A mainstream monitoring system for respiratory CO2 concentration and gasflow

Authors: Jiachen Yang, Bobo Chen, Kyle Burk, Haitao Wang, Jianxiong Zhou

Published in: Journal of Clinical Monitoring and Computing | Issue 4/2016

Login to get access

Abstract

Continuous respiratory gas monitoring is an important tool for clinical monitoring. In particular, measurement of respiratory \(\hbox {CO}_2\) concentration and gasflow can reflect the status of a patient by providing parameters such as volume of carbon dioxide, end-tidal \(\hbox {CO}_2,\) respiratory rate and alveolar deadspace. However, in the majority of previous work, \(\hbox {CO}_2\) concentration and gasflow have been studied separately. This study focuses on a mainstream system which simultaneously measures respiratory \(\hbox {CO}_2\) concentration and gasflow at the same location, allowing for volumetric capnography to be implemented. A non-dispersive infrared monitor is used to measure \(\hbox {CO}_2\) concentration and a differential pressure sensor is used to measure gasflow. In developing this new device, we designed a custom airway adapter which can be placed in line with the breathing circuit and accurately monitor relevant respiratory parameters. Because the airway adapter is used both for capnography and gasflow, our system reduces mechanical deadspace. The finite element method was used to design the airway adapter which can provide a strong differential pressure while reducing airway resistance. Statistical analysis using the coefficient of variation was performed to find the optimal driving voltage of the pressure transducer. Calibration between variations and flows was used to avoid pressure signal drift. We carried out targeted experiments using the proposed device and confirmed that the device can produce stable signals.
Literature
1.
go back to reference Bates J, Schmalisch G, Filbrun D, Stocks J. Tidal breath analysis for infant pulmonary function testing. ers/ats task force on standards for infant respiratory function testing. european respiratory society/american thoracic society. Eur Respir J. 2000;16(6):1180–92.CrossRefPubMed Bates J, Schmalisch G, Filbrun D, Stocks J. Tidal breath analysis for infant pulmonary function testing. ers/ats task force on standards for infant respiratory function testing. european respiratory society/american thoracic society. Eur Respir J. 2000;16(6):1180–92.CrossRefPubMed
2.
go back to reference Berggren M. Improved response time with a new miniaturised main-stream multigas monitor. JCMC. 2009;23(6):355–61. Berggren M. Improved response time with a new miniaturised main-stream multigas monitor. JCMC. 2009;23(6):355–61.
3.
go back to reference Cinar O, Acar YA, Arziman İ, Kilic E, Eyi YE, Ocal R. Can mainstream end-tidal carbon dioxide measurement accurately predict the arterial carbon dioxide level of patients with acute dyspnea in ed. AJEM. 2012;30(2):358–61.CrossRef Cinar O, Acar YA, Arziman İ, Kilic E, Eyi YE, Ocal R. Can mainstream end-tidal carbon dioxide measurement accurately predict the arterial carbon dioxide level of patients with acute dyspnea in ed. AJEM. 2012;30(2):358–61.CrossRef
4.
go back to reference Jaffe MB, Orr J. Continuous monitoring of respiratory flow and CO2. IEEE Eng Med Biol Mag. 2010;29(2):44–52.CrossRefPubMed Jaffe MB, Orr J. Continuous monitoring of respiratory flow and CO2. IEEE Eng Med Biol Mag. 2010;29(2):44–52.CrossRefPubMed
5.
go back to reference John RES. End-tidal carbon dioxide monitoring. Crit Care Nurse. 2003;23(4):83–8. John RES. End-tidal carbon dioxide monitoring. Crit Care Nurse. 2003;23(4):83–8.
6.
go back to reference Kuhn K, Pignanelli E, Schutze A. Versatile gas detection system based on combined ndir transmission and photoacoustic absorption measurements. IEEE Sensl J. 2013;13(3):934–40.CrossRef Kuhn K, Pignanelli E, Schutze A. Versatile gas detection system based on combined ndir transmission and photoacoustic absorption measurements. IEEE Sensl J. 2013;13(3):934–40.CrossRef
7.
go back to reference M. Pekdemir, O. Cinar, S. Yilmaz, E. Yaka, M. Yuksel, Disparity between mainstream and sidestream end tidal carbon dioxide values and arterial carbon dioxide levels. Respir Care. respcare–02227 (2013) M. Pekdemir, O. Cinar, S. Yilmaz, E. Yaka, M. Yuksel, Disparity between mainstream and sidestream end tidal carbon dioxide values and arterial carbon dioxide levels. Respir Care. respcare–02227 (2013)
8.
go back to reference Sotnikova GY, Gavrilov GA, Aleksandrov SE, Kapralov AA, Karandashev SA, Matveev BA, Remennyy MA. Low voltage co-gas sensor based on iii–v mid-ir immersion lens diode optopairs: where we are and how far we can go? IEEE Sens J. 2010;10(2):225–34.CrossRef Sotnikova GY, Gavrilov GA, Aleksandrov SE, Kapralov AA, Karandashev SA, Matveev BA, Remennyy MA. Low voltage co-gas sensor based on iii–v mid-ir immersion lens diode optopairs: where we are and how far we can go? IEEE Sens J. 2010;10(2):225–34.CrossRef
9.
go back to reference Xie Q, Li J, Gao X, Jia J. Fourier domain local narrow-band signal extraction algorithm and its application to real-time infrared gas detection. Sens Actuators B Chem. 2010;146(1):35–9.CrossRef Xie Q, Li J, Gao X, Jia J. Fourier domain local narrow-band signal extraction algorithm and its application to real-time infrared gas detection. Sens Actuators B Chem. 2010;146(1):35–9.CrossRef
10.
go back to reference Xu S, Chen M. Design and modeling of non-linear infrared transducer for measuring methane using cross-correlation method. IMEKO. 2012;45(3):325–32. Xu S, Chen M. Design and modeling of non-linear infrared transducer for measuring methane using cross-correlation method. IMEKO. 2012;45(3):325–32.
11.
go back to reference Yang J, Wang B, Fan C, Wang L. A new single-end mainstream CO2 capnograph. Comput Methods Biomech Biomed Eng. 2011;14(12):1033–9.CrossRef Yang J, Wang B, Fan C, Wang L. A new single-end mainstream CO2 capnograph. Comput Methods Biomech Biomed Eng. 2011;14(12):1033–9.CrossRef
12.
go back to reference Yang J, Wang H, Chen B, Wang B, Wang L. Use of signal decomposition to compensate for respiratory disturbance in mainstream capnometer. Appl Opt. 2014;53(10):2145–51.CrossRefPubMed Yang J, Wang H, Chen B, Wang B, Wang L. Use of signal decomposition to compensate for respiratory disturbance in mainstream capnometer. Appl Opt. 2014;53(10):2145–51.CrossRefPubMed
13.
go back to reference Yang J, Wang H, Wang B, Wang L. Accurate and stable continuous monitoring module by mainstream capnography. J Clin Monit Comput. 2014;28(4):363–9.CrossRefPubMed Yang J, Wang H, Wang B, Wang L. Accurate and stable continuous monitoring module by mainstream capnography. J Clin Monit Comput. 2014;28(4):363–9.CrossRefPubMed
14.
go back to reference Yang Y, Gao Z, Zhong D, Lin W. Detection of nitrogen dioxide using an external modulation diode laser. Appl Opt. 2013;52(13):3027–30.CrossRefPubMed Yang Y, Gao Z, Zhong D, Lin W. Detection of nitrogen dioxide using an external modulation diode laser. Appl Opt. 2013;52(13):3027–30.CrossRefPubMed
15.
go back to reference Zhe C, Rong Z, Rui-Yi Q. A wireless portable system with microsensors for monitoring respiratory diseases. IEEE Trans Biomed Eng. 2012;59(11):3110–6.CrossRef Zhe C, Rong Z, Rui-Yi Q. A wireless portable system with microsensors for monitoring respiratory diseases. IEEE Trans Biomed Eng. 2012;59(11):3110–6.CrossRef
16.
go back to reference Zhu Z, Xu Y, Jiang B. A one ppm NDIR methane gas sensor with single frequency filter denoising algorithm. Sensors (Basel). 2012;12(9):12729–40.CrossRef Zhu Z, Xu Y, Jiang B. A one ppm NDIR methane gas sensor with single frequency filter denoising algorithm. Sensors (Basel). 2012;12(9):12729–40.CrossRef
Metadata
Title
A mainstream monitoring system for respiratory CO2 concentration and gasflow
Authors
Jiachen Yang
Bobo Chen
Kyle Burk
Haitao Wang
Jianxiong Zhou
Publication date
01-08-2016
Publisher
Springer Netherlands
Published in
Journal of Clinical Monitoring and Computing / Issue 4/2016
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-015-9739-y

Other articles of this Issue 4/2016

Journal of Clinical Monitoring and Computing 4/2016 Go to the issue