Skip to main content
Top
Published in: Journal of Clinical Monitoring and Computing 6/2015

01-12-2015 | Original Research

Cerebral oxygenation and processed EEG response to clamping and shunting during carotid endarterectomy under general anesthesia

Authors: William Perez, Christopher Dukatz, Sami El-Dalati, James Duncan, Mahmoud Abdel-Rasoul, Andrew Springer, Michael R. Go, Roger Dzwonczyk

Published in: Journal of Clinical Monitoring and Computing | Issue 6/2015

Login to get access

Abstract

Clamping and shunting during carotid endarterectomy (CEA) surgery causes changes in cerebral blood flow. The purpose of this study was to assess and compare, side by side, the cerebral oxygenation (rSO2) and processed electroencephalogram (EEG) response bilaterally to carotid artery clamping and shunting in patients undergoing CEA under general anesthesia. With institutional approval and written informed consent, patients undergoing CEA under general anesthesia and routine carotid artery shunting were recorded bilaterally, simultaneously and continuously with an rSO2 and processed EEG monitor. The response of the monitors during carotid artery clamping and shunting were assessed and compared between monitors and bilaterally within each monitor. Sixty-nine patients were included in the study. At clamping the surgical-side and contralateral-side rSO2 dropped significantly below the baseline incision value (−17.6 and −9.4 % respectively). After shunting, the contralateral-side rSO2 returned to baseline while the surgical-side rSO2 remained significantly below baseline (−9.0 %) until the shunt was removed following surgery. At clamping the surgical-side and contralateral-side processed EEG also dropped below baseline (−19.9 and −20.6 % respectively). However, following shunt activation, the processed EEG returned bilaterally to baseline. During the course of this research, we found the rSO2 monitor to be clinically more robust (4.4 % failure rate) than the processed EEG monitor (20.0 % failure rate). There was no correlation between the rSO2 or processed EEG changes that occurred immediately after clamping and the degree of surgical side stenosis measured pre-operatively. Both rSO2 and processed EEG respond to clamping and shunting during CEA. Cerebral oximetry discriminates between the surgical and contralateral side during surgery. The rSO2 monitor is more reliable in the real-world clinical setting. Future studies should focus on developing algorithms based on these monitors that can predict clamping-induced cerebral ischemia during CEA in order to decide whether carotid artery shunting is worth the associated risks. From the practical point of view, the rSO2 monitor may be the better monitor for this purpose.
Literature
1.
go back to reference Roger VL, Go AS, Lloyd-Jones DM, Benjamin EJ, Berry JD, Borden WB, et al. Heart disease and stroke statistics—2012 update: a report from the American Heart Association. Circulation. 2012;125:e2–220.PubMedCentralCrossRefPubMed Roger VL, Go AS, Lloyd-Jones DM, Benjamin EJ, Berry JD, Borden WB, et al. Heart disease and stroke statistics—2012 update: a report from the American Heart Association. Circulation. 2012;125:e2–220.PubMedCentralCrossRefPubMed
2.
go back to reference Kofke WA, Brauer P, Policare R, Penthany S, Barker D, Horton J. Middle cerebral artery blood flow velocity and stable xenon-enhanced computed tomographic blood flow during balloon test occlusion of the internal carotid artery. Stroke. 1995;26(9):1603–6.CrossRefPubMed Kofke WA, Brauer P, Policare R, Penthany S, Barker D, Horton J. Middle cerebral artery blood flow velocity and stable xenon-enhanced computed tomographic blood flow during balloon test occlusion of the internal carotid artery. Stroke. 1995;26(9):1603–6.CrossRefPubMed
3.
go back to reference Bond R, Rerkasem K, Rothwell PM. Routine or selective carotid artery shunting for carotid endarterectomy (and different methods of monitoring in selective shunting). Stroke. 2003;34:824–5.CrossRefPubMed Bond R, Rerkasem K, Rothwell PM. Routine or selective carotid artery shunting for carotid endarterectomy (and different methods of monitoring in selective shunting). Stroke. 2003;34:824–5.CrossRefPubMed
4.
go back to reference Girn HR, Dellagrammaticas D, Laughlan K, Gough MJ. Carotid endarterectomy: technical practices of surgeons participating in the GALA trial. Eur J Vasc Endovasc Surg. 2008;36:385–9.CrossRefPubMed Girn HR, Dellagrammaticas D, Laughlan K, Gough MJ. Carotid endarterectomy: technical practices of surgeons participating in the GALA trial. Eur J Vasc Endovasc Surg. 2008;36:385–9.CrossRefPubMed
5.
go back to reference Pennekamp CW, Bots ML, Kapelle LJ, Moll FL, de Borst GJ. The value of near-infrared spectroscopy measured cerebral oximetry during carotid endarterectomy in perioperative stroke prevention. A review. Eur J Vasc Endovasc Surg. 2009;38(5):539–45.CrossRefPubMed Pennekamp CW, Bots ML, Kapelle LJ, Moll FL, de Borst GJ. The value of near-infrared spectroscopy measured cerebral oximetry during carotid endarterectomy in perioperative stroke prevention. A review. Eur J Vasc Endovasc Surg. 2009;38(5):539–45.CrossRefPubMed
6.
go back to reference Pennekamp CW, Immink RV, den Ruijter HM, Kappelle LJ, Bots ML, Buhre WF, et al. Near-infrared spectroscopy to indicate selective shunt use during carotid endarterectomy. Eur J Vasc Endovasc Surg. 2013;46(4):397–403.CrossRefPubMed Pennekamp CW, Immink RV, den Ruijter HM, Kappelle LJ, Bots ML, Buhre WF, et al. Near-infrared spectroscopy to indicate selective shunt use during carotid endarterectomy. Eur J Vasc Endovasc Surg. 2013;46(4):397–403.CrossRefPubMed
7.
go back to reference Dahaba AA, Xue JX, Hua Y, Liu QH, Xu GX, Liu YM, et al. The utility of using the bispectral Index–Vista for detecting cross-clamping decline in cerebral blood flow velocity. Neurosurgery 2010; 67(3 Suppl Operative):ons102–7; discussion ons107. doi: 10.1227/01.NEU.0000383152.50183.81. Dahaba AA, Xue JX, Hua Y, Liu QH, Xu GX, Liu YM, et al. The utility of using the bispectral Index–Vista for detecting cross-clamping decline in cerebral blood flow velocity. Neurosurgery 2010; 67(3 Suppl Operative):ons102–7; discussion ons107. doi: 10.​1227/​01.​NEU.​0000383152.​50183.​81.
8.
go back to reference Rerkasem K, Rothwell PM. Routine or selective carotid artery shunting for carotid endarterectomy (and different methods of monitoring in selective shunting). Stroke. 2010;41:e53–4.CrossRef Rerkasem K, Rothwell PM. Routine or selective carotid artery shunting for carotid endarterectomy (and different methods of monitoring in selective shunting). Stroke. 2010;41:e53–4.CrossRef
9.
go back to reference Kodaka MK, Nishikawa Y, Suzuki T, Asano K, Maeyama A, Miyao H. Does bilateral bispectral index monitoring (BIS) detect the discrepancy of cerebral reperfusion during carotid endarterectomy? J Clin Anesth. 2009;21:431–4.CrossRefPubMed Kodaka MK, Nishikawa Y, Suzuki T, Asano K, Maeyama A, Miyao H. Does bilateral bispectral index monitoring (BIS) detect the discrepancy of cerebral reperfusion during carotid endarterectomy? J Clin Anesth. 2009;21:431–4.CrossRefPubMed
10.
go back to reference Leichtle SW, Mouawad NJ, Welch K, Lampman R, Whitehouse WM Jr, Heidenreich M. Outcomes of carotid endarterectomy under general and regional anesthesia from the American College of Surgeons’ National Surgical Quality Improvement Program. J Vasc Surg. 2012;56(1):81–8.CrossRefPubMed Leichtle SW, Mouawad NJ, Welch K, Lampman R, Whitehouse WM Jr, Heidenreich M. Outcomes of carotid endarterectomy under general and regional anesthesia from the American College of Surgeons’ National Surgical Quality Improvement Program. J Vasc Surg. 2012;56(1):81–8.CrossRefPubMed
11.
go back to reference Skordilis M, Rich N, Viloria A, Dimitrova G, Bergese S, Dzwonczyk R. Electroencephalogram response of patients undergoing carotid endarterectomy: a pilot study. Ann Vasc Surg. 2011;25:909–12.CrossRefPubMed Skordilis M, Rich N, Viloria A, Dimitrova G, Bergese S, Dzwonczyk R. Electroencephalogram response of patients undergoing carotid endarterectomy: a pilot study. Ann Vasc Surg. 2011;25:909–12.CrossRefPubMed
12.
go back to reference Samra SK, Dy EA, Welch K, Dorje P, Zelenock GB, Stanley JC. Evaluation of a cerebral oximeter as a monitor of cerebral ischemia during carotid endarterectomy. Anesthesiology. 2000;93:964–70.CrossRefPubMed Samra SK, Dy EA, Welch K, Dorje P, Zelenock GB, Stanley JC. Evaluation of a cerebral oximeter as a monitor of cerebral ischemia during carotid endarterectomy. Anesthesiology. 2000;93:964–70.CrossRefPubMed
13.
go back to reference Estruch-Perez MJ, Ausina-Aguilar A, Barbera-Alacreu M, Sanchez-Morillo J, Solaz-Roldan C, Morales-Suarez-Varela MM. Bispectral index changes in carotid surgery. Ann Vasc Surg. 2010;24:393–9.CrossRefPubMed Estruch-Perez MJ, Ausina-Aguilar A, Barbera-Alacreu M, Sanchez-Morillo J, Solaz-Roldan C, Morales-Suarez-Varela MM. Bispectral index changes in carotid surgery. Ann Vasc Surg. 2010;24:393–9.CrossRefPubMed
14.
go back to reference Stilo F, Spinelli F, Martelli E, Pipitó N, Barillà D, De Caridi G, et al. The sensibility and specificity of cerebral oximetry, measured by INVOS 4100, in patients undergoing carotid endarterectomy compared with awake testing. Minerva Anestesiol. 2012;78(10):1126–35.PubMed Stilo F, Spinelli F, Martelli E, Pipitó N, Barillà D, De Caridi G, et al. The sensibility and specificity of cerebral oximetry, measured by INVOS 4100, in patients undergoing carotid endarterectomy compared with awake testing. Minerva Anestesiol. 2012;78(10):1126–35.PubMed
15.
go back to reference Pedrini L, Magnoni F, Sensi L, Pisano E, Ballestrazzi M, Cirelli M, et al. Is near-infrared spectroscopy a reliable method to evaluate clamping ischemia during carotid surgery? Stroke Res Treat. 2012:156975. doi: 10.1155/2012/156975. (Epub 2011 Nov 9). Pedrini L, Magnoni F, Sensi L, Pisano E, Ballestrazzi M, Cirelli M, et al. Is near-infrared spectroscopy a reliable method to evaluate clamping ischemia during carotid surgery? Stroke Res Treat. 2012:156975. doi: 10.​1155/​2012/​156975. (Epub 2011 Nov 9).
16.
go back to reference Zogogiannis ID, Iatrou CA, Lazarides MK, Vogiatzaki TD, Wachtel MS, Chatzigakis PK, et al. Evaluation of an intraoperative algorithm based on near-infrared refracted spectroscopy monitoring, in the intraoperative decision for shunt placement, in patients undergoing carotid endarterectomy. Middle East J Anesthesiol. 2011;21(3):367–73.PubMed Zogogiannis ID, Iatrou CA, Lazarides MK, Vogiatzaki TD, Wachtel MS, Chatzigakis PK, et al. Evaluation of an intraoperative algorithm based on near-infrared refracted spectroscopy monitoring, in the intraoperative decision for shunt placement, in patients undergoing carotid endarterectomy. Middle East J Anesthesiol. 2011;21(3):367–73.PubMed
17.
go back to reference Heller H, Hatami R, Mullin P, Sciacca RR, Khandji AG, Hamberger M, et al. Bilateral bispectral index monitoring during suppression of unilateral hemispheric function. Anesth Analg. 2005;101(1):235–41.PubMedCentralCrossRefPubMed Heller H, Hatami R, Mullin P, Sciacca RR, Khandji AG, Hamberger M, et al. Bilateral bispectral index monitoring during suppression of unilateral hemispheric function. Anesth Analg. 2005;101(1):235–41.PubMedCentralCrossRefPubMed
Metadata
Title
Cerebral oxygenation and processed EEG response to clamping and shunting during carotid endarterectomy under general anesthesia
Authors
William Perez
Christopher Dukatz
Sami El-Dalati
James Duncan
Mahmoud Abdel-Rasoul
Andrew Springer
Michael R. Go
Roger Dzwonczyk
Publication date
01-12-2015
Publisher
Springer Netherlands
Published in
Journal of Clinical Monitoring and Computing / Issue 6/2015
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-014-9657-4

Other articles of this Issue 6/2015

Journal of Clinical Monitoring and Computing 6/2015 Go to the issue