Skip to main content
Top
Published in: Journal of Medical Systems 5/2011

01-10-2011 | Original Paper

Post-Operative Assessment of an Implant Fixation in Anterior Cruciate Ligament Reconstructive Surgery

Authors: Mahmoud Chizari, Martyn Snow, Bin Wang

Published in: Journal of Medical Systems | Issue 5/2011

Login to get access

Abstract

The objective of this paper is to numerically simulate the behaviour of an anterior cruciate ligament (ACL) reconstructed knee using interference screw fixation under a single cycle loading or a cyclic loading test and to compare the numerical results with experimental tests using porcine samples of knee joint. A hyper-elastic material model was used to model the tendon graft and evaluate its elongation during continuous and cyclic tensile loading. The rigidity of the interference screw fixation was also examined using the finite element based numerical model. The finite element model uses the benefit of an anatomical 3D geometry of the tibial bone and tendon graft which was created from a CT scan of a patient.
Literature
1.
go back to reference Uh, B. S., Beynnon, B. D., and Johnson, R. J., The biomechanical background of the reconstruction of the anterior cruciate ligament. Bailliere’s Clin. Orthop. 2:47–62, 1997. Uh, B. S., Beynnon, B. D., and Johnson, R. J., The biomechanical background of the reconstruction of the anterior cruciate ligament. Bailliere’s Clin. Orthop. 2:47–62, 1997.
2.
go back to reference Beynnon, B. D., and Amis, A. A., In vitro testing protocols for the cruciate ligaments and ligament reconstructions. Knee Surg. Sports Traumatol. Arthrosc. 6(1):S70–S76, 1998.CrossRef Beynnon, B. D., and Amis, A. A., In vitro testing protocols for the cruciate ligaments and ligament reconstructions. Knee Surg. Sports Traumatol. Arthrosc. 6(1):S70–S76, 1998.CrossRef
3.
go back to reference Beynnon, B. D., Johnson, R. J., and Fleming, B. C., The science of anterior cruciate ligament rehabilitation. Clin. Orthop. 402:9–20, 2002.CrossRef Beynnon, B. D., Johnson, R. J., and Fleming, B. C., The science of anterior cruciate ligament rehabilitation. Clin. Orthop. 402:9–20, 2002.CrossRef
4.
go back to reference Giurea, M., Zorilla, P., Amis, A. A., et al., Comparative pull-out and cyclic-loading strength tests of anchorage of hamstring tendon grafts in anterior cruciate ligament reconstruction. Am. J. Sports Med. 27:621–625, 1999. Giurea, M., Zorilla, P., Amis, A. A., et al., Comparative pull-out and cyclic-loading strength tests of anchorage of hamstring tendon grafts in anterior cruciate ligament reconstruction. Am. J. Sports Med. 27:621–625, 1999.
5.
go back to reference Brand, J., Weiler, A., Caborn, D. N. M., et al., Graft fixation in cruciate ligament reconstruction. Current concepts. Am. J. Sports Med. 28:761–774, 2000. Brand, J., Weiler, A., Caborn, D. N. M., et al., Graft fixation in cruciate ligament reconstruction. Current concepts. Am. J. Sports Med. 28:761–774, 2000.
6.
go back to reference Brand, J., Pienkowski, D., Steenlage, E., et al., Interference screw fixation strength of a quadrupled hamstring tendon graft is directly related to bone mineral density and insertion torque. Am. J. Sports Med. 28:705–710, 2000. Brand, J., Pienkowski, D., Steenlage, E., et al., Interference screw fixation strength of a quadrupled hamstring tendon graft is directly related to bone mineral density and insertion torque. Am. J. Sports Med. 28:705–710, 2000.
7.
go back to reference Kohn, D., and Rose, C., Primary stability of interference screw fixation. Influence of screw diameter and insertion torque. Am. J. Sports Med. 22:334–338, 1994.CrossRef Kohn, D., and Rose, C., Primary stability of interference screw fixation. Influence of screw diameter and insertion torque. Am. J. Sports Med. 22:334–338, 1994.CrossRef
8.
go back to reference Sievänen, H., Koskue, V., Rauhio, A., et al., Peripheral quantitative computed tomography in human long bones. Evaluation of in vitro and in vivo precision. J. Bone Miner. Res. 13:871–882, 1998.CrossRef Sievänen, H., Koskue, V., Rauhio, A., et al., Peripheral quantitative computed tomography in human long bones. Evaluation of in vitro and in vivo precision. J. Bone Miner. Res. 13:871–882, 1998.CrossRef
9.
go back to reference Malek, M. M., DeLuca, J. V., Verch, D. L., et al., Arthroscopically assisted ACL reconstruction using central third patellar tendon autograft with press fit femoral fixation. Instr. Course Lect. 45:287–295, 1996. Malek, M. M., DeLuca, J. V., Verch, D. L., et al., Arthroscopically assisted ACL reconstruction using central third patellar tendon autograft with press fit femoral fixation. Instr. Course Lect. 45:287–295, 1996.
10.
go back to reference Brand, J., Weiler, A., Caborn, D. N. M., et al., Graft fixation issues in knee ligament surgery. Oper. Tech. Orthop. 9:256–263, 1999.CrossRef Brand, J., Weiler, A., Caborn, D. N. M., et al., Graft fixation issues in knee ligament surgery. Oper. Tech. Orthop. 9:256–263, 1999.CrossRef
11.
go back to reference Pena, F., Grontvedt, T., Brown, G. A., Aune, A. K., and Engebretsen, L., Comparisonof failure strength between metallic and absorbable interferencescrews. Influence of insertion torque, tunnel-bone block gap, bone mineraldensity, and interference. Am. J. Sports Med. 24:329–334, 1996.CrossRef Pena, F., Grontvedt, T., Brown, G. A., Aune, A. K., and Engebretsen, L., Comparisonof failure strength between metallic and absorbable interferencescrews. Influence of insertion torque, tunnel-bone block gap, bone mineraldensity, and interference. Am. J. Sports Med. 24:329–334, 1996.CrossRef
12.
go back to reference Clark, R., Olsen, R. E., Larson, B. J., et al., Cross pin femoral fixation: a new technique for hamstring anterior cruciate ligament reconstruction of the knee. Arthroscopy 14:258–267, 1998.CrossRef Clark, R., Olsen, R. E., Larson, B. J., et al., Cross pin femoral fixation: a new technique for hamstring anterior cruciate ligament reconstruction of the knee. Arthroscopy 14:258–267, 1998.CrossRef
13.
go back to reference Kousa, P., Järvinen, T. L. N., Vihavainen, M., et al., The fixation strength of six different hamstring graft fixation devices in anterior cruciate ligament reconstruction. Part I, Femoral site. Am. J. Sports Med. 31:174–181, 2003. Kousa, P., Järvinen, T. L. N., Vihavainen, M., et al., The fixation strength of six different hamstring graft fixation devices in anterior cruciate ligament reconstruction. Part I, Femoral site. Am. J. Sports Med. 31:174–181, 2003.
14.
go back to reference Kousa, P., Järvinen, T. L. N., Vihavainen, M., et al., The fixation strength of six different hamstring graft fixation devices in anterior cruciate ligament reconstruction. Part II, Tibial site. Am. J. Sports Med. 31:182–188, 2003. Kousa, P., Järvinen, T. L. N., Vihavainen, M., et al., The fixation strength of six different hamstring graft fixation devices in anterior cruciate ligament reconstruction. Part II, Tibial site. Am. J. Sports Med. 31:182–188, 2003.
15.
go back to reference Magen, H. E., Howell, S. M., and Hull, M. L., Structural properties of six tibial fixation methods for anterior cruciate ligament soft tissue grafts. Am. J. Sports Med. 27:35–43, 1999. Magen, H. E., Howell, S. M., and Hull, M. L., Structural properties of six tibial fixation methods for anterior cruciate ligament soft tissue grafts. Am. J. Sports Med. 27:35–43, 1999.
16.
go back to reference Weiler, A., Hoffmann, R. F. G., Stähelin, A. C., et al., Hamstring tendon fixation using interference screws: a biomechanical study in calf tibial bone. Arthroscopy 14:29–37, 1998.CrossRef Weiler, A., Hoffmann, R. F. G., Stähelin, A. C., et al., Hamstring tendon fixation using interference screws: a biomechanical study in calf tibial bone. Arthroscopy 14:29–37, 1998.CrossRef
17.
go back to reference DeLay, B. S., Smolinski, R. J., Wind, W. M., et al., Current practices and opinions in ACL reconstruction and rehabilitation. Results of a survey of the American Orthopaedic Society for Sports Medicine. Am. J. Knee Surg. 14:85–91, 2001. DeLay, B. S., Smolinski, R. J., Wind, W. M., et al., Current practices and opinions in ACL reconstruction and rehabilitation. Results of a survey of the American Orthopaedic Society for Sports Medicine. Am. J. Knee Surg. 14:85–91, 2001.
18.
go back to reference Harner, C. D., Fu, F. H., Irrgang, J. J., et al., Anterior and posterior cruciate ligament reconstruction in the new millennium. A global perspective. Knee Surg. Sports Traumatol. Arthrosc. 9:330–336, 2001.CrossRef Harner, C. D., Fu, F. H., Irrgang, J. J., et al., Anterior and posterior cruciate ligament reconstruction in the new millennium. A global perspective. Knee Surg. Sports Traumatol. Arthrosc. 9:330–336, 2001.CrossRef
20.
go back to reference Chizari, M., Wang, B., Snow, M., and Barrett, M., Experimental and numerical analysis of screw fixation in anterior cruciate ligament reconstruction. AIP Conf. Proc. 1045:61, 2008b, doi:10.1063/1.2991351. Chizari, M., Wang, B., Snow, M., and Barrett, M., Experimental and numerical analysis of screw fixation in anterior cruciate ligament reconstruction. AIP Conf. Proc. 1045:61, 2008b, doi:10.​1063/​1.​2991351.
21.
go back to reference Gérard, J. M., Ohayon, J., Luboz, V., Perrier, P., and Payan, Y., Indentation for estimating the human tongue soft tissues constitutive law: application to a 3D biomechanical model, Lecture Notes in Computer Science, vol. 3078. Springer, Berlin / Heidelberg, pp. 77–83, 2004. Gérard, J. M., Ohayon, J., Luboz, V., Perrier, P., and Payan, Y., Indentation for estimating the human tongue soft tissues constitutive law: application to a 3D biomechanical model, Lecture Notes in Computer Science, vol. 3078. Springer, Berlin / Heidelberg, pp. 77–83, 2004.
22.
go back to reference Treloar, L. R. G., The physics of rubber elasticity. Oxford University Press, London, 1958. Treloar, L. R. G., The physics of rubber elasticity. Oxford University Press, London, 1958.
23.
go back to reference Klute, G. K., and Hannaford, B., Fatigue characteristics of McKibben artificial muscle actuators. Proceedings, IEEE/RSJ 1998 International Conference on Intelligent Robotic Systems (IROS ’98), Victoria BC, Canada, Vol. 3, pp. 1776–1781, 1998. Klute, G. K., and Hannaford, B., Fatigue characteristics of McKibben artificial muscle actuators. Proceedings, IEEE/RSJ 1998 International Conference on Intelligent Robotic Systems (IROS ’98), Victoria BC, Canada, Vol. 3, pp. 1776–1781, 1998.
24.
go back to reference Gerard, J., Wilhelms-Tricarico, R., Perrier, P., and Payan, Y., A 3D dynamical biomechanical tongue model to study speech motor control. Recent Res. Dev. Biomech. 1:49–64, 2003. Gerard, J., Wilhelms-Tricarico, R., Perrier, P., and Payan, Y., A 3D dynamical biomechanical tongue model to study speech motor control. Recent Res. Dev. Biomech. 1:49–64, 2003.
25.
go back to reference Chabanas, M., Payan, Y., Marecaux, C., Swider, P., Boutault, F., Comparison of linear and non-linear soft tissue models with post-operative CT scan in maxillofacial surgery. International Symposium on Medical Simulation, Cambridge, Massachusetts, Vol. 3078, 19–27, 2004. Chabanas, M., Payan, Y., Marecaux, C., Swider, P., Boutault, F., Comparison of linear and non-linear soft tissue models with post-operative CT scan in maxillofacial surgery. International Symposium on Medical Simulation, Cambridge, Massachusetts, Vol. 3078, 19–27, 2004.
26.
go back to reference Black, K. P., Saunders, M. M., Stube, K. C., et al., Effects of interference fit screw length on tibial tunnel fixation for anterior cruciate ligament reconstruction. Am. J. Sports Med. 28:846–849, 2000. Black, K. P., Saunders, M. M., Stube, K. C., et al., Effects of interference fit screw length on tibial tunnel fixation for anterior cruciate ligament reconstruction. Am. J. Sports Med. 28:846–849, 2000.
27.
go back to reference Ishibashi, Y., Rudy, T. W., Livesay, G. A., et al., The effect of anterior cruciate ligament graft fixation site at the tibia on knee stability, evaluation using a robotic testing system. Arthroscopy 13:177–182, 1997.CrossRef Ishibashi, Y., Rudy, T. W., Livesay, G. A., et al., The effect of anterior cruciate ligament graft fixation site at the tibia on knee stability, evaluation using a robotic testing system. Arthroscopy 13:177–182, 1997.CrossRef
28.
go back to reference Miyata, K., Yasuda, K., Kondo, E., et al., Biomechanical comparisons of anterior cruciate ligament, reconstruction procedures with flexor tendon graft. J. Orthop. Sci. 5:585–592, 2000.CrossRef Miyata, K., Yasuda, K., Kondo, E., et al., Biomechanical comparisons of anterior cruciate ligament, reconstruction procedures with flexor tendon graft. J. Orthop. Sci. 5:585–592, 2000.CrossRef
29.
go back to reference Nagarkatti, D. G., McKeon, B. P., Donahue, B. S., et al., Mechanical evaluation of a soft tissue interference screw in free tendon anterior cruciate ligament graft fixation. Am. J. Sports Med. 29:67–71, 2001. Nagarkatti, D. G., McKeon, B. P., Donahue, B. S., et al., Mechanical evaluation of a soft tissue interference screw in free tendon anterior cruciate ligament graft fixation. Am. J. Sports Med. 29:67–71, 2001.
30.
go back to reference Rupp, S., Seil, R., Schneider, A., et al., Ligament graft initial fixation strength using biodegradable interference screws. J. Biomed. Mater. Res. 48:70–74, 1999.CrossRef Rupp, S., Seil, R., Schneider, A., et al., Ligament graft initial fixation strength using biodegradable interference screws. J. Biomed. Mater. Res. 48:70–74, 1999.CrossRef
Metadata
Title
Post-Operative Assessment of an Implant Fixation in Anterior Cruciate Ligament Reconstructive Surgery
Authors
Mahmoud Chizari
Martyn Snow
Bin Wang
Publication date
01-10-2011
Publisher
Springer US
Published in
Journal of Medical Systems / Issue 5/2011
Print ISSN: 0148-5598
Electronic ISSN: 1573-689X
DOI
https://doi.org/10.1007/s10916-010-9514-z

Other articles of this Issue 5/2011

Journal of Medical Systems 5/2011 Go to the issue