Skip to main content
Top
Published in: The International Journal of Cardiovascular Imaging 4/2019

01-04-2019 | Original Paper

Automatic coronary blood flow computation: validation in quantitative flow ratio from coronary angiography

Authors: Yimin Zhang, Su Zhang, Jelmer Westra, Daixin Ding, Qiuyang Zhao, Junqing Yang, Zhongwei Sun, Jiayue Huang, Jun Pu, Bo Xu, Shengxian Tu

Published in: The International Journal of Cardiovascular Imaging | Issue 4/2019

Login to get access

Abstract

To assess a novel approach for automatic flow velocity computation in deriving quantitative flow ratio (QFR) from coronary angiography. QFR is a novel approach for assessment of functional significance of coronary artery stenosis without using pressure wire and induced hyperemia. Patient-specific coronary flow is estimated semi-automatically by frame count method, which is subjective and inconvenient in the workflow of QFR analysis. The vascular structures were automatically delineated from coronary angiogram. Subsequently, the centerline of the interrogated vessel was extracted from the delineated lumen on each image frame and the change in the length of centerline was used to compute the flow velocity, which provided patient-specific flow for computation of QFR (QFRauto). A parameter derived from the increase in centerline length was used to automatically quantify the stability of contrast flow. From the two angiographic image runs used for three-dimensional angiographic reconstruction, the one with better stability was used to compute QFRauto. QFRauto was assessed in all patients enrolled in the FAVOR II China study, and compared with the commercialized QFR computational method based on frame count (QFRcount), using pressure wire-based fractional flow reserve (FFR) as the reference standard. Out of 328 vessels with paired FFR data, QFRauto was successfully computed on 325 (99%) vessels with acceptable stability in filling of contrast flow. The flow velocity computed by the proposed approach had a weak to moderate correlation with the frame count method (r = 0.37, p < 0.001), with mean differences of − 0.02 ± 0.07 m/s (p < 0.001). QFRauto had good correlation (r = 0.96, p < 0.001) and agreement (mean difference: − 0.01 ± 0.04, p < 0.001) with QFRcount. Good correlation (r = 0.83, p < 0.001) and agreement (mean difference: 0.01 ± 0.06, p = 0.016) were also observed between QFRauto and FFR. Using FFR ≤ 0.80 to define functional significance of coronary stenosis, the overall diagnostic accuracy for QFRauto was 93.2% (95% CI 90.5–96.0%). The area under the receiver-operating characteristic curve did not differ significantly between QFRcount and QFRauto (difference: 0.00; 95% CI − 0.01 to 0.01; p = 0.529). Sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio for QFRauto were 92.4% (95% CI 86.0–96.5%), 93.7% (95% CI 89.5–96.6%), 14.7 (95% CI 8.7–25.0), and 0.1 (95% CI 0.0–0.2), respectively. Automatic computation of patient-specific coronary flow velocity based on coronary angiography is feasible. Assessment of QFR based on this novel approach had good diagnostic accuracy in determining the functional significance of coronary stenosis.
Literature
1.
go back to reference De Bruyne B, Pijls NHJ, Kalesan B et al (2012) Fractional flow reserve–guided PCI versus medical therapy in stable coronary disease. N Engl J Med 367(11):991–1001CrossRefPubMed De Bruyne B, Pijls NHJ, Kalesan B et al (2012) Fractional flow reserve–guided PCI versus medical therapy in stable coronary disease. N Engl J Med 367(11):991–1001CrossRefPubMed
2.
go back to reference Tonino PAL, De Bruyne B, Pijls NHJ et al (2009) Fractional flow reserve versus angiography for guiding percutaneous coronary intervention. N Engl J Med 360(3):213–224CrossRefPubMed Tonino PAL, De Bruyne B, Pijls NHJ et al (2009) Fractional flow reserve versus angiography for guiding percutaneous coronary intervention. N Engl J Med 360(3):213–224CrossRefPubMed
3.
go back to reference Johnson NP, Tóth GG, Lai D et al (2014) Prognostic value of fractional flow reserve: linking physiologic severity to clinical outcomes. J Am Coll Cardiol 64(16):1641–1654CrossRefPubMed Johnson NP, Tóth GG, Lai D et al (2014) Prognostic value of fractional flow reserve: linking physiologic severity to clinical outcomes. J Am Coll Cardiol 64(16):1641–1654CrossRefPubMed
4.
go back to reference Berry C, Corcoran D, Hennigan B et al (2015) Fractional flow reserve-guided management in stable coronary disease and acute myocardial infarction: recent developments. Eur Heart J 36(45):3155–3164CrossRefPubMedPubMedCentral Berry C, Corcoran D, Hennigan B et al (2015) Fractional flow reserve-guided management in stable coronary disease and acute myocardial infarction: recent developments. Eur Heart J 36(45):3155–3164CrossRefPubMedPubMedCentral
5.
go back to reference Fearon WF (2014) Percutaneous coronary intervention should be guided by fractional flow reserve measurement response to Fearon. Circulation 129(18):1860–1870CrossRefPubMedPubMedCentral Fearon WF (2014) Percutaneous coronary intervention should be guided by fractional flow reserve measurement response to Fearon. Circulation 129(18):1860–1870CrossRefPubMedPubMedCentral
6.
go back to reference Tu S, Westra J, Yang J et al (2016) Diagnostic accuracy of fast computational approaches to derive fractional flow reserve from diagnostic coronary angiography: the international multicenter FAVOR pilot study. JACC Cardiovasc Interv 9(19):2024–2035CrossRefPubMed Tu S, Westra J, Yang J et al (2016) Diagnostic accuracy of fast computational approaches to derive fractional flow reserve from diagnostic coronary angiography: the international multicenter FAVOR pilot study. JACC Cardiovasc Interv 9(19):2024–2035CrossRefPubMed
7.
go back to reference Tu S, Barbato E, Köszegi Z et al (2014) Fractional flow reserve calculation from 3-dimensional quantitative coronary angiography and TIMI frame count: a fast computer model to quantify the functional significance of moderately obstructed coronary arteries. JACC Cardiovasc Interv 7(7):768CrossRefPubMed Tu S, Barbato E, Köszegi Z et al (2014) Fractional flow reserve calculation from 3-dimensional quantitative coronary angiography and TIMI frame count: a fast computer model to quantify the functional significance of moderately obstructed coronary arteries. JACC Cardiovasc Interv 7(7):768CrossRefPubMed
8.
go back to reference Xu B, Tu S, Qiao S et al (2017) Diagnostic accuracy of angiography-based quantitative flow ratio measurements for online assessment of coronary stenosis. J Am Coll Cardiol 70(25):3077–3087CrossRefPubMed Xu B, Tu S, Qiao S et al (2017) Diagnostic accuracy of angiography-based quantitative flow ratio measurements for online assessment of coronary stenosis. J Am Coll Cardiol 70(25):3077–3087CrossRefPubMed
9.
go back to reference Westra J, Tu S, Winther S et al (2018) Evaluation of coronary artery stenosis by quantitative flow ratio during invasive coronary angiography: the WIFI II study (wire-free functional imaging II). Circ Cardiovasc Imaging 11(3):e007107CrossRefPubMedPubMedCentral Westra J, Tu S, Winther S et al (2018) Evaluation of coronary artery stenosis by quantitative flow ratio during invasive coronary angiography: the WIFI II study (wire-free functional imaging II). Circ Cardiovasc Imaging 11(3):e007107CrossRefPubMedPubMedCentral
10.
go back to reference Westra J, Andersen BK, Campo G et al (2018) Diagnostic performance of in-procedure angiography-derived quantitative flow reserve compared to pressure-derived fractional flow reserve: the FAVOR II Europe-Japan Study. J Am Heart Assoc Cardiovas Cerebrovasc Dis 7(14):e009603 Westra J, Andersen BK, Campo G et al (2018) Diagnostic performance of in-procedure angiography-derived quantitative flow reserve compared to pressure-derived fractional flow reserve: the FAVOR II Europe-Japan Study. J Am Heart Assoc Cardiovas Cerebrovasc Dis 7(14):e009603
11.
go back to reference Perona P, Malik J (2002) Scale-space and edge detection using anisotropic diffusion. IEEE Trans Pattern Anal Mach Intell 12(7):629–639CrossRef Perona P, Malik J (2002) Scale-space and edge detection using anisotropic diffusion. IEEE Trans Pattern Anal Mach Intell 12(7):629–639CrossRef
12.
go back to reference Jin Y, Fayad LM, Laine AF (2001) Contrast enhancement by multiscale adaptive histogram equalization. In: International symposium on optical science and technology. International society for optics and photonics Jin Y, Fayad LM, Laine AF (2001) Contrast enhancement by multiscale adaptive histogram equalization. In: International symposium on optical science and technology. International society for optics and photonics
13.
go back to reference Prasad VSN, Domke J (2005) Gabor filter visualization. J Atmos Sci 13 Prasad VSN, Domke J (2005) Gabor filter visualization. J Atmos Sci 13
14.
go back to reference Osher S, Sethian JA (1988) Fronts propagating with curvature-dependent speed: algorithms based on Hamilton-Jacobi formulations. J Comput Phys 79:12–49CrossRef Osher S, Sethian JA (1988) Fronts propagating with curvature-dependent speed: algorithms based on Hamilton-Jacobi formulations. J Comput Phys 79:12–49CrossRef
15.
go back to reference Hassouna MS, Farag AA (2007) Multistencils fast marching methods: a highly accurate solution to the Eikonal equation on Cartesian domains. IEEE Trans Pattern Anal Mach Intell 29(9):1563–1574CrossRefPubMed Hassouna MS, Farag AA (2007) Multistencils fast marching methods: a highly accurate solution to the Eikonal equation on Cartesian domains. IEEE Trans Pattern Anal Mach Intell 29(9):1563–1574CrossRefPubMed
16.
go back to reference Godunov SK (1959) A finite difference method for the numerical computation of discontinuous solutions of the equations of fluid dynamics. Matematicheskii Sbornik 47:357–393 Godunov SK (1959) A finite difference method for the numerical computation of discontinuous solutions of the equations of fluid dynamics. Matematicheskii Sbornik 47:357–393
17.
go back to reference Van Uitert R, Bitter I (2007) Subvoxel precise skeletons of volumetric data based on fast marching methods. Med Phys 34(2):627CrossRefPubMed Van Uitert R, Bitter I (2007) Subvoxel precise skeletons of volumetric data based on fast marching methods. Med Phys 34(2):627CrossRefPubMed
18.
go back to reference Tu S, Hao P, Koning G et al (2011) In vivo assessment of optimal viewing angles from X-ray coronary angiography. Eurointervention 7(1):112CrossRefPubMed Tu S, Hao P, Koning G et al (2011) In vivo assessment of optimal viewing angles from X-ray coronary angiography. Eurointervention 7(1):112CrossRefPubMed
19.
go back to reference Toth G, Hamilos M, Pyxaras S et al (2014) Evolving concepts of angiogram: fractional flow reserve discordances in 4000 coronary stenoses. Eur Heart J 35(40):2831–2838CrossRefPubMed Toth G, Hamilos M, Pyxaras S et al (2014) Evolving concepts of angiogram: fractional flow reserve discordances in 4000 coronary stenoses. Eur Heart J 35(40):2831–2838CrossRefPubMed
20.
go back to reference Tu S, Echavarria-Pinto M, Birgelen CV et al (2015) Fractional flow reserve and coronary bifurcation anatomy: a novel quantitative model to assess and report the stenosis severity of bifurcation lesions. JACC Cardiovasc Interv 8(4):564–574CrossRefPubMed Tu S, Echavarria-Pinto M, Birgelen CV et al (2015) Fractional flow reserve and coronary bifurcation anatomy: a novel quantitative model to assess and report the stenosis severity of bifurcation lesions. JACC Cardiovasc Interv 8(4):564–574CrossRefPubMed
21.
go back to reference Götberg M, Fröbert O (2017) Instantaneous wave-free ratio versus fractional flow reserve. N Engl J Med 377(16):1813–1823CrossRef Götberg M, Fröbert O (2017) Instantaneous wave-free ratio versus fractional flow reserve. N Engl J Med 377(16):1813–1823CrossRef
22.
go back to reference Gould KL (1978) Pressure-flow characteristics of coronary stenoses in unsedated dogs at rest and during coronary vasodilation. Circ Res 43(2):242–253CrossRefPubMed Gould KL (1978) Pressure-flow characteristics of coronary stenoses in unsedated dogs at rest and during coronary vasodilation. Circ Res 43(2):242–253CrossRefPubMed
23.
go back to reference Mejía-Rentería H, Lee JM, Lauri F et al (2018) Influence of microcirculatory dysfunction on angiography-based functional assessment of coronary stenoses. JACC Cardiovasc Interv 11(8):741–753CrossRefPubMed Mejía-Rentería H, Lee JM, Lauri F et al (2018) Influence of microcirculatory dysfunction on angiography-based functional assessment of coronary stenoses. JACC Cardiovasc Interv 11(8):741–753CrossRefPubMed
Metadata
Title
Automatic coronary blood flow computation: validation in quantitative flow ratio from coronary angiography
Authors
Yimin Zhang
Su Zhang
Jelmer Westra
Daixin Ding
Qiuyang Zhao
Junqing Yang
Zhongwei Sun
Jiayue Huang
Jun Pu
Bo Xu
Shengxian Tu
Publication date
01-04-2019
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue 4/2019
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-018-1506-y

Other articles of this Issue 4/2019

The International Journal of Cardiovascular Imaging 4/2019 Go to the issue