Abstract

Hemodynamic management is a mainstay of patient care in the operating room and intensive care unit (ICU). In order to optimize patient treatment, researchers investigate monitoring technologies, cardiovascular (patho-) physiology, and hemodynamic treatment strategies. The Journal of Clinical Monitoring and Computing (JCMC) is a well-established and recognized platform for publishing research in this field. In this review, we highlight recent advancements and summarize selected papers published in the JCMC in 2018 related to hemodynamic monitoring and management.
Literature
6.
go back to reference Langwieser N, Prechtl L, Meidert AS, Hapfelmeier A, Bradaric C, Ibrahim T, Laugwitz KL, Schmid RM, Wagner JY, Saugel B. Radial artery applanation tonometry for continuous noninvasive arterial blood pressure monitoring in the cardiac intensive care unit. Clin Res Cardiol. 2015;104(6):518–24. https://doi.org/10.1007/s00392-015-0816-5.CrossRefPubMed Langwieser N, Prechtl L, Meidert AS, Hapfelmeier A, Bradaric C, Ibrahim T, Laugwitz KL, Schmid RM, Wagner JY, Saugel B. Radial artery applanation tonometry for continuous noninvasive arterial blood pressure monitoring in the cardiac intensive care unit. Clin Res Cardiol. 2015;104(6):518–24. https://​doi.​org/​10.​1007/​s00392-015-0816-5.CrossRefPubMed
7.
go back to reference Meidert AS, Huber W, Muller JN, Schofthaler M, Hapfelmeier A, Langwieser N, Wagner JY, Eyer F, Schmid RM, Saugel B. Radial artery applanation tonometry for continuous non-invasive arterial pressure monitoring in intensive care unit patients: comparison with invasively assessed radial arterial pressure. Br J Anaesth. 2014;112(3):521–8. https://doi.org/10.1093/bja/aet400.CrossRefPubMed Meidert AS, Huber W, Muller JN, Schofthaler M, Hapfelmeier A, Langwieser N, Wagner JY, Eyer F, Schmid RM, Saugel B. Radial artery applanation tonometry for continuous non-invasive arterial pressure monitoring in intensive care unit patients: comparison with invasively assessed radial arterial pressure. Br J Anaesth. 2014;112(3):521–8. https://​doi.​org/​10.​1093/​bja/​aet400.CrossRefPubMed
11.
go back to reference Saugel B, Meidert AS, Hapfelmeier A, Eyer F, Schmid RM, Huber W. Non-invasive continuous arterial pressure measurement based on radial artery tonometry in the intensive care unit: a method comparison study using the T-Line TL-200pro device. Br J Anaesth. 2013;111(2):185–90. https://doi.org/10.1093/bja/aet025.CrossRefPubMed Saugel B, Meidert AS, Hapfelmeier A, Eyer F, Schmid RM, Huber W. Non-invasive continuous arterial pressure measurement based on radial artery tonometry in the intensive care unit: a method comparison study using the T-Line TL-200pro device. Br J Anaesth. 2013;111(2):185–90. https://​doi.​org/​10.​1093/​bja/​aet025.CrossRefPubMed
12.
go back to reference Wagner JY, Sarwari H, Schon G, Kubik M, Kluge S, Reichenspurner H, Reuter DA, Saugel B. Radial Artery Applanation Tonometry for Continuous Noninvasive Cardiac Output Measurement: A Comparison With Intermittent Pulmonary Artery Thermodilution in Patients After Cardiothoracic Surgery. Crit Care Med. 2015;43(7):1423–8. https://doi.org/10.1097/ccm.0000000000000979.CrossRefPubMed Wagner JY, Sarwari H, Schon G, Kubik M, Kluge S, Reichenspurner H, Reuter DA, Saugel B. Radial Artery Applanation Tonometry for Continuous Noninvasive Cardiac Output Measurement: A Comparison With Intermittent Pulmonary Artery Thermodilution in Patients After Cardiothoracic Surgery. Crit Care Med. 2015;43(7):1423–8. https://​doi.​org/​10.​1097/​ccm.​0000000000000979​.CrossRefPubMed
18.
go back to reference Wagner JY, Korner A, Schulte-Uentrop L, Kubik M, Reichenspurner H, Kluge S, Reuter DA, Saugel B. A comparison of volume clamp method-based continuous noninvasive cardiac output (CNCO) measurement versus intermittent pulmonary artery thermodilution in postoperative cardiothoracic surgery patients. J Clin Monit Comput. 2018;32(2):235–44. https://doi.org/10.1007/s10877-017-0027-x.CrossRefPubMed Wagner JY, Korner A, Schulte-Uentrop L, Kubik M, Reichenspurner H, Kluge S, Reuter DA, Saugel B. A comparison of volume clamp method-based continuous noninvasive cardiac output (CNCO) measurement versus intermittent pulmonary artery thermodilution in postoperative cardiothoracic surgery patients. J Clin Monit Comput. 2018;32(2):235–44. https://​doi.​org/​10.​1007/​s10877-017-0027-x.CrossRefPubMed
29.
36.
go back to reference Fujiwara SJL, Tachihara K, Mori S, Ouchi K, Itakura S, Yasuda M, Hitosugi T, Imaizumi U, Miki Y, Toyoguchi I, Yoshida KI, Yokoyama T. Influence of the marvelous three-way stopcock on the natural frequency and damping coefficient in blood pressure transducer kits. J Clin Monit Comput. 2018;32(1):63–72. https://doi.org/10.1007/s10877-017-9979-0.CrossRefPubMed Fujiwara SJL, Tachihara K, Mori S, Ouchi K, Itakura S, Yasuda M, Hitosugi T, Imaizumi U, Miki Y, Toyoguchi I, Yoshida KI, Yokoyama T. Influence of the marvelous three-way stopcock on the natural frequency and damping coefficient in blood pressure transducer kits. J Clin Monit Comput. 2018;32(1):63–72. https://​doi.​org/​10.​1007/​s10877-017-9979-0.CrossRefPubMed
41.
go back to reference Lilot M, Bellon A, Gueugnon M, Laplace MC, Baffeleuf B, Hacquard P, Barthomeuf F, Parent C, Tran T, Soubirou JL, Robinson P, Bouvet L, Vassal O, Lehot JJ, Piriou V. Comparison of cardiac output optimization with an automated closed-loop goal-directed fluid therapy versus non standardized manual fluid administration during elective abdominal surgery: first prospective randomized controlled trial. J Clin Monit Comput. 2018;32(6):993–1003. https://doi.org/10.1007/s10877-018-0106-7.CrossRefPubMed Lilot M, Bellon A, Gueugnon M, Laplace MC, Baffeleuf B, Hacquard P, Barthomeuf F, Parent C, Tran T, Soubirou JL, Robinson P, Bouvet L, Vassal O, Lehot JJ, Piriou V. Comparison of cardiac output optimization with an automated closed-loop goal-directed fluid therapy versus non standardized manual fluid administration during elective abdominal surgery: first prospective randomized controlled trial. J Clin Monit Comput. 2018;32(6):993–1003. https://​doi.​org/​10.​1007/​s10877-018-0106-7.CrossRefPubMed
45.
go back to reference Angus DC, Barnato AE, Bell D, Bellomo R, Chong CR, Coats TJ, Davies A, Delaney A, Harrison DA, Holdgate A, Howe B, Huang DT, Iwashyna T, Kellum JA, Peake SL, Pike F, Reade MC, Rowan KM, Singer M, Webb SA, Weissfeld LA, Yealy DM, Young JD. A systematic review and meta-analysis of early goal-directed therapy for septic shock: the ARISE, ProCESS and ProMISe Investigators. Intensive Care Med. 2015;41(9):1549–60. https://doi.org/10.1007/s00134-015-3822-1.CrossRefPubMed Angus DC, Barnato AE, Bell D, Bellomo R, Chong CR, Coats TJ, Davies A, Delaney A, Harrison DA, Holdgate A, Howe B, Huang DT, Iwashyna T, Kellum JA, Peake SL, Pike F, Reade MC, Rowan KM, Singer M, Webb SA, Weissfeld LA, Yealy DM, Young JD. A systematic review and meta-analysis of early goal-directed therapy for septic shock: the ARISE, ProCESS and ProMISe Investigators. Intensive Care Med. 2015;41(9):1549–60. https://​doi.​org/​10.​1007/​s00134-015-3822-1.CrossRefPubMed
51.
go back to reference Salmasi V, Maheshwari K, Yang D, Mascha EJ, Singh A, Sessler DI, Kurz A. Relationship between Intraoperative Hypotension, Defined by Either Reduction from Baseline or Absolute Thresholds, and Acute Kidney and Myocardial Injury after Noncardiac Surgery: A Retrospective Cohort Analysis. Anesthesiology. 2017;126(1):47–65. https://doi.org/10.1097/aln.0000000000001432.CrossRefPubMed Salmasi V, Maheshwari K, Yang D, Mascha EJ, Singh A, Sessler DI, Kurz A. Relationship between Intraoperative Hypotension, Defined by Either Reduction from Baseline or Absolute Thresholds, and Acute Kidney and Myocardial Injury after Noncardiac Surgery: A Retrospective Cohort Analysis. Anesthesiology. 2017;126(1):47–65. https://​doi.​org/​10.​1097/​aln.​0000000000001432​.CrossRefPubMed
Metadata
Title
Journal of clinical monitoring and computing end of year summary 2018: hemodynamic monitoring and management
Authors
Bernd Saugel
Moritz Flick
Karim Bendjelid
Lester A. H. Critchley
Simon T. Vistisen
Thomas W. L. Scheeren
Publication date
01-04-2019
Publisher
Springer Netherlands
Published in
Journal of Clinical Monitoring and Computing / Issue 2/2019
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-019-00297-w

Other articles of this Issue 2/2019

Journal of Clinical Monitoring and Computing 2/2019 Go to the issue

Review Paper

EOY summary 2018