Skip to main content
Top
Published in: The International Journal of Cardiovascular Imaging 8/2019

01-08-2019 | Pulmonary Valve Replacement | Original Paper

Role of cardiovascular magnetic resonance end-systolic 3D-SSFP sequence in repaired tetralogy of Fallot patients eligible for transcatheter pulmonary valve implantation

Authors: Benedetta Leonardi, Aurelio Secinaro, Marco Alfonso Perrone, Davide Curione, Carmela Napolitano, Maria Giulia Gagliardi

Published in: The International Journal of Cardiovascular Imaging | Issue 8/2019

Login to get access

Abstract

To evaluate the usefulness of cardiovascular magnetic resonance (CMR) 3D steady state free precession (SSFP) sequence acquired at end-systole (ES) in repaired Tetralogy of Fallot (rToF) patients eligible for percutaneous pulmonary valve implantation (PPVI). Between 2012 and 2018, 78 rToF patients were selected for pulmonary valve replacement (PVR) according to CMR criteria. CMR protocol included 3D-SSFP sequence used to assess the right ventricle outflow tract (RVOT) diameters at three levels (pulmonary valve remnant, mid-portion, bifurcation) in mid-diastole (MD) or ES, RVOT length and coronary artery anatomy. In 20 rToF patients without indications for PVR (controls), 3D SSFP sequence was acquired at both cardiac phases (MD and ES) to evaluate RVOT dimension throughout the cardiac cycle. Invasive balloon sizing was recorded in patients undergoing PPVI. The 3D-SSFP sequence was performed in MD on 39 patients and in ES on other 39, of whom 26 patients met the criteria for PPVI. The latter was unsuccessful in ten patients (38%), mainly due (80% of cases) to significant size discrepancy at PV remnant and bifurcation levels (p = 0.019 and 0.037 respectively) between the measurements by 3D-SSFP in MD and those by the balloon size in systole. Significant RVOT size difference between MD and ES was present at mid-portion and bifurcation levels in the PVR candidate group, and at all three-levels in the control group (all p < 0.001). ES 3D-SSFP sequence is able to quantify RVOT dilation in rToF patients at its maximum expansion, thus improving selection of PPVI candidates.
Literature
1.
go back to reference Martinez RM, Ringewald JM, Fontanet HL, Quintessenza JA, Jacobs JP (2013) Management of adults with Tetralogy of Fallot. Cardiol Young 23:921–932CrossRefPubMed Martinez RM, Ringewald JM, Fontanet HL, Quintessenza JA, Jacobs JP (2013) Management of adults with Tetralogy of Fallot. Cardiol Young 23:921–932CrossRefPubMed
2.
go back to reference Burchill LJ, Wald RM, Harris L, Colman JM, Silversides CK (2011) Pulmonary valve replacement in adults with repaired tetralogy of Fallot. Semin Thorac Cardiovasc Surg Pediatr Card Surg Annu 14:92–97CrossRefPubMed Burchill LJ, Wald RM, Harris L, Colman JM, Silversides CK (2011) Pulmonary valve replacement in adults with repaired tetralogy of Fallot. Semin Thorac Cardiovasc Surg Pediatr Card Surg Annu 14:92–97CrossRefPubMed
3.
go back to reference Ferraz Cavalcanti PE, Sa MP, Santos CA, Esmeraldo IM, de Escobar RR, de Menezes AM, de Azevedo OM, Jr, de Vasconcelos Silva FP, Lins RF, de Lima R C (2013) Pulmonary valve replacement after operative repair of tetralogy of Fallot: meta-analysis and meta-regression of 3,118 patients from 48 studies. J Am Coll Cardiol 62:2227–2243CrossRefPubMed Ferraz Cavalcanti PE, Sa MP, Santos CA, Esmeraldo IM, de Escobar RR, de Menezes AM, de Azevedo OM, Jr, de Vasconcelos Silva FP, Lins RF, de Lima R C (2013) Pulmonary valve replacement after operative repair of tetralogy of Fallot: meta-analysis and meta-regression of 3,118 patients from 48 studies. J Am Coll Cardiol 62:2227–2243CrossRefPubMed
4.
go back to reference Frigiola A, Nordmeyer J, Bonhoeffer P (2009) Percutaneous pulmonary valve replacement. Coron Artery Dis 20:189–191CrossRefPubMed Frigiola A, Nordmeyer J, Bonhoeffer P (2009) Percutaneous pulmonary valve replacement. Coron Artery Dis 20:189–191CrossRefPubMed
5.
go back to reference Hawkins JA, Sower CT, Lambert LM, Kouretas PC, Burch PT, Kaza AK, Puchalski MD, Yetman AT (2009) Stentless porcine valves in the right ventricular outflow tract: improved durability? Eur J Cardiothorac Surg 35:600–4; discussion 604–5CrossRefPubMed Hawkins JA, Sower CT, Lambert LM, Kouretas PC, Burch PT, Kaza AK, Puchalski MD, Yetman AT (2009) Stentless porcine valves in the right ventricular outflow tract: improved durability? Eur J Cardiothorac Surg 35:600–4; discussion 604–5CrossRefPubMed
6.
7.
go back to reference Demkow M, Ruzyllo W, Biernacka EK, Kalińczuk Ł, Spiewak M, Kowalski M, Sitkowska E, Kuśmierczyk M, Różanski J, Banaś S, Chmielak Z, Hoffman P (2014) Percutaneous Edwards SAPIEN valve implantation for significant pulmonary regurgitation after previous surgical repair with a right ventricular outflow patch. Catheter Cardiovasc Interv 83:474–481CrossRefPubMed Demkow M, Ruzyllo W, Biernacka EK, Kalińczuk Ł, Spiewak M, Kowalski M, Sitkowska E, Kuśmierczyk M, Różanski J, Banaś S, Chmielak Z, Hoffman P (2014) Percutaneous Edwards SAPIEN valve implantation for significant pulmonary regurgitation after previous surgical repair with a right ventricular outflow patch. Catheter Cardiovasc Interv 83:474–481CrossRefPubMed
8.
go back to reference Hascoet S, Acar P, Boudjemline Y (2014) Transcatheter pulmonary valvulation: current indications and available devices. Arch Cardiovasc Dis 107:625–634CrossRefPubMed Hascoet S, Acar P, Boudjemline Y (2014) Transcatheter pulmonary valvulation: current indications and available devices. Arch Cardiovasc Dis 107:625–634CrossRefPubMed
9.
go back to reference Boshoff DE, Cools BL, Heying R, Troost E, Kefer J, Budts W, Gewillig M (2013) Off-label use of percutaneous pulmonary valved stents in the right ventricular outflow tract: time to rewrite the label? Catheter Cardiovasc Interv 81:987–995CrossRefPubMed Boshoff DE, Cools BL, Heying R, Troost E, Kefer J, Budts W, Gewillig M (2013) Off-label use of percutaneous pulmonary valved stents in the right ventricular outflow tract: time to rewrite the label? Catheter Cardiovasc Interv 81:987–995CrossRefPubMed
10.
go back to reference Haas NA, Moysich A, Neudorf U, Mortezaeian H, Abdel-Wahab M, Schneider H, De Wolf D, Petit J, Narayanswami S, Laser KT, Sandica E (2013) Percutaneous implantation of the Edwards SAPIEN pulmonic valve: initial results in the first 22 patients. Clin Res Cardiol 102:119–128CrossRefPubMed Haas NA, Moysich A, Neudorf U, Mortezaeian H, Abdel-Wahab M, Schneider H, De Wolf D, Petit J, Narayanswami S, Laser KT, Sandica E (2013) Percutaneous implantation of the Edwards SAPIEN pulmonic valve: initial results in the first 22 patients. Clin Res Cardiol 102:119–128CrossRefPubMed
11.
go back to reference Chung R, Taylor AM (2014) Imaging for preintervention planning: transcatheter pulmonary valve therapy. Circ Cardiovasc Imaging 7(1):182–189CrossRefPubMed Chung R, Taylor AM (2014) Imaging for preintervention planning: transcatheter pulmonary valve therapy. Circ Cardiovasc Imaging 7(1):182–189CrossRefPubMed
12.
go back to reference Schievano S, Coats L, Migliavacca F, Norman W, Frigiola A, Deanfield J, Bonhoeffer P, Taylor AM (2007) Variations in right ventricular outflow tract morphology following repair of congenital heart disease: implications for percutaneous pulmonary valve implantation. J Cardiovasc Magn Reson 9(4):687–695CrossRefPubMed Schievano S, Coats L, Migliavacca F, Norman W, Frigiola A, Deanfield J, Bonhoeffer P, Taylor AM (2007) Variations in right ventricular outflow tract morphology following repair of congenital heart disease: implications for percutaneous pulmonary valve implantation. J Cardiovasc Magn Reson 9(4):687–695CrossRefPubMed
14.
go back to reference Geva T (2014) Is MRI the preferred method for evaluating right ventricular size and function in patients with congenital heart disease?: MRI is the preferred method for evaluating right ventricular size and function in patients with congenital heart disease. Circ Cardiovasc Imaging 7:190–197CrossRefPubMedCentralPubMed Geva T (2014) Is MRI the preferred method for evaluating right ventricular size and function in patients with congenital heart disease?: MRI is the preferred method for evaluating right ventricular size and function in patients with congenital heart disease. Circ Cardiovasc Imaging 7:190–197CrossRefPubMedCentralPubMed
15.
16.
go back to reference Geva T, Greil GF, Marshall AC, Landzberg M, Powell AJ (2002) Gadolinium-enhanced 3-dimensional magnetic resonance angiography of pulmonary blood supply in patients with complex pulmonary stenosis or atresia: Comparison with x-ray angiography. Circulation 106:473–478CrossRefPubMed Geva T, Greil GF, Marshall AC, Landzberg M, Powell AJ (2002) Gadolinium-enhanced 3-dimensional magnetic resonance angiography of pulmonary blood supply in patients with complex pulmonary stenosis or atresia: Comparison with x-ray angiography. Circulation 106:473–478CrossRefPubMed
17.
go back to reference Groves EM, Bireley W, Dill K, Carroll TJ, Carr JC (2007) Quantitative analysys of ECG-gated high-resolution contrast-enhanced MR angiography of the thoracic aorta. AJR 188:522–528CrossRefPubMed Groves EM, Bireley W, Dill K, Carroll TJ, Carr JC (2007) Quantitative analysys of ECG-gated high-resolution contrast-enhanced MR angiography of the thoracic aorta. AJR 188:522–528CrossRefPubMed
18.
go back to reference Chang D, Kong X, Zhou X, Li S, Wang H (2013) Unenhanced steady state free precession versus traditional MR imaging for congenital heart disease. Eur J Radiol 82:1743–1748CrossRefPubMed Chang D, Kong X, Zhou X, Li S, Wang H (2013) Unenhanced steady state free precession versus traditional MR imaging for congenital heart disease. Eur J Radiol 82:1743–1748CrossRefPubMed
19.
go back to reference Francois CJ, Tuite D, Deshpande V, Jerecic R, Weale P, Carr JC (2008) Unenhanced MR angiography of the thoracic aorta: initial clinical evaluation. AJR Am J Roentgenol 190:902–906CrossRefPubMed Francois CJ, Tuite D, Deshpande V, Jerecic R, Weale P, Carr JC (2008) Unenhanced MR angiography of the thoracic aorta: initial clinical evaluation. AJR Am J Roentgenol 190:902–906CrossRefPubMed
20.
go back to reference Hussain T, Lossnitzer D, Bellsham-Revell H, Valverde I, Beerbaum P, Razavi R, Bell AJ, Schaeffter T, Botnar RM, Uribe SA, Greil GF (2012) Three-dimensional dual-phase whole-heart MR imaging: clinical implications for congenital heart disease. Radiology 263:547–554CrossRefPubMed Hussain T, Lossnitzer D, Bellsham-Revell H, Valverde I, Beerbaum P, Razavi R, Bell AJ, Schaeffter T, Botnar RM, Uribe SA, Greil GF (2012) Three-dimensional dual-phase whole-heart MR imaging: clinical implications for congenital heart disease. Radiology 263:547–554CrossRefPubMed
21.
go back to reference Schievano S, Capelli C, Young C, Lurz P, Nordmeyer J, Owens C, Bonhoeffer P, Taylor AM (2011) Four-dimensional computed tomography: a method of assessing right ventricular outflow tract and pulmonary artery deformations throughout the cardiac cycle. Eur Radiol 21(1):36–45CrossRefPubMed Schievano S, Capelli C, Young C, Lurz P, Nordmeyer J, Owens C, Bonhoeffer P, Taylor AM (2011) Four-dimensional computed tomography: a method of assessing right ventricular outflow tract and pulmonary artery deformations throughout the cardiac cycle. Eur Radiol 21(1):36–45CrossRefPubMed
22.
go back to reference Schievano S, Taylor AM, Capelli C, Coats L, Walker F, Lurz P, Nordmeyer J, Wright S, Khambadkone S, Tsang V, Carminati M, Bonhoeffer P (2010) First-in-man implantation of a novel percutaneous valve: a new approach to medical device development. EuroIntervention 5(6):745–750CrossRefPubMed Schievano S, Taylor AM, Capelli C, Coats L, Walker F, Lurz P, Nordmeyer J, Wright S, Khambadkone S, Tsang V, Carminati M, Bonhoeffer P (2010) First-in-man implantation of a novel percutaneous valve: a new approach to medical device development. EuroIntervention 5(6):745–750CrossRefPubMed
23.
go back to reference Schievano S, Migliavacca F, Coats L, Khambadkone S, Carminati M, Wilson N, Deanfield JE, Bonhoeffer P, Taylor AM (2007) Percutaneous pulmonary valve implantation based on rapid prototyping of right ventricular outflow tract and pulmonary trunk from MR data. Radiology 242(2):490–497CrossRefPubMed Schievano S, Migliavacca F, Coats L, Khambadkone S, Carminati M, Wilson N, Deanfield JE, Bonhoeffer P, Taylor AM (2007) Percutaneous pulmonary valve implantation based on rapid prototyping of right ventricular outflow tract and pulmonary trunk from MR data. Radiology 242(2):490–497CrossRefPubMed
25.
go back to reference Thomsen HS (2016) Nephrogenic systemic fibrosis: a serious adverse reaction to gadolinium—1997-2006-2016. Part 1. Acta Radiol 57(5):515–520CrossRefPubMed Thomsen HS (2016) Nephrogenic systemic fibrosis: a serious adverse reaction to gadolinium—1997-2006-2016. Part 1. Acta Radiol 57(5):515–520CrossRefPubMed
26.
go back to reference Thomsen HS (2016) Nephrogenic systemic fibrosis: a serious adverse reaction to gadolinium—1997-2006-2016. Part 2. Acta Radiol 57(6):643–648CrossRefPubMed Thomsen HS (2016) Nephrogenic systemic fibrosis: a serious adverse reaction to gadolinium—1997-2006-2016. Part 2. Acta Radiol 57(6):643–648CrossRefPubMed
Metadata
Title
Role of cardiovascular magnetic resonance end-systolic 3D-SSFP sequence in repaired tetralogy of Fallot patients eligible for transcatheter pulmonary valve implantation
Authors
Benedetta Leonardi
Aurelio Secinaro
Marco Alfonso Perrone
Davide Curione
Carmela Napolitano
Maria Giulia Gagliardi
Publication date
01-08-2019
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue 8/2019
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-019-01630-9

Other articles of this Issue 8/2019

The International Journal of Cardiovascular Imaging 8/2019 Go to the issue