Skip to main content
Top
Published in: Journal of Interventional Cardiac Electrophysiology 3/2020

01-04-2020 | Angiography

A novel percutaneous stabilizing sheath for minimal invasive epicardial echocardiography and ablation

Authors: Alan Sugrue, Vaibhav R. Vaidya, Deepak Padmanabhan, Omar Yasin, Anas Abudan, Ameesh Isath, Ammar M. Killu, Niyada Naksuk, Brad Bolon, Paul A. Friedman, Samuel J. Asirvatham

Published in: Journal of Interventional Cardiac Electrophysiology | Issue 3/2020

Login to get access

Abstract

Purpose

Epicardial ablation and mapping are critical adjuncts to the electrophysiologist’s approach to arrhythmias; however, ablation within the epicardial space requires the avoidance of coronary arteries (CA). We aimed to evaluate the feasibility and performance of a novel-stabilizing ablation sheath housing an intracardiac echocardiography (ICE) catheter to (1) obtain Epicardial Echocardiography (EE) images, (2) visualize CAs, and (3) enable targeted delivery of radiofrequency energy away from visualized CAs.

Methods

We designed a sheath that could enclose a regular ICE catheter. This sheath has flanges and a balloon, with three interspersed windows surrounded by an electrode. In an acute canine model (N = 6), the sheath was manipulated within the pericardial space to visualize cardiac structures and CAs. Visualization of CAs was confirmed with angiography. Ablation was then performed through the window either proximal or distal to the CA.

Results

The novel sheath was successfully deployed in six canines, with no acute procedural complications. Images with an excellent spatial resolution of cardiac structures were obtained including the right ventricular outflow tract; aortic, pulmonary, and mitral valves; and left atrial appendage. CAs were successfully visualized, and ablation from a sheath window either proximal or distal to the CA did not produce angiographic or histopathological evidence of CA damage despite evidence of acute injury to the adjacent ablated myocardium.

Conclusions

This novel percutaneous stabilizing sheath was able to successfully obtain high-quality EE images as well as provide a non-fluoroscopic intra-procedural means to visualize CAs. Use of this sheath enabled successful delivery of energy to avoided CA damage.
Appendix
Available only for authorised users
Literature
1.
go back to reference Pappone C, Brugada J, Vicedomini G, Ciconte G, Manguso F, Saviano M, et al. Electrical substrate elimination in 135 consecutive patients with Brugada syndrome. Circ Arrhythm Electrophysiol. 2017;10:e005053.CrossRef Pappone C, Brugada J, Vicedomini G, Ciconte G, Manguso F, Saviano M, et al. Electrical substrate elimination in 135 consecutive patients with Brugada syndrome. Circ Arrhythm Electrophysiol. 2017;10:e005053.CrossRef
2.
go back to reference Brugada J, Pappone C, Berruezo A, Vicedomini G, Manguso F, Ciconte G, et al. Brugada syndrome phenotype elimination by epicardial substrate ablation. Circ Arrhythm Electrophysiol. 2015;8:1373–81.CrossRef Brugada J, Pappone C, Berruezo A, Vicedomini G, Manguso F, Ciconte G, et al. Brugada syndrome phenotype elimination by epicardial substrate ablation. Circ Arrhythm Electrophysiol. 2015;8:1373–81.CrossRef
3.
go back to reference Zhang P, Tung R, Zhang Z, Sheng X, Liu Q, Jiang R, et al. Characterization of the epicardial substrate for catheter ablation of Brugada syndrome. Heart Rhythm. 2016;13:2151–8.CrossRef Zhang P, Tung R, Zhang Z, Sheng X, Liu Q, Jiang R, et al. Characterization of the epicardial substrate for catheter ablation of Brugada syndrome. Heart Rhythm. 2016;13:2151–8.CrossRef
4.
go back to reference Berruezo A, Fernandez-Armenta J, Mont L, Zeljko H, Andreu D, Herczku C, et al. Combined endocardial and epicardial catheter ablation in arrhythmogenic right ventricular dysplasia incorporating scar dechanneling technique. Circ Arrhythm Electrophysiol. 2012;5:111–21.CrossRef Berruezo A, Fernandez-Armenta J, Mont L, Zeljko H, Andreu D, Herczku C, et al. Combined endocardial and epicardial catheter ablation in arrhythmogenic right ventricular dysplasia incorporating scar dechanneling technique. Circ Arrhythm Electrophysiol. 2012;5:111–21.CrossRef
5.
go back to reference Wei W, Liao H, Xue Y, Fang X, Huang J, Liu Y, et al. Long-term outcomes of radio-frequency catheter ablation on ventricular tachycardias due to arrhythmogenic right ventricular cardiomyopathy: a single center experience. PLoS One. 2017;12:e0169863.CrossRef Wei W, Liao H, Xue Y, Fang X, Huang J, Liu Y, et al. Long-term outcomes of radio-frequency catheter ablation on ventricular tachycardias due to arrhythmogenic right ventricular cardiomyopathy: a single center experience. PLoS One. 2017;12:e0169863.CrossRef
6.
go back to reference Santangeli P, Zado ES, Supple GE, Haqqani HM, Garcia FC, Tschabrunn CM, et al. Long-term outcome with catheter ablation of ventricular tachycardia in patients with arrhythmogenic right ventricular cardiomyopathy. Circ Arrhythm Electrophysiol. 2015;8:1413–21.CrossRef Santangeli P, Zado ES, Supple GE, Haqqani HM, Garcia FC, Tschabrunn CM, et al. Long-term outcome with catheter ablation of ventricular tachycardia in patients with arrhythmogenic right ventricular cardiomyopathy. Circ Arrhythm Electrophysiol. 2015;8:1413–21.CrossRef
7.
go back to reference Muser D, Santangeli P, Castro SA, Pathak RK, Liang JJ, Hayashi T, et al. Long-term outcome after catheter ablation of ventricular tachycardia in patients with nonischemic dilated cardiomyopathy. Circ Arrhythm Electrophysiol. 2016;9(10):e004328. Muser D, Santangeli P, Castro SA, Pathak RK, Liang JJ, Hayashi T, et al. Long-term outcome after catheter ablation of ventricular tachycardia in patients with nonischemic dilated cardiomyopathy. Circ Arrhythm Electrophysiol. 2016;9(10):e004328.
8.
go back to reference Muser D, Liang JJ, Pathak RK, Magnani S, Castro SA, Hayashi T, et al. Long-term outcomes of catheter ablation of electrical storm in nonischemic dilated cardiomyopathy compared with ischemic cardiomyopathy. JACC: Clin Electrophysiol. 2017;3:767–78. Muser D, Liang JJ, Pathak RK, Magnani S, Castro SA, Hayashi T, et al. Long-term outcomes of catheter ablation of electrical storm in nonischemic dilated cardiomyopathy compared with ischemic cardiomyopathy. JACC: Clin Electrophysiol. 2017;3:767–78.
9.
go back to reference Sarkozy A, Tokuda M, Tedrow UB, Sieria J, Michaud GF, Couper GS, et al. Epicardial ablation of ventricular tachycardia in ischemic heart disease. Circ Arrhythm Electrophysiol. 2013;6:1115–22.CrossRef Sarkozy A, Tokuda M, Tedrow UB, Sieria J, Michaud GF, Couper GS, et al. Epicardial ablation of ventricular tachycardia in ischemic heart disease. Circ Arrhythm Electrophysiol. 2013;6:1115–22.CrossRef
10.
go back to reference Sacher F, Roberts-Thomson K, Maury P, Tedrow U, Nault I, Steven D, et al. Epicardial ventricular tachycardia ablation a multicenter safety study. J Am Coll Cardiol. 2010;55:2366–72.CrossRef Sacher F, Roberts-Thomson K, Maury P, Tedrow U, Nault I, Steven D, et al. Epicardial ventricular tachycardia ablation a multicenter safety study. J Am Coll Cardiol. 2010;55:2366–72.CrossRef
11.
go back to reference Scanavacca MI, Sternick EB, Pisani C, Lara S, Hardy C, d'Avila A, et al. Accessory atrioventricular pathways refractory to catheter ablation: role of percutaneous epicardial approach. Circ Arrhythm Electrophysiol. 2015;8:128–36.CrossRef Scanavacca MI, Sternick EB, Pisani C, Lara S, Hardy C, d'Avila A, et al. Accessory atrioventricular pathways refractory to catheter ablation: role of percutaneous epicardial approach. Circ Arrhythm Electrophysiol. 2015;8:128–36.CrossRef
12.
go back to reference Sternick EB, Faustino M, Correa FS, Pisani C, Scanavacca MI. Percutaneous catheter ablation of epicardial accessory pathways. Arrhythmia Electrophysiol Rev. 2017;6:80–4.CrossRef Sternick EB, Faustino M, Correa FS, Pisani C, Scanavacca MI. Percutaneous catheter ablation of epicardial accessory pathways. Arrhythmia Electrophysiol Rev. 2017;6:80–4.CrossRef
13.
go back to reference Upadhyay S, Walsh EP, Cecchin F, Triedman JK, Villafane J, Saul JP. Epicardial ablation of tachyarrhythmia in children: experience at two academic centers. Pacing Clin Electrophysiol : PACE. 2017;40:1017–26.CrossRef Upadhyay S, Walsh EP, Cecchin F, Triedman JK, Villafane J, Saul JP. Epicardial ablation of tachyarrhythmia in children: experience at two academic centers. Pacing Clin Electrophysiol : PACE. 2017;40:1017–26.CrossRef
14.
go back to reference Piorkowski C, Kronborg M, Hourdain J, Piorkowski J, Kirstein B, Neudeck S, et al. Endo−/epicardial catheter ablation of atrial fibrillation: feasibility, outcome, and insights into arrhythmia mechanisms. Circ Arrhythm Electrophysiol. 2018;11:e005748.CrossRef Piorkowski C, Kronborg M, Hourdain J, Piorkowski J, Kirstein B, Neudeck S, et al. Endo−/epicardial catheter ablation of atrial fibrillation: feasibility, outcome, and insights into arrhythmia mechanisms. Circ Arrhythm Electrophysiol. 2018;11:e005748.CrossRef
15.
go back to reference Edgerton Z, Perini AP, Horton R, Trivedi C, Santangeli P, Bai R, et al. Hybrid procedure (endo/epicardial) versus standard manual ablation in patients undergoing ablation of longstanding persistent atrial fibrillation: results from a single center. J Cardiovasc Electrophysiol. 2016;27:524–30.CrossRef Edgerton Z, Perini AP, Horton R, Trivedi C, Santangeli P, Bai R, et al. Hybrid procedure (endo/epicardial) versus standard manual ablation in patients undergoing ablation of longstanding persistent atrial fibrillation: results from a single center. J Cardiovasc Electrophysiol. 2016;27:524–30.CrossRef
16.
go back to reference Tung R, Michowitz Y, Yu R, Mathuria N, Vaseghi M, Buch E, et al. Epicardial ablation of ventricular tachycardia: an institutional experience of safety and efficacy. Heart Rhythm. 2013;10:490–8.CrossRef Tung R, Michowitz Y, Yu R, Mathuria N, Vaseghi M, Buch E, et al. Epicardial ablation of ventricular tachycardia: an institutional experience of safety and efficacy. Heart Rhythm. 2013;10:490–8.CrossRef
17.
go back to reference Della Bella P, Brugada J, Zeppenfeld K, Merino J, Neuzil P, Maury P, et al. Epicardial ablation for ventricular tachycardia: a European multicenter study. Circ Arrhythm Electrophysiol. 2011;4:653–9.CrossRef Della Bella P, Brugada J, Zeppenfeld K, Merino J, Neuzil P, Maury P, et al. Epicardial ablation for ventricular tachycardia: a European multicenter study. Circ Arrhythm Electrophysiol. 2011;4:653–9.CrossRef
18.
go back to reference Lin CY, Chung FP, Lin YJ, Chang SL, Lo LW, Hu YF, et al. Safety and efficacy of epicardial ablation of ventricular tachyarrhythmias: experience from a tertiary referral center in Taiwan. Acta Cardiol Sin. 2018;34:49–58.PubMedPubMedCentral Lin CY, Chung FP, Lin YJ, Chang SL, Lo LW, Hu YF, et al. Safety and efficacy of epicardial ablation of ventricular tachyarrhythmias: experience from a tertiary referral center in Taiwan. Acta Cardiol Sin. 2018;34:49–58.PubMedPubMedCentral
19.
go back to reference Roberts-Thomson KC, Steven D, Seiler J, Inada K, Koplan BA, Tedrow UB, et al. Coronary artery injury due to catheter ablation in adults: presentations and outcomes. Circulation. 2009;120:1465–73.CrossRef Roberts-Thomson KC, Steven D, Seiler J, Inada K, Koplan BA, Tedrow UB, et al. Coronary artery injury due to catheter ablation in adults: presentations and outcomes. Circulation. 2009;120:1465–73.CrossRef
20.
go back to reference Schneider HE, Kriebel T, Gravenhorst VD, Paul T. Incidence of coronary artery injury immediately after catheter ablation for supraventricular tachycardias in infants and children. Heart Rhythm. 2009;6:461–7.CrossRef Schneider HE, Kriebel T, Gravenhorst VD, Paul T. Incidence of coronary artery injury immediately after catheter ablation for supraventricular tachycardias in infants and children. Heart Rhythm. 2009;6:461–7.CrossRef
21.
go back to reference Castano A, Crawford T, Yamazaki M, Avula UM, Kalifa J. Coronary artery pathophysiology after radiofrequency catheter ablation: review and perspectives. Heart Rhythm. 2011;8:1975–80.CrossRef Castano A, Crawford T, Yamazaki M, Avula UM, Kalifa J. Coronary artery pathophysiology after radiofrequency catheter ablation: review and perspectives. Heart Rhythm. 2011;8:1975–80.CrossRef
22.
go back to reference Killu AM, Naksuk N, Syed FF, DeSimone CV, Gaba P, Witt C, et al. Feasibility of directional percutaneous epicardial ablation with a partially insulated catheter. J Interv Card Electrophysiol. 2018;53:105–13.CrossRef Killu AM, Naksuk N, Syed FF, DeSimone CV, Gaba P, Witt C, et al. Feasibility of directional percutaneous epicardial ablation with a partially insulated catheter. J Interv Card Electrophysiol. 2018;53:105–13.CrossRef
23.
go back to reference Sosa E, Scanavacca M, d'Avila A, Pilleggi F. A new technique to perform epicardial mapping in the electrophysiology laboratory. J Cardiovasc Electrophysiol. 1996;7:531–6.CrossRef Sosa E, Scanavacca M, d'Avila A, Pilleggi F. A new technique to perform epicardial mapping in the electrophysiology laboratory. J Cardiovasc Electrophysiol. 1996;7:531–6.CrossRef
24.
go back to reference Ozturk E, Cansaran Tanidir I, Ayyildiz P, Gokalp S, Candas Kafali H, Sahin M, et al. The role of intraoperative epicardial echocardiography in pediatric cardiac surgery. Echocardiography (Mount Kisco, NY). 2018;35:999–1004.CrossRef Ozturk E, Cansaran Tanidir I, Ayyildiz P, Gokalp S, Candas Kafali H, Sahin M, et al. The role of intraoperative epicardial echocardiography in pediatric cardiac surgery. Echocardiography (Mount Kisco, NY). 2018;35:999–1004.CrossRef
25.
go back to reference Hiratzka LF, McPherson DD, Lamberth WC Jr, Brandt B 3rd, Armstrong ML, Schroder E, et al. Intraoperative evaluation of coronary artery bypass graft anastomoses with high-frequency epicardial echocardiography: experimental validation and initial patient studies. Circulation. 1986;73:1199–205.CrossRef Hiratzka LF, McPherson DD, Lamberth WC Jr, Brandt B 3rd, Armstrong ML, Schroder E, et al. Intraoperative evaluation of coronary artery bypass graft anastomoses with high-frequency epicardial echocardiography: experimental validation and initial patient studies. Circulation. 1986;73:1199–205.CrossRef
26.
go back to reference Matsuwaka R, Matsuda H, Nakano S, Hirata N, Nishimura M, Mitsuno M, et al. A new angled transducer for intraoperative epicardial echocardiography. Echocardiography (Mount Kisco, NY). 1991;8:341–3.CrossRef Matsuwaka R, Matsuda H, Nakano S, Hirata N, Nishimura M, Mitsuno M, et al. A new angled transducer for intraoperative epicardial echocardiography. Echocardiography (Mount Kisco, NY). 1991;8:341–3.CrossRef
27.
go back to reference Klein AL, Stewart WC, Cosgrove DM, Salcedo EE. Intraoperative epicardial echocardiography: technique and imaging planes. Echocardiography (Mount Kisco, NY). 1990;7:241–51.CrossRef Klein AL, Stewart WC, Cosgrove DM, Salcedo EE. Intraoperative epicardial echocardiography: technique and imaging planes. Echocardiography (Mount Kisco, NY). 1990;7:241–51.CrossRef
28.
go back to reference Stavrakis S, Jackman WM, Nakagawa H, Sun Y, Xu Q, Beckman KJ, et al. Risk of coronary artery injury with radiofrequency ablation and cryoablation of epicardial posteroseptal accessory pathways within the coronary venous system. Circ Arrhythm Electrophysiol. 2014;7:113–9.CrossRef Stavrakis S, Jackman WM, Nakagawa H, Sun Y, Xu Q, Beckman KJ, et al. Risk of coronary artery injury with radiofrequency ablation and cryoablation of epicardial posteroseptal accessory pathways within the coronary venous system. Circ Arrhythm Electrophysiol. 2014;7:113–9.CrossRef
29.
go back to reference Al Aloul B, Sigurdsson G, Adabag S, Li J-M, Dykoski R, Tholakanahalli VN. Atrial flutter ablation and risk of right coronary artery injury. J Clin Med Res. 2015;7:270–3.CrossRef Al Aloul B, Sigurdsson G, Adabag S, Li J-M, Dykoski R, Tholakanahalli VN. Atrial flutter ablation and risk of right coronary artery injury. J Clin Med Res. 2015;7:270–3.CrossRef
30.
go back to reference Caldwell JC, Fath-Odoubadi F, Garratt CJ. Right coronary artery damage during cavotricuspid isthmus ablation. Pacing Clin Electrophysiol: PACE. 2010;33:e110–3.CrossRef Caldwell JC, Fath-Odoubadi F, Garratt CJ. Right coronary artery damage during cavotricuspid isthmus ablation. Pacing Clin Electrophysiol: PACE. 2010;33:e110–3.CrossRef
31.
go back to reference Suresh A, Chang S-L, Lin Y-J, Lo L-W, Chung F-P, Chen S-A. Ablation of ventricular tachycardia arising from the great cardiac vein – a rare cause of coronary artery injury. Acta Cardiol Sin. 2017;33:553–5.PubMedPubMedCentral Suresh A, Chang S-L, Lin Y-J, Lo L-W, Chung F-P, Chen S-A. Ablation of ventricular tachycardia arising from the great cardiac vein – a rare cause of coronary artery injury. Acta Cardiol Sin. 2017;33:553–5.PubMedPubMedCentral
32.
go back to reference Demaria RG, Page P, Leung TK, Dubuc M, Malo O, Carrier M, et al. Surgical radiofrequency ablation induces coronary endothelial dysfunction in porcine coronary arteries. Eur J Cardio-Thoracic Surg. 2003;23:277–82.CrossRef Demaria RG, Page P, Leung TK, Dubuc M, Malo O, Carrier M, et al. Surgical radiofrequency ablation induces coronary endothelial dysfunction in porcine coronary arteries. Eur J Cardio-Thoracic Surg. 2003;23:277–82.CrossRef
33.
go back to reference Tavakol M, Ashraf S, Brener SJ. Risks and complications of coronary angiography: a comprehensive review. Global J Health Sci. 2012;4:65–93. Tavakol M, Ashraf S, Brener SJ. Risks and complications of coronary angiography: a comprehensive review. Global J Health Sci. 2012;4:65–93.
34.
go back to reference Baim DS, Grossman W. Cardiac catheterization, angiography and intervention. Philadelphia: Lippincott Williams & Wilkins; 1996. Baim DS, Grossman W. Cardiac catheterization, angiography and intervention. Philadelphia: Lippincott Williams & Wilkins; 1996.
35.
go back to reference Plourde G, Pancholy SB, Nolan J, Jolly S, Rao SV, Amhed I, et al. Radiation exposure in relation to the arterial access site used for diagnostic coronary angiography and percutaneous coronary intervention: a systematic review and meta-analysis. Lancet. 2015;386:2192–203.CrossRef Plourde G, Pancholy SB, Nolan J, Jolly S, Rao SV, Amhed I, et al. Radiation exposure in relation to the arterial access site used for diagnostic coronary angiography and percutaneous coronary intervention: a systematic review and meta-analysis. Lancet. 2015;386:2192–203.CrossRef
Metadata
Title
A novel percutaneous stabilizing sheath for minimal invasive epicardial echocardiography and ablation
Authors
Alan Sugrue
Vaibhav R. Vaidya
Deepak Padmanabhan
Omar Yasin
Anas Abudan
Ameesh Isath
Ammar M. Killu
Niyada Naksuk
Brad Bolon
Paul A. Friedman
Samuel J. Asirvatham
Publication date
01-04-2020
Publisher
Springer US
Published in
Journal of Interventional Cardiac Electrophysiology / Issue 3/2020
Print ISSN: 1383-875X
Electronic ISSN: 1572-8595
DOI
https://doi.org/10.1007/s10840-019-00553-8

Other articles of this Issue 3/2020

Journal of Interventional Cardiac Electrophysiology 3/2020 Go to the issue