Skip to main content
Top
Published in: Journal of Interventional Cardiac Electrophysiology 3/2014

01-12-2014

Electrophysiological study 6 months after Epicor high-intensity focused ultrasound atrial fibrillation ablation

Authors: Rodrigue Garcia, Frédéric Sacher, Pierre Oses, Nicolas Derval, Laurent Barandon, Arnaud Denis, Mélèze Hocini, Xavier Roques, Michel Haïssaguerre, Louis Labrousse, Pierre Jaïs

Published in: Journal of Interventional Cardiac Electrophysiology | Issue 3/2014

Login to get access

Abstract

Purpose

Little is presently known about the outcome of atrial lesions performed with high-intensity focused ultrasound (HIFU) for atrial fibrillation ablation. We aimed to assess endocardial atrial lesions 6 months after epicardial HIFU ablation (Epicor) and to evaluate the benefit of a combined ablation approach.

Methods

Thirty patients (21 males, mean age 68 ± 12 years old) undergoing HIFU atrial fibrillation ablation during cardiac surgery were enrolled. Electrophysiological study (EPS) was performed 6 months after HIFU ablation, and endovascular radiofrequency was delivered in case of conduction gaps. Patients were followed up for at least 6 months after the EPS.

Results

At EPS, ten patients (38 %) had achieved complete or near-complete “box” isolation and four (15 %) had no visible lesion. Using this technology, freedom from symptomatic atrial arrhythmia at 6 months was 60 % (n = 18/30) (64 % for paroxysmal and 56 % for persistent subgroups) improving to 81 % (n = 21/26) (90 % for paroxysmal and 73 % for persistent subgroups) at 12 months after a facultative percutaneous endocardial approach was performed. Using an UltraCinch device sized below 10 improved the rate of complete lesion as assessed 6 months after surgery (58 % of complete or near-complete box isolation with UltraCinch device <10 vs 21 % when ≥11; p = 0.05).

Conclusion

Six months after HIFU ablation, only 38 % of the patients had complete or near-complete box isolation, and the recurrence rate of symptomatic atrial arrhythmia was 40 %. The latter was reduced to 19 % 6 months after complementary percutaneous approach.
Literature
1.
go back to reference Camm, A. J., Lip, G. Y., De Caterina, R., Savelieva, I., Atar, D., Hohnloser, S. H., et al. (2012). 2012 focused update of the ESC Guidelines for the management of atrial fibrillation: an update of the 2010 ESC Guidelines for the management of atrial fibrillation developed with the special contribution of the European Heart Rhythm Association. European Heart Journal, 33(21), 2719–2747.PubMedCrossRef Camm, A. J., Lip, G. Y., De Caterina, R., Savelieva, I., Atar, D., Hohnloser, S. H., et al. (2012). 2012 focused update of the ESC Guidelines for the management of atrial fibrillation: an update of the 2010 ESC Guidelines for the management of atrial fibrillation developed with the special contribution of the European Heart Rhythm Association. European Heart Journal, 33(21), 2719–2747.PubMedCrossRef
2.
go back to reference Ngaage, D. L., Schaff, H. V., Barnes, S. A., Sundt, T. M., Mullany, C. J., Dearani, J. A., et al. (2006). Prognostic implications of preoperative atrial fibrillation in patients undergoing aortic valve replacement: is there an argument for concomitant arrhythmia surgery? The Annals of Thoracic Surgery, 82(4), 1392–1399.PubMedCrossRef Ngaage, D. L., Schaff, H. V., Barnes, S. A., Sundt, T. M., Mullany, C. J., Dearani, J. A., et al. (2006). Prognostic implications of preoperative atrial fibrillation in patients undergoing aortic valve replacement: is there an argument for concomitant arrhythmia surgery? The Annals of Thoracic Surgery, 82(4), 1392–1399.PubMedCrossRef
3.
go back to reference Cox, J. L., Schuessler, R. B., Lappas, D. G., & Boineau, J. P. (1996). An 8 1/2-year clinical experience with surgery for atrial fibrillation. Annals of Surgery, 224(3), 267–273. discussion 273–275.PubMedCentralPubMedCrossRef Cox, J. L., Schuessler, R. B., Lappas, D. G., & Boineau, J. P. (1996). An 8 1/2-year clinical experience with surgery for atrial fibrillation. Annals of Surgery, 224(3), 267–273. discussion 273–275.PubMedCentralPubMedCrossRef
4.
go back to reference Ninet, J., Roques, X., Seitelberger, R., Deville, C., Pomar, J. L., Robin, J., et al. (2005). Surgical ablation of atrial fibrillation with off-pump, epicardial, high-intensity focused ultrasound: results of a multicenter trial. The Journal of Thoracic and Cardiovascular Surgery, 130(3), 803–809.PubMedCrossRef Ninet, J., Roques, X., Seitelberger, R., Deville, C., Pomar, J. L., Robin, J., et al. (2005). Surgical ablation of atrial fibrillation with off-pump, epicardial, high-intensity focused ultrasound: results of a multicenter trial. The Journal of Thoracic and Cardiovascular Surgery, 130(3), 803–809.PubMedCrossRef
5.
go back to reference Groh, M. A., Binns, O. A., Burton, H. G., Ely, S. W., & Johnson, A. M. (2007). Ultrasonic cardiac ablation for atrial fibrillation during concomitant cardiac surgery: long-term clinical outcomes. The Annals of Thoracic Surgery, 84(6), 1978–1983.PubMedCrossRef Groh, M. A., Binns, O. A., Burton, H. G., Ely, S. W., & Johnson, A. M. (2007). Ultrasonic cardiac ablation for atrial fibrillation during concomitant cardiac surgery: long-term clinical outcomes. The Annals of Thoracic Surgery, 84(6), 1978–1983.PubMedCrossRef
6.
go back to reference Schopka, S., Schmid, C., Keyser, A., Kortner, A., Tafelmeier, J., Diez, C., et al. (2010). Ablation of atrial fibrillation with the Epicor system: a prospective observational trial to evaluate safety and efficacy and predictors of success. Journal of Cardiothoracic Surgery, 5(34), 5–34. Schopka, S., Schmid, C., Keyser, A., Kortner, A., Tafelmeier, J., Diez, C., et al. (2010). Ablation of atrial fibrillation with the Epicor system: a prospective observational trial to evaluate safety and efficacy and predictors of success. Journal of Cardiothoracic Surgery, 5(34), 5–34.
7.
go back to reference McCarthy, P., Kruse, J., Shalli, S., Ilkhanoff, I., Goldberger, J. J., Kadish, A. H., et al. (2010). Where does atrial fibrillation surgery fail? Implications for increasing effectiveness of ablation. The Journal of Thoracic and Cardiovascular Surgery, 139(4), 860–867.PubMedCrossRef McCarthy, P., Kruse, J., Shalli, S., Ilkhanoff, I., Goldberger, J. J., Kadish, A. H., et al. (2010). Where does atrial fibrillation surgery fail? Implications for increasing effectiveness of ablation. The Journal of Thoracic and Cardiovascular Surgery, 139(4), 860–867.PubMedCrossRef
8.
go back to reference Villamizar, N. R., Crow, J. H., Piacentino, V., DiBernardo, L. R., Daneshmand, M. A., Bowles, D. E., et al. (2010). Reproducibility of left atrial ablation with high-intensity focused ultrasound energy in a calf model. The Journal of Thoracic and Cardiovascular Surgery, 140(6), 1381–13877.PubMedCentralPubMedCrossRef Villamizar, N. R., Crow, J. H., Piacentino, V., DiBernardo, L. R., Daneshmand, M. A., Bowles, D. E., et al. (2010). Reproducibility of left atrial ablation with high-intensity focused ultrasound energy in a calf model. The Journal of Thoracic and Cardiovascular Surgery, 140(6), 1381–13877.PubMedCentralPubMedCrossRef
9.
go back to reference Vanelli, P., Lemma, M., & Antona, C. (2010). Right mini-thoracotomy for left maze with transesophageal echo guidance. Interactive Cardiovascular and Thoracic Surgery, 10(6), 843–846.PubMedCrossRef Vanelli, P., Lemma, M., & Antona, C. (2010). Right mini-thoracotomy for left maze with transesophageal echo guidance. Interactive Cardiovascular and Thoracic Surgery, 10(6), 843–846.PubMedCrossRef
10.
go back to reference Klinkenberg, T. J., Ahmed, S., Hagen, A. T., Wiesfeld, A. C., Tan, E. S., Zijlstra, F., et al. (2009). Feasibility and outcome of epicardial pulmonary vein isolation for lone atrial fibrillation using minimal invasive surgery and high intensity focused ultrasound. Europace, 11(12), 1624–1631.PubMedCrossRef Klinkenberg, T. J., Ahmed, S., Hagen, A. T., Wiesfeld, A. C., Tan, E. S., Zijlstra, F., et al. (2009). Feasibility and outcome of epicardial pulmonary vein isolation for lone atrial fibrillation using minimal invasive surgery and high intensity focused ultrasound. Europace, 11(12), 1624–1631.PubMedCrossRef
11.
go back to reference Pozzoli, A., Benussi, S., Anzil, F., Taramasso, F., Privitera, Y. A., Cianflone, D., et al. (2012). Electrophysiological efficacy of Epicor high-intensity focused ultrasound. European Journal of Cardiothoracic Surgery, 42(1), 129–134.PubMedCrossRef Pozzoli, A., Benussi, S., Anzil, F., Taramasso, F., Privitera, Y. A., Cianflone, D., et al. (2012). Electrophysiological efficacy of Epicor high-intensity focused ultrasound. European Journal of Cardiothoracic Surgery, 42(1), 129–134.PubMedCrossRef
12.
go back to reference Cappato, R., Negroni, S., Pecora, D., Bentivegna, S., Lupo, P. P., Carolei, A., et al. (2003). Prospective assessment of late conduction recurrence across radiofrequency lesions producing electrical disconnection at the pulmonary vein ostium in patients with atrial fibrillation. Circulation, 108(13), 1599–1604.PubMedCrossRef Cappato, R., Negroni, S., Pecora, D., Bentivegna, S., Lupo, P. P., Carolei, A., et al. (2003). Prospective assessment of late conduction recurrence across radiofrequency lesions producing electrical disconnection at the pulmonary vein ostium in patients with atrial fibrillation. Circulation, 108(13), 1599–1604.PubMedCrossRef
13.
go back to reference Gaita, F., Riccardi, R., Caponi, D., Shah, D. E., Garberoglio, L., & Vivalda, L. (2005). Linear cryoablation of the left atrium versus pulmonary vein cryoisolation in patients with permanent atrial fibrillation and valvular heart disease: correlation of electroanatomic mapping and long-term clinical results. Circulation, 111(2), 136–142.PubMedCrossRef Gaita, F., Riccardi, R., Caponi, D., Shah, D. E., Garberoglio, L., & Vivalda, L. (2005). Linear cryoablation of the left atrium versus pulmonary vein cryoisolation in patients with permanent atrial fibrillation and valvular heart disease: correlation of electroanatomic mapping and long-term clinical results. Circulation, 111(2), 136–142.PubMedCrossRef
Metadata
Title
Electrophysiological study 6 months after Epicor™ high-intensity focused ultrasound atrial fibrillation ablation
Authors
Rodrigue Garcia
Frédéric Sacher
Pierre Oses
Nicolas Derval
Laurent Barandon
Arnaud Denis
Mélèze Hocini
Xavier Roques
Michel Haïssaguerre
Louis Labrousse
Pierre Jaïs
Publication date
01-12-2014
Publisher
Springer US
Published in
Journal of Interventional Cardiac Electrophysiology / Issue 3/2014
Print ISSN: 1383-875X
Electronic ISSN: 1572-8595
DOI
https://doi.org/10.1007/s10840-014-9949-0

Other articles of this Issue 3/2014

Journal of Interventional Cardiac Electrophysiology 3/2014 Go to the issue