Skip to main content
Top
Published in: Journal of Interventional Cardiac Electrophysiology 1/2017

01-01-2017

Investigation of the atrial conduction time measured by tissue Doppler imaging at the left atrial appendage and the actual electrical conduction time: consideration of left atrial remodeling in atrial fibrillation patients

Authors: Yuichi Hori, Shiro Nakahara, Naofumi Anjo, Ayako Nakagawa, Naoki Nishiyama, Kouta Yamada, Akiko Hayashi, Takaaki Komatsu, Sayuki Kobayashi, Yoshihiko Sakai, Isao Taguchi

Published in: Journal of Interventional Cardiac Electrophysiology | Issue 1/2017

Login to get access

Abstract

Purpose

The atrial conduction time measured by echocardiography using tissue Doppler imaging (TDI) has been reported as a predictive factor of left atrial (LA) remodeling. We investigated the P wave to LA appendage (LAA) conduction time defined by transthoracic echocardiography using TDI (P-LAA TDI), and directly compared the actual LA electrical conduction time determined by the electrophysiological data. Additionally, we confirmed the clinical utility of the P-LAA TDI by examining the relationship to the electroanatomical LA remodeling data.

Methods

Sixty-three AF patients (22 paroxysmal AF, 41 persistent AF) underwent ablation and electroanatomical LA mapping. The P-LAA TDI was measured after the ablation and was compared with the electrophysiological data during sinus rhythm, including the actual electrical conduction time.

Results

A strong linear correlation (r = 0.776, p < 0.001, y = 1.28x + 49) was observed between the P-LAA TDI (161 ± 24 ms) and electrophysiological P-LAA time (87 ± 15 ms). The P-LAA TDI was also strongly correlated with the LA volume (173 ± 52 ml, r = 0.632, p < 0.001) and LA conduction velocity index (1.07 ± 0.19 mm/ms, r = −0.735, p < 0.001), but less to the focal anterior-LVA region surface area (2.2 [0.4-5.0] cm2, r = 0.380, p = 0.002). Additionally, a stepwise multiple linear regression demonstrated that both the LA volume and LA conduction velocity index were strongly associated with the value of the P-LAA TDI (p < 0.001).

Conclusions

The P-LAA TDI was useful for estimating the actual electrophysiological conduction time and represented both electrical and anatomical LA remodeling.
Literature
1.
go back to reference Haissaguerre M, Jais P, Shah DC, Takahashi A, Hocini M, Quiniou G, et al. Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. N Engl J Med. 1998;339:659–66.CrossRefPubMed Haissaguerre M, Jais P, Shah DC, Takahashi A, Hocini M, Quiniou G, et al. Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. N Engl J Med. 1998;339:659–66.CrossRefPubMed
2.
go back to reference Allessie MA, Boyden PA, Camm AJ, Kléber AG, Lab MJ, Legato MJ, et al. Pathophysiology and prevention of atrial fibrillation. Circulation. 2001;103:769–77.CrossRefPubMed Allessie MA, Boyden PA, Camm AJ, Kléber AG, Lab MJ, Legato MJ, et al. Pathophysiology and prevention of atrial fibrillation. Circulation. 2001;103:769–77.CrossRefPubMed
3.
go back to reference Latchamsetty R, Morady F. Long-term benefits following catheter ablation of atrial fibrillation. Circ J. 2013;77:1091–6.CrossRefPubMed Latchamsetty R, Morady F. Long-term benefits following catheter ablation of atrial fibrillation. Circ J. 2013;77:1091–6.CrossRefPubMed
4.
go back to reference Teh AW, Kistler PM, Lee G, Medi C, Heck PM, Spence SJ, et al. Electroanatomic remodeling of the left atrium in paroxysmal and persistent atrial fibrillation patients without structural heart disease. J Cardiovasc Electrophysiol. 2012;23:232–8.CrossRefPubMed Teh AW, Kistler PM, Lee G, Medi C, Heck PM, Spence SJ, et al. Electroanatomic remodeling of the left atrium in paroxysmal and persistent atrial fibrillation patients without structural heart disease. J Cardiovasc Electrophysiol. 2012;23:232–8.CrossRefPubMed
5.
go back to reference Rolf S, Kircher S, Arya A, Eitel C, Sommer P, Richter S, et al. Tailored atrial substrate modification based on low-voltage areas in catheter ablation of atrial fibrillation. Circ Arrhythm Electrophysiol. 2014;7(5):825–33.CrossRefPubMed Rolf S, Kircher S, Arya A, Eitel C, Sommer P, Richter S, et al. Tailored atrial substrate modification based on low-voltage areas in catheter ablation of atrial fibrillation. Circ Arrhythm Electrophysiol. 2014;7(5):825–33.CrossRefPubMed
6.
go back to reference Hori Y, Nakahara S, Kamijima T, Tsukada N, Hayashi A, Kobayashi S, et al. Influence of left atrium anatomical contact area in persistent atrial fibrillation-relationship between low-voltage area and fractionated electrogram. Circ J. 2014;78(8):1851–7.CrossRefPubMed Hori Y, Nakahara S, Kamijima T, Tsukada N, Hayashi A, Kobayashi S, et al. Influence of left atrium anatomical contact area in persistent atrial fibrillation-relationship between low-voltage area and fractionated electrogram. Circ J. 2014;78(8):1851–7.CrossRefPubMed
7.
go back to reference Fukamizu S, Sakurada H, Hayashi T, Hojo R, Komiyama K, Tanabe Y, et al. Macroreentrant atrial tachycardia in patients without previous atrial surgery or catheter ablation: clinical and electrophysiological characteristics of scar-related left atrial anterior wall reentry. J Cardiovasc Electrophysiol. 2013;24:404–12.CrossRefPubMed Fukamizu S, Sakurada H, Hayashi T, Hojo R, Komiyama K, Tanabe Y, et al. Macroreentrant atrial tachycardia in patients without previous atrial surgery or catheter ablation: clinical and electrophysiological characteristics of scar-related left atrial anterior wall reentry. J Cardiovasc Electrophysiol. 2013;24:404–12.CrossRefPubMed
8.
go back to reference Kinay O, Nazli C, Ergene O, Dogan A, Gedikli O, Hoscan Y, et al. Time interval from the initiation of the electrocardiographic P wave to the start of left atrial appendage ejection flow: a novel method for predicting atrial fibrillation recurrence. J Am Soc Echocardiogr. 2002;15:1479–84.CrossRefPubMed Kinay O, Nazli C, Ergene O, Dogan A, Gedikli O, Hoscan Y, et al. Time interval from the initiation of the electrocardiographic P wave to the start of left atrial appendage ejection flow: a novel method for predicting atrial fibrillation recurrence. J Am Soc Echocardiogr. 2002;15:1479–84.CrossRefPubMed
9.
go back to reference Merckx KL, De Vos CB, Palmans A, Habets J, Cheriex EC, Crijns HJ, et al. Atrial activation time determined by transthoracic Doppler tissue imaging can be used as an estimate of the total duration of atrial electrical activation. J Am Soc Echocardiogr. 2005;18:940–4.CrossRefPubMed Merckx KL, De Vos CB, Palmans A, Habets J, Cheriex EC, Crijns HJ, et al. Atrial activation time determined by transthoracic Doppler tissue imaging can be used as an estimate of the total duration of atrial electrical activation. J Am Soc Echocardiogr. 2005;18:940–4.CrossRefPubMed
10.
go back to reference Mano H, Okumura Y, Watanabe I, Masakatsu Ohta, Rikitake Kogawa, Naoko Sasaki, et al. Changes over time in echocardiographic variables and atrial electromechanical intervals after ablation for atrial fibrillation. J Arrhythm 2014; 466–472. Mano H, Okumura Y, Watanabe I, Masakatsu Ohta, Rikitake Kogawa, Naoko Sasaki, et al. Changes over time in echocardiographic variables and atrial electromechanical intervals after ablation for atrial fibrillation. J Arrhythm 2014; 466–472.
11.
go back to reference Park SM, Kim YH, Choi JI, Pak HN, Shim WJ. Left atrial electromechanical conduction time can predict six-month maintenance of sinus rhythm after electrical cardioversion in persistent atrial fibrillation by Doppler tissue echocardiography. J Am Soc Echocardiogr. 2010;23:309–14.CrossRefPubMed Park SM, Kim YH, Choi JI, Pak HN, Shim WJ. Left atrial electromechanical conduction time can predict six-month maintenance of sinus rhythm after electrical cardioversion in persistent atrial fibrillation by Doppler tissue echocardiography. J Am Soc Echocardiogr. 2010;23:309–14.CrossRefPubMed
12.
go back to reference Ejima K, Kato K, Arai K, Fukushima K, Fukushima N, Suzuki T, et al. Impact of atrial remodeling on the outcome of radiofrequency catheter ablation of paroxysmal atrial fibrillation. Circ J. 2014;78:872–7.CrossRefPubMed Ejima K, Kato K, Arai K, Fukushima K, Fukushima N, Suzuki T, et al. Impact of atrial remodeling on the outcome of radiofrequency catheter ablation of paroxysmal atrial fibrillation. Circ J. 2014;78:872–7.CrossRefPubMed
13.
go back to reference Muller P, Schiedat F, Bialek A, Bösche L, Ewers A, Kara K, et al. Total atrial conduction time assessed by tissue doppler imaging (PA-TDI Interval) to predict early recurrence of persistent atrial fibrillation after successful electrical cardioversion. J Cardiovasc Electrophysiol. 2014;25:161–7.CrossRefPubMed Muller P, Schiedat F, Bialek A, Bösche L, Ewers A, Kara K, et al. Total atrial conduction time assessed by tissue doppler imaging (PA-TDI Interval) to predict early recurrence of persistent atrial fibrillation after successful electrical cardioversion. J Cardiovasc Electrophysiol. 2014;25:161–7.CrossRefPubMed
14.
go back to reference Fujiwara M, Nakano Y, Hidaka T, Oda N, Uchimura Y, Sairaku A, et al. Prediction of atrial fibrillation after off-pump coronary artery bypass grafting using preoperative total atrial conduction time determined on tissue doppler imaging. Circ J. 2014;78:345–52.CrossRefPubMed Fujiwara M, Nakano Y, Hidaka T, Oda N, Uchimura Y, Sairaku A, et al. Prediction of atrial fibrillation after off-pump coronary artery bypass grafting using preoperative total atrial conduction time determined on tissue doppler imaging. Circ J. 2014;78:345–52.CrossRefPubMed
15.
go back to reference Uretsky S, Shah A, Bangalore S, Rosenberg L, Sarji R, Cantales DR, et al. Assessment of left atrial appendage function with transthoracic tissue Doppler echocardiography. Eur J Echocardiogr. 2009;10(3):363–71.CrossRefPubMed Uretsky S, Shah A, Bangalore S, Rosenberg L, Sarji R, Cantales DR, et al. Assessment of left atrial appendage function with transthoracic tissue Doppler echocardiography. Eur J Echocardiogr. 2009;10(3):363–71.CrossRefPubMed
16.
go back to reference Miyamoto K, Tsuchiya T, Narita S, Yamaguchi T, Nagamoto Y, Ando S, et al. Bipolar electrogram amplitudes in the left atrium are related to local conduction velocity in patients with atrial fibrillation. Europace. 2009;11:1597–605.CrossRefPubMed Miyamoto K, Tsuchiya T, Narita S, Yamaguchi T, Nagamoto Y, Ando S, et al. Bipolar electrogram amplitudes in the left atrium are related to local conduction velocity in patients with atrial fibrillation. Europace. 2009;11:1597–605.CrossRefPubMed
17.
go back to reference Jadidi AS, Cochet H, Shah AJ, Kim SJ, Duncan E, Miyazaki S, et al. Inverse relationship between fractionated electrograms and atrial fibrosis in persistent atrial fibrillation: combined magnetic resonance imaging and high-density mapping. J Am Coll Cardiol. 2013;62:802–12.CrossRefPubMed Jadidi AS, Cochet H, Shah AJ, Kim SJ, Duncan E, Miyazaki S, et al. Inverse relationship between fractionated electrograms and atrial fibrosis in persistent atrial fibrillation: combined magnetic resonance imaging and high-density mapping. J Am Coll Cardiol. 2013;62:802–12.CrossRefPubMed
18.
go back to reference Ling Z, McManigle J, Zipunnikov V, Pashakhanloo F, Khurram IM, Zimmerman SL, et al. The association of left atrial low-voltage regions on electroanatomic mapping with low attenuation regions on cardiac computed tomography perfusion imaging in patients with atrial fibrillation. Heart Rhythm. 2015;12(5):857–64.CrossRefPubMedPubMedCentral Ling Z, McManigle J, Zipunnikov V, Pashakhanloo F, Khurram IM, Zimmerman SL, et al. The association of left atrial low-voltage regions on electroanatomic mapping with low attenuation regions on cardiac computed tomography perfusion imaging in patients with atrial fibrillation. Heart Rhythm. 2015;12(5):857–64.CrossRefPubMedPubMedCentral
19.
go back to reference Chao TF, Sung SH, Wang KL, Lin YJ, Chang SL, Lo LW, et al. Associations between the atrial electromechanical interval, atrial remodelling and outcome of catheter ablation in paroxysmal atrial fibrillation. Heart. 2011;97(3):225–30.CrossRefPubMed Chao TF, Sung SH, Wang KL, Lin YJ, Chang SL, Lo LW, et al. Associations between the atrial electromechanical interval, atrial remodelling and outcome of catheter ablation in paroxysmal atrial fibrillation. Heart. 2011;97(3):225–30.CrossRefPubMed
20.
go back to reference den Uijl DW, Gawrysiak M, Tops LF, Trines SA, Zeppenfeld K, Schalij MJ, et al. Prognostic value of total atrial conduction time estimated with tissue Doppler imaging to predict the recurrence of atrial fibrillation after radiofrequency catheter ablation. Europace. 2011;13:1533–40.CrossRef den Uijl DW, Gawrysiak M, Tops LF, Trines SA, Zeppenfeld K, Schalij MJ, et al. Prognostic value of total atrial conduction time estimated with tissue Doppler imaging to predict the recurrence of atrial fibrillation after radiofrequency catheter ablation. Europace. 2011;13:1533–40.CrossRef
21.
go back to reference Akutsu Y, Kaneko K, Kodama Y, Suyama J, Li HL, Hamazaki Y, et al. Association between left and right atrial remodeling with atrial fibrillation recurrence after pulmonary vein catheter ablation in patients with paroxysmal atrial fibrillation: a pilot study. Circ Cardiovasc Imaging. 2011;4:524–31.CrossRefPubMed Akutsu Y, Kaneko K, Kodama Y, Suyama J, Li HL, Hamazaki Y, et al. Association between left and right atrial remodeling with atrial fibrillation recurrence after pulmonary vein catheter ablation in patients with paroxysmal atrial fibrillation: a pilot study. Circ Cardiovasc Imaging. 2011;4:524–31.CrossRefPubMed
22.
go back to reference Krul SP, Berger WR, Smit NW, van Amersfoorth SC, Driessen AH, van Boven WJ, et al. Atrial fibrosis and conduction slowing in the left atrial appendage of patients undergoing thoracoscopic surgical pulmonary vein isolation for atrial fibrillation. Circ Arrhythm Electrophysiol. 2015;8(2):288–95.CrossRefPubMed Krul SP, Berger WR, Smit NW, van Amersfoorth SC, Driessen AH, van Boven WJ, et al. Atrial fibrosis and conduction slowing in the left atrial appendage of patients undergoing thoracoscopic surgical pulmonary vein isolation for atrial fibrillation. Circ Arrhythm Electrophysiol. 2015;8(2):288–95.CrossRefPubMed
23.
go back to reference Nassif M, Krul SP, Driessen AH, Deneke T, Wilde AA, de Bakker JM, et al. Electrocardiographic P wave changes after thoracoscopic pulmonary vein isolation for atrial fibrillation. J Interv Card Electrophysiol. 2013;37(3):275–82.CrossRefPubMed Nassif M, Krul SP, Driessen AH, Deneke T, Wilde AA, de Bakker JM, et al. Electrocardiographic P wave changes after thoracoscopic pulmonary vein isolation for atrial fibrillation. J Interv Card Electrophysiol. 2013;37(3):275–82.CrossRefPubMed
Metadata
Title
Investigation of the atrial conduction time measured by tissue Doppler imaging at the left atrial appendage and the actual electrical conduction time: consideration of left atrial remodeling in atrial fibrillation patients
Authors
Yuichi Hori
Shiro Nakahara
Naofumi Anjo
Ayako Nakagawa
Naoki Nishiyama
Kouta Yamada
Akiko Hayashi
Takaaki Komatsu
Sayuki Kobayashi
Yoshihiko Sakai
Isao Taguchi
Publication date
01-01-2017
Publisher
Springer US
Published in
Journal of Interventional Cardiac Electrophysiology / Issue 1/2017
Print ISSN: 1383-875X
Electronic ISSN: 1572-8595
DOI
https://doi.org/10.1007/s10840-016-0185-7

Other articles of this Issue 1/2017

Journal of Interventional Cardiac Electrophysiology 1/2017 Go to the issue