Non-invasive real-time autonomic function characterization during surgery via continuous Poincaré quantification of heart rate variability

Authors: Maddalena Ardissino, Nicoletta Nicolaou, Marcela Vizcaychipi

Published in: Journal of Clinical Monitoring and Computing | Issue 4/2019

Login to get access

Abstract

Heart rate variability (HRV) provides an excellent proxy for monitoring of autonomic function, but the clinical utility of such characterization has not been investigated. In a clinical setting, the baseline autonomic function can reflect ability to adapt to stressors such as anesthesia. No monitoring tool has yet been developed that is able to track changes in HRV in real time. This study is a proof-of-concept for a non-invasive, real-time monitoring model for autonomic function via continuous Poincaré quantification of HRV dynamics. Anonymized heart rate data of 18 healthy individuals (18–45 years) undergoing minor procedures and 18 healthy controls (21–35 years) were analyzed. Patients underwent propofol and fentanyl anesthesia, and controls were at rest. Continuous heart rate monitoring was carried out from before aesthetic induction to the end of the surgical procedure. HRV components (sympathetic and parasympathetic) were extracted and analyzed using Poincaré quantification, and a real-time assessment tool was developed. In the patient group, a significant decrease in the sympathetic and parasympathetic components of HRV was observed following anesthesia (SD1: p = 0.019; SD2: p = 0.00027). No corresponding change in HRV was observed in controls. HRV parameters were modelled into a real-time graph. Using the monitoring technique developed, autonomic changes could be successfully visualized in real-time. This could provide the basis for a novel, fast and non-invasive method of autonomic assessment that can be delivered at the point of care.
Appendix
Available only for authorised users
Literature
7.
go back to reference Ebert T, Muzi M. Propofol and autonomic reflex function in humans. Anesth Analg. 1994;78(2):369–75.CrossRefPubMed Ebert T, Muzi M. Propofol and autonomic reflex function in humans. Anesth Analg. 1994;78(2):369–75.CrossRefPubMed
8.
go back to reference Hug CC Jr, McLeskey CH, Nahrwold ML, et al. Hemodynamic effects of propofol: data from over 25,000 patients. Anesth Analg. 1993;77(4 SUPPL.):21–9. Hug CC Jr, McLeskey CH, Nahrwold ML, et al. Hemodynamic effects of propofol: data from over 25,000 patients. Anesth Analg. 1993;77(4 SUPPL.):21–9.
15.
go back to reference Goldberger AL, Amaral LAN, Glass L, et al. PhysioBank, Physiotoolkit, and PhysioNet: components of a new research resource for complex physiologic signals. Circulation. 2000;101(23):e215–20.CrossRef Goldberger AL, Amaral LAN, Glass L, et al. PhysioBank, Physiotoolkit, and PhysioNet: components of a new research resource for complex physiologic signals. Circulation. 2000;101(23):e215–20.CrossRef
26.
go back to reference Jeyhani V, Mahdiani S, Peltokangas M, Vehkaoja A. Comparison of HRV parameters derived from photoplethysmography and electrocardiography signals. In: Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS. 2015 November; 2015:5952–5955. https://doi.org/10.1109/EMBC.2015.7319747. Jeyhani V, Mahdiani S, Peltokangas M, Vehkaoja A. Comparison of HRV parameters derived from photoplethysmography and electrocardiography signals. In: Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS. 2015 November; 2015:5952–5955. https://​doi.​org/​10.​1109/​EMBC.​2015.​7319747.
29.
go back to reference Mahdiani S, Jeyhani V, Peltokangas M, Vehkaoja A. Is 50 Hz high enough ECG sampling frequency for accurate HRV analysis? In: Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS. 2015 November; 2015:5948–5951. https://doi.org/10.1109/EMBC.2015.7319746. Mahdiani S, Jeyhani V, Peltokangas M, Vehkaoja A. Is 50 Hz high enough ECG sampling frequency for accurate HRV analysis? In: Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS. 2015 November; 2015:5948–5951. https://​doi.​org/​10.​1109/​EMBC.​2015.​7319746.
31.
go back to reference Ledowski T, Tiong WS, Lee C, Wong B, Fiori T, Parker N. Analgesia nociception index: evaluation as a new parameter for acute postoperative pain. BJA. 2013;111(4):627–9.CrossRefPubMed Ledowski T, Tiong WS, Lee C, Wong B, Fiori T, Parker N. Analgesia nociception index: evaluation as a new parameter for acute postoperative pain. BJA. 2013;111(4):627–9.CrossRefPubMed
32.
go back to reference Brouwer J, Van Veldhuisen DJ, In’t AJM et al. Prognostic value of heart rate variability during long-term follow-up in patients with mild to moderate heart failure. J Am Coll Cardiol. 1996;28(5):1183–9.CrossRefPubMed Brouwer J, Van Veldhuisen DJ, In’t AJM et al. Prognostic value of heart rate variability during long-term follow-up in patients with mild to moderate heart failure. J Am Coll Cardiol. 1996;28(5):1183–9.CrossRefPubMed
Metadata
Title
Non-invasive real-time autonomic function characterization during surgery via continuous Poincaré quantification of heart rate variability
Authors
Maddalena Ardissino
Nicoletta Nicolaou
Marcela Vizcaychipi
Publication date
01-08-2019
Publisher
Springer Netherlands
Published in
Journal of Clinical Monitoring and Computing / Issue 4/2019
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-018-0206-4

Other articles of this Issue 4/2019

Journal of Clinical Monitoring and Computing 4/2019 Go to the issue