Skip to main content
Top
Published in: Journal of Clinical Monitoring and Computing 4/2020

01-08-2020 | Ear Surgery | Original Research

A new device for real-time peroperative monitoring of ossicular chain reconstruction during middle ear surgery

Published in: Journal of Clinical Monitoring and Computing | Issue 4/2020

Login to get access

Abstract

To limit functional surgical failure and reduce the rate of revision surgery in case of surgical ossicular chain reconstruction, a piezoelectric device was developed for assessment of ossicular chain vibrations during the middle ear surgery. The device resembled a pen and consisted of a reusable main body and a disposable sensitive head including piezoelectric polymer sensor. Almost all of components of the device were made of polymer for light weight and for acoustic impedance matching to the middle ear system. Several frequencies can be analyzed simultaneously and several measures can be taken by time. The results showed that the device can record normal and reconstructed ossicular chain vibration in response to an acoustic stimulation, with similar results to those achieved by laser Doppler vibrometer. This light, handheld and low-cost device allows fast, easy and safe assessments of normal ossicular chain mobility and ossicular chain reconstruction efficiency. Primary pre-clinical trial showed very promising performance of the device that could be used to qualitatively control ossiculoplasty during real-time surgical procedure. Clinical assessments will be done to further evaluate the real-life performance of the device.
Appendix
Available only for authorised users
Literature
1.
go back to reference Black B. Reporting results in ossiculoplasty. Otol Neurotol. 2003;24:534–42.CrossRef Black B. Reporting results in ossiculoplasty. Otol Neurotol. 2003;24:534–42.CrossRef
2.
go back to reference Zhang L-C, Zhang T-Y, Dai P, Luo J. Titanium versus non-titanium prostheses in ossiculoplasty: a meta-analysis. Acta Otolaryngol (Stockh). 2011;131:708–15.CrossRef Zhang L-C, Zhang T-Y, Dai P, Luo J. Titanium versus non-titanium prostheses in ossiculoplasty: a meta-analysis. Acta Otolaryngol (Stockh). 2011;131:708–15.CrossRef
3.
go back to reference Wazen JJ, Emerson R, Foyt D. Intra-operative electrocochleography in stapedectomy and ossicular reconstruction. Am J Otol. 1997;18:707–13.PubMed Wazen JJ, Emerson R, Foyt D. Intra-operative electrocochleography in stapedectomy and ossicular reconstruction. Am J Otol. 1997;18:707–13.PubMed
4.
go back to reference Selesnick SH, Victor JD, Tikoo RK, Eisenman DJ. Predictive value of intraoperative brainstem auditory evoked responses in surgery for conductive hearing losses. Am J Otol. 1997;18:2–9.CrossRef Selesnick SH, Victor JD, Tikoo RK, Eisenman DJ. Predictive value of intraoperative brainstem auditory evoked responses in surgery for conductive hearing losses. Am J Otol. 1997;18:2–9.CrossRef
5.
go back to reference Hsu GS. Improving hearing in stapedectomy with intraoperative auditory brainstem response. Otolaryngol—Head Neck Surg. 2011;144:60–3.CrossRef Hsu GS. Improving hearing in stapedectomy with intraoperative auditory brainstem response. Otolaryngol—Head Neck Surg. 2011;144:60–3.CrossRef
6.
go back to reference Ren W, Ji F, Zeng J, Zhao H. Intra-operative hearing monitoring methods in middle ear surgeries. J Otol. 2016;11:178–84.CrossRef Ren W, Ji F, Zeng J, Zhao H. Intra-operative hearing monitoring methods in middle ear surgeries. J Otol. 2016;11:178–84.CrossRef
7.
go back to reference Filipo R, Attanasio G, Barbaro M, Viccaro M, Musacchio A, Cappelli G, et al. Distortion product otoacoustic emissions in otosclerosis: intraoperative findings. Adv Otorhinolaryngol. 2007;65:133–6.PubMed Filipo R, Attanasio G, Barbaro M, Viccaro M, Musacchio A, Cappelli G, et al. Distortion product otoacoustic emissions in otosclerosis: intraoperative findings. Adv Otorhinolaryngol. 2007;65:133–6.PubMed
8.
go back to reference Rosowski JJ, Nakajima HH, Merchant SN. Clinical utility of laser-doppler vibrometer measurements in live normal and pathologic human ears. Ear Hear. 2008;29:3–19.PubMedPubMedCentral Rosowski JJ, Nakajima HH, Merchant SN. Clinical utility of laser-doppler vibrometer measurements in live normal and pathologic human ears. Ear Hear. 2008;29:3–19.PubMedPubMedCentral
9.
go back to reference Beyea JA, Rohani SA, Ladak HM, Agrawal SK. Laser Doppler Vibrometry measurements of human cadaveric tympanic membrane vibration. J Otolaryngol—Head Neck Surg. 2013;42:17.CrossRef Beyea JA, Rohani SA, Ladak HM, Agrawal SK. Laser Doppler Vibrometry measurements of human cadaveric tympanic membrane vibration. J Otolaryngol—Head Neck Surg. 2013;42:17.CrossRef
11.
go back to reference Gyo K, Aritomo H, Goode RL. Measurement of the ossicular vibration ratio in human temporal bones by use of a video measuring system. Acta Otolaryngol (Stockh). 1987;103:87–95.CrossRef Gyo K, Aritomo H, Goode RL. Measurement of the ossicular vibration ratio in human temporal bones by use of a video measuring system. Acta Otolaryngol (Stockh). 1987;103:87–95.CrossRef
12.
go back to reference Gyo K, Yumoto E, Sato H, Yanagihara N. Assessment of stapes mobility by use of a newly developed piezoelectric ceramic device a preliminary experiment in dogs. Ann Otol Rhinol Laryngol. 2000;109:473–7.CrossRef Gyo K, Yumoto E, Sato H, Yanagihara N. Assessment of stapes mobility by use of a newly developed piezoelectric ceramic device a preliminary experiment in dogs. Ann Otol Rhinol Laryngol. 2000;109:473–7.CrossRef
13.
go back to reference Wada H, Koike T, Yuasa Y, Kawase T, Fujii H. Measurement of stapes mobility in guinea pigs and rabbits. Hear Res. 2001;154:158–64.CrossRef Wada H, Koike T, Yuasa Y, Kawase T, Fujii H. Measurement of stapes mobility in guinea pigs and rabbits. Hear Res. 2001;154:158–64.CrossRef
14.
go back to reference Hato N, Kohno H, Okada M, Hakuba N, Gyo K, Iwakura T, et al. A new tool for testing ossicular mobility during middle ear surgery: preliminary report of four cases. Otol Neurotol. 2006;27:592–5.CrossRef Hato N, Kohno H, Okada M, Hakuba N, Gyo K, Iwakura T, et al. A new tool for testing ossicular mobility during middle ear surgery: preliminary report of four cases. Otol Neurotol. 2006;27:592–5.CrossRef
15.
go back to reference Lynch TJ, Nedzelnitsky V, Peake WT. Input impedance of the cochlea in cat. J Acoust Soc Am. 1982;72:108–30.CrossRef Lynch TJ, Nedzelnitsky V, Peake WT. Input impedance of the cochlea in cat. J Acoust Soc Am. 1982;72:108–30.CrossRef
16.
go back to reference Gummer AW, Smolders JWT, Klinke R. Mechanics of a single-ossicle ear: I. The extra-stapedius of the pigeon. Hear Res. 1989;39:1–13.CrossRef Gummer AW, Smolders JWT, Klinke R. Mechanics of a single-ossicle ear: I. The extra-stapedius of the pigeon. Hear Res. 1989;39:1–13.CrossRef
17.
go back to reference Gununer AW, Smolders JWT, Klinke R. Mechanics of a single-ossicle ear: II. The columella footplate of the pigeon. Hear Res. 1989;39:15–25.CrossRef Gununer AW, Smolders JWT, Klinke R. Mechanics of a single-ossicle ear: II. The columella footplate of the pigeon. Hear Res. 1989;39:15–25.CrossRef
18.
go back to reference Ruggero MA, Rich NC, Robles L, Shivapuja BG. Middle-ear response in the chinchilla and its relationship to mechanics at the base of the cochlea. J Acoust Soc Am. 1990;87:1612–29.CrossRef Ruggero MA, Rich NC, Robles L, Shivapuja BG. Middle-ear response in the chinchilla and its relationship to mechanics at the base of the cochlea. J Acoust Soc Am. 1990;87:1612–29.CrossRef
19.
go back to reference Zirkl M, Sawatdee A, Helbig U, Krause M, Scheipl G, Kraker E, et al. An all-printed ferroelectric active matrix sensor network based on only five functional materials forming a touchless control interface. Adv Mater. 2011;23:2069–74.CrossRef Zirkl M, Sawatdee A, Helbig U, Krause M, Scheipl G, Kraker E, et al. An all-printed ferroelectric active matrix sensor network based on only five functional materials forming a touchless control interface. Adv Mater. 2011;23:2069–74.CrossRef
20.
go back to reference Nguyen V, Badie L, Sénéchault E, Blampain E, Vincent B, Venet C, et al. Flexible over-moded resonators based on P(VDF-TrFE) thin films with very high temperature coefficient. IEEE Trans Ultrason Ferroelectr Freq Control. 2013;60:2039–43.CrossRef Nguyen V, Badie L, Sénéchault E, Blampain E, Vincent B, Venet C, et al. Flexible over-moded resonators based on P(VDF-TrFE) thin films with very high temperature coefficient. IEEE Trans Ultrason Ferroelectr Freq Control. 2013;60:2039–43.CrossRef
21.
go back to reference Strashilov V, Alexieva G, Vincent B, Nguyen VS, Rouxel D. Structural impact on piezoelectricity in PVDF and P(VDF-TrFE) thin films. Appl Phys A. 2014;118:1469–77.CrossRef Strashilov V, Alexieva G, Vincent B, Nguyen VS, Rouxel D. Structural impact on piezoelectricity in PVDF and P(VDF-TrFE) thin films. Appl Phys A. 2014;118:1469–77.CrossRef
23.
go back to reference Morris DP, Bance M, van Wijhe RG, Kiefte M, Smith R. Optimum tension for partial ossicular replacement prosthesis reconstruction in the human middle ear. Laryngoscope. 2004;114:305–8.CrossRef Morris DP, Bance M, van Wijhe RG, Kiefte M, Smith R. Optimum tension for partial ossicular replacement prosthesis reconstruction in the human middle ear. Laryngoscope. 2004;114:305–8.CrossRef
24.
go back to reference Bance M, Morris DP, Van Wijhe R. Effects of ossicular prosthesis mass and section of the stapes tendon on middle ear transmission. J Otolaryngol. 2007;36:113.CrossRef Bance M, Morris DP, Van Wijhe R. Effects of ossicular prosthesis mass and section of the stapes tendon on middle ear transmission. J Otolaryngol. 2007;36:113.CrossRef
25.
go back to reference Bance M, Campos A, Wong L, Morris DP, van Wijhe R. How does prosthesis head size affect vibration transmission in ossiculoplasty? Otolaryngol—Head Neck Surg. 2007;137:70–3.CrossRef Bance M, Campos A, Wong L, Morris DP, van Wijhe R. How does prosthesis head size affect vibration transmission in ossiculoplasty? Otolaryngol—Head Neck Surg. 2007;137:70–3.CrossRef
Metadata
Title
A new device for real-time peroperative monitoring of ossicular chain reconstruction during middle ear surgery
Publication date
01-08-2020
Keywords
Ear Surgery
Laser
Published in
Journal of Clinical Monitoring and Computing / Issue 4/2020
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-019-00364-2

Other articles of this Issue 4/2020

Journal of Clinical Monitoring and Computing 4/2020 Go to the issue