Skip to main content
Top
Published in: Journal of Clinical Monitoring and Computing 5/2015

01-10-2015 | Original Research

Continuous measurement of cardiac output with the electrical velocimetry method in patients under spinal anesthesia for cesarean delivery

Authors: Yanhong Liu, May C. M. Pian-Smith, Lisa R. Leffert, Rebecca D. Minehart, Andrea Torri, Charles Coté, Robert M. Kacmarek, Yandong Jiang

Published in: Journal of Clinical Monitoring and Computing | Issue 5/2015

Login to get access

Abstract

In this study, we aimed to continuously measure cardiac output (CO) with the electrical velocimetry (EV) method and characterize the hemodynamic profile of patients undergoing spinal anesthesia for elective cesarean delivery (CD), and to discuss the potential benefit of using real time CO monitoring to guide patient management. Forty-two patients scheduled for elective CD under spinal anesthesia were enrolled in this observational study. A non-invasive CO monitor incorporating the electrical velocimetry algorithm, ICON® (Cardiotronic®, La Jolla, California, USA), was used to measure CO and stroke volume (SV) continuously. Peripheral venous pressure was measured intermittently at pre-defined time points. Systemic vascular resistance was calculated retrospectively after completion of the study. Hemodynamic changes at pre-defined time points and caused by phenylephrine administration were analyzed. Hypotension (MAP reduction more than 20 % from baseline values) occurred in 71.1 % of patients after spinal anesthesia, while the coinstantaneous CO was increased ≥20 % from baseline in the majority of patients (76.3 %) at the same time. Significant increase in CO took place at 3–2 min before the administration of phenylephrine bolus. Treatment of hypotension with phenylephrine was associated with significant decrease in CO. Continuous CO monitoring with EV enables clinicians to determine CO and SV changes prior to onset of hypotension and to better understand patients’ hemodynamics. It is an important addition to the current monitoring. The benefit of routinely using this technique remains to be determined in term of the patient outcomes.
Literature
1.
go back to reference Menacker F, Hamilton BE. Recent trends in cesarean delivery in the United States. NCHS Data Brief. 2010;35:1–8.PubMed Menacker F, Hamilton BE. Recent trends in cesarean delivery in the United States. NCHS Data Brief. 2010;35:1–8.PubMed
2.
go back to reference Habib AS. A review of the impact of phenylephrine administration on maternal hemodynamics and maternal and neonatal outcomes in women undergoing cesarean delivery under spinal anesthesia. Anesth Analg. 2012;114:377–90.CrossRefPubMed Habib AS. A review of the impact of phenylephrine administration on maternal hemodynamics and maternal and neonatal outcomes in women undergoing cesarean delivery under spinal anesthesia. Anesth Analg. 2012;114:377–90.CrossRefPubMed
3.
go back to reference Borgeat A, Ekatodramis G, Schenker CA. Postoperative nausea and vomiting in regional anesthesia: a review. Anesthesiology. 2003;98:530–47.CrossRefPubMed Borgeat A, Ekatodramis G, Schenker CA. Postoperative nausea and vomiting in regional anesthesia: a review. Anesthesiology. 2003;98:530–47.CrossRefPubMed
4.
go back to reference Dyer RA, Reed AR, van Dyk D, Arcache MJ, Hodges O, Lombard CJ, Greenwood J, James MF. Hemodynamic effects of ephedrine, phenylephrine, and the coadministration of phenylephrine with oxytocin during spinal anesthesia for elective cesarean delivery. Anesthesiology. 2009;111:753–65.CrossRefPubMed Dyer RA, Reed AR, van Dyk D, Arcache MJ, Hodges O, Lombard CJ, Greenwood J, James MF. Hemodynamic effects of ephedrine, phenylephrine, and the coadministration of phenylephrine with oxytocin during spinal anesthesia for elective cesarean delivery. Anesthesiology. 2009;111:753–65.CrossRefPubMed
5.
go back to reference Langesaeter E, Dyer RA. Maternal haemodynamic changes during spinal anaesthesia for caesarean section. Curr Opin Anaesthesiol. 2011;24:242–8.CrossRefPubMed Langesaeter E, Dyer RA. Maternal haemodynamic changes during spinal anaesthesia for caesarean section. Curr Opin Anaesthesiol. 2011;24:242–8.CrossRefPubMed
6.
go back to reference Peyton PJ, Chong SW. Minimally invasive measurement of cardiac output during surgery and critical care: a meta-analysis of accuracy and precision. Anesthesiology. 2010;113:1220–35.CrossRefPubMed Peyton PJ, Chong SW. Minimally invasive measurement of cardiac output during surgery and critical care: a meta-analysis of accuracy and precision. Anesthesiology. 2010;113:1220–35.CrossRefPubMed
7.
go back to reference Schmidt C, Theilmeier G, Van Aken H, Korsmeier P, Wirtz SP, Berendes E, Hoffmeier A, Meissner A. Comparison of electrical velocimetry and transoesophageal Doppler echocardiography for measuring stroke volume and cardiac output. Br J Anaesth. 2005;95:603–10.CrossRefPubMed Schmidt C, Theilmeier G, Van Aken H, Korsmeier P, Wirtz SP, Berendes E, Hoffmeier A, Meissner A. Comparison of electrical velocimetry and transoesophageal Doppler echocardiography for measuring stroke volume and cardiac output. Br J Anaesth. 2005;95:603–10.CrossRefPubMed
8.
go back to reference Mekis D, Kamenik M, Starc V, Jeretin S. Cardiac output measurements with electrical velocimetry in patients undergoing CABG surgery: a comparison with intermittent thermodilution. Eur J Anaesthesiol. 2008;25:237–42.CrossRefPubMed Mekis D, Kamenik M, Starc V, Jeretin S. Cardiac output measurements with electrical velocimetry in patients undergoing CABG surgery: a comparison with intermittent thermodilution. Eur J Anaesthesiol. 2008;25:237–42.CrossRefPubMed
9.
go back to reference Norozi K, Beck C, Osthaus WA, Wille I, Wessel A, Bertram H. Electrical velocimetry for measuring cardiac output in children with congenital heart disease. Br J Anaesth. 2008;100:88–94.CrossRefPubMed Norozi K, Beck C, Osthaus WA, Wille I, Wessel A, Bertram H. Electrical velocimetry for measuring cardiac output in children with congenital heart disease. Br J Anaesth. 2008;100:88–94.CrossRefPubMed
10.
go back to reference Raue W, Swierzy M, Koplin G, Schwenk W. Comparison of electrical velocimetry and transthoracic thermodilution technique for cardiac output assessment in critically ill patients. Eur J Anaesthesiol. 2009;26:1067–71.CrossRefPubMed Raue W, Swierzy M, Koplin G, Schwenk W. Comparison of electrical velocimetry and transthoracic thermodilution technique for cardiac output assessment in critically ill patients. Eur J Anaesthesiol. 2009;26:1067–71.CrossRefPubMed
11.
go back to reference Zoremba N, Bickenbach J, Krauss B, Rossaint R, Kuhlen R, Schalte G. Comparison of electrical velocimetry and thermodilution techniques for the measurement of cardiac output. Acta Anaesthesiol Scand. 2007;51:1314–9.CrossRefPubMed Zoremba N, Bickenbach J, Krauss B, Rossaint R, Kuhlen R, Schalte G. Comparison of electrical velocimetry and thermodilution techniques for the measurement of cardiac output. Acta Anaesthesiol Scand. 2007;51:1314–9.CrossRefPubMed
12.
go back to reference Osthaus WA, Huber D, Beck C, Winterhalter M, Boethig D, Wessel A, Sumpelmann R. Comparison of electrical velocimetry and transpulmonary thermodilution for measuring cardiac output in piglets. Paediatr Anaesth. 2007;17:749–55.CrossRefPubMed Osthaus WA, Huber D, Beck C, Winterhalter M, Boethig D, Wessel A, Sumpelmann R. Comparison of electrical velocimetry and transpulmonary thermodilution for measuring cardiac output in piglets. Paediatr Anaesth. 2007;17:749–55.CrossRefPubMed
13.
go back to reference Bernstein DP, Lemmens HJ. Stroke volume equation for impedance cardiography. Med Biol Eng Comput. 2005;43:443–50.CrossRefPubMed Bernstein DP, Lemmens HJ. Stroke volume equation for impedance cardiography. Med Biol Eng Comput. 2005;43:443–50.CrossRefPubMed
14.
go back to reference Bernstein DP, Osypka MJ (2003) Apparatus and method for determining an approximation of the stroke volume and the cardiac output of the heart. United States Patent 6511438. Bernstein DP, Osypka MJ (2003) Apparatus and method for determining an approximation of the stroke volume and the cardiac output of the heart. United States Patent 6511438.
15.
go back to reference Archer TL, Conrad BE, Suresh P, Tarsa M. Electrical velocimetry demonstrates the increase in cardiac output and decrease in systemic vascular resistance accompanying cesarean delivery and oxytocin administration. J Clin Anesth. 2012;24:79–82.CrossRefPubMed Archer TL, Conrad BE, Suresh P, Tarsa M. Electrical velocimetry demonstrates the increase in cardiac output and decrease in systemic vascular resistance accompanying cesarean delivery and oxytocin administration. J Clin Anesth. 2012;24:79–82.CrossRefPubMed
16.
go back to reference Archer TL. Electrical velocimetry elucidates the hemodynamics of hypertension caused by indigo carmine. J Clin Anesth. 2011;23:166–8.CrossRefPubMed Archer TL. Electrical velocimetry elucidates the hemodynamics of hypertension caused by indigo carmine. J Clin Anesth. 2011;23:166–8.CrossRefPubMed
17.
go back to reference Archer TL, Suresh P, Shapiro AE. Cardiac output measurement, by means of electrical velocimetry, may be able to determine optimum maternal position during gestation, labour and caesarean delivery, by preventing vena caval compression and maximising cardiac output and placental perfusion pressure. Anaesth Intensive Care. 2011;39:308–11.PubMed Archer TL, Suresh P, Shapiro AE. Cardiac output measurement, by means of electrical velocimetry, may be able to determine optimum maternal position during gestation, labour and caesarean delivery, by preventing vena caval compression and maximising cardiac output and placental perfusion pressure. Anaesth Intensive Care. 2011;39:308–11.PubMed
18.
go back to reference Kim SH, Park SY, Cui J, Lee JH, Cho SH, Chae WS, Jin HC, Hwang KH. Peripheral venous pressure as an alternative to central venous pressure in patients undergoing laparoscopic colorectal surgery. Br J Anaesth. 2011;106:305–11.CrossRefPubMed Kim SH, Park SY, Cui J, Lee JH, Cho SH, Chae WS, Jin HC, Hwang KH. Peripheral venous pressure as an alternative to central venous pressure in patients undergoing laparoscopic colorectal surgery. Br J Anaesth. 2011;106:305–11.CrossRefPubMed
19.
go back to reference Tugrul M, Camci E, Pembeci K, Al-Darsani A, Telci L. Relationship between peripheral and central venous pressures in different patient positions, catheter sizes, and insertion sites. J Cardiothorac Vasc Anesth. 2004;18:446–50.CrossRefPubMed Tugrul M, Camci E, Pembeci K, Al-Darsani A, Telci L. Relationship between peripheral and central venous pressures in different patient positions, catheter sizes, and insertion sites. J Cardiothorac Vasc Anesth. 2004;18:446–50.CrossRefPubMed
20.
go back to reference Nielsen PE, Erickson JR, Abouleish EI, Perriatt S, Sheppard C. Fetal heart rate changes after intrathecal sufentanil or epidural bupivacaine for labor analgesia: incidence and clinical significance. Anesth Analg. 1996;83:742–6.PubMed Nielsen PE, Erickson JR, Abouleish EI, Perriatt S, Sheppard C. Fetal heart rate changes after intrathecal sufentanil or epidural bupivacaine for labor analgesia: incidence and clinical significance. Anesth Analg. 1996;83:742–6.PubMed
21.
go back to reference Yu ZY, Lumbers ER. Measurement of baroreceptor-mediated effects on heart rate variability in fetal sheep. Pediatr Res. 2000;47:233–9.CrossRefPubMed Yu ZY, Lumbers ER. Measurement of baroreceptor-mediated effects on heart rate variability in fetal sheep. Pediatr Res. 2000;47:233–9.CrossRefPubMed
22.
go back to reference Langesaeter E, Rosseland LA, Stubhaug A. Continuous invasive blood pressure and cardiac output monitoring during cesarean delivery: a randomized, double-blind comparison of low-dose versus high-dose spinal anesthesia with intravenous phenylephrine or placebo infusion. Anesthesiology. 2008;109:856–63.CrossRefPubMed Langesaeter E, Rosseland LA, Stubhaug A. Continuous invasive blood pressure and cardiac output monitoring during cesarean delivery: a randomized, double-blind comparison of low-dose versus high-dose spinal anesthesia with intravenous phenylephrine or placebo infusion. Anesthesiology. 2008;109:856–63.CrossRefPubMed
23.
go back to reference Tihtonen K, Koobi T, Yli-Hankala A, Uotila J. Maternal hemodynamics during cesarean delivery assessed by whole-body impedance cardiography. Acta Obstet Gynecol Scand. 2005;84:355–61.CrossRefPubMed Tihtonen K, Koobi T, Yli-Hankala A, Uotila J. Maternal hemodynamics during cesarean delivery assessed by whole-body impedance cardiography. Acta Obstet Gynecol Scand. 2005;84:355–61.CrossRefPubMed
24.
go back to reference Stewart A, Fernando R, McDonald S, Hignett R, Jones T, Columb M. The dose-dependent effects of phenylephrine for elective cesarean delivery under spinal anesthesia. Anesth Analg. 2010;111:1230–7.CrossRefPubMed Stewart A, Fernando R, McDonald S, Hignett R, Jones T, Columb M. The dose-dependent effects of phenylephrine for elective cesarean delivery under spinal anesthesia. Anesth Analg. 2010;111:1230–7.CrossRefPubMed
25.
go back to reference Landzberg JS, Parker JD, Gauthier DF, Colucci WS. Effects of myocardial alpha 1-adrenergic receptor stimulation and blockade on contractility in humans. Circulation. 1991;84:1608–14.CrossRefPubMed Landzberg JS, Parker JD, Gauthier DF, Colucci WS. Effects of myocardial alpha 1-adrenergic receptor stimulation and blockade on contractility in humans. Circulation. 1991;84:1608–14.CrossRefPubMed
26.
go back to reference Dyer RA, Reed AR. Spinal hypotension during elective cesarean delivery: closer to a solution. Anesth Analg. 2010;111:1093–5.CrossRefPubMed Dyer RA, Reed AR. Spinal hypotension during elective cesarean delivery: closer to a solution. Anesth Analg. 2010;111:1093–5.CrossRefPubMed
28.
go back to reference Thiele RH, Nemergut EC, Lynch C 3rd. The physiologic implications of isolated alpha (1) adrenergic stimulation. Anesth Analg. 2011;113:284–96.CrossRefPubMed Thiele RH, Nemergut EC, Lynch C 3rd. The physiologic implications of isolated alpha (1) adrenergic stimulation. Anesth Analg. 2011;113:284–96.CrossRefPubMed
29.
go back to reference Brown BR Jr. Selective venoconstriction by dopamine in comparision with isoproterenol and phenylephrine. Anesthesiology. 1975;43:570–2.CrossRefPubMed Brown BR Jr. Selective venoconstriction by dopamine in comparision with isoproterenol and phenylephrine. Anesthesiology. 1975;43:570–2.CrossRefPubMed
30.
go back to reference Cannesson M, Jian Z, Chen G, Vu TQ, Hatib F. Effects of phenylephrine on cardiac output and venous return depend on the position of the heart on the Frank-Starling relationship. J Appl Physiol. 1985;113:281–9.CrossRef Cannesson M, Jian Z, Chen G, Vu TQ, Hatib F. Effects of phenylephrine on cardiac output and venous return depend on the position of the heart on the Frank-Starling relationship. J Appl Physiol. 1985;113:281–9.CrossRef
Metadata
Title
Continuous measurement of cardiac output with the electrical velocimetry method in patients under spinal anesthesia for cesarean delivery
Authors
Yanhong Liu
May C. M. Pian-Smith
Lisa R. Leffert
Rebecca D. Minehart
Andrea Torri
Charles Coté
Robert M. Kacmarek
Yandong Jiang
Publication date
01-10-2015
Publisher
Springer Netherlands
Published in
Journal of Clinical Monitoring and Computing / Issue 5/2015
Print ISSN: 1387-1307
Electronic ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-014-9645-8

Other articles of this Issue 5/2015

Journal of Clinical Monitoring and Computing 5/2015 Go to the issue