Skip to main content
Top
Published in: The International Journal of Cardiovascular Imaging 3/2019

01-03-2019 | Original Paper

A propensity score matched valuation on feasibility of low frame rate fluoroscopy during primary percutaneous coronary intervention for patients with STEMI

Authors: Lin Fan, Yukun Luo, Zhaoyang Chen, Wei Cai, Xianfeng Dong, Chaogui Lin, Lianglong Chen

Published in: The International Journal of Cardiovascular Imaging | Issue 3/2019

Login to get access

Abstract

The present study aimed to evaluate the feasibility of low frame rate fluoroscopy during primary percutaneous coronary intervention (PPCI) for patients with acute ST elevation myocardial infarction (STEMI). From January 2016 to December 2017, 165 consecutive patients with STEMI who underwent PPCI were retrospectively divided into two groups: the 7.5-frame group (fluoroscopy at 7.5 frames/s) and the 15-frame group (fluoroscopy at 15 frames/s), according to the frame rate of fluoroscopy used in their treatment. Reduction of radiation and safety of fluoroscopy at 7.5 frames/s were compared by a method of propensity score matching (PSM) with fluoroscopy at 15 frames/s. After PSM, there were 56 patients in each group. There were no differences in patients’ baseline characteristics between two groups. The 7.5-frame protocol resulted in 48.9% reduction of DAP (9917 ± 5543 cGycm2 vs. 14766 ± 7272 cGycm2, P < 0.001) and 61.1% reduction of AK (1209 ± 562 mGy vs. 1948 ± 1105 mGy, P < 0.001) with comparable procedural time (38.1 ± 15.3 min vs. 38.8 ± 17.2 min, P = 0.830), fluoroscopy time (13.0 ± 7.2 min vs. 13.5 ± 8.1 min, P = 0.703) and contrast volume (122.3 ± 39.4 ml vs. 119.3 ± 49.4 ml, P = 0.725) to the 15-frame group. Meanwhile, this new protocol didn’t increase the incidence of contrast-induced nephropathy (23.2% vs. 25.0%, OR = 0.907, 95% CI 0.381–2.157, P = 0.825) and peri-PPCI cumulative adverse events (30.4% vs. 28.6%, OR = 1.090, 95% CI 0.483–2.456, P = 0.836). In conclusion, low frame rate fluoroscopy at 7.5 frames/s is a safe and feasible strategy for reducing radiation during PPCI.
Literature
1.
go back to reference Eloot L, Thierens H, Taeymans Y et al (2015) Novel X-ray imaging technology enables significant patient dose reduction in interventional cardiology while maintaining diagnostic image quality. Catheter Cardiovasc Interv 86:E205–E212CrossRefPubMedPubMedCentral Eloot L, Thierens H, Taeymans Y et al (2015) Novel X-ray imaging technology enables significant patient dose reduction in interventional cardiology while maintaining diagnostic image quality. Catheter Cardiovasc Interv 86:E205–E212CrossRefPubMedPubMedCentral
2.
go back to reference Pyne CT, Gadey G, Jeon C et al (2014) Effect of reduction of the pulse rates of fluoroscopy and CINE-acquisition on X-ray dose and angiographic image quality during invasive cardiovascular procedures. Circ Cardiovasc Interv 7:441–446CrossRefPubMed Pyne CT, Gadey G, Jeon C et al (2014) Effect of reduction of the pulse rates of fluoroscopy and CINE-acquisition on X-ray dose and angiographic image quality during invasive cardiovascular procedures. Circ Cardiovasc Interv 7:441–446CrossRefPubMed
3.
go back to reference Wassef AW, Hiebert B, Ravandi A et al (2014) Radiation dose reduction in the cardiac catheterization laboratory utilizing a novel protocol. JACC Cardiovasc Interv 7:550–557CrossRefPubMed Wassef AW, Hiebert B, Ravandi A et al (2014) Radiation dose reduction in the cardiac catheterization laboratory utilizing a novel protocol. JACC Cardiovasc Interv 7:550–557CrossRefPubMed
4.
go back to reference Ebrahimi R, Uberoi A, Treadwell M et al (2016) Effect of low-frame invasive coronary angiography on radiation and image quality. Am J Cardiol 118:195–197CrossRefPubMed Ebrahimi R, Uberoi A, Treadwell M et al (2016) Effect of low-frame invasive coronary angiography on radiation and image quality. Am J Cardiol 118:195–197CrossRefPubMed
5.
go back to reference Abdelaal E, Plourde G, MacHaalany J et al (2014) Effectiveness of low rate fluoroscopy at reducing operator and patient radiation dose during transradial coronary angiography and interventions. JACC Cardiovasc Interv 7:567–574CrossRefPubMed Abdelaal E, Plourde G, MacHaalany J et al (2014) Effectiveness of low rate fluoroscopy at reducing operator and patient radiation dose during transradial coronary angiography and interventions. JACC Cardiovasc Interv 7:567–574CrossRefPubMed
6.
go back to reference Sadamatsu K, Nakano Y (2016) The effect of low frame rate fluoroscopy on the x-ray dose during coronary intervention. Intern Med 55:1943–1946CrossRefPubMed Sadamatsu K, Nakano Y (2016) The effect of low frame rate fluoroscopy on the x-ray dose during coronary intervention. Intern Med 55:1943–1946CrossRefPubMed
7.
go back to reference Ge L, Zhong X, Ma J et al (2017) Safety and feasibility of a low frame rate protocol for percutaneous coronary intervention to chronic total occlusionspreliminary experience. EuroIntervention 14:e538–e545 Ge L, Zhong X, Ma J et al (2017) Safety and feasibility of a low frame rate protocol for percutaneous coronary intervention to chronic total occlusionspreliminary experience. EuroIntervention 14:e538–e545
8.
go back to reference Bashore TM, Balter S, Barac A et al (2012) 2012 American College of Cardiology Foundation/Society for Cardiovascular Angiography and interventions expert consensus document on cardiac catheterization laboratory standards update: a report of the American College of Cardiology Foundation task force on expert consensus documents developed in collaboration with the Society of Thoracic Surgeons and Society for Vascular Medicine. J Am Coll Cardiol 59:2221–2305CrossRefPubMed Bashore TM, Balter S, Barac A et al (2012) 2012 American College of Cardiology Foundation/Society for Cardiovascular Angiography and interventions expert consensus document on cardiac catheterization laboratory standards update: a report of the American College of Cardiology Foundation task force on expert consensus documents developed in collaboration with the Society of Thoracic Surgeons and Society for Vascular Medicine. J Am Coll Cardiol 59:2221–2305CrossRefPubMed
9.
go back to reference Kim S, Toncheva G, Anderson-Evans C et al (2009) Kerma area product method for effective dose estimation during lumbar epidural steroid injection procedures: phantom study. AJR Am J Roentgenol 192:1726–1730CrossRefPubMed Kim S, Toncheva G, Anderson-Evans C et al (2009) Kerma area product method for effective dose estimation during lumbar epidural steroid injection procedures: phantom study. AJR Am J Roentgenol 192:1726–1730CrossRefPubMed
10.
go back to reference Levine GN, Bates ER, Blankenship JC et al (2011) 2011 ACCF/AHA/SCAI guideline for percutaneous coronary intervention: a report of the American College of Cardiology Foundation/American Heart Association task force on practice guidelines and the Society for Cardiovascular Angiography and Interventions. Circulation 124:e574–e651PubMed Levine GN, Bates ER, Blankenship JC et al (2011) 2011 ACCF/AHA/SCAI guideline for percutaneous coronary intervention: a report of the American College of Cardiology Foundation/American Heart Association task force on practice guidelines and the Society for Cardiovascular Angiography and Interventions. Circulation 124:e574–e651PubMed
11.
go back to reference Cutlip DE, Windecker S, Mehran R et al (2007) Clinical end points in coronary stent trials: a case for standardized definitions. Circulation 115:2344–2351CrossRefPubMed Cutlip DE, Windecker S, Mehran R et al (2007) Clinical end points in coronary stent trials: a case for standardized definitions. Circulation 115:2344–2351CrossRefPubMed
12.
go back to reference Zoungas S, Ninomiya T, Huxley R et al (2009) Systematic review: sodium bicarbonate treatment regimens for the prevention of contrast-induced nephropathy. Ann Intern Med 17:631–638CrossRef Zoungas S, Ninomiya T, Huxley R et al (2009) Systematic review: sodium bicarbonate treatment regimens for the prevention of contrast-induced nephropathy. Ann Intern Med 17:631–638CrossRef
13.
go back to reference Koenig TR, Mettler FA, Wagner LK (2001) Skin injuries from fluoroscopically guided procedures: part 2, review of 73 cases and recommendations for minimizing dose delivered to patient. AJR Am J Roentgenol 177:13–20CrossRefPubMed Koenig TR, Mettler FA, Wagner LK (2001) Skin injuries from fluoroscopically guided procedures: part 2, review of 73 cases and recommendations for minimizing dose delivered to patient. AJR Am J Roentgenol 177:13–20CrossRefPubMed
14.
go back to reference Wagner LK, Eifel PJ, Geise RA (1994) Potential biological effects following high x-ray dose interventional procedures. J Vasc Interv Radiol 5:71–84CrossRefPubMed Wagner LK, Eifel PJ, Geise RA (1994) Potential biological effects following high x-ray dose interventional procedures. J Vasc Interv Radiol 5:71–84CrossRefPubMed
15.
go back to reference Pierce DA, Preston DL (2000) Radiation-related cancer risks at low doses among atomic bomb survivors. Radiat Res 154:178–186CrossRefPubMed Pierce DA, Preston DL (2000) Radiation-related cancer risks at low doses among atomic bomb survivors. Radiat Res 154:178–186CrossRefPubMed
16.
go back to reference Kuon E, Weitmann K, Hoffmann W et al (2014) Efficacy of a minicourse in radiation-reducing techniques in invasive cardiology: a multicenter field study. JACC Cardiovasc Interv 7:382–390CrossRefPubMed Kuon E, Weitmann K, Hoffmann W et al (2014) Efficacy of a minicourse in radiation-reducing techniques in invasive cardiology: a multicenter field study. JACC Cardiovasc Interv 7:382–390CrossRefPubMed
17.
go back to reference Kuon E, Empen K, Weitmann K et al (2013) Long-term efficacy of a minicourse in radiation-reducing techniques in invasive cardiology. Rofo 185:720–725CrossRefPubMed Kuon E, Empen K, Weitmann K et al (2013) Long-term efficacy of a minicourse in radiation-reducing techniques in invasive cardiology. Rofo 185:720–725CrossRefPubMed
18.
go back to reference Kuon E, Schmitt M, Dahm JB (2002) Significant reduction of radiation exposure to operator and staff during cardiac interventions by analysis of radiation leakage and improved lead shielding. Am J Cardiol 89:44–49CrossRefPubMed Kuon E, Schmitt M, Dahm JB (2002) Significant reduction of radiation exposure to operator and staff during cardiac interventions by analysis of radiation leakage and improved lead shielding. Am J Cardiol 89:44–49CrossRefPubMed
Metadata
Title
A propensity score matched valuation on feasibility of low frame rate fluoroscopy during primary percutaneous coronary intervention for patients with STEMI
Authors
Lin Fan
Yukun Luo
Zhaoyang Chen
Wei Cai
Xianfeng Dong
Chaogui Lin
Lianglong Chen
Publication date
01-03-2019
Publisher
Springer Netherlands
Published in
The International Journal of Cardiovascular Imaging / Issue 3/2019
Print ISSN: 1569-5794
Electronic ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-018-1475-1

Other articles of this Issue 3/2019

The International Journal of Cardiovascular Imaging 3/2019 Go to the issue