Skip to main content
Top
Published in: Journal of Clinical Monitoring and Computing 4/2021

01-08-2021 | Shock | Original Research

Performance of closed-loop resuscitation in a pig model of haemorrhagic shock with fluid alone or in combination with norepinephrine, a pilot study

Authors: Nicolas Libert, Guillaume Chenegros, Anatole Harrois, Nathalie Baudry, Benoit Decante, Gilles Cordurie, Ryad Benosman, Olaf Mercier, Eric Vicaut, Jacques Duranteau

Published in: Journal of Clinical Monitoring and Computing | Issue 4/2021

Login to get access

Abstract

We evaluated the performance of a new device to control the administration of fluid alone or co-administration of fluid and norepinephrine in a pig model of haemorrhagic shock in two sets of experiments. In the first one, resuscitation was guided using continuous arterial pressure measurements (three groups: resuscitation with fluid by a physician, CL resuscitation with fluid, and CL resuscitation with fluid and norepinephrine). In the second one, resuscitation was guided using discontinuous arterial pressure measurements (three groups: CL resuscitation with fluid alone, CL resuscitation with fluid and moderate dose norepinephrine, and CL resuscitation with fluid and a high dose of norepinephrine). Pigs were resuscitated for 1 h. In the first set of experiments, proportion of time spent in the target area of 78–88 mmHg of systolic arterial pressure was not statistically different between the three groups: manual, 71.2% (39.1–80.1); CL with fluid, 87.8% (68.3–97.4); and CL with fluid and norepinephrine, 78.1% (59.2–83.6), p = 0.151. In the second set of experiments, performance of CL resuscitation with fluid or with combination of fluid and high or moderate dose of norepinephrine was not significantly different (p = 0.543 for time in target). Pigs resuscitated with norepinephrine required less fluid and had less haemodilution than pigs resuscitated with fluid alone. Performance of CL resuscitation using continuous arterial pressure measurement was not significantly different than optimised manual treatment by a dedicated physician. Performance of CL resuscitation was reduced with discontinuous arterial pressure measurements in comparison with continuous arterial pressure measurements.
Appendix
Available only for authorised users
Literature
1.
go back to reference Rossaint R, Bouillon B, Cerny V, Coats TJ, Duranteau J, Fernandez-Mondejar E, et al. The European guideline on management of major bleeding and coagulopathy following trauma: fourth edition. Crit Care. 2016;20:100.CrossRef Rossaint R, Bouillon B, Cerny V, Coats TJ, Duranteau J, Fernandez-Mondejar E, et al. The European guideline on management of major bleeding and coagulopathy following trauma: fourth edition. Crit Care. 2016;20:100.CrossRef
2.
go back to reference Kramer GC, Kinsky MP, Prough DS, Salinas J, Sondeen JL, Hazel-Scerbo ML, et al. Closed-loop control of fluid therapy for treatment of hypovolemia. J Trauma. 2008;64(4 Suppl):S333–S34141.PubMed Kramer GC, Kinsky MP, Prough DS, Salinas J, Sondeen JL, Hazel-Scerbo ML, et al. Closed-loop control of fluid therapy for treatment of hypovolemia. J Trauma. 2008;64(4 Suppl):S333–S34141.PubMed
3.
go back to reference Salinas J, Chung KK, Mann EA, Cancio LC, Kramer GC, Serio-Melvin ML, et al. Computerized decision support system improves fluid resuscitation following severe burns: an original study. Crit Care Med. 2011;39(9):2031–8.CrossRef Salinas J, Chung KK, Mann EA, Cancio LC, Kramer GC, Serio-Melvin ML, et al. Computerized decision support system improves fluid resuscitation following severe burns: an original study. Crit Care Med. 2011;39(9):2031–8.CrossRef
4.
go back to reference Ying H, Bonnerup C, Kirschner R, Deyo D, Michell M, Kramer G (2002) (eds) Closed-loop fuzzy control of resuscitation of hemorrhagic shock in sheep. Engineering in Medicine and Biology, 2002 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society EMBS/BMES Conference, 2002 Proceedings of the Second Joint; 2002: IEEE. Ying H, Bonnerup C, Kirschner R, Deyo D, Michell M, Kramer G (2002) (eds) Closed-loop fuzzy control of resuscitation of hemorrhagic shock in sheep. Engineering in Medicine and Biology, 2002 24th Annual Conference and the Annual Fall Meeting of the Biomedical Engineering Society EMBS/BMES Conference, 2002 Proceedings of the Second Joint; 2002: IEEE.
5.
go back to reference Joosten A, Alexander B, Duranteau J, Taccone FS, Creteur J, Vincent JL, et al. Feasibility of closed-loop titration of norepinephrine infusion in patients undergoing moderate- and high-risk surgery. Br J Anaesth. 2019;123(4):430–8.CrossRef Joosten A, Alexander B, Duranteau J, Taccone FS, Creteur J, Vincent JL, et al. Feasibility of closed-loop titration of norepinephrine infusion in patients undergoing moderate- and high-risk surgery. Br J Anaesth. 2019;123(4):430–8.CrossRef
6.
go back to reference Joosten A, Delaporte A, Alexander B, Su F, Creteur J, Vincent JL, et al. Automated titration of vasopressor infusion using a closed-loop controller: in vivo feasibility study using a swine model. Anesthesiology. 2019;130(3):394–403.CrossRef Joosten A, Delaporte A, Alexander B, Su F, Creteur J, Vincent JL, et al. Automated titration of vasopressor infusion using a closed-loop controller: in vivo feasibility study using a swine model. Anesthesiology. 2019;130(3):394–403.CrossRef
7.
go back to reference Rinehart J, Joosten A, Ma M, Calderon MD, Cannesson M. Closed-loop vasopressor control: in-silico study of robustness against pharmacodynamic variability. J Clin Monit Comput. 2019;33(5):795–802.CrossRef Rinehart J, Joosten A, Ma M, Calderon MD, Cannesson M. Closed-loop vasopressor control: in-silico study of robustness against pharmacodynamic variability. J Clin Monit Comput. 2019;33(5):795–802.CrossRef
8.
go back to reference Rinehart J, Lee C, Canales C, Kong A, Kain Z, Cannesson M. Closed-loop fluid administration compared to anesthesiologist management for hemodynamic optimization and resuscitation during surgery: an in vivo study. Anesth Analg. 2013;117(5):1119–29.CrossRef Rinehart J, Lee C, Canales C, Kong A, Kain Z, Cannesson M. Closed-loop fluid administration compared to anesthesiologist management for hemodynamic optimization and resuscitation during surgery: an in vivo study. Anesth Analg. 2013;117(5):1119–29.CrossRef
9.
go back to reference Marques NR, Whitehead WE, Kallu UR, Kinsky MP, Funston JS, Wassar T, et al. Physician-directed versus computerized closed-loop control of blood pressure using phenylephrine in a Swine model. Anesth Analg. 2017;125(1):110–6.CrossRef Marques NR, Whitehead WE, Kallu UR, Kinsky MP, Funston JS, Wassar T, et al. Physician-directed versus computerized closed-loop control of blood pressure using phenylephrine in a Swine model. Anesth Analg. 2017;125(1):110–6.CrossRef
10.
go back to reference Michard F, Alaya S, Zarka V, Bahloul M, Richard C, Teboul JL. Global end-diastolic volume as an indicator of cardiac preload in patients with septic shock. Chest. 2003;124(5):1900–8.CrossRef Michard F, Alaya S, Zarka V, Bahloul M, Richard C, Teboul JL. Global end-diastolic volume as an indicator of cardiac preload in patients with septic shock. Chest. 2003;124(5):1900–8.CrossRef
11.
go back to reference Hofer CK, Furrer L, Matter-Ensner S, Maloigne M, Klaghofer R, Genoni M, et al. Volumetric preload measurement by thermodilution: a comparison with transoesophageal echocardiography. Br J Anaesth. 2005;94(6):748–55.CrossRef Hofer CK, Furrer L, Matter-Ensner S, Maloigne M, Klaghofer R, Genoni M, et al. Volumetric preload measurement by thermodilution: a comparison with transoesophageal echocardiography. Br J Anaesth. 2005;94(6):748–55.CrossRef
12.
go back to reference Wiggers CJ. The present status of the shock problem. Physiol Rev. 1942;22:74–123.CrossRef Wiggers CJ. The present status of the shock problem. Physiol Rev. 1942;22:74–123.CrossRef
13.
go back to reference Daye P, Ieng SH, Benosman R. A Theory for sparse event-based closed loop control. Front Neurosci. 2019;13:827.CrossRef Daye P, Ieng SH, Benosman R. A Theory for sparse event-based closed loop control. Front Neurosci. 2019;13:827.CrossRef
14.
go back to reference Libert N, Chenegros G, Harrois A, Baudry N, Cordurie G, Benosman R, et al. Performance of closed-loop resuscitation of haemorrhagic shock with fluid alone or in combination with norepinephrine: an experimental study. Ann Intensive Care. 2018;8(1):89.CrossRef Libert N, Chenegros G, Harrois A, Baudry N, Cordurie G, Benosman R, et al. Performance of closed-loop resuscitation of haemorrhagic shock with fluid alone or in combination with norepinephrine: an experimental study. Ann Intensive Care. 2018;8(1):89.CrossRef
15.
go back to reference Chaisson NF, Kirschner RA, Deyo DJ, Lopez JA, Prough DS, Kramer GC. Near-infrared spectroscopy-guided closed-loop resuscitation of hemorrhage. J Trauma. 2003;54(5 Suppl):S183–S192192.PubMed Chaisson NF, Kirschner RA, Deyo DJ, Lopez JA, Prough DS, Kramer GC. Near-infrared spectroscopy-guided closed-loop resuscitation of hemorrhage. J Trauma. 2003;54(5 Suppl):S183–S192192.PubMed
16.
go back to reference Rafie AD, Rath PA, Michell MW, Kirschner RA, Deyo DJ, Prough DS, et al. Hypotensive resuscitation of multiple hemorrhages using crystalloid and colloids. Shock. 2004;22(3):262–9.CrossRef Rafie AD, Rath PA, Michell MW, Kirschner RA, Deyo DJ, Prough DS, et al. Hypotensive resuscitation of multiple hemorrhages using crystalloid and colloids. Shock. 2004;22(3):262–9.CrossRef
17.
go back to reference Do Nascimento P Jr, Vaid SU, Hoskins SL, Espana JM, Kinsky MP, Kramer GC. Hypertonic 15% sodium pyruvate offers no initial resuscitation advantage compared with 8% hypertonic NACl in sheep with multiple hemorrhages. Shock. 2007;27(5):565–71.CrossRef Do Nascimento P Jr, Vaid SU, Hoskins SL, Espana JM, Kinsky MP, Kramer GC. Hypertonic 15% sodium pyruvate offers no initial resuscitation advantage compared with 8% hypertonic NACl in sheep with multiple hemorrhages. Shock. 2007;27(5):565–71.CrossRef
18.
go back to reference Vaid SU, Shah A, Michell MW, Rafie AD, Deyo DJ, Prough DS, et al. Normotensive and hypotensive closed-loop resuscitation using 3.0% NaCl to treat multiple hemorrhages in sheep. Crit Care Med. 2006;34(4):1185–92.CrossRef Vaid SU, Shah A, Michell MW, Rafie AD, Deyo DJ, Prough DS, et al. Normotensive and hypotensive closed-loop resuscitation using 3.0% NaCl to treat multiple hemorrhages in sheep. Crit Care Med. 2006;34(4):1185–92.CrossRef
19.
go back to reference Marques NR, Ford BJ, Khan MN, Kinsky M, Deyo DJ, Mileski WJ, et al. Automated closed-loop resuscitation of multiple hemorrhages: a comparison between fuzzy logic and decision table controllers in a sheep model. Disaster Mil Med. 2017;3:1.CrossRef Marques NR, Ford BJ, Khan MN, Kinsky M, Deyo DJ, Mileski WJ, et al. Automated closed-loop resuscitation of multiple hemorrhages: a comparison between fuzzy logic and decision table controllers in a sheep model. Disaster Mil Med. 2017;3:1.CrossRef
20.
go back to reference Varvel JR, Donoho DL, Shafer SL. Measuring the predictive performance of computer-controlled infusion pumps. J Pharmacokinet Biopharm. 1992;20(1):63–94.CrossRef Varvel JR, Donoho DL, Shafer SL. Measuring the predictive performance of computer-controlled infusion pumps. J Pharmacokinet Biopharm. 1992;20(1):63–94.CrossRef
21.
go back to reference Sng BL, Wang H, Assam PN, Sia AT. Assessment of an updated double-vasopressor automated system using Nexfin for the maintenance of haemodynamic stability to improve peri-operative outcome during spinal anaesthesia for caesarean section. Anaesthesia. 2015;70(6):691–8.CrossRef Sng BL, Wang H, Assam PN, Sia AT. Assessment of an updated double-vasopressor automated system using Nexfin for the maintenance of haemodynamic stability to improve peri-operative outcome during spinal anaesthesia for caesarean section. Anaesthesia. 2015;70(6):691–8.CrossRef
22.
go back to reference Ngan Kee WD, Khaw KS, Tam YH, Ng FF, Lee SW. Performance of a closed-loop feedback computer-controlled infusion system for maintaining blood pressure during spinal anaesthesia for caesarean section: a randomized controlled comparison of norepinephrine versus phenylephrine. J Clin Monit Comput. 2017;31(3):617–23.CrossRef Ngan Kee WD, Khaw KS, Tam YH, Ng FF, Lee SW. Performance of a closed-loop feedback computer-controlled infusion system for maintaining blood pressure during spinal anaesthesia for caesarean section: a randomized controlled comparison of norepinephrine versus phenylephrine. J Clin Monit Comput. 2017;31(3):617–23.CrossRef
23.
go back to reference Ngan Kee WD, Tam YH, Khaw KS, Ng FF, Critchley LA, Karmakar MK. Closed-loop feedback computer-controlled infusion of phenylephrine for maintaining blood pressure during spinal anaesthesia for caesarean section: a preliminary descriptive study. Anaesthesia. 2007;62(12):1251–6.CrossRef Ngan Kee WD, Tam YH, Khaw KS, Ng FF, Critchley LA, Karmakar MK. Closed-loop feedback computer-controlled infusion of phenylephrine for maintaining blood pressure during spinal anaesthesia for caesarean section: a preliminary descriptive study. Anaesthesia. 2007;62(12):1251–6.CrossRef
24.
go back to reference Kashihara K, Kawada T, Uemura K, Sugimachi M, Sunagawa K. Adaptive predictive control of arterial blood pressure based on a neural network during acute hypotension. Ann Biomed Eng. 2004;32(10):1365–83.CrossRef Kashihara K, Kawada T, Uemura K, Sugimachi M, Sunagawa K. Adaptive predictive control of arterial blood pressure based on a neural network during acute hypotension. Ann Biomed Eng. 2004;32(10):1365–83.CrossRef
25.
go back to reference Uemura K, Kawada T, Zheng C, Li M, Sugimachi M. Computer-controlled closed-loop drug infusion system for automated hemodynamic resuscitation in endotoxin-induced shock. BMC Anesthesiol. 2017;17(1):145.CrossRef Uemura K, Kawada T, Zheng C, Li M, Sugimachi M. Computer-controlled closed-loop drug infusion system for automated hemodynamic resuscitation in endotoxin-induced shock. BMC Anesthesiol. 2017;17(1):145.CrossRef
Metadata
Title
Performance of closed-loop resuscitation in a pig model of haemorrhagic shock with fluid alone or in combination with norepinephrine, a pilot study
Authors
Nicolas Libert
Guillaume Chenegros
Anatole Harrois
Nathalie Baudry
Benoit Decante
Gilles Cordurie
Ryad Benosman
Olaf Mercier
Eric Vicaut
Jacques Duranteau
Publication date
01-08-2021
Publisher
Springer Netherlands
Keywords
Shock
Shock
Published in
Journal of Clinical Monitoring and Computing / Issue 4/2021
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-020-00542-7

Other articles of this Issue 4/2021