
14.
go back to reference Krieger J, Kurtz D, Petiau C, Sforza E, Trautmann D (1996) Long-term compliance with CPAP therapy in obstructive sleep apnea patients and in snorers. Sleep 19(9 Suppl):S136–S143CrossRefPubMed Krieger J, Kurtz D, Petiau C, Sforza E, Trautmann D (1996) Long-term compliance with CPAP therapy in obstructive sleep apnea patients and in snorers. Sleep 19(9 Suppl):S136–S143CrossRefPubMed
15.
go back to reference McArdle N, Devereux G, Heidarnejad H, Engleman HM, Mackay TW, Douglas NJ (1999) Long-term use of CPAP therapy for sleep apnea/hypopnea syndrome. Am J Respir Crit Care Med 159(4 Pt 1):1108–1114CrossRefPubMed McArdle N, Devereux G, Heidarnejad H, Engleman HM, Mackay TW, Douglas NJ (1999) Long-term use of CPAP therapy for sleep apnea/hypopnea syndrome. Am J Respir Crit Care Med 159(4 Pt 1):1108–1114CrossRefPubMed
16.
go back to reference Pelletier-Fleury N, Rakotonanahary D, Fleury B (2001) The age and other factors in the evaluation of compliance with nasal continuous positive airway pressure for obstructive sleep apnea syndrome. A Cox’s proportional hazard analysis. Sleep Med 2(3):225–232CrossRefPubMed Pelletier-Fleury N, Rakotonanahary D, Fleury B (2001) The age and other factors in the evaluation of compliance with nasal continuous positive airway pressure for obstructive sleep apnea syndrome. A Cox’s proportional hazard analysis. Sleep Med 2(3):225–232CrossRefPubMed
17.
go back to reference Hoffstein V, Viner S, Mateika S, Conway J (1992) Treatment of obstructive sleep apnea with nasal continuous positive airway pressure. Patient compliance, perception of benefits, and side effects. Am Rev Respir Dis 145(4 Pt 1):841–845CrossRefPubMed Hoffstein V, Viner S, Mateika S, Conway J (1992) Treatment of obstructive sleep apnea with nasal continuous positive airway pressure. Patient compliance, perception of benefits, and side effects. Am Rev Respir Dis 145(4 Pt 1):841–845CrossRefPubMed
19.
go back to reference Antic NA, Buchan C, Esterman A, Hensley M, Naughton MT, Rowland S et al (2009) A randomized controlled trial of nurse-led care for symptomatic moderate-severe obstructive sleep apnea. Am J Respir Crit Care Med 179(6):501–508. doi:10.1164/rccm.200810-1558OC CrossRefPubMed Antic NA, Buchan C, Esterman A, Hensley M, Naughton MT, Rowland S et al (2009) A randomized controlled trial of nurse-led care for symptomatic moderate-severe obstructive sleep apnea. Am J Respir Crit Care Med 179(6):501–508. doi:10.​1164/​rccm.​200810-1558OC CrossRefPubMed
20.
go back to reference Sawyer AM, Gooneratne NS, Marcus CL, Ofer D, Richards KC, Weaver TE (2011) A systematic review of CPAP adherence across age groups: clinical and empiric insights for developing CPAP adherence interventions. Sleep Med Rev 15(6):343–356CrossRefPubMedPubMedCentral Sawyer AM, Gooneratne NS, Marcus CL, Ofer D, Richards KC, Weaver TE (2011) A systematic review of CPAP adherence across age groups: clinical and empiric insights for developing CPAP adherence interventions. Sleep Med Rev 15(6):343–356CrossRefPubMedPubMedCentral
21.
go back to reference Molina M, Hernandez L, Duran J, Farré R, Rubio R, Navajas D et al (2003) Protocol to evaluate automatic continuous positive airway pressure. Assessment of the usefulness of the Autoset-T device to determine optimal pressure for treating sleep apnea/hypopnea syndrome. Arch Bronconeumol 39(3):118–125CrossRefPubMed Molina M, Hernandez L, Duran J, Farré R, Rubio R, Navajas D et al (2003) Protocol to evaluate automatic continuous positive airway pressure. Assessment of the usefulness of the Autoset-T device to determine optimal pressure for treating sleep apnea/hypopnea syndrome. Arch Bronconeumol 39(3):118–125CrossRefPubMed
22.
go back to reference Jenkinson C, Davies RJ, Mullins R, Stradling JR (1999) Comparison of therapeutic and subtherapeutic nasal continuous positive airway pressure for obstructive sleep apnoea: a randomised prospective parallel trial. Lancet 353(9170):2100–2105CrossRefPubMed Jenkinson C, Davies RJ, Mullins R, Stradling JR (1999) Comparison of therapeutic and subtherapeutic nasal continuous positive airway pressure for obstructive sleep apnoea: a randomised prospective parallel trial. Lancet 353(9170):2100–2105CrossRefPubMed
23.
24.
go back to reference Sin DD, Mayers I, Man GCW, Pawluk L (2002) Long-term compliance rates to continuous positive airway pressure in obstructive sleep apnea: a population-based study. Chest 121(2):430–435CrossRefPubMed Sin DD, Mayers I, Man GCW, Pawluk L (2002) Long-term compliance rates to continuous positive airway pressure in obstructive sleep apnea: a population-based study. Chest 121(2):430–435CrossRefPubMed
25.
go back to reference Campos-Rodriguez F, Martinez-Garcia MA, Reyes-Nuñez N, Caballero-Martinez I, Almeida-Gonzalez CV, Catalan-Serra P et al (2013) Long-term continuous positive airway pressure compliance in females with obstructive sleep apnoea. Eur Respir J 42(5):1255–1262. doi:10.1183/09031936.00165812 CrossRefPubMed Campos-Rodriguez F, Martinez-Garcia MA, Reyes-Nuñez N, Caballero-Martinez I, Almeida-Gonzalez CV, Catalan-Serra P et al (2013) Long-term continuous positive airway pressure compliance in females with obstructive sleep apnoea. Eur Respir J 42(5):1255–1262. doi:10.​1183/​09031936.​00165812 CrossRefPubMed
26.
go back to reference Parthasarathy S, Subramanian S, Quan SF (2014) A multicenter prospective comparative effectiveness study of the effect of physician certification and center accreditation on patient-centered outcomes in obstructive sleep apnea. J Clin Sleep Med 10(3):243–249. doi:10.5664/jcsm.3518 Parthasarathy S, Subramanian S, Quan SF (2014) A multicenter prospective comparative effectiveness study of the effect of physician certification and center accreditation on patient-centered outcomes in obstructive sleep apnea. J Clin Sleep Med 10(3):243–249. doi:10.​5664/​jcsm.​3518
Metadata
Title
Predictors of CPAP compliance in different clinical settings: primary care versus sleep unit
Authors
Núria Nadal
Jordi de Batlle
Ferran Barbé
Josep Ramon Marsal
Alicia Sánchez-de-la-Torre
Nuria Tarraubella
Merce Lavega
Manuel Sánchez-de-la-Torre
Publication date
01-03-2018
Publisher
Springer International Publishing
Published in
Sleep and Breathing / Issue 1/2018
Print ISSN: 1520-9512
Electronic ISSN: 1522-1709
DOI
https://doi.org/10.1007/s11325-017-1549-7

Other articles of this Issue 1/2018

Sleep and Breathing 1/2018 Go to the issue

Sleep Breathing Physiology and Disorders • Editorial (invited)

Comorbid insomnia and sleep apnea: a prevalent but overlooked disorder

Sleep Breathing Physiology and Disorders • Letter to the Editors

Intervention for CPAP adherence in OSAS: a choice to patient or technique?

Sleep Breathing Physiology and Disorders • Original Article

Combination mode of physiological signals for diagnosis of OSAS using portable monitor