Skip to main content
Top
Published in: Digestive Diseases and Sciences 1/2017

01-01-2017 | Editorial

Gastrointestinal Bleeding During Index Hospitalization for Mechanical Circulatory Support Devices Implantation: Is the Squeeze Worth the Ooze?

Authors: Darius A. Jahann, Vanessa M. Shami

Published in: Digestive Diseases and Sciences | Issue 1/2017

Login to get access

Excerpt

Mechanical circulatory support devices, which include left ventricular assist devices (LVADs) and intra-aortic balloon pumps (IABPs), have been used increasingly over the past decade. LVADs sustain patients with severe left ventricular dysfunction who are being evaluated for or await cardiac transplantation, as a destination therapy, or a bridge to recovery of cardiac function [1]. Their increasing popularity in the past decade is partially attributable to remarkable advances in LVAD technology. First-generation devices, which functioned by a mechanism of pulsatile blood flow, were beset by poor durability and high rates of infection and thrombosis, encouraging the development of smaller, continuous-flow LVADs which involve rotary-pump technology to provide blood flow with reduced pulsatility. These latter devices have improved the probability of survival free from stroke and device failure at 2 years compared with the first-generation device [2]. Nevertheless, the increasing use of this technology has been accompanied by a notable rate of gastrointestinal bleeding (GIB) with a recent meta-analysis estimating the pooled prevalence of GIB in LVAD patients to be an astounding 23% [3]. …
Literature
1.
go back to reference Ammirati E, Oliva F, Cannata A, et al. Current indications for heart transplantation and left ventricular assist device: a practical point of view. Eur J Intern Med. 2014;25:422–429.CrossRefPubMed Ammirati E, Oliva F, Cannata A, et al. Current indications for heart transplantation and left ventricular assist device: a practical point of view. Eur J Intern Med. 2014;25:422–429.CrossRefPubMed
2.
go back to reference Slaughter MS, Rogers JG, Milano CA, et al. Advanced heart failure treated with continuous-flow left ventricular assist device. N Engl J Med. 2009;3:2241–2251.CrossRef Slaughter MS, Rogers JG, Milano CA, et al. Advanced heart failure treated with continuous-flow left ventricular assist device. N Engl J Med. 2009;3:2241–2251.CrossRef
3.
go back to reference Draper KV, Huang RJ, Gerson LB. GI bleeding in patients with continuous-flow left ventricular assist devices: a systematic review and meta-analysis. Gastrointest Endosc. 2014;80:435–446.e1.CrossRefPubMed Draper KV, Huang RJ, Gerson LB. GI bleeding in patients with continuous-flow left ventricular assist devices: a systematic review and meta-analysis. Gastrointest Endosc. 2014;80:435–446.e1.CrossRefPubMed
4.
go back to reference Boudoulas KD, Pederzolli A, Saini U, et al. Comparison of Impella and intra-aortic balloon pump in high-risk percutaneous coronary intervention: vascular complications and incidence of bleeding. Acute Card Care. 2012;14:120–124.CrossRefPubMed Boudoulas KD, Pederzolli A, Saini U, et al. Comparison of Impella and intra-aortic balloon pump in high-risk percutaneous coronary intervention: vascular complications and incidence of bleeding. Acute Card Care. 2012;14:120–124.CrossRefPubMed
5.
go back to reference Abbas A, Mahmoud A, Ahmed M, Aranda J, Klodell CT, Draganov PV. Gastrointestinal bleeding during the index hospitalization for mechanical circulatory support devices implantation, a nationwide perspective. Dig Dis Sci. 2016. doi:10.1007/s10620-016-4271-6.PubMed Abbas A, Mahmoud A, Ahmed M, Aranda J, Klodell CT, Draganov PV. Gastrointestinal bleeding during the index hospitalization for mechanical circulatory support devices implantation, a nationwide perspective. Dig Dis Sci. 2016. doi:10.​1007/​s10620-016-4271-6.PubMed
6.
go back to reference Cooper GS, Chak A, Lloyd LE, Yurchick PJ, Harper DL, Rosenthal GE. The accuracy of diagnosis and procedural codes for patients with upper GI hemorrhage. Gastrointest Endosc. 2000;1:423–426.CrossRef Cooper GS, Chak A, Lloyd LE, Yurchick PJ, Harper DL, Rosenthal GE. The accuracy of diagnosis and procedural codes for patients with upper GI hemorrhage. Gastrointest Endosc. 2000;1:423–426.CrossRef
7.
go back to reference Kushnir VM, Sharma S, Ewald GA, Seccombe J, Novak E, Wang I-W, et al. Evaluation of GI bleeding after implantation of left ventricular assist device. Gastrointest Endosc. 2012;75:973–979.CrossRefPubMed Kushnir VM, Sharma S, Ewald GA, Seccombe J, Novak E, Wang I-W, et al. Evaluation of GI bleeding after implantation of left ventricular assist device. Gastrointest Endosc. 2012;75:973–979.CrossRefPubMed
8.
go back to reference Uriel N, Pak S-W, Jorde UP, et al. Acquired von Willebrand syndrome after continuous-flow mechanical device support contributes to a high prevalence of bleeding during long-term support and at the time of transplantation. J Am Coll Cardiol. 2010;5:1207–1213.CrossRef Uriel N, Pak S-W, Jorde UP, et al. Acquired von Willebrand syndrome after continuous-flow mechanical device support contributes to a high prevalence of bleeding during long-term support and at the time of transplantation. J Am Coll Cardiol. 2010;5:1207–1213.CrossRef
Metadata
Title
Gastrointestinal Bleeding During Index Hospitalization for Mechanical Circulatory Support Devices Implantation: Is the Squeeze Worth the Ooze?
Authors
Darius A. Jahann
Vanessa M. Shami
Publication date
01-01-2017
Publisher
Springer US
Published in
Digestive Diseases and Sciences / Issue 1/2017
Print ISSN: 0163-2116
Electronic ISSN: 1573-2568
DOI
https://doi.org/10.1007/s10620-016-4386-9

Other articles of this Issue 1/2017

Digestive Diseases and Sciences 1/2017 Go to the issue