Excerpt

To the editor—Ethylene oxide (EO), an alkylating compound of high chemical reactivity, is widely used as a sterilisation gas for various medical devices (MD) that are heat-sensitive. This type of sterilisation can cause rare but severe allergic reactions in sensitive patients. Allergic manifestations such as hives/rash, asthma or anaphylactic shock have been noted among patients in repeated contact with EO-sterilised MD. Widespread hypersensitivity to EO has also been documented in numerous dialysis patients [1, 2]. Allergic reactions to EO-treated products have also been described in several children with spina bifida [3]. The high prevalence of sensitisation to EO, and the frequency, unpredictability, and potential danger of anaphylactic reactions to EO have led to the conclusion that EO sterilisation of dialyzers should be discontinued, since alternative modalities of sterilisation are currently available. However, in spite of the progressive desorption of EO after prolonged storage times, residual EO is still detectable in the milligram range. Even though intraoperative rinsing with physiological saline reduced the residual level of EO [4, 5], this approach has not been validated and so safety cannot be guaranteed for the sensitive/allergic patient. …
Literature
1.
go back to reference Ebo DG, Bosmans JL, Couttenye MM, Stevens WJ. Haemodialysis-associated anaphylactic and anaphylactoid reactions. Allergy 2006;61(2):211–20.PubMedCrossRef Ebo DG, Bosmans JL, Couttenye MM, Stevens WJ. Haemodialysis-associated anaphylactic and anaphylactoid reactions. Allergy 2006;61(2):211–20.PubMedCrossRef
2.
go back to reference Purello D’Ambrosio F, Savica V, Gangemi S, Ricciardi L, Bagnato G, Santoro D, Cuzzocrea S, Bellinghieri G. Ethylene oxide allergy in dialysis patients. Nephrol Dial Transplant 1997;12:1461–3.PubMedCrossRef Purello D’Ambrosio F, Savica V, Gangemi S, Ricciardi L, Bagnato G, Santoro D, Cuzzocrea S, Bellinghieri G. Ethylene oxide allergy in dialysis patients. Nephrol Dial Transplant 1997;12:1461–3.PubMedCrossRef
3.
go back to reference Moneret-Vautrin DA, Mata E, Gueant JL, Turgeman D, Laxenaire MC. High risk of anaphylactic shock during surgery for spina bifida. Lancet 1990;335(8693):865–6.PubMedCrossRef Moneret-Vautrin DA, Mata E, Gueant JL, Turgeman D, Laxenaire MC. High risk of anaphylactic shock during surgery for spina bifida. Lancet 1990;335(8693):865–6.PubMedCrossRef
4.
go back to reference Kaku N, Tsumara H, Kataoka M, Taira H, Torisu T. Influence of aeration, storage and rinsing conditions on residual ethylene oxide in freeze-dried bone allograft. J Orthop Sci 2002;7:238–42.PubMedCrossRef Kaku N, Tsumara H, Kataoka M, Taira H, Torisu T. Influence of aeration, storage and rinsing conditions on residual ethylene oxide in freeze-dried bone allograft. J Orthop Sci 2002;7:238–42.PubMedCrossRef
5.
go back to reference Ansorge W, Pelger M, Dietrich W, Baurmeister U. Ethylene oxide in dialyzer rinsing fluid: effect of rinsing technique, dialyzer storage time, and potting compound. Artif Organs 1987;11:118–20.PubMedCrossRef Ansorge W, Pelger M, Dietrich W, Baurmeister U. Ethylene oxide in dialyzer rinsing fluid: effect of rinsing technique, dialyzer storage time, and potting compound. Artif Organs 1987;11:118–20.PubMedCrossRef
Metadata
Title
Surgery in a patient allergic to ethylene oxide
Authors
Vanessa Demontoux
Emilie Moreau
Isabelle Peyron
Valérie Talon
Nejib Khouri
Jean-Paul Morin
Yvonnick Bézie
Publication date
01-04-2008
Publisher
Springer Netherlands
Published in
International Journal of Clinical Pharmacy / Issue 2/2008
Print ISSN: 2210-7703
Electronic ISSN: 2210-7711
DOI
https://doi.org/10.1007/s11096-007-9159-2

Other articles of this Issue 2/2008

International Journal of Clinical Pharmacy 2/2008 Go to the issue