Purpose

Several time-lapse imaging (TLI) systems for non-invasive continuous monitoring of developing embryos are currently available. The present study explored the prevalence, means of acquisition, and clinical application of TLI systems in USA in vitro fertilization (IVF) laboratories.

Methods

An online cross-sectional survey of 294 USA IVF laboratory directors was conducted in February and March 2016. Those directing more than one laboratory were asked to complete the survey for their home program and for their smallest laboratory by number of IVF/intracytoplasmic sperm injection (ICSI) cycle starts. Use of TLI was analyzed using logistic regression to calculate odds ratios (OR).

Results

Of 294 directors surveyed, 162 (55%) reported data on 204 laboratories. Thirty-five laboratories (17%) possessed at least one TLI system (median 2, interquartile range 1–4, total range 1–11). The more oocyte retrievals a laboratory performed annually, the more likely the laboratory was to possess a TLI system. Fifteen laboratories (43%) purchased their own systems, while others leased, loaned, or received donated systems. Twenty-five laboratories (71%) reported using TLI for embryo selection; all used TLI always, or usually, in combination with standard morphology evaluation. Twenty laboratories (80%) offered TLI to all patients. Some laboratories charged patients for TLI. Directors with TLI systems were more inclined to believe that TLI has value for embryo selection in clinical IVF.

Conclusions

TLI system possession in USA IVF laboratories is low, although positively associated with the number of retrievals performed and with directors’ opinions on the technology’s utility. Over 70% of laboratories with TLI systems use them clinically, and less than half purchased their systems.
Literature
3.
go back to reference Wong CC, Loewke KE, Bossert NL, Behr B, De Jonge CJ, Baer TM, et al. Non-invasive imaging of human embryos before embryonic genome activation predicts development to the blastocyst stage. Nat Biotechnol. 2010;28(10):1115–21. doi:10.1038/nbt.1686.CrossRefPubMed Wong CC, Loewke KE, Bossert NL, Behr B, De Jonge CJ, Baer TM, et al. Non-invasive imaging of human embryos before embryonic genome activation predicts development to the blastocyst stage. Nat Biotechnol. 2010;28(10):1115–21. doi:10.​1038/​nbt.​1686.CrossRefPubMed
4.
7.
go back to reference Desai N, Ploskonka S, Goodman L, Austin C, Goldberg J, Falcone T. Analysis of embryo morphokinetics, multinucleation and cleavage anomalies using continuous time-lapse monitoring in blastocyst transfer cycles. Reprod Biol Endocrinol. 2014;12(1):54.CrossRefPubMedPubMedCentral Desai N, Ploskonka S, Goodman L, Austin C, Goldberg J, Falcone T. Analysis of embryo morphokinetics, multinucleation and cleavage anomalies using continuous time-lapse monitoring in blastocyst transfer cycles. Reprod Biol Endocrinol. 2014;12(1):54.CrossRefPubMedPubMedCentral
8.
go back to reference Conaghan J, Chen AA, Willman SP, Ivani K, Chenette PE, Boostanfar R, et al. Improving embryo selection using a computer-automated time-lapse image analysis test plus day 3 morphology: results from a prospective multicenter trial. Fertil Steril. 2013;100(2):412–419 e5. doi:10.1016/j.fertnstert.2013.04.021.CrossRefPubMed Conaghan J, Chen AA, Willman SP, Ivani K, Chenette PE, Boostanfar R, et al. Improving embryo selection using a computer-automated time-lapse image analysis test plus day 3 morphology: results from a prospective multicenter trial. Fertil Steril. 2013;100(2):412–419 e5. doi:10.​1016/​j.​fertnstert.​2013.​04.​021.CrossRefPubMed
9.
go back to reference Kirkegaard K, Kesmodel US, Hindkjaer JJ, Ingerslev HJ. Time-lapse parameters as predictors of blastocyst development and pregnancy outcome in embryos from good prognosis patients: a prospective cohort study. Hum Reprod. 2013;28(10):2643–51. doi:10.1093/humrep/det300.CrossRefPubMed Kirkegaard K, Kesmodel US, Hindkjaer JJ, Ingerslev HJ. Time-lapse parameters as predictors of blastocyst development and pregnancy outcome in embryos from good prognosis patients: a prospective cohort study. Hum Reprod. 2013;28(10):2643–51. doi:10.​1093/​humrep/​det300.CrossRefPubMed
10.
go back to reference Aparicio-Ruiz B, Basile N, Perez Albala S, Bronet F, Remohi J, Meseguer M. Automatic time-lapse instrument is superior to single-point morphology observation for selecting viable embryos: retrospective study in oocyte donation. Fertil Steril. 2016 Nov;106(6):1379-1385.e10. doi:10.1016/j.fertnstert.2016.07.1117. Aparicio-Ruiz B, Basile N, Perez Albala S, Bronet F, Remohi J, Meseguer M. Automatic time-lapse instrument is superior to single-point morphology observation for selecting viable embryos: retrospective study in oocyte donation. Fertil Steril. 2016 Nov;106(6):1379-1385.e10. doi:10.​1016/​j.​fertnstert.​2016.​07.​1117.
11.
go back to reference Diamond MP, Suraj V, Behnke EJ, Yang X, Angle MJ, Lambe-Steinmiller JC, et al. Using the Eeva test adjunctively to traditional day 3 morphology is informative for consistent embryo assessment within a panel of embryologists with diverse experience. J Assist Reprod Genet. 2015;32(1):61–8. doi:10.1007/s10815-014-0366-1.CrossRefPubMed Diamond MP, Suraj V, Behnke EJ, Yang X, Angle MJ, Lambe-Steinmiller JC, et al. Using the Eeva test adjunctively to traditional day 3 morphology is informative for consistent embryo assessment within a panel of embryologists with diverse experience. J Assist Reprod Genet. 2015;32(1):61–8. doi:10.​1007/​s10815-014-0366-1.CrossRefPubMed
15.
go back to reference Meseguer M, Rubio I, Cruz M, Basile N, Marcos J, Requena A. Embryo incubation and selection in a time-lapse monitoring system improves pregnancy outcome compared with a standard incubator: a retrospective cohort study. Fertil Steril. 2012;98(6):1481–1489 e10. doi:10.1016/j.fertnstert.2012.08.016.CrossRefPubMed Meseguer M, Rubio I, Cruz M, Basile N, Marcos J, Requena A. Embryo incubation and selection in a time-lapse monitoring system improves pregnancy outcome compared with a standard incubator: a retrospective cohort study. Fertil Steril. 2012;98(6):1481–1489 e10. doi:10.​1016/​j.​fertnstert.​2012.​08.​016.CrossRefPubMed
17.
go back to reference Cetinkaya M, Pirkevi C, Yelke H, Colakoglu YK, Atayurt Z, Kahraman S. Relative kinetic expressions defining cleavage synchronicity are better predictors of blastocyst formation and quality than absolute time points. J Assist Reprod Genet. 2015;32(1):27–35. doi:10.1007/s10815-014-0341-x.CrossRefPubMed Cetinkaya M, Pirkevi C, Yelke H, Colakoglu YK, Atayurt Z, Kahraman S. Relative kinetic expressions defining cleavage synchronicity are better predictors of blastocyst formation and quality than absolute time points. J Assist Reprod Genet. 2015;32(1):27–35. doi:10.​1007/​s10815-014-0341-x.CrossRefPubMed
19.
go back to reference Kahraman S, Çetinkaya M, Pirkevi C, Yelke H, Kumtepe Y. Comparison of blastocyst development and cycle outcome in patients with eSET using either conventional or time lapse incubators. A prospective study of good prognosis patients. J Reprod Biotechnol Fertil. 2012;3(2):55–61. doi:10.1177/205891581200300204. Kahraman S, Çetinkaya M, Pirkevi C, Yelke H, Kumtepe Y. Comparison of blastocyst development and cycle outcome in patients with eSET using either conventional or time lapse incubators. A prospective study of good prognosis patients. J Reprod Biotechnol Fertil. 2012;3(2):55–61. doi:10.​1177/​2058915812003002​04.
20.
go back to reference Kaser DJ, Bormann CL, Missmer SA, Farland LV, Ginsburg ES, Racowsky C. Eeva™ pregnancy pilot study: a randomized controlled trial of single embryo transfer (SET) on day 3 or day 5 with or without time-lapse imaging (TLI) selection. Fertil Steril. 106(3):e312. doi: 10.1016/j.fertnstert.2016.07.886. Kaser DJ, Bormann CL, Missmer SA, Farland LV, Ginsburg ES, Racowsky C. Eeva™ pregnancy pilot study: a randomized controlled trial of single embryo transfer (SET) on day 3 or day 5 with or without time-lapse imaging (TLI) selection. Fertil Steril. 106(3):e312. doi: 10.​1016/​j.​fertnstert.​2016.​07.​886.
22.
go back to reference Armstrong S, Arroll N, Cree LM, Jordan V, Farquhar C. Time-lapse systems for embryo incubation and assessment in assisted reproduction. The Cochrane database of systematic reviews. 2015(2):Cd011320. doi:10.1002/14651858.CD011320. Armstrong S, Arroll N, Cree LM, Jordan V, Farquhar C. Time-lapse systems for embryo incubation and assessment in assisted reproduction. The Cochrane database of systematic reviews. 2015(2):Cd011320. doi:10.​1002/​14651858.​CD011320.
23.
go back to reference Polanski LT, Coelho Neto MA, Nastri CO, Navarro PA, Ferriani RA, Raine-Fenning N, et al. Time-lapse embryo imaging for improving reproductive outcomes: systematic review and meta-analysis. Ultrasound Obstet Gynecol : Off J Int Soc Ultrasound Obstet Gynecol. 2014;44(4):394–401. doi:10.1002/uog.13428.CrossRef Polanski LT, Coelho Neto MA, Nastri CO, Navarro PA, Ferriani RA, Raine-Fenning N, et al. Time-lapse embryo imaging for improving reproductive outcomes: systematic review and meta-analysis. Ultrasound Obstet Gynecol : Off J Int Soc Ultrasound Obstet Gynecol. 2014;44(4):394–401. doi:10.​1002/​uog.​13428.CrossRef
Metadata
Title
National survey on use of time-lapse imaging systems in IVF laboratories
Authors
Andrey V. Dolinko
L. V. Farland
D. J. Kaser
S. A. Missmer
C. Racowsky
Publication date
01-09-2017
Publisher
Springer US
Published in
Journal of Assisted Reproduction and Genetics / Issue 9/2017
Print ISSN: 1058-0468
Electronic ISSN: 1573-7330
DOI
https://doi.org/10.1007/s10815-017-0964-9

Other articles of this Issue 9/2017

Journal of Assisted Reproduction and Genetics 9/2017 Go to the issue