Skip to main content
Top
Published in: Journal of Interventional Cardiac Electrophysiology 2/2020

01-08-2020 | Stroke

Comparison of echocardiographic and fluoroscopic sizing of the left atrial appendage prior to percutaneous closure

Authors: Soroosh Kiani, Akshar Vipul Patel, Mikhael F. El-Chami, Anshul M. Patel, Faisal M. Merchant, Stacy B. Westerman, David B. De Lurgio, Michael H. Hoskins

Published in: Journal of Interventional Cardiac Electrophysiology | Issue 2/2020

Login to get access

Abstract

Purpose

Sizing of the left atrial appendage (LAA) ostium prior to occlusion (LAAO) is routinely performed with transesophageal echocardiography (TEE). We sought to compare the utility of sizing via fluoroscopy to TEE for percutaneous LAAO.

Methods

We retrospectively evaluated all patients undergoing percutaneous LAAO at our institution from April 2015 through January 2018 (n = 195). We evaluated baseline characteristics, maximum measured ostium size (for both TEE and fluoroscopy), and differences in measured size to device size for both techniques.

Results

Of the total cohort, 185 (95%) had both intraoperative TEE and fluoroscopic images available for analysis and were included in the final analysis. The mean age was 74 years and 64% were male. Hypertension was present in 89%, diabetes in 30%, and stroke in 32% of patients. The mean ejection fraction was 51%. The most common LAA morphology was “wind sock” (52%). Measured ostial diameter on fluoroscopy was larger compared with TEE (2.04 ± 3.43 mm larger on fluoroscopy, p < 0.001). Ostium diameter on TEE was more closely correlated to the size of the device implanted compared with fluoroscopy (0.76 vs. 0.61, p = 0.001).

Conclusions

Fluoroscopy results in larger estimated LAA ostium diameter compared with TEE. Despite this, TEE was more strongly correlated to operator choice in device sizing, which may reflect practice patterns. Because compression of the ostium on the device is necessary for long-term procedural success, under-sizing may lead to a higher rate of leaks. Prospective evaluation of the utility of routine fluoroscopic sizing compared with TEE is warranted.
Literature
1.
go back to reference Chow DH, Bieliauskas G, Sawaya FJ, et al. A comparative study of different imaging modalities for successful percutaneous left atrial appendage closure. Open Heart. 2017;4(2):e000627.CrossRef Chow DH, Bieliauskas G, Sawaya FJ, et al. A comparative study of different imaging modalities for successful percutaneous left atrial appendage closure. Open Heart. 2017;4(2):e000627.CrossRef
2.
go back to reference Reddy VY, Sievert H, Halperin J, et al. Percutaneous left atrial appendage closure vs warfarin for atrial fibrillation: a randomized clinical trial Left Atrial Appendage Closure vs Warfarin for Atrial FibrillationLeft Atrial Appendage Closure vs Warfarin for Atrial Fibrillation. JAMA. 2014;312(19):1988–98.CrossRef Reddy VY, Sievert H, Halperin J, et al. Percutaneous left atrial appendage closure vs warfarin for atrial fibrillation: a randomized clinical trial Left Atrial Appendage Closure vs Warfarin for Atrial FibrillationLeft Atrial Appendage Closure vs Warfarin for Atrial Fibrillation. JAMA. 2014;312(19):1988–98.CrossRef
3.
go back to reference Onalan O, Crystal E. Left atrial appendage exclusion for stroke prevention in patients with nonrheumatic atrial fibrillation. Stroke. 2007;38(2):624–30.CrossRef Onalan O, Crystal E. Left atrial appendage exclusion for stroke prevention in patients with nonrheumatic atrial fibrillation. Stroke. 2007;38(2):624–30.CrossRef
4.
go back to reference De Backer O, Arnous S, Ihlemann N, et al. Percutaneous left atrial appendage occlusion for stroke prevention in atrial fibrillation: an update. Open Heart. 2014;1(1):e000020.CrossRef De Backer O, Arnous S, Ihlemann N, et al. Percutaneous left atrial appendage occlusion for stroke prevention in atrial fibrillation: an update. Open Heart. 2014;1(1):e000020.CrossRef
5.
go back to reference Wang DD, Forbes TJ, Lee JC, Eng MH. Echocardiographic imaging for left atrial appendage occlusion: transesophageal echocardiography and intracardiac echocardiographic imaging. Interv Cardiol Clin. 2018;7(2):219–28.PubMed Wang DD, Forbes TJ, Lee JC, Eng MH. Echocardiographic imaging for left atrial appendage occlusion: transesophageal echocardiography and intracardiac echocardiographic imaging. Interv Cardiol Clin. 2018;7(2):219–28.PubMed
6.
go back to reference Glassy MS, Sharma G, Singh GD, Smith TWR, Fan D, Rogers JH. Usable implantation depth for watchman left atrial appendage occlusion is greater with appendage angiography than transesophageal echocardiography. Catheter Cardiovasc Interv. 2019;93(5):E311–7.CrossRef Glassy MS, Sharma G, Singh GD, Smith TWR, Fan D, Rogers JH. Usable implantation depth for watchman left atrial appendage occlusion is greater with appendage angiography than transesophageal echocardiography. Catheter Cardiovasc Interv. 2019;93(5):E311–7.CrossRef
7.
go back to reference Verma DR, Yassin H, Weiss J, et al. Comparing TEE with angiographic sizing of Watchman device for left atrial appendage closure. J Am Coll Cardiol. 2017;69(11 Supplement):1141.CrossRef Verma DR, Yassin H, Weiss J, et al. Comparing TEE with angiographic sizing of Watchman device for left atrial appendage closure. J Am Coll Cardiol. 2017;69(11 Supplement):1141.CrossRef
8.
go back to reference Holmes DR, Reddy VY, Turi ZG, et al. Percutaneous closure of the left atrial appendage versus warfarin therapy for prevention of stroke in patients with atrial fibrillation: a randomised non-inferiority trial. Lancet. 2009;374(9689):534–42.CrossRef Holmes DR, Reddy VY, Turi ZG, et al. Percutaneous closure of the left atrial appendage versus warfarin therapy for prevention of stroke in patients with atrial fibrillation: a randomised non-inferiority trial. Lancet. 2009;374(9689):534–42.CrossRef
9.
go back to reference Reddy VY, Gibson DN, Kar S, et al. Post-approval U.S. experience with left atrial appendage closure for stroke prevention in atrial fibrillation. J Am Coll Cardiol. 2017;69(3):253–61.CrossRef Reddy VY, Gibson DN, Kar S, et al. Post-approval U.S. experience with left atrial appendage closure for stroke prevention in atrial fibrillation. J Am Coll Cardiol. 2017;69(3):253–61.CrossRef
10.
go back to reference Williams EJ. The comparison of regression variables. J R Stat Soc Ser B Methodol. 1959;21(2):396–9. Williams EJ. The comparison of regression variables. J R Stat Soc Ser B Methodol. 1959;21(2):396–9.
11.
go back to reference Neil JJ, Dunn OJ. Equality of dependent correlation coefficients. Biometrics. 1975;31:531–4.CrossRef Neil JJ, Dunn OJ. Equality of dependent correlation coefficients. Biometrics. 1975;31:531–4.CrossRef
12.
go back to reference Shah SJ, Bardo DME, Sugeng L, et al. Real-time three-dimensional transesophageal echocardiography of the left atrial appendage: initial experience in the clinical setting. J Am Soc Echocardiogr. 2008;21(12):1362–8.CrossRef Shah SJ, Bardo DME, Sugeng L, et al. Real-time three-dimensional transesophageal echocardiography of the left atrial appendage: initial experience in the clinical setting. J Am Soc Echocardiogr. 2008;21(12):1362–8.CrossRef
13.
go back to reference Xu B, Betancor J, Sato K, et al. Watchman device sizing: is multi-detector computed tomography superior to transesophageal echocardiography? J Am Coll Cardiol. 2018;71(11 Supplement):A1580.CrossRef Xu B, Betancor J, Sato K, et al. Watchman device sizing: is multi-detector computed tomography superior to transesophageal echocardiography? J Am Coll Cardiol. 2018;71(11 Supplement):A1580.CrossRef
14.
go back to reference Nucifora G, Faletra FF, Regoli F, et al. Evaluation of the left atrial appendage with real-time 3-dimensional transesophageal echocardiography. Circ Cardiovasc Imaging. 2011;4(5):514–23.CrossRef Nucifora G, Faletra FF, Regoli F, et al. Evaluation of the left atrial appendage with real-time 3-dimensional transesophageal echocardiography. Circ Cardiovasc Imaging. 2011;4(5):514–23.CrossRef
15.
go back to reference Prakash R, Saw J. Imaging for percutaneous left atrial appendage closure. Catheter Cardiovasc Interv. 2018;92(2):437–50.CrossRef Prakash R, Saw J. Imaging for percutaneous left atrial appendage closure. Catheter Cardiovasc Interv. 2018;92(2):437–50.CrossRef
Metadata
Title
Comparison of echocardiographic and fluoroscopic sizing of the left atrial appendage prior to percutaneous closure
Authors
Soroosh Kiani
Akshar Vipul Patel
Mikhael F. El-Chami
Anshul M. Patel
Faisal M. Merchant
Stacy B. Westerman
David B. De Lurgio
Michael H. Hoskins
Publication date
01-08-2020
Publisher
Springer US
Published in
Journal of Interventional Cardiac Electrophysiology / Issue 2/2020
Print ISSN: 1383-875X
Electronic ISSN: 1572-8595
DOI
https://doi.org/10.1007/s10840-019-00643-7

Other articles of this Issue 2/2020

Journal of Interventional Cardiac Electrophysiology 2/2020 Go to the issue