Skip to main content
Top
Published in: Journal of Thrombosis and Thrombolysis 3/2021

01-04-2021 | Disseminated Intravascular Coagulation

Excessive fibrinolysis detected with thromboelastography in a case of amniotic fluid embolism: fibrinolysis may precede coagulopathy

Authors: M. Fudaba, D. Tachibana, T. Misugi, A. Nakano, M. Koyama

Published in: Journal of Thrombosis and Thrombolysis | Issue 3/2021

Login to get access

Abstract

Amniotic fluid embolism (AFE) is a catastrophic condition in the peripartum period and still remains as a leading cause of maternal death. Although over 80% of cases of AFE cases are accompanied by coagulopathy, the pathology of disseminated intravascular coagulation is not well understood not only because of its rarity but also because of the limited availability of laboratory testing in emergent clinical settings. We describe a case of AFE whose characteristic data for coagulation and fibrinolysis were timely depicted with sequential thromboelastography. We believe that the point-of-care, which provides information for both coagulopathy and fibrinolysis, may provide crucial data not only for the treatment of postpartum hemorrhage in daily clinical practice but also for the elucidation of AFE pathophysiology.
Literature
1.
go back to reference Amniotic fluid embolism: diagnosis and management. Society for Maternal-Fetal Medicine (SMFM). Electronic address: pubs@smfm.org, Pacheco LD, Saade G, Hankins GD, Clark SL.Society for Maternal-Fetal Medicine (SMFM). Electronic address: pubs@smfm.org, et al. Am J Obstet Gynecol. 2016 ;215(2):B16–24. Amniotic fluid embolism: diagnosis and management. Society for Maternal-Fetal Medicine (SMFM). Electronic address: pubs@smfm.org, Pacheco LD, Saade G, Hankins GD, Clark SL.Society for Maternal-Fetal Medicine (SMFM). Electronic address: pubs@smfm.org, et al. Am J Obstet Gynecol. 2016 ;215(2):B16–24.
2.
go back to reference Collins NF, Bloor M, McDonnell NJ (2013) Hyperfibrinolysis diagnosed by rotational thromboelastometry in a case of suspected amniotic fluid embolism. Int J Obstet Anesth. 22(1):71–76CrossRef Collins NF, Bloor M, McDonnell NJ (2013) Hyperfibrinolysis diagnosed by rotational thromboelastometry in a case of suspected amniotic fluid embolism. Int J Obstet Anesth. 22(1):71–76CrossRef
3.
go back to reference Annecke T, Geisenberger T, Kürzl R, Penning R (2010) Algorithm-based coagulation management of catastrophic amniotic fluid embolism. Heindl B Blood Coagul Fibrinolysis 21(1):95–100CrossRef Annecke T, Geisenberger T, Kürzl R, Penning R (2010) Algorithm-based coagulation management of catastrophic amniotic fluid embolism. Heindl B Blood Coagul Fibrinolysis 21(1):95–100CrossRef
4.
go back to reference Hurwich M, Zimmer D, Guerra E, Evans E, Shire T, Abernathy M, Shreve JT, Kolettis GR, McCurdy MT, Castellino FJ, Walsh M, Hurwich M et al (2016) A Case of Successful Thromboelastographic Guided Resuscitation after Postpartum Hemorrhage and Cardiac Arrest. J Extra Corpor Technol. 48(4):194–197PubMedPubMedCentral Hurwich M, Zimmer D, Guerra E, Evans E, Shire T, Abernathy M, Shreve JT, Kolettis GR, McCurdy MT, Castellino FJ, Walsh M, Hurwich M et al (2016) A Case of Successful Thromboelastographic Guided Resuscitation after Postpartum Hemorrhage and Cardiac Arrest. J Extra Corpor Technol. 48(4):194–197PubMedPubMedCentral
5.
go back to reference Loughran JA, Kitchen TL, Sindhakar S, Ashraf M, Awad M, Kealaher EJ (2019) Rotational thromboelastometry (ROTEM®)-guided diagnosis and management of amniotic fluid embolism. Int J Obstet Anesth. 38:127–130CrossRef Loughran JA, Kitchen TL, Sindhakar S, Ashraf M, Awad M, Kealaher EJ (2019) Rotational thromboelastometry (ROTEM®)-guided diagnosis and management of amniotic fluid embolism. Int J Obstet Anesth. 38:127–130CrossRef
6.
go back to reference Crissman HP, Loder C, Pancaro C, Bell J (2020) Case report of amniotic fluid embolism coagulopathy following abortion; use of viscoelastic point-of-care analysis. BMC Pregnancy Childbirth. 20(1):9CrossRef Crissman HP, Loder C, Pancaro C, Bell J (2020) Case report of amniotic fluid embolism coagulopathy following abortion; use of viscoelastic point-of-care analysis. BMC Pregnancy Childbirth. 20(1):9CrossRef
Metadata
Title
Excessive fibrinolysis detected with thromboelastography in a case of amniotic fluid embolism: fibrinolysis may precede coagulopathy
Authors
M. Fudaba
D. Tachibana
T. Misugi
A. Nakano
M. Koyama
Publication date
01-04-2021
Publisher
Springer US
Published in
Journal of Thrombosis and Thrombolysis / Issue 3/2021
Print ISSN: 0929-5305
Electronic ISSN: 1573-742X
DOI
https://doi.org/10.1007/s11239-020-02237-x

Other articles of this Issue 3/2021

Journal of Thrombosis and Thrombolysis 3/2021 Go to the issue