Skip to main content
Top
Published in: Journal of Clinical Immunology 3/2018

01-04-2018 | Original Article

Low Serum IgE Is a Sensitive and Specific Marker for Common Variable Immunodeficiency (CVID)

Authors: Monica G. Lawrence, Thamiris V. Palacios-Kibler, Lisa J. Workman, Alexander J. Schuyler, John W. Steinke, Spencer C. Payne, Emily C. McGowan, James Patrie, Ramsay L. Fuleihan, Kathleen E. Sullivan, Patricia L. Lugar, Camellia L. Hernandez, Douglas E. Beakes, James W. Verbsky, Thomas A. E. Platts-Mills, Charlotte Cunningham-Rundles, John M. Routes, Larry Borish

Published in: Journal of Clinical Immunology | Issue 3/2018

Login to get access

Abstract

Although small prior studies have suggested that IgE can be low in common variable immunodeficiency (CVID), the workup for patients with recurrent infections and suspected hypogammaglobulinemia does not include the routine measurement of serum IgE. We sought to test the hypothesis that low/undetectable serum IgE is characteristic of CVID by comparing the frequency of low/undetectable serum IgE in healthy controls and patients with CVID. We measured total serum IgE in a large multi-center cohort of patients with CVID (n = 354) and compared this to large population-based cohorts of children and adults. We further compared IgE levels in patients with CVID to those with other forms of humoral immunodeficiency, and in a subset, measured levels of allergen-specific serum IgE and IgG subclasses. Lastly, we evaluated for the presence of IgE in commercially available immunoglobulin replacement therapy (IgRT) products. An undetectable serum IgE (< 2 IU/ml) occurs in only 3.3% (95% CI, 1.9–5.7%) of the general population. In contrast, an undetectable IgE occurs in 75.6% (95% CI, 65.6–85.7%) of patients with CVID. Conversely, a high IgE (> 180 IU/ml) is very uncommon in CVID (0.3% of patients). IgE is > 2 IU/ml in 91.2% of patients with secondary hypogammaglobulinemia, and thus, an IgE < LLOD is suggestive of a primary humoral immunodeficiency. Allergen-specific IgE is not detectable in 96.5% of patients with CVID. Sufficient quantities of IgE to change the total serum IgE are not contained in IgRT. The IgG1/IgG4 ratio is increased in subjects with low IgE, regardless of whether they are controls or have CVID. These findings support the routine measurement of serum IgE in the workup of patients with hypogammaglobulinemia.
Appendix
Available only for authorised users
Literature
9.
go back to reference Stites DP, Ishizaka K, Fudenberg HH. Serum IgE concentrations in hypogammaglobulinaemia and selective IgA deficiency. Studies on patients and family members. Clin Exp Immunol. 1972;10(3):391–7.PubMedPubMedCentral Stites DP, Ishizaka K, Fudenberg HH. Serum IgE concentrations in hypogammaglobulinaemia and selective IgA deficiency. Studies on patients and family members. Clin Exp Immunol. 1972;10(3):391–7.PubMedPubMedCentral
10.
go back to reference Waldmann TA, Polmar SH, Balestra ST, Jost MC, Bruce RM, Terry WD. Immunoglobulin E in immunologic deficiency diseases. II. Serum IgE concentration of patients with acquired hypogammaglobulinemia, thymoma and hypogammaglobulinemia, myotonic dystrophy, intestinal lymphangiectasia and Wiskott-Aldrich syndrome. J Immunol. 1972;109(2):304–10.PubMed Waldmann TA, Polmar SH, Balestra ST, Jost MC, Bruce RM, Terry WD. Immunoglobulin E in immunologic deficiency diseases. II. Serum IgE concentration of patients with acquired hypogammaglobulinemia, thymoma and hypogammaglobulinemia, myotonic dystrophy, intestinal lymphangiectasia and Wiskott-Aldrich syndrome. J Immunol. 1972;109(2):304–10.PubMed
11.
go back to reference McLaughlan P, Stanworth DR, Webster AD, Asherson GL. Serum IgE in immune deficiency disorders. Clin Exp Immunol. 1974;16(3):375–81.PubMedPubMedCentral McLaughlan P, Stanworth DR, Webster AD, Asherson GL. Serum IgE in immune deficiency disorders. Clin Exp Immunol. 1974;16(3):375–81.PubMedPubMedCentral
30.
go back to reference Tovo PA, Gabiano C, Grazia Roncarolo M, Altare F. IgE content of commercial intravenous IgG preparations. Lancet. 1984;1(8374):458.CrossRefPubMed Tovo PA, Gabiano C, Grazia Roncarolo M, Altare F. IgE content of commercial intravenous IgG preparations. Lancet. 1984;1(8374):458.CrossRefPubMed
32.
35.
Metadata
Title
Low Serum IgE Is a Sensitive and Specific Marker for Common Variable Immunodeficiency (CVID)
Authors
Monica G. Lawrence
Thamiris V. Palacios-Kibler
Lisa J. Workman
Alexander J. Schuyler
John W. Steinke
Spencer C. Payne
Emily C. McGowan
James Patrie
Ramsay L. Fuleihan
Kathleen E. Sullivan
Patricia L. Lugar
Camellia L. Hernandez
Douglas E. Beakes
James W. Verbsky
Thomas A. E. Platts-Mills
Charlotte Cunningham-Rundles
John M. Routes
Larry Borish
Publication date
01-04-2018
Publisher
Springer US
Published in
Journal of Clinical Immunology / Issue 3/2018
Print ISSN: 0271-9142
Electronic ISSN: 1573-2592
DOI
https://doi.org/10.1007/s10875-018-0476-0

Other articles of this Issue 3/2018

Journal of Clinical Immunology 3/2018 Go to the issue