Beta-blocker therapy is associated with a lower incidence of syncope due to fast ventricular tachycardias among implantable cardioverter-defibrillator patients with left ventricular dysfunction: results from a multicenter study

Authors: Javier Jiménez-Candil, Ignasi Anguera, Olga Durán, Jesús Hernández, Javier Fernández-Portales, José Luis Moríñigo, Ana Martín, Paolo Dallaglio, Loreto Bravo, Andrea di Marco, Pedro Luis Sánchez

Published in: Journal of Interventional Cardiac Electrophysiology | Issue 1/2018

Login to get access

Abstract

Introduction

Among implantable cardioverter-defibrillator (ICD) patients, a substantial proportion of syncopes are due to fast ventricular tachycardias (FVTs). In the experimental models of ventricular tachycardias, the arterial vasoconstriction plays an important role in recovering the arterial pressure. Since beta-blockers increase vascular resistance, we hypothesized that beta-blockers could reduce the occurrence of syncope due to FVTs. Our objective was to determine the relationship between the beta-blocker therapy and the incidence of syncope in FVT (cycle length [CL] 250–320 ms) occurring in ICD patients. Slow VTs were excluded because of the lack of symptoms and VF episodes because of the small number.

Methods and results

In this multicenter study, 226 patients (LVEF 31 ± 10%) with single-chamber ICDs were followed. FVT programming was standardized, including antitachycardia pacing (ATP) as initial therapy. Symptoms were correlated with ICD-stored episode data of FVTs. The beta-blocker therapy was determined at each FVT presentation. We analyzed 289 FVTs (CL 291 ± 21 ms; 77% under beta-blockers; median of the duration:8 s) occurring consecutively in 52 ICD patients. The frequency of FVT-related syncope was 22 (7.6%). Beta-blockers were associated with a lower heart rate preceding FVT (85 ± 22 vs. 94 ± 23 bpm; p = 0.009), a higher ATP effectiveness (86 vs. 57%; p < 0.001), a lower duration of episodes (8 [2] vs. 10 [14] s; p < 0.001), and a lower incidence of FVT-related syncope (4.5 vs. 18%; p < 0.001). By logistic regression, a FVT > 8 s (OR = 21; p = 0.003) and the beta-blocker therapy (OR = 0.3; p = 0.012) were found as independent predictors of syncope.

Conclusion

Among ICD patients with left ventricular dysfunction, beta-blockers are associated with a lower incidence of FVT-related syncope.
Literature
1.
go back to reference AVID Investigators. A comparison of antiarrhythmic-drug therapy with implantable defibrillators in patients resuscitated from near-fatal ventricular arrhythmias. The Antiarrhythmics versus Implantable Defibrillators (AVID) Investigators. N Engl J Med. 1997;337(22):1576–83.CrossRef AVID Investigators. A comparison of antiarrhythmic-drug therapy with implantable defibrillators in patients resuscitated from near-fatal ventricular arrhythmias. The Antiarrhythmics versus Implantable Defibrillators (AVID) Investigators. N Engl J Med. 1997;337(22):1576–83.CrossRef
2.
go back to reference Bardy GH, Lee KL, Mark DB, Poole JE, Packer DL, Boineau R, et al. Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure. N Engl J Med. 2005;352(3):225–37.CrossRefPubMed Bardy GH, Lee KL, Mark DB, Poole JE, Packer DL, Boineau R, et al. Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure. N Engl J Med. 2005;352(3):225–37.CrossRefPubMed
3.
go back to reference Moss AJ, Zareba W, Hall WJ, Klein H, Wilber DJ, Cannom DS, et al. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. N Engl J Med. 2002;346(12):877–83.CrossRefPubMed Moss AJ, Zareba W, Hall WJ, Klein H, Wilber DJ, Cannom DS, et al. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. N Engl J Med. 2002;346(12):877–83.CrossRefPubMed
5.
go back to reference Ruwald MH, Okumura K, Kimura T, Aonuma K, Shoda M, Kutyifa V, et al. Syncope in high-risk cardiomyopathy patients with implantable defibrillators: frequency, risk factors, mechanisms, and association with mortality: results from the multicenter automatic defibrillator implantation trial-reduce inappropriate therapy (MADIT-RIT) study. Circulation. 2014;129(5):545–52. https://doi.org/10.1161/CIRCULATIONAHA.113.004196.CrossRefPubMed Ruwald MH, Okumura K, Kimura T, Aonuma K, Shoda M, Kutyifa V, et al. Syncope in high-risk cardiomyopathy patients with implantable defibrillators: frequency, risk factors, mechanisms, and association with mortality: results from the multicenter automatic defibrillator implantation trial-reduce inappropriate therapy (MADIT-RIT) study. Circulation. 2014;129(5):545–52. https://​doi.​org/​10.​1161/​CIRCULATIONAHA.​113.​004196.CrossRefPubMed
7.
go back to reference Olatidoye AG, Verroneau J, Kluger J. Mechanisms of syncope in implantable cardioverter-defibrillator recipients who receive device therapies. Am J Cardiol. 1998;82(11):1372–6.CrossRefPubMed Olatidoye AG, Verroneau J, Kluger J. Mechanisms of syncope in implantable cardioverter-defibrillator recipients who receive device therapies. Am J Cardiol. 1998;82(11):1372–6.CrossRefPubMed
8.
go back to reference Jimenez-Candil J, Anguera I, Ledesma C, Fernandez-Portales J, Morinigo JL, Dallaglio P, et al. Morphology of far-field electrograms and antitachycardia pacing effectiveness among fast ventricular tachycardias occurring in ICD patients: a multicenter study. J Cardiovasc Electrophysiol. 2013;24(12):1375–82. https://doi.org/10.1111/jce.12228.CrossRefPubMed Jimenez-Candil J, Anguera I, Ledesma C, Fernandez-Portales J, Morinigo JL, Dallaglio P, et al. Morphology of far-field electrograms and antitachycardia pacing effectiveness among fast ventricular tachycardias occurring in ICD patients: a multicenter study. J Cardiovasc Electrophysiol. 2013;24(12):1375–82. https://​doi.​org/​10.​1111/​jce.​12228.CrossRefPubMed
9.
go back to reference Hutchinson TA, Shahan TR. DRUGDEXH system. Greenwood Village: MICROMEDEX; 2002. Hutchinson TA, Shahan TR. DRUGDEXH system. Greenwood Village: MICROMEDEX; 2002.
10.
go back to reference Jimenez-Candil J, Arenal A, Garcia-Alberola A, Ortiz M, del Castillo S, Fernandez-Portales J, et al. Fast ventricular tachycardias in patients with implantable cardioverter-defibrillators: efficacy and safety of antitachycardia pacing. A prospective and randomized study. J Am Coll Cardiol. 2005;45(3):460–1.CrossRefPubMed Jimenez-Candil J, Arenal A, Garcia-Alberola A, Ortiz M, del Castillo S, Fernandez-Portales J, et al. Fast ventricular tachycardias in patients with implantable cardioverter-defibrillators: efficacy and safety of antitachycardia pacing. A prospective and randomized study. J Am Coll Cardiol. 2005;45(3):460–1.CrossRefPubMed
11.
go back to reference Wathen MS, DeGroot PJ, Sweeney MO, Stark AJ, Otterness MF, Adkisson WO, et al. Prospective randomized multicenter trial of empirical antitachycardia pacing versus shocks for spontaneous rapid ventricular tachycardia in patients with implantable cardioverter-defibrillators: Pacing Fast Ventricular Tachycardia Reduces Shock Therapies (PainFREE Rx II) trial results. Circulation. 2004;110(17):2591–6.CrossRefPubMed Wathen MS, DeGroot PJ, Sweeney MO, Stark AJ, Otterness MF, Adkisson WO, et al. Prospective randomized multicenter trial of empirical antitachycardia pacing versus shocks for spontaneous rapid ventricular tachycardia in patients with implantable cardioverter-defibrillators: Pacing Fast Ventricular Tachycardia Reduces Shock Therapies (PainFREE Rx II) trial results. Circulation. 2004;110(17):2591–6.CrossRefPubMed
12.
go back to reference Hook BG, Marchlinski FE. Value of ventricular electrogram recordings in the diagnosis of arrhythmias precipitating electrical device shock therapy. J Am Coll Cardiol. 1991;17(4):985–90.CrossRefPubMed Hook BG, Marchlinski FE. Value of ventricular electrogram recordings in the diagnosis of arrhythmias precipitating electrical device shock therapy. J Am Coll Cardiol. 1991;17(4):985–90.CrossRefPubMed
13.
go back to reference Garcia-Alberola A, Yli-Mayry S, Block M, Haverkamp W, Martinez-Rubio A, Kottkamp H, et al. RR interval variability in irregular monomorphic ventricular tachycardia and atrial fibrillation. Circulation. 1996;93(2):295–300.CrossRefPubMed Garcia-Alberola A, Yli-Mayry S, Block M, Haverkamp W, Martinez-Rubio A, Kottkamp H, et al. RR interval variability in irregular monomorphic ventricular tachycardia and atrial fibrillation. Circulation. 1996;93(2):295–300.CrossRefPubMed
14.
go back to reference Swerdlow CD, Chen PS, Kass RM, Allard JR, Peter CT. Discrimination of ventricular tachycardia from sinus tachycardia and atrial fibrillation in a tiered-therapy cardioverter-defibrillator. J Am Coll Cardiol. 1994;23(6):1342–55.CrossRefPubMed Swerdlow CD, Chen PS, Kass RM, Allard JR, Peter CT. Discrimination of ventricular tachycardia from sinus tachycardia and atrial fibrillation in a tiered-therapy cardioverter-defibrillator. J Am Coll Cardiol. 1994;23(6):1342–55.CrossRefPubMed
15.
go back to reference Liang K, Zeger S. Longitudinal data analysis using generalized linear models. Biometrika. 1986;73:13–22.CrossRef Liang K, Zeger S. Longitudinal data analysis using generalized linear models. Biometrika. 1986;73:13–22.CrossRef
16.
go back to reference Kou WH, Calkins H, Lewis RR, Bolling SF, Kirsch MM, Langberg JJ, et al. Incidence of loss of consciousness during automatic implantable cardioverter-defibrillator shocks. Ann Intern Med. 1991;115(12):942–5.CrossRefPubMed Kou WH, Calkins H, Lewis RR, Bolling SF, Kirsch MM, Langberg JJ, et al. Incidence of loss of consciousness during automatic implantable cardioverter-defibrillator shocks. Ann Intern Med. 1991;115(12):942–5.CrossRefPubMed
18.
go back to reference Bansch D, Brunn J, Castrucci M, Weber M, Gietzen F, Borggrefe M, et al. Syncope in patients with an implantable cardioverter-defibrillator: Incidence, prediction and implications for driving restrictions. J Am Coll Cardiol. 1998;31(3):608–15.CrossRefPubMed Bansch D, Brunn J, Castrucci M, Weber M, Gietzen F, Borggrefe M, et al. Syncope in patients with an implantable cardioverter-defibrillator: Incidence, prediction and implications for driving restrictions. J Am Coll Cardiol. 1998;31(3):608–15.CrossRefPubMed
19.
go back to reference Grimm W, Flores BF, Marchlinski FE. Symptoms and electrocardiographically documented rhythm preceding spontaneous shocks in patients with implantable cardioverter-defibrillator. Am J Cardiol. 1993;71(16):1415–8.CrossRefPubMed Grimm W, Flores BF, Marchlinski FE. Symptoms and electrocardiographically documented rhythm preceding spontaneous shocks in patients with implantable cardioverter-defibrillator. Am J Cardiol. 1993;71(16):1415–8.CrossRefPubMed
21.
go back to reference Kouakam C, Lauwerier B, Klug D, Jarwe M, Marquie C, Lacroix D, et al. Effect of elevated heart rate preceding the onset of ventricular tachycardia on antitachycardia pacing effectiveness in patients with implantable cardioverter defibrillators. Am J Cardiol. 2003;92(1):26–32.CrossRefPubMed Kouakam C, Lauwerier B, Klug D, Jarwe M, Marquie C, Lacroix D, et al. Effect of elevated heart rate preceding the onset of ventricular tachycardia on antitachycardia pacing effectiveness in patients with implantable cardioverter defibrillators. Am J Cardiol. 2003;92(1):26–32.CrossRefPubMed
22.
go back to reference Jimenez-Candil J, Hernandez J, Martin A, Ruiz-Olgado M, Herrero J, Ledesma C, et al. Influence of beta-blocker therapy on antitachycardia pacing effectiveness for monomorphic ventricular tachycardias occurring in implantable cardioverter-defibrillator patients: a dose-dependent effect. Europace. 2010;12(9):1231–8. https://doi.org/10.1093/europace/euq164.CrossRefPubMed Jimenez-Candil J, Hernandez J, Martin A, Ruiz-Olgado M, Herrero J, Ledesma C, et al. Influence of beta-blocker therapy on antitachycardia pacing effectiveness for monomorphic ventricular tachycardias occurring in implantable cardioverter-defibrillator patients: a dose-dependent effect. Europace. 2010;12(9):1231–8. https://​doi.​org/​10.​1093/​europace/​euq164.CrossRefPubMed
23.
go back to reference Smith ML, Kinugawa T, Dibner-Dunlap ME. Reflex control of sympathetic activity during ventricular tachycardia in dogs: primary role of arterial baroreflexes. Circulation. 1996;93(5):1033–42.CrossRefPubMed Smith ML, Kinugawa T, Dibner-Dunlap ME. Reflex control of sympathetic activity during ventricular tachycardia in dogs: primary role of arterial baroreflexes. Circulation. 1996;93(5):1033–42.CrossRefPubMed
24.
go back to reference Karnik R, Valentin A, Slany J. Different effects of beta-1-adrenergic blocking agents with ISA or without ISA on peripheral blood flow. Angiology. 1987;38(4):296–303.CrossRefPubMed Karnik R, Valentin A, Slany J. Different effects of beta-1-adrenergic blocking agents with ISA or without ISA on peripheral blood flow. Angiology. 1987;38(4):296–303.CrossRefPubMed
25.
go back to reference Heusser K, Schobel HP, Adamidis A, Fischer T, Frank H. Cardiovascular effects of beta-blockers with and without intrinsic sympathomimetic activity. A comparison between celiprolol and metoprolol. Kidney Blood Press Res. 2002;25(1):34–41.CrossRefPubMed Heusser K, Schobel HP, Adamidis A, Fischer T, Frank H. Cardiovascular effects of beta-blockers with and without intrinsic sympathomimetic activity. A comparison between celiprolol and metoprolol. Kidney Blood Press Res. 2002;25(1):34–41.CrossRefPubMed
26.
go back to reference Matsumoto M, Inoue K, Moriki A. Associations of brachial-ankle pulse wave velocity and carotid atherosclerotic lesions with silent cerebral lesions. Hypertens Res. 2007;30(9):767–73.CrossRefPubMed Matsumoto M, Inoue K, Moriki A. Associations of brachial-ankle pulse wave velocity and carotid atherosclerotic lesions with silent cerebral lesions. Hypertens Res. 2007;30(9):767–73.CrossRefPubMed
Metadata
Title
Beta-blocker therapy is associated with a lower incidence of syncope due to fast ventricular tachycardias among implantable cardioverter-defibrillator patients with left ventricular dysfunction: results from a multicenter study
Authors
Javier Jiménez-Candil
Ignasi Anguera
Olga Durán
Jesús Hernández
Javier Fernández-Portales
José Luis Moríñigo
Ana Martín
Paolo Dallaglio
Loreto Bravo
Andrea di Marco
Pedro Luis Sánchez
Publication date
01-06-2018
Publisher
Springer US
Published in
Journal of Interventional Cardiac Electrophysiology / Issue 1/2018
Print ISSN: 1383-875X
Electronic ISSN: 1572-8595
DOI
https://doi.org/10.1007/s10840-018-0344-0

Other articles of this Issue 1/2018

Journal of Interventional Cardiac Electrophysiology 1/2018 Go to the issue