Keratometry with five different techniques: a study of device repeatability and inter-device agreement

Authors: Shiva Mehravaran, Soheila Asgari, Sara Bigdeli, Ashkan Shahnazi, Hassan Hashemi

Published in: International Ophthalmology | Issue 4/2014

Login to get access

Abstract

The purpose of this study was to determine and compare the repeatability of keratometry measurements with the Javal manual keratometer, Topcon automated kerato-refractometer, IOLMaster, EyeSys Corneal Analysis System, and Pentacam Scheimpflug Topography System, and determine the agreement of measurements of the latter four devices with the Javal keratometer as the gold standard. In this cross-sectional study, 21 people with no history of ocular disease or surgery were examined twice with each device. Minimum, maximum, and average keratometry readings were recorded in diopters (D) for each eye and used in the analyses. For statistical analysis, we determined correlation coefficients and used the Bland–Altman method and calculated the 95 % limits of agreement (LoA). All repeatability coefficients were satisfactorily high. Best repeatability for minimum keratometry and maximum keratometry readings was seen with IOLMaster (95 % LoA −0.23 to 0.19 D and −0.31 to 0.32 D, respectively). Agreement with Javal manual keratometry was best with Topcon and IOLMaster for minimum keratometry readings (95 % LoA −0.67 to 0.28 D and −0.57 to 0.38 D, respectively), and with Topcon for maximum keratometry readings (95 % LoA −0.85 to 0.63 D). In our series of normal eyes, keratometry readings with Topcon, IOLMaster, and Pentacam showed very good agreement with Javal measurements, and inter-device agreements were better than the repeatability of the manual gold standard. However, differences between Javal and EyeSys may not be clinically acceptable, and these two devices should not be used interchangeably. Further studies are needed to investigate these issues in non-virgin eyes.
Literature
1.
go back to reference Sahin A, Yildirim N, Basmak H (2008) Two-year interval changes in Orbscan II topography in eyes with keratoconus. J Cataract Refract Surg 34:1295–1299PubMedCrossRef Sahin A, Yildirim N, Basmak H (2008) Two-year interval changes in Orbscan II topography in eyes with keratoconus. J Cataract Refract Surg 34:1295–1299PubMedCrossRef
2.
go back to reference Kohnen T, Koch DD (2009) Cataract and refractive surgery: Progress III. Springer, HeidelbergCrossRef Kohnen T, Koch DD (2009) Cataract and refractive surgery: Progress III. Springer, HeidelbergCrossRef
3.
go back to reference Haigis W (2008) Intraocular lens calculation after refractive surgery for myopia: Haigis-L formula. J Cataract Refract Surg 34:1658–1663PubMedCrossRef Haigis W (2008) Intraocular lens calculation after refractive surgery for myopia: Haigis-L formula. J Cataract Refract Surg 34:1658–1663PubMedCrossRef
4.
go back to reference Aristodemou P, Knox Cartwright NE, Sparrow JM, Johnston RL (2011) Formula choice: Hoffer Q, Holladay 1, or SRK/T and refractive outcomes in 8,108 eyes after cataract surgery with biometry by partial coherence interferometry. J Cataract Refract Surg 37:63–71PubMedCrossRef Aristodemou P, Knox Cartwright NE, Sparrow JM, Johnston RL (2011) Formula choice: Hoffer Q, Holladay 1, or SRK/T and refractive outcomes in 8,108 eyes after cataract surgery with biometry by partial coherence interferometry. J Cataract Refract Surg 37:63–71PubMedCrossRef
5.
go back to reference Hosny M, Alio JL, Claramonte P, Attia WH, Perez-Santonja JJ (2000) Relationship between anterior chamber depth, refractive state, corneal diameter, and axial length. J Refract Surg 16:336–340PubMed Hosny M, Alio JL, Claramonte P, Attia WH, Perez-Santonja JJ (2000) Relationship between anterior chamber depth, refractive state, corneal diameter, and axial length. J Refract Surg 16:336–340PubMed
6.
go back to reference Holzer MP, Mamusa M, Auffarth GU (2009) Accuracy of a new partial coherence interferometry analyser for biometric measurements. Br J Ophthalmol 93:807–810PubMedCrossRef Holzer MP, Mamusa M, Auffarth GU (2009) Accuracy of a new partial coherence interferometry analyser for biometric measurements. Br J Ophthalmol 93:807–810PubMedCrossRef
7.
go back to reference Tennen DG, Keates RH, Montoya C (1995) Comparison of three keratometry instruments. J Cataract Refract Surg 21:407–408PubMedCrossRef Tennen DG, Keates RH, Montoya C (1995) Comparison of three keratometry instruments. J Cataract Refract Surg 21:407–408PubMedCrossRef
8.
go back to reference Tsilimbaris MK, Vlachonikolis IG, Siganos D, Makridakis G, Pallikaris IG (1991) Comparison of keratometric readings as obtained by Javal Ophthalmometer and Corneal Analysis System (EyeSys). Refract Corneal Surg 7:368–373PubMed Tsilimbaris MK, Vlachonikolis IG, Siganos D, Makridakis G, Pallikaris IG (1991) Comparison of keratometric readings as obtained by Javal Ophthalmometer and Corneal Analysis System (EyeSys). Refract Corneal Surg 7:368–373PubMed
9.
10.
go back to reference Mihaltz K, Kovacs I, Takacs A, Nagy ZZ (2009) Evaluation of keratometric, pachymetric, and elevation parameters of keratoconic corneas with pentacam. Cornea 28:976–980PubMedCrossRef Mihaltz K, Kovacs I, Takacs A, Nagy ZZ (2009) Evaluation of keratometric, pachymetric, and elevation parameters of keratoconic corneas with pentacam. Cornea 28:976–980PubMedCrossRef
11.
go back to reference Hashemi H, Mehravaran S, Rezvan F (2010) Changes in corneal thickness, curvature, and anterior chamber depth during the menstrual cycle. Can J Ophthalmol 45:67–70PubMedCrossRef Hashemi H, Mehravaran S, Rezvan F (2010) Changes in corneal thickness, curvature, and anterior chamber depth during the menstrual cycle. Can J Ophthalmol 45:67–70PubMedCrossRef
12.
go back to reference Muller R, Buttner P (1994) A critical discussion of intraclass correlation coefficients. Stat Med 13:2465–2476PubMedCrossRef Muller R, Buttner P (1994) A critical discussion of intraclass correlation coefficients. Stat Med 13:2465–2476PubMedCrossRef
13.
go back to reference Kramer MS, Feinstein AR (1981) Clinical biostatistics. LIV. The biostatistics of concordance. Clin Pharmacol Ther 29:111–123PubMedCrossRef Kramer MS, Feinstein AR (1981) Clinical biostatistics. LIV. The biostatistics of concordance. Clin Pharmacol Ther 29:111–123PubMedCrossRef
14.
go back to reference Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307–310PubMedCrossRef Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307–310PubMedCrossRef
15.
go back to reference Khurana AK (2008) Theory and practice of optics and refraction. Elsevier India, Chennai Khurana AK (2008) Theory and practice of optics and refraction. Elsevier India, Chennai
16.
go back to reference Fowler CW (1989) Assessment of toroidal surfaces by the measurement of curvature in three fixed meridians. Ophthalmic Physiol Opt 9:79–80PubMedCrossRef Fowler CW (1989) Assessment of toroidal surfaces by the measurement of curvature in three fixed meridians. Ophthalmic Physiol Opt 9:79–80PubMedCrossRef
17.
go back to reference Roy H, Hill WE (2012) IOLMaster for determining the IOL power at the time of surgery. In: Agarwal A, Jacob S (eds) Phacoemulsification. Jaypee Brothers Medical Publications, New Delhi, p 62 Roy H, Hill WE (2012) IOLMaster for determining the IOL power at the time of surgery. In: Agarwal A, Jacob S (eds) Phacoemulsification. Jaypee Brothers Medical Publications, New Delhi, p 62
19.
go back to reference Koch DD, Foulks GN, Moran CT, Wakil JS (1989) The Corneal EyeSys System: accuracy analysis and reproducibility of first-generation prototype. Refract Corneal Surg 5:424–429PubMed Koch DD, Foulks GN, Moran CT, Wakil JS (1989) The Corneal EyeSys System: accuracy analysis and reproducibility of first-generation prototype. Refract Corneal Surg 5:424–429PubMed
20.
go back to reference Dave T, Ruston D, Fowler C (1998) Evaluation of the EyeSys model II computerized videokeratoscope. Part II: the repeatability and accuracy in measuring convex aspheric surfaces. Optom Vis Sci 75:656–662PubMedCrossRef Dave T, Ruston D, Fowler C (1998) Evaluation of the EyeSys model II computerized videokeratoscope. Part II: the repeatability and accuracy in measuring convex aspheric surfaces. Optom Vis Sci 75:656–662PubMedCrossRef
21.
go back to reference Swart TC (2010) Pentacam. In: Agarwal A, Agarwal A, Jacob S (eds) Dr Agarwal’s textbook on corneal topography: including Pentacam and anterior segment OCT. Jaypee Highlights Medical Publishers, New Delhi, pp 117–136 Swart TC (2010) Pentacam. In: Agarwal A, Agarwal A, Jacob S (eds) Dr Agarwal’s textbook on corneal topography: including Pentacam and anterior segment OCT. Jaypee Highlights Medical Publishers, New Delhi, pp 117–136
22.
go back to reference Sunderraj P (1992) Clinical comparison of automated and manual keratometry in pre-operative ocular biometry. Eye (Lond) 6:60–62CrossRef Sunderraj P (1992) Clinical comparison of automated and manual keratometry in pre-operative ocular biometry. Eye (Lond) 6:60–62CrossRef
23.
go back to reference Kim EC, Cho K, Hwang HS, Hwang KY, Kim MS (2013) Intraocular lens prediction accuracy after corneal refractive surgery using K values from 3 devices. J Cataract Refract Surg 39:1640–1646PubMedCrossRef Kim EC, Cho K, Hwang HS, Hwang KY, Kim MS (2013) Intraocular lens prediction accuracy after corneal refractive surgery using K values from 3 devices. J Cataract Refract Surg 39:1640–1646PubMedCrossRef
24.
go back to reference Thebpatiphat N, Hammersmith KM, Rapuano CJ, Ayres BD, Cohen EJ (2007) Cataract surgery in keratoconus. Eye Contact Lens 33:244–246PubMedCrossRef Thebpatiphat N, Hammersmith KM, Rapuano CJ, Ayres BD, Cohen EJ (2007) Cataract surgery in keratoconus. Eye Contact Lens 33:244–246PubMedCrossRef
25.
go back to reference Shirayama M, Wang L, Weikert MP, Koch DD (2009) Comparison of corneal powers obtained from 4 different devices. Am J Ophthalmol 148(528–35):e1PubMed Shirayama M, Wang L, Weikert MP, Koch DD (2009) Comparison of corneal powers obtained from 4 different devices. Am J Ophthalmol 148(528–35):e1PubMed
26.
go back to reference Pardhan S, Douthwaite WA (1998) Comparison of videokeratoscope and autokeratometer measurements on ellipsoid surfaces and human corneas. J Refract Surg 14:414–419 Pardhan S, Douthwaite WA (1998) Comparison of videokeratoscope and autokeratometer measurements on ellipsoid surfaces and human corneas. J Refract Surg 14:414–419
27.
go back to reference Kawamorita T, Nakayama N, Uozato H (2009) Repeatability and reproducibility of corneal curvature measurements using the Pentacam and Keratron topography systems. J Refract Surg 25:539–544PubMedCrossRef Kawamorita T, Nakayama N, Uozato H (2009) Repeatability and reproducibility of corneal curvature measurements using the Pentacam and Keratron topography systems. J Refract Surg 25:539–544PubMedCrossRef
28.
go back to reference McEwan JR, Massengill RK, Friedel SO (1990) The effect of keratometer and axial length measurements on primary implant power calculations. J Cataract Refract Surg 16:61–70PubMedCrossRef McEwan JR, Massengill RK, Friedel SO (1990) The effect of keratometer and axial length measurements on primary implant power calculations. J Cataract Refract Surg 16:61–70PubMedCrossRef
29.
30.
go back to reference Giraldez MJ, Yebra-Pimentel E, Parafita MA, Escandon S, Cervino A, Perez MV (2000) Comparison of Keratometric Values of Healthy Eyes Measured by Javal Keratometer, Nidek Autokeratometer, and Corneal Analysis System (EyeSys). Int Contact Lens Clin 27:33–40CrossRef Giraldez MJ, Yebra-Pimentel E, Parafita MA, Escandon S, Cervino A, Perez MV (2000) Comparison of Keratometric Values of Healthy Eyes Measured by Javal Keratometer, Nidek Autokeratometer, and Corneal Analysis System (EyeSys). Int Contact Lens Clin 27:33–40CrossRef
31.
go back to reference Davies LN, Mallen EA, Wolffsohn JS, Gilmartin B (2003) Clinical evaluation of the Shin-Nippon NVision-K 5001/Grand Seiko WR-5100 K autorefractor. Optom Vis Sci 80:320–324PubMedCrossRef Davies LN, Mallen EA, Wolffsohn JS, Gilmartin B (2003) Clinical evaluation of the Shin-Nippon NVision-K 5001/Grand Seiko WR-5100 K autorefractor. Optom Vis Sci 80:320–324PubMedCrossRef
32.
go back to reference Sheppard AL, Davies LN (2010) Clinical evaluation of the Grand Seiko Auto Ref/Keratometer WAM-5500. Ophthalmic Physiol Opt 30:143–151PubMedCrossRef Sheppard AL, Davies LN (2010) Clinical evaluation of the Grand Seiko Auto Ref/Keratometer WAM-5500. Ophthalmic Physiol Opt 30:143–151PubMedCrossRef
33.
go back to reference Nemeth J, Fekete O, Pesztenlehrer N (2003) Optical and ultrasound measurement of axial length and anterior chamber depth for intraocular lens power calculation. J Cataract Refract Surg 29:85–88PubMedCrossRef Nemeth J, Fekete O, Pesztenlehrer N (2003) Optical and ultrasound measurement of axial length and anterior chamber depth for intraocular lens power calculation. J Cataract Refract Surg 29:85–88PubMedCrossRef
34.
go back to reference McAlinden C, Khadka J, Pesudovs K (2011) A comprehensive evaluation of the precision (repeatability and reproducibility) of the Oculus Pentacam HR. Invest Ophthalmol Vis Sci 52:7731–7737PubMedCrossRef McAlinden C, Khadka J, Pesudovs K (2011) A comprehensive evaluation of the precision (repeatability and reproducibility) of the Oculus Pentacam HR. Invest Ophthalmol Vis Sci 52:7731–7737PubMedCrossRef
35.
go back to reference Chang M, Kang S, Kim HM (2012) Which Keratometer is Most Reliable for Correcting Astigmatism with Toric Intraocular Lenses? Korean J Ophthalmol 26:10–14PubMedCentralPubMedCrossRef Chang M, Kang S, Kim HM (2012) Which Keratometer is Most Reliable for Correcting Astigmatism with Toric Intraocular Lenses? Korean J Ophthalmol 26:10–14PubMedCentralPubMedCrossRef
36.
go back to reference Whang WJ, Byun YS, Joo CK (2012) Comparison of refractive outcomes using five devices for the assessment of preoperative corneal power. Clin Experiment Ophthalmol 40:425–432PubMedCrossRef Whang WJ, Byun YS, Joo CK (2012) Comparison of refractive outcomes using five devices for the assessment of preoperative corneal power. Clin Experiment Ophthalmol 40:425–432PubMedCrossRef
37.
go back to reference Holladay JT, Hill WE, Steinmueller A (2009) Corneal power measurements using scheimpflug imaging in eyes with prior corneal refractive surgery. J Refract Surg 25:862–868PubMedCrossRef Holladay JT, Hill WE, Steinmueller A (2009) Corneal power measurements using scheimpflug imaging in eyes with prior corneal refractive surgery. J Refract Surg 25:862–868PubMedCrossRef
38.
go back to reference Varssano D, Rapuano CJ, Luchs JI (1997) Comparison of keratometric values of healthy and diseased eyes measured by Javal keratometer, EyeSys, and PAR. J Cataract Refract Surg 23:419–422PubMedCrossRef Varssano D, Rapuano CJ, Luchs JI (1997) Comparison of keratometric values of healthy and diseased eyes measured by Javal keratometer, EyeSys, and PAR. J Cataract Refract Surg 23:419–422PubMedCrossRef
39.
go back to reference Moura RC, Bowyer BL, Stevens SX, Rowsey JJ (1998) Comparison of three computerized videokeratoscopy systems with keratometry. Cornea 17:522–528PubMedCrossRef Moura RC, Bowyer BL, Stevens SX, Rowsey JJ (1998) Comparison of three computerized videokeratoscopy systems with keratometry. Cornea 17:522–528PubMedCrossRef
40.
go back to reference Read SA, Collins MJ, Iskander DR, Davis BA (2009) Corneal topography with Scheimpflug imaging and videokeratography: comparative study of normal eyes. J Cataract Refract Surg 35:1072–1081PubMedCrossRef Read SA, Collins MJ, Iskander DR, Davis BA (2009) Corneal topography with Scheimpflug imaging and videokeratography: comparative study of normal eyes. J Cataract Refract Surg 35:1072–1081PubMedCrossRef
41.
go back to reference Elbaz U, Barkana Y, Gerber Y, Avni I, Zadok D (2007) Comparison of different techniques of anterior chamber depth and keratometric measurements. Am J Ophthalmol 143:48–53 Elbaz U, Barkana Y, Gerber Y, Avni I, Zadok D (2007) Comparison of different techniques of anterior chamber depth and keratometric measurements. Am J Ophthalmol 143:48–53
42.
go back to reference Huynh SC, Mai TQ, Kifley A, Wang JJ, Rose KA, Mitchell P (2006) An evaluation of keratometry in 6-year-old children. Cornea 25:383–387PubMedCrossRef Huynh SC, Mai TQ, Kifley A, Wang JJ, Rose KA, Mitchell P (2006) An evaluation of keratometry in 6-year-old children. Cornea 25:383–387PubMedCrossRef
Metadata
Title
Keratometry with five different techniques: a study of device repeatability and inter-device agreement
Authors
Shiva Mehravaran
Soheila Asgari
Sara Bigdeli
Ashkan Shahnazi
Hassan Hashemi
Publication date
01-08-2014
Publisher
Springer Netherlands
Published in
International Ophthalmology / Issue 4/2014
Print ISSN: 0165-5701
Electronic ISSN: 1573-2630
DOI
https://doi.org/10.1007/s10792-013-9895-3

Other articles of this Issue 4/2014

International Ophthalmology 4/2014 Go to the issue