Skip to main content
Top
Published in: The International Journal of Cardiovascular Imaging 4/2019

Open Access 01-04-2019 | Magnetic Resonance Imaging | Original Paper

Bileaflet mechanical aortic valves do not alter ascending aortic wall shear stress

Authors: Emile S. Farag, Emilio L. Schade, Pim van Ooij, S. Matthijs Boekholdt, R. Nils Planken, Roland van Kimmenade, Aart J. Nederveen, Bas A. J. M. de Mol, Jolanda Kluin

Published in: The International Journal of Cardiovascular Imaging | Issue 4/2019

Login to get access

Abstract

Progressive ascending aortic dilatation has been observed after mechanical aortic valve replacement (mAVR), possibly due to altered blood flow and wall shear stress (WSS) patterns induced by their bileaflet design. We examined the effect of mAVR on WSS in the ascending aorta using time-resolved 4D flow MRI. Fifteen patients with mechanical aortic valve prostheses, 10 patients with bicuspid aortic valve disease and 10 healthy individuals underwent thoracic 4D flow MRI. Peak systolic hemodynamic parameters (velocity and WSS) and vessel diameters were assessed in the ascending aorta. In addition, three-dimensional per-voxel analysis was used to compare velocity and WSS between patient groups and healthy controls. Peak aortic diameters were significantly higher in mAVR and BAV patients compared to healthy controls (p = 0.011). Mean aortic diameters were comparable between mAVR and BAV patients. No differences in 4D flow MRI-derived mean blood flow velocity and peak WSS were found between the three groups. Compared to healthy controls, mean WSS was significantly lower in mAVR patients (p = 0.031). Per-voxel analysis revealed no increased WSS in the ascending aortic wall and significantly lower velocity and WSS values in mAVR patients compared to healthy controls. In contrast, regions of significantly increased outer lumen velocities and WSS in BAV patients compared to healthy controls were found. This study shows that there is no increased ascending aortic WSS after mAVR. Our results suggest that, in contrast to BAV patients, there is no indication for intensified follow-up of the ascending aorta after mAVR.
Literature
3.
go back to reference Yuan SM, Lavee J (2012) Progressive aortic dilation after aortic valve replacement. Surg Pract 16:137–141CrossRef Yuan SM, Lavee J (2012) Progressive aortic dilation after aortic valve replacement. Surg Pract 16:137–141CrossRef
7.
go back to reference Guzzardi DG, Barker AJ, Van Ooij P, Malaisrie SC, Puthumana JJ, Belke DD et al (2015) Valve-related hemodynamics mediate human bicuspid aortopathy: insights from wall shear stress mapping. J Am Coll Cardiol 66:892–900CrossRefPubMedPubMedCentral Guzzardi DG, Barker AJ, Van Ooij P, Malaisrie SC, Puthumana JJ, Belke DD et al (2015) Valve-related hemodynamics mediate human bicuspid aortopathy: insights from wall shear stress mapping. J Am Coll Cardiol 66:892–900CrossRefPubMedPubMedCentral
8.
go back to reference Van Ooij P, Garcia J, Potters WV, Malaisrie SC, Collins JD, Carr JC et al (2016) Age-related changes in aortic 3D blood flow velocities and wall shear stress: Implications for the identification of altered hemodynamics in patients with aortic valve disease. J Magn Reson Imaging 43:1239–1249CrossRefPubMed Van Ooij P, Garcia J, Potters WV, Malaisrie SC, Collins JD, Carr JC et al (2016) Age-related changes in aortic 3D blood flow velocities and wall shear stress: Implications for the identification of altered hemodynamics in patients with aortic valve disease. J Magn Reson Imaging 43:1239–1249CrossRefPubMed
13.
go back to reference Potters WV, Van Ooij P, Marquering H, VanBavel E, Nederveen AJ (2015) Volumetric arterial wall shear stress calculation based on cine phase contrast MRI. J Magn Reson Imaging 41:505–516CrossRefPubMed Potters WV, Van Ooij P, Marquering H, VanBavel E, Nederveen AJ (2015) Volumetric arterial wall shear stress calculation based on cine phase contrast MRI. J Magn Reson Imaging 41:505–516CrossRefPubMed
14.
go back to reference van Ooij P, Potters WV, Collins J, Carr M, Carr J, Malaisrie SC et al (2015) Characterization of abnormal wall shear stress using 4D flow MRI in human bicuspid aortopathy. Ann Biomed Eng 43:1385–1397CrossRefPubMed van Ooij P, Potters WV, Collins J, Carr M, Carr J, Malaisrie SC et al (2015) Characterization of abnormal wall shear stress using 4D flow MRI in human bicuspid aortopathy. Ann Biomed Eng 43:1385–1397CrossRefPubMed
17.
go back to reference Erbel R, Aboyans V, Boileau C, Bossone E, Di Bartolomeo R, Eggebrecht H et al (2014) 2014 ESC guidelines on the diagnosis and treatment of aortic diseases. Eur Heart J 35:2873–2926CrossRefPubMed Erbel R, Aboyans V, Boileau C, Bossone E, Di Bartolomeo R, Eggebrecht H et al (2014) 2014 ESC guidelines on the diagnosis and treatment of aortic diseases. Eur Heart J 35:2873–2926CrossRefPubMed
Metadata
Title
Bileaflet mechanical aortic valves do not alter ascending aortic wall shear stress
Authors
Emile S. Farag
Emilio L. Schade
Pim van Ooij
S. Matthijs Boekholdt
R. Nils Planken
Roland van Kimmenade
Aart J. Nederveen
Bas A. J. M. de Mol
Jolanda Kluin
Publication date
01-04-2019
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue 4/2019
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-018-1508-9

Other articles of this Issue 4/2019

The International Journal of Cardiovascular Imaging 4/2019 Go to the issue